My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (108)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (108)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 4:08:05 PM
Creation date
2/19/2025 8:37:24 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Berglund Construction
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• CCD No. 1 Revision No. 1 Narrative <br />Project Name: AH Zephyrhills Generator Addition <br />Project No.: H-20232.00 <br />Dwg No <br />Description <br />Remarks <br />Reason for Change <br />beam elevations; Clarify HSS steel <br />around wall opening at roll -up <br />door <br />S303 <br />WALL ELEVATIONS <br />Clarify concrete tie beam <br />VE and Clarification <br />elevations and HSS steel around <br />wall openings <br />S502 <br />SCHEDULES <br />Clarify lap splice requirements <br />Clarification <br />S602 <br />FOUNDATION DETAILS <br />Remove not used retaining wall <br />VE and Clarification <br />section; Clarification of retaining <br />wall dimensions <br />Architectural Drawings <br />Dwg No <br />Description <br />Remarks <br />Reason for Change <br />Al 12 <br />FLOOR PLAN - 1 ST LEVEL - AREA 2 <br />Floor plan revised due to slab <br />Coordination <br />elevation changes in <br />maintenance room <br />Al 12D <br />DIMENSION PLAN - 1 ST LEVEL - <br />Dimension plan updated per <br />Coordination <br />AREA 2 <br />revisions to floor plan <br />A201 <br />EXTERIOR ELEVATIONS <br />H6 - Exterior door moved up to <br />Coordination <br />match height of finish floor in <br />maintenance room <br />A221 <br />BUILDING & WALL SECTIONS <br />M1 - Dimensions revised and <br />Coordination/ <br />"V.I.F." notation added for <br />Clarification <br />clarification <br />A511 <br />CEILING PLAN - 1 ST LEVEL - AREA 1 <br />Added notation for spray <br />Clarification <br />fireproof to be applied to existing <br />deck underside <br />A901 <br />DOOR LEGENDS, DETAILS <br />Revised door schedule to <br />Coordination <br />indicate door hardware set <br />information <br />Plumbing Drawings <br />Dwg No <br />Description <br />Remarks <br />Reason for Change <br />P-102 <br />PLUMBING FIRST FLOOR PLAN - <br />AREA 1 <br />Floor plan revised. Rerouted storm <br />into new shaft. <br />COORDINATION <br />Mechanical Drawings <br />Dwg No <br />Description <br />Remarks <br />Reason for Change <br />M-102-2 <br />MECHANICAL FIRST FLOOR PLAN - <br />AREA 1 <br />Floor plan revised. Added note <br />for duct in receiving area. <br />COORDINATION <br />333 South Garland Avenue ■ Suitel 100 ■ Orlando, Florida 32801 ■ 407.839.0886 ■ www.huntonbrady.com ■ #AR91515 <br />
The URL can be used to link to this page
Your browser does not support the video tag.