"J" HOOKS SUPPORTED FROM <br />STRUCTURE OR WALL. PROVIDE <br />EVERY 6'-0" O.C. <br />I I I <br />TELECOM I.T. SWITCH STUB UP 6" ABOVE CEILING, AND 6" <br />AWAY FROM WALLS. PROVIDE <br />INSULATED BUSHING AND PULLWIRE. <br />r------------- — -- <br />CEILING LINE CEILING LINE <br />EXISTING TELEPHONE <br />BACKBOARD -':' —COMMUNICATION CABLING <br />BUNDLED NEATLY ABOVE <br />f CEILING & RUN PARALLEL TO 3/4" EMPTY CONDUIT <br />WALL AND CEILING. <br />SUPPORTED BY "J" HOOKS. i <br />PROVIDE # 6 GREEN GROUND <br />BONDING JUMPER FROM TELEPHONE <br />EQUIPMENT TO COOPER GROUND <br />BUS BAR IN ELECTRICAL ROOM. <br />WALL MOUNTED DATA <br />GROUNDING SYSTEM BUS OUTLET. <br />BAR IN ELECTRICAL ROOM. .. • .. 18"AFF <br />TYPICAL <br />TELEPHONE/DATA SYSTEM TYPICAL RISER DIAGRAM <br />N . T. S. <br />3/4" CONDUIT TO <br />WIREWAY BEHIND <br />MAMMOGRAM <br />FINISH CEILING LINE <br />-WL- <br />1 ` 2—#12 & 1-12 GND <br />(WL) WARNING LIGHT USE TO WARNING LIGHT <br />APPROVED FI <br />INCANDESCEN <br />CONTRACTOR TO PROVIDE 120 V <br />POWER TO LIGHT & RUN A SWITCH <br />LEG TO EQUIPMENT VIA WIREWAYS <br />LOCATED INSIDE ROOM. <br />--FINISH FLOOR LINE <br />TYPICAL DOOR SWITCHM/ARNING LIGHT DETAIL <br />N.T.S. <br />CONTRACTOR TO TEST EXISTING GROUNDING SYSTEM <br />LOCATED INSIDE THE MAIN ELECTRICAL ROOM AND <br />MAKE SURE THAT IT IS IN GOOD MECHANICAL <br />CONDITIONS. <br />X-RAY WARNING LIGHTS ARE EXISTING TO REMAIN. <br />CONTRACTOR TO TEST FOR PROPER OPERATION AND <br />REPLACE IF NEEDED. <br />RESTROOMS EXHAUST FANS ARE EXISTING TO REMAIN. <br />CONTRACTOR TO CHECK FOR PROPER OPERATION AND <br />REPLACE IF NEEDED. <br />NO ELECTRICAL WORK TO BE DONE IN HATCHED <br />AREAS UNLESS OTHERWISE SPECIFIED. <br />LETTER SYMBOLS <br />E — EXISTING TO REMAIN <br />ER — EXISTING TO BE REMOVED DURING CONSTRUCTION <br />AND REINSTALLED AFTER NEW WALL WILL BE IN <br />PLACED. <br />ALL DEVICES ARE NEW UNLESS OTHERWISE <br />INDICATED BY SYMBOLS ABOVE. <br />* — ALL EXISTING RECEPTACLES IN BATHROOMS, OUTDOOR <br />OR WITHIN 6" OF SINKS SHALL BE REPLACED WITH NEW <br />G.F.C.I. DECORA OR EQUAL. <br />GR( <br />" ' To the best of the Architect's knowledge these plans comply with the minimum standards of the applicable codes and life safety standards as determined in accordance with Chapter 553 and 663 of the Florida statutes <br />❑ <br />For Construction <br />❑ <br />Not for Construction <br />❑ <br />Bid Set <br />❑ <br />Review Set <br />No <br />® <br />Permit Set <br />❑ <br />Record Set <br />All designs, details and drawings indicated and <br />represented are for use on and in conjunction with <br />the specified project, the designs and drawings <br />are the property of the Architect and shall not be <br />reproduced in whole or in part without the written <br />permission of Mao Architecture, Inc <br />Date <br />Description <br />Project Name <br />AKU M I N - ZEPHYRH I LLS <br />INTERIOR ALTERATION <br />6900 GALL BLVD <br />ZEPHYRHILLS, FL 33542 <br />ELECTRICAL POWER PLAN <br />SCALE: 1 /4"=1 '-0" <br />Project Team <br />M.E. Engineering Consultants, Inc. <br />11401 S.W. 40th Street, Suite 301 <br />Ph:(305)905-4652 <br />CA 29121 <br />11401 SW 40th Street, <br />Suite 301 <br />Miami, FI 33165 <br />t: (786) 275-4635 <br />3 c: (305) 905-4657 <br />MICH11EMM e. mtrejo@m3oarchitecture.com <br />w w w m 3 o a r c h i t e c t u r e con <br />AA26003093 <br />iiiiidI0 <br />�'�•.•.\c E10 <br />NS•' F�®° <br />• o.6 8 0.1 <br />STAT O �• <br />• Ie <br />• �bz ka.•.\�44 <br />�ONA� <br />Zoila Morales, Electrical P.E.#64981 <br />Alexei Hidalgo, Mechanical P.E.#70807 <br />Sheet Title <br />ELECTRICAL POWER <br />PLAN RISER AND KEY <br />NOTES <br />Sheet No. <br />E-3 <br />