My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6860-6862 Medical View Ln
Zephyrhills
>
Building Department
>
Building Plans
>
6860-6862 Medical View Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:07:20 PM
Creation date
2/19/2025 8:36:26 AM
Metadata
Fields
Template:
Building Plans
Street #
6860-6862
Location
Medical View Ln
Contractor
Bandes Contractors
Building Plans - Permit #
4055
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 11 <br />N <br />CO <br />TM <br />W <br />N <br />N <br />0 <br />N <br />- d- <br />N <br />T <br />- FLOOR PLAN GENERAL NOTES <br />1. ALL DOORS TO BE 4" FROM INSIDE CORNER OF GYP. BD., U.N.O. <br />2. REFER TO LIFE SAFETY PLANS FOR FIRE EXTINGUISHER TYPES AND LOCATIONS. <br />3. GENERAL CONTRACTOR SHALL PROVIDE CONDUIT, POWER, PLUMBING AND COORDINATION FOR ALL EQUIPMENT/ ITEMS PROVIDED BY <br />OWNER OR OTHERS. <br />4. "BY OTHERS" INDICATES THAT THIS ITEM IS NOT INCLUDED IN THE GENERAL CONTRACTOR'S SCOPE OF WORK. <br />5. PROVIDE SOUND ATTENUATION INSULATION WITH A MIN. STC RATING OF 50 IN ALL STUD WALLS INDICATED TO HAVE SOUND BATT <br />INSULATION - THESE WALLS (ENCLOSING SPACES ON ALL SIDES) TO EXTEND TO UNDERSIDE OF DECK PER WALL TYPES. <br />6. ALL NON -BEARING WALLS SHALL EXTEND TO 6" ABOVE FINISHED CEILING, U.N.O. <br />7. SEAL ALL VOIDS AT TOP OF CMU WALLS TO DECK. <br />8. SEE WALL TYPES SHEET FOR ADDITIONAL INFORMATION. <br />9. REFER TO SHEET A102 AND S100 FOR BUILDING DIMENSIONS. <br />10. INTERIOR DIMENSIONS ARE TAKEN FROM FACE OF FINISH TO FACE OF FINISH. <br />11. REFER TO STRUCTURAL PLANS FOR EXTERIOR WALL OPENINGS. <br />12. REFER TO FINISH PLAN FOR WALL TILE. <br />13. REFER TO ELECTRICAL PLANS FOR IT EQUIPMENT, WAP, TV CONNECTIONS, ETC. WIRING TO CORRECT LOCATIONS BY G.C., AND <br />EQUIPMENT INSTALLATION BY OWNER. <br />3 <br />A B D A201 F H K L <br />1 ( 6 1 6 <br />A551 A552 <br />FLOOR PLAN <br />NORTH 1 <br />R SER / UTILITY <br />P-109 <br />I <br />I <br />I <br />I <br />I <br />12 I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />-1 rlr1M I71 A AI IZCVAir'\TC0 <br />1 LVVI I I L/-lIY 1\L I IVV I LV <br />10 FLOOR DRAIN - REFER TO PLUMBING DRAWING <br />OMOP BASIN - REFER TO PLUMBING DRAWING <br />OSLAB ON GRADE, REFER ALSO TO STRUCTURAL DWGS. <br />04 MILLWORK. REFER TO MILLWORK ELEVATIONS & DETAILS. <br />4a EXAM ROOM MILLWORK. REFER TO DETAILS 15 AND 5 ON SHEET <br />A750. <br />4b EXAM ROOM MILLWORK. REFER TO DETAILS 15 AND 5 ON SHEET <br />A750 (OPPOSITE). <br />OEQUIPMENT BY OWNER. <br />OALUMINUM DOWN SPOUT REFER TO ROOF PLAN <br />ORECEPTIONIST DESK, REFER TO SHEET A750. <br />OREFRIGERATOR / FREEZER / MICROWAVE BY OWNER - G.C. TO <br />COORD. POWER AND PLUMBING REQUIREMENTS. <br />OCOVERED OUTDOOR BREAK AREA - ROOF SYSTEM BY OTHERS. <br />10 STEEL COLUMN, PAINTED. REFER TO STRUCTURAL DWGS. <br />11 HI-LO DRINKING FOUNTAIN. SEE PLUMBING DWGS. <br />12 LINE OF ROOF OR SOFFIT ABOVE. REFER TO CEILING AND ROOF <br />PLANS. <br />13 LANDSCAPE AREA - SEE CIVIL <br />MAINTAIN FLOOR ELEVATION (MAX. 1/2" VARIATION) FOR A <br />14 DISTANCE OF AT LEAST 5-0" FROM INTERIOR TO EXTERIOR AT <br />ALL EXTERIOR EGRESS DOORS. SEE VERTICAL CHANGES IN <br />LEVEL DETAILS FOR MORE INFORMATION <br />15 IT. RACK <br />16 CLOSET SHELVING <br />17 RECEPTION WINDOW. SEE MILLWORK ELEVATIONS AND DETAILS <br />FOR MORE INFORMATION <br />18 COVERED ENTRY <br />19 ROOF LADDER - REFER TO ROOF PLAN AND DETAILS <br />20 SEMI -RECESSED FIRE EXTINGUISHER - REFER TO LIFE SAFETY <br />PLAN <br />21 PASS THROUGH CABINET - REFER TO ENLARGED PLANS AND <br />ELEVATIONS <br />-1 rNf-%r) ni A AI nX/R Af7)r1I C% <br />1 LVVI l l I_!ll V V I IVIUVLV <br />W# STOREFRONT WINDOW - REFER TO GLAZING ELEVATIONS <br />## DOOR NUMBER - REFER TO DOOR SCHEDULE <br />A <br />WALL TYPE - REFER WALL TYPE DETAILS <br />LINE OF ROOF OR SOFFIT ABOVE <br />FBC ACCESSIBILITY CODE 303.2 VERTICAL <br />MAXIMUM CHANGE IN LEVEL 1/4" MAX TO BE VERTICAL <br />7t <br />12 0 - <br />0 <br />0 <br />FBC ACCESSIBILITY CODE 303.3 BEVELED <br />2 CHANGES IN LEVEL BETWEEN 1/4 INCH HIGH MINIMUM AND <br />1/2 INCH HIGH MAXIMUM SHALL BE BEVELED WITH A SLOPE <br />A201 NOT STEEPER THAN 1:2. <br />2 VERTICAL CHANGES IN LEVEL DETAILS <br />REVIEWED FOR <br />CODE COMPLIANCE <br />UNIVERSAL ENGINEERING SCIENCES <br />i DRAWING AND THE DESIGN SHOWN ARE THE PROPERTY 01 <br />LING ENGINEERING, INC. AND ARE NOT TO BE REPRODUCED, <br />'IED, PUBLISHED, OR USED IN WHOLE OR PART WITHOUT <br />TTEN CONSENT. THEY ARE TO BE USED ONLY FOR THE SITE <br />)JECT IDENTIFIED AND SHALL BE RETURNED UPON REQUEST <br />FOR <br />CONSTRUCTION <br />ISSUE DATE: 01.24.2022 <br />z <br />0 <br />a <br />U <br />ui <br />w <br />0 <br />w <br />a <br />0 <br />l(uri <br />C/)M� <br />Q <br />� 1 � <br />. c� <br />� wM <br />a� <br />W <br />U w N <br />uj z _J CM <br />M <br />W V ULL <br />= Qo C/ <br />w J <br />Lu N = <br />Z o °C <br />W °_ <br />o0- <br />(D w <br />a 00 <br />oN <br />0 <br />. u O <br />Ux <br />P4 D <br />O <br />J <br />Q <br />W <br />D <br />CONTRACT DATE:: <br />Q•j3 0 <br />Z CD <br />W zo Y <br />>_ zp Q <br />as <br />zz o <br />2z z <br />w w <br />U) <br />N <br />WzW w <br />_0 <br />J <br />06 <br />00 <br />O <br />O <br />O <br />O <br />i O <br />• Q <br />y_ a U- <br />^♦ J <br />W co <br />CD <br />■� cL.L <br />N <br />o <br />W".'0 <br />W_ <br />t <br />V � <br />a� <br />FLOOR PLAN <br />DESIGNED BY: <br />DJR <br />DRAWN BY: <br />DJR <br />CHECKED BY: <br />DJR <br />JOB NO. <br />2021-18 <br />SHEET NO. <br />Al 01 <br />� J <br />
The URL can be used to link to this page
Your browser does not support the video tag.