INTERIOR FINISH MATERIAL LEGEND <br />FINISH <br />MATERIAL <br />CODE <br />MANUFACTURER <br />PRODUCT <br />COLOR / OPTIONS <br />SIZE <br />LOCATION <br />REMARK <br />CONTACT <br />SURFACE <br />LUXURY VINYL TILE <br />LVT-1 <br />SHAW CONTRACT <br />LUXURY VINYL TILE <br />BAY CHESTNUT 00710 <br />OFFICES, CORRIDORS, BREAK ROOM, <br />SHAW CONTACT: JON MCENTYRE <br />NATIVE ORIGINS 0116V <br />ETC. <br />770-878-0489 <br />PORCELAIN TILE <br />T-1 <br />DALTILE <br />CHORD COLORBODY <br />FORTE GREY CH25 <br />12" x 24" (NOMINAL) <br />MENS & WOMENS RESTROOM FLOORS/ <br />- <br />ASHLEY WILKES <br />PORCELAIN TILE <br />WALLS <br />SOUTHEAST SR. ARCHITECTURAL REP. <br />CEMENT VISUAL <br />404-702-8022 <br />FLOORS <br />GROUT <br />GRT-1 <br />MAPEI <br />KERAPDXY CO <br />104 TIMBERWOLF <br />USE WITH TILE T-1 <br />JERE STREET 770-350-3417 <br />JSTREET@MAPEI.COM <br />SEALED CONCRETE <br />CNC-1 <br />- <br />TBD <br />WOOD BASE <br />WB-1 <br />1x6 MILLED HARDWOOD <br />PROFILE TO BE DETERMINED <br />5 1/2" x 12 ft. <br />COMMON AREAS (REFER TO FINISH <br />PLANS) <br />WOOD BASE <br />WB-2 <br />ix4 MILLED HARDWOOD <br />PROFILE TO BE DETERMINED <br />3 1/2" x 12 ft. <br />WAITING AREAS (REFER TO FINISH <br />PLANS <br />WOOD CHAIR RAIL <br />WC-1 <br />1x6 MILLED HARDWOOD <br />PROFILE TO BE DETERMINED <br />5 1/2" x 12 ft. <br />COMMON AREAS (REFER TO FINISH <br />PLANS) <br />WOOD CHAIR RAIL <br />WC-2 <br />1x4 MILLED HARDWOOD <br />PROFILE TO BE DETERMINED <br />3 1/2" x 12 ft. <br />WAITING AREAS (REFER TO FINISH <br />MOULDINGS/ <br />PLANS <br />BASE <br />PVC BASE <br />PVC-1 <br />AIC MILLWORKS <br />PROFILE/ COLOR TO BE <br />4" HIGH <br />EXAM ROOMS (REFER TO FINISH PLANS) <br />DETERMINED <br />PVC CHAIR RAIL <br />PVC-2 <br />AIC MILLWORKS <br />PROFILE/ COLOR TO BE <br />4" HIGH <br />EXAM ROOMS (REFER TO FINISH PLANS) <br />DETERMINED <br />RESILIENT WALL <br />RWB-1 <br />JOHNSONITE <br />TRADITIONAL WALL BASE <br />COLOR TO BE DETERMINED <br />4" x FULL LENGTH ROLLS <br />REFER TO FINISH PLANS <br />BASE <br />PAINT <br />P-1 <br />- <br />- <br />NEUTRAL BEIGE (FINAL COLOR TO <br />ALL WALLS/INTERIOR DOOR FRAMES <br />BE DETERMINED) <br />UNLESS NOTED OTHERWISE <br />PAINT <br />P-2 <br />- <br />MINT GREEN (FINAL COLOR TO BE <br />ACCENT WALL (TRIAGE, DENTAL <br />P-2- (PROVIDE P-1 <br />DETERMINED) <br />RECEPTION, WAITING AREA, PATIENT <br />BELOW CHAIR RAIL) <br />EXAM ROOM) <br />PAINT <br />P-3 <br />- <br />LIGHT BLUE (FINAL COLOR TO BE <br />ACCENT WALL (FAMILY RECEPTION), <br />P-3- (PROVIDE P-1 <br />DETERMINED) <br />WAITING AREAS, PATIENT EXAM ROOM) <br />BELOW CHAIR RAIL) <br />WALLS <br />PAINT <br />P-4 <br />- <br />TAN (FINAL COLOR TO BE <br />ACCENT WALL (PEDIATRICS RECEPTION, <br />DETERMINED) <br />WAITING AREA, EXAM ROOM) <br />PAINT <br />P-5 <br />- <br />PINK (FINAL COLOR TO BE <br />CHILDREN'S WAITING AREA ACCENT <br />P-5" (PROVIDE P-1 <br />DETERMINED) <br />WALL <br />BELOW CHAIR RAIL) <br />TILE <br />T-2 <br />GRANITI FIANDRE <br />#WOD09S123 <br />A -WOOD W/ SPECTRALOCK PRO <br />8"x48" (1/3 RUNNING <br />REAR WALL ( RECEPTION RM. 100) <br />PREMIUM GROUT, BY LATICRETE <br />BOND) <br />SUSPENDED <br />ACT-1 <br />ARMSTRONG <br />DUNE <br />24" x 24" <br />TEGULAR <br />ACOUSTICAL <br />CEILING TILE <br />SUSPENDED <br />GRID-1 <br />PRELUDE <br />EXPOSED TEE <br />15/16" <br />24" x 24" <br />CEILINGS <br />CEILING GRID <br />LINEAR METAL <br />LMC-1 <br />MBCI <br />ARTISAN <br />COLOR TO BE DETERMINED <br />8" PLANK x 10' <br />INTERIOR LOBBY <br />SOFFIT PANEL <br />PLASTIC LAMINATE <br />LAM-1 <br />NEVAMAR <br />PLASTIC LAMINATE WITH <br />UNTOLD JOURNEY WW4400-VE <br />REFER TO MILLWORK ELEVATIONS/ <br />- <br />877-726-6526 <br />ARMORED PROTECTION <br />(VELVET) <br />SECTIONS <br />PLASTIC LAMINATE <br />LAM-2 <br />NEVAMAR <br />PLASTIC LAMINATE WITH <br />TBD <br />REFER TO DOOR SCHEDULE <br />- <br />877-726-6526 <br />MILLWORK <br />ARMORED PROTECTION <br />SOLID SURFACE <br />SS-1 <br />CORIAN <br />SOLID SURFACE <br />SAVANNAH <br />COUNTERTOPS <br />- <br />800-4CORIAN (800-426-7426) <br />SEALANT <br />MAPEI <br />MAPESIL T (SILICONE) <br />23 CLEAR <br />CAFE COUNTERTOP TO BACKSPLASH <br />JERE STREET 770-350-3417 <br />JOINT <br />JSTREET@MAPEI.COM <br />MISCELLANEOUS <br />SEALANT <br />MAPEI <br />KERACAULK S (SANDED) <br />14 BISCUIT <br />RESTROOM COUNTERTOP TO TILED <br />JERE STREET 770-350-3417 <br />WALL JOINT - TO MATCH GROUT GRT-2 <br />JSTREETCa MAPEI.COM <br />EXTERIOR FINISH MATERIAL LEGEND <br />FINISH <br />MATERIAL <br />CODE <br />MANUFACTURER <br />PRODUCT <br />COLOR / OPTIONS <br />SIZE <br />LOCATION <br />REMARK <br />CONTACT <br />SURFACE <br />PAINT <br />EPT-1 <br />- <br />SEE SPECIFICATIONS <br />COLOR TO BE DETERMINED <br />EXTERIOR PAINT (STUCCO SURFACES/ <br />H.M. DOORS AND FRAMES) REFER TO <br />BUILDING ELEVATIONS. <br />EXTERIOR <br />PAINT <br />PAINT <br />EPT-2 <br />- <br />SEE SPECIFICATIONS <br />COLOR TO BE DETERMINED <br />EXTERIOR PAINT (STRUCTURAL <br />COLUMNS/ BEAMS AT COVERED ENTRY) <br />REFER TO BUILDING ELEVATIONS. <br />STONE <br />ST-1 <br />ELDORADO <br />LONGITUDE 24 <br />WILD OAT <br />12" X 24" <br />SEE EXTERIOR ELEVATIONS AND <br />STONE VENEER <br />DETAILS <br />PRECAST <br />PC-1 <br />- <br />- <br />COLOR TO BE DETERMINED <br />- <br />SEE EXTERIOR ELEVATIONS AND <br />PRECAST <br />CONCRETE <br />DETAILS <br />COPING CAP <br />LINEAR METAL <br />LMC-1 <br />MBCI, L.P. <br />FW-120-1 (12" PANEL W/ 6" <br />COLOR TO BE DETERMINED <br />0'-8" X 10'-0" PLANK <br />EXTERIOR CANOPY UNDERSIDE, SEE <br />EXTERIOR <br />SOFFIT PANEL <br />BEAD) <br />REFLECTED CEILING PLAN <br />SOFFIT <br />FIBER <br />FIBER CEMENT WALL <br />FCC-1 <br />NICHIHA <br />ARCHITECTURAL WALL <br />COLOR TO BE DETERMINED <br />N/A <br />SEE EXTERIOR ELEVATIONS AND <br />CEMENT <br />PANELS <br />PANEL <br />DETAILS <br />CLADDING <br />DEFS SYSTEM <br />DFS-1 <br />STO CORP. <br />- <br />COLOR TO MATCH EPT-1 <br />N/A <br />SEE REFLECTED CEILING PLAN <br />EXTERIOR <br />CEILING <br />BRICK PAVER <br />PVR-1 <br />- <br />BRICKPAVERS <br />COLOR TO BE DETERMINED <br />4" x 8" x 2 1/4" <br />SEE CIVIL FOR MORE INFORMATION <br />BRICK <br />PAVERS <br />ALUMINUM <br />ACM <br />ACM-1 <br />- <br />SEE SPECIFICATIONS <br />COLOR TO BE DETERMINED <br />SEE EXTERIOR ELEVATIONS AND <br />COMPOSITE <br />DETAILS <br />MATERIAL <br />r� <br />c <br />CV <br />co <br />00 <br />N <br />N <br />O <br />N <br />N <br />- FINISH MATERIAL GENERAL NOTES <br />GENERAL: <br />PAINT AND WALLCOVERING (CONT'): <br />1. <br />ALL INTERIOR FINISH SPECIFICATIONS AS REQUIRED BY THE ARCHITECT ARE INCLUDED <br />11. <br />PREPARE ALL SURFACES TO RECEIVE PAINT ACCORDING TO PAINT MANUFACTURER'S <br />HEREIN. CONTACT THE ARCHITECT FOR CLARIFICATION OF ANY AMBIGUITIES, <br />SPECIFICATIONS. PRIME GYPSUM BOARD SURFACES WITH ONE COAT PRIMER. PREPARE <br />DISCREPANCIES OR OMISSIONS BEFORE PROCEEDING. <br />AND PRIME MASONRY SURFACES WITH 2 COATS BLOCK FILLER. <br />2. <br />WALL AND BASE MATERIAL INDICATED IN FINISH SCHEDULE IS TYPICAL FOR ALL VERTICAL <br />12. <br />APPLY 1 COAT OF PRIMER AND 2 COATS OF FINISH PAINT, UNLESS NOTED OTHERWISE. <br />SURFACES IN THE DESIGNATED SPACE, UNLESS NOTED OTHERWISE. <br />13. <br />PREPARE AND PRIME SURFACES TO RECEIVE WALLCOVERING WITH MANUFACTURER- <br />3. <br />ALL FINISHES ARE INDICATED IN THE FINISH SCHEDULE OR NOTED IN THE DRAWINGS. NO <br />APPROVED PRIMER. <br />FINISH SUBSTITUTIONS WILL BE ACCEPTED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. <br />GENERAL CONTRACTOR IS TO SUBMIT SAMPLES OF ALL SPECIFIED FINISH MATERIALS TO <br />CERAMIC TILE: <br />ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. <br />14. <br />INSTALL SCHLUTER TRANSITION STRIP AS SHOWN IN FINISH LEGEND AND FINISH PLANS <br />AND INTERIOR ELEVATIONS. <br />4. <br />ALL EXPOSED GYPSUM BOARD EDGES SHALL HAVE A METAL "LC" BEAD FLOOR TO CEILING. <br />PARTITIONS SHALL BE CONTINUOUS OVER DOORS, SAME AS ADJACENT WALLS, WHERE <br />15. <br />WHERE FINISH FLOOR MATERIAL SEAMS OCCUR AT DOORS, THEY ARE TO BE PARALLEL <br />GYPSUM WALL BOARD CONTINUES TO STRUCTURE ABOVE. <br />WITH THE DOOR IN THE CLOSED POSITION AND CENTERED ON THE THICKNESS OF THE <br />DOOR, UNLESS INDICATED OTHERWISE BY NOTE ON FINISH SCHEDULE OR ON FLOOR <br />5. <br />ALL STRUCTURAL COLUMNS AND MISCELLANEOUS GRILLES, PLATES ETC. OCCURRING ON <br />PLAN. <br />WALLS OR CEILINGS SHALL BE FINISHED TO MATCH THE WALL OR CEILING ON WHICH THEY <br />OCCUR, UNLESS NOTED OTHERWISE. <br />16. <br />FOR TILE INSTALLED ON CONCRETE ON -GROUND, INSTALL CERAMIC TILE PER TCNA <br />DETAIL F115-15. <br />6. <br />ALL VERTICALLY MOUNTED BUILDING ACCESSORIES (I.E.. DOOR STOPS, COAT HOOKS) <br />SHALL BE MOUNTED ON PARTITIONS WITH IN -WALL BLOCKING AS REQUIRED. DO NOT <br />17. <br />PROVIDE PERIMETER JOINT, PER TCNA DETAIL EJ171G-15 AT ALL LOCATIONS WHERE <br />MOUNT ANY BUILDING ACCESSORIES ON DOORS. <br />TILEWORK ABUTS RESTRAINING SURFACES SUCH AS PERIMETER WALLS, DISSIMILAR <br />FLOORS, CURBS, COLUMNS, PIPES, CEILINGS, AND WHERE CHANGES OCCUR IN BACKING <br />7. <br />WHERE PARTITIONS ABUT BUILDING WINDOW MULLIONS, SEAL GAP WITH ACOUSTICAL <br />MATERIALS, BUT NOT AT DRAIN STRAINERS. <br />SEALANT BETWEEN PARTITION AND WINDOW MULLION. <br />18. <br />PROVIDE MOVEMENT JOINTS, PER TCNA DETAIL EJ171 F-15 AT A MAX. OF 25' O.C. EACH <br />8. <br />CONTRACTOR SHALL PROVIDE 5% OVERSTOCK OF FLOOR TILE, CARPET TILE AND CEILING <br />WAY FOR SLABS ON -GRADE, 12' O.C. EACH WAY FOR SLABS ABOVE -GRADE, OR AT <br />TILE FOR OWNER'S STORAGE. <br />LOCATIONS SHOWN ON FINISH PLANS. <br />9. <br />ALL FLOORING TO CONTINUE UNDER ALL MILLWORK, EQUIPMENT, BEVERAGE STATIONS, <br />19. <br />PROVIDE CONTRACTION JOINTS, PER TCNA DETAIL EJ171 B-15 AT ALL STRUCTURAL <br />AND SELF-SERVICE AREAS. <br />CONTRACTION JOINTS. <br />PAINT AND WALLCOVERING: <br />20. <br />CERAMIC TILE MOVEMENT AND CONTRACTION JOINTS TO BE 1/4" MIN., BUT SHALL NEVER <br />10. <br />ALL SURFACES TO RECEIVE FINISHES SHALL BE SMOOTH AND FREE OF DEFECTS. GYPSUM <br />BE LESS THAN THE WIDTH OF THE SAW -CUT CONTROL JOINT. JOINTS DIRECTLY OVER <br />BOARD SURFACES TO RECEIVE EGGSHELL OR FLAT PAINT OR WALLCOVERING SHALL BE <br />STRUCTURAL JOINTS SHALL NEVER BE LESS THAN THE STRUCTURAL JOINT. <br />FINISHED TO GYPSUM ASSOC. LEVEL 4 FINISH. PAINT AND WALLCOVERING <br />SUBCONTRACTORS ARE TO NOTIFY CONTRACTOR FOR CORRECTION OF ANY <br />21. <br />ANY COMBUSTIBLE INTERIOR TRIM SHALL BE CLASS A, B, OR C MATERIAL WITH A FLAME <br />UNACCEPTABLE CONDITIONS PRIOR TO PROCEEDING WITH FINISH APPLICATION. GYPSUM <br />SPREAD RATING OF 200 OR LESS. <br />BOARD SURFACES TO RECEIVE SEMI -GLOSS OR GLOSS PAINT SHALL BE FINISHED TO <br />GYPSUM ASSOC. LEVEL 5 FINISH. <br />NOTE: G.C. TO SUBMIT PRODUCT DATA/ PHYSICAL SAMPLES FOR ALL FINISH SELECTIONS FOR ARCHITECT/ OWNER APPROVAL PRIOR TO FINAL SELECTION. <br />REVIEWED FOR <br />CODE COMPLIANCE <br />UNIVERSAL ENGINEERING SCIENCES <br />FOR <br />CONSTRUCTION <br />ISSUE DATE: 01.24.2022 <br />z <br />0 <br />a <br />m <br />U <br />cn <br />w <br />0 <br />w <br />Q <br />0 <br />w <br />Q <br />(n r') <br />Q 1 <br />H <br />p <br />pw� <br />w <br />�w <br />W <br />Q <br />V <br />w CV <br />Lu <br />Z <br />_jM <br />_J — <br />M <br />W V <br />U_ LL <br />= <br />(6 <br />Q0 <br />W J <br />CJ <br />Lu <br />Z o <br />o <br />� W <br />°_ <br />�w <br />a� (oN <br />O <br />U <br />.� <br />O <br />U) <br />U� <br />O <br />J <br />Q <br />W <br />CONTRACT DATE: <br />w w I -- <br />cc <br />•�� <br />o <br />W zo <br />U <br />} z <br />p Q <br />aQ <br />zz <br />¢ <br />O <br />Fr <br />wo <br />>N <br />z <br />w <br />Ljw <br />Z <br />pp <br />w <br />U <br />co <br />co <br />Lo <br />0 <br />0 <br />0 <br />o <br />C o <br />z <br />Q <br />a <br />LL <br />W <br />rn <br />• <br />= N <br />C � <br />ujUJ0. <br />�cr; <br />Q <br />i r <br />o <br />FINISH <br />SCHEDULE <br />DESIGNED BY: DJR <br />DRAWN BY: DJR <br />CHECKED BY: DJR <br />HIS DRAWING AND THE DESIGN SHOWN ARE THE PROPERTY OF <br />;PRING ENGINEERING, INC. AND ARE NOT TO BE REPRODUCED, <br />;OPTED, PUBLISHED, OR USED IN WHOLE OR PART WITHOUT <br />VRITTEN CONSENT. THEY ARE TO BE USED ONLY FOR THE SITE AP <br />'ROJECT IDENTIFIED AND SHALL BE RETURNED UPON REQUEST. <br />JOB NO. <br />2021-18 <br />SHEET NO. <br />A300 <br />\ I <br />