My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (109)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (109)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 1:19:12 PM
Creation date
2/19/2025 8:37:49 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Berglund Construction
Building Plans - Permit #
738
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 <br />I <br />3 <br />I 4 <br />5 <br />U <br />C <br />F: <br />E <br />Y <br />co <br />U <br />Ir <br />¢I <br />W <br />z <br />A <br />U <br />a <br />00 <br />CIO <br />N <br />N <br />CN <br />N <br />M <br />HEAD <br />CHASE <br />TYPE D <br />UNDERSIDE OF STRUCTURE ABOVE <br />22 GA. MTL. STUD BRACING @ 48" O.C. MAX <br />(ALTERNATE) - CONNECT EA. BRACING TO <br />DECK ABOVE W/ (4) POWER ACTUATED CONC <br />FASTENERS & TO HEAD TRACK W/ (4) 1/2" <br />SELF -TAPPING PAN HEAD SCREWS <br />CONT. HEADER TRACK SECURED @ 24" O.C. <br />CEILING AS SCHEDULED <br />(1) LAYER 5/8" G.W.B. - SECURE W/ 1" TYPE'S' <br />SCREWS, 8" O.C. TO STUDS ON JOINTS & 12" <br />O.C. TO STUDS & RUNNERS IN FIELD <br />FINISHED ROOM <br />3 5/8" METAL STUD @ 16" O.C. MAX <br />CONT. SILL TRACK SECURED TO STRUCTURE <br />@ 24" O.C. W/ 1 1/2" '10 TAPCONS OR HILTI <br />DNI 32 P.S. POWER ACTIVATED FASTNER @ <br />24" C/C MAX. <br />BASE AS SCHEDULED <br />CONT. CAULK <br />FINISH FLOOR <br />Ott rcur <br />00 <br />m <br />r <br />HEAD <br />3/4" = 1' - 0" TYPE C <br />ACT TO ACT W/ GWB SOFFIT <br />SCALE: 1 1/2" =1'41 <br />)N 3 5/8" <br />FINISH AS SCHEDULED. (TYP.) <br />EXISTING SLIDE DOOR <br />GWB PARTITION, PER PLAN <br />METAL FRAMING <br />I ! BLOCKING <br />EXISTING SLIDE DOOR — - - - - <br />- - - - FIXED PANEL/ FRAME <br />-------------- -- - -- - - -- - FEC2, SEMI -RECESSED <br />GASKET W/ ADHESIVE �� N FIRE EXTINGUISHER <br />- CABINET, PER <br />SPECIFICATIONS, AS <br />LOCATED ON PLANS <br />SHIM AS NECESSARY <br />WALL PARTIT <br />SCHE' <br />3" SOUND ATTENL <br />BLANKET WHERE SCHE <br />PARTITION TO MULLION PLAN DETAIL <br />SCALE: 3" = V-0" <br />Copyright © 2018. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />UNDERSIDE OF STRUCTURE ABOVE <br />CONTINUOUS FIRE CAULK,(BOTH SIDES) <br />CONT. HEADER TRACK SECURED TO STRUCT. <br />@ 24" O.C. W/ 1 1/2" -10 TAPCONS OR HILTI <br />DNI 32 P.S. POWER ACTIVATED FASTENER @ <br />24" C/C MAX. <br />EXTEND PARTITION TO UNDERSIDE OF <br />STRUCTURE <br />CEILING AS SCHEDULED <br />TYPE "C" SOUND ISOLATING BATT. INSULATION <br />3/4" STIFFENING CHANNEL CONT. AS REQUIRED <br />3 5/8" METAL STUD @ 16" O.C. <br />(1) LAYER 5/8" TYPE "X" G.W.B. @ EA. SIDE - <br />SECURE W/ 1" TYPE 'S' SCREWS, 8" O.C. TO <br />STUDS ON JOINTS & 12" O.C. TO STUDS & <br />RUNNERS IN FIELD <br />NOTE: <br />ASSEMBLY FIRE RESISTANCE RATING 1 HR. - <br />COMPLY WITH U.L. DESIGN NO. U465 <br />CONT. SILL TRACK SECURED TO STRUCTURE <br />@ 24" O.C. W/ 1 1/2" -10 TAPCONS OR HILTI DNI <br />32 P.S. POWER ACTIVATED FASTNER @ 24" <br />C/C MAX. <br />BASE AS SCHEDULED <br />CONT. CAULK (BOTH SIDES) <br />FINISH FLOOR <br />SEALANT, ALL SIDES <br />-Nv TOR -OF F-€. <br />i OR F.E.C. <br />HEAD <br />3/4" = 1' - 0" TYPE B <br />SEE: RCP FOR <br />ELEV. <br />ACOUSTIC CEILING <br />TILE AS SCHED._7z <br />5/8" GYPSUM WALL <br />BOARD - FINISH AS <br />SCHEDULED <br />CORNER REINFORCING, <br />TYP. AT ALL OUTSIDE <br />CORNERS (TYP.) <br />ACT TO ACT BULKHEAD <br />SCALE: 1 1/2" = V-0" <br />GWB PARTITION, PER PLANS <br />METAL FRAMING <br />BLOCKING <br />FEC2, SEMI RECESSED FIRE <br />EXTINGUISHER CABINET, PER <br />SPECIFICATIONS, AS <br />LOCATED ON PLANS <br />SHIM AS NECESSARY <br />CONT. SEALANT, <br />ALL EDGES <br />FIRE EXTINGUISHER MOUNTING DETAILS <br />SCALE: 1 1/2" = V-0" <br />UNDERSIDE OF STRUCTURE ABOVE <br />CONT. HEADER TRACK SECURED TO <br />STRUCT. @ 24" O.C. W/ 1 1/2" -10 TAPCONS <br />OR HILTI DNI 32 P.S. POWER ACTIVATED <br />FASTENER @ 24" C/C MAX. <br />EXTEND PARTITION TO UNDERSIDE OF <br />STRUCTURE <br />CEILING AS SCHEDULED <br />(1) LAYER 5/8" G.W.B. @ EA. SIDE - SECURE <br />W/ 1" TYPE 'S' SCREWS, 8" O.C. TO STUDS <br />ON JOINTS & 12" O.C. TO STUDS & RUNNERS <br />IN FIELD <br />BATT. INSULATION <br />3 5/8" METAL STUD @ 16" O.C. <br />3/4" STIFFENING CHANNEL CONT. AS REQUIRED <br />CONT. SILL TRACK SECURED TO STRUCTURE <br />@ 24" O.C. W/ 1 1/2" -10 TAPCONS OR HILTI DNI <br />32 P.S. POWER ACTIVATED FASTNER @ 24" <br />C/C MAX. <br />BASE AS SCHEDULED <br />CONT. CAULK (BOTH SIDES) <br />FINISH FLOOR <br />to <br />HEAD <br />UNDERSIDE OF STRUCTURE ABOVE <br />22 GA. MTL. STUD BRACING @ 48" O.C. MAX <br />(ALTERNATE) - CONNECT EA. BRACING TO <br />DECK ABOVE W/ (4) POWER ACTUATED CONC <br />FASTENERS & TO HEAD TRACK W/ (4) 1/2" <br />SELF -TAPPING PAN HEAD SCREWS <br />CEILING AS SCHEDULED <br />CONT. HEADER TRACK SECURED @ 24" <br />O.C. <br />(1) LAYER 5/8" G.W.B. @ EA. SIDE -SECURE <br />W/ 1" TYPE 'S' SCREWS, 8" O.C. TO STUDS <br />ON JOINTS & 12" O.C. TO STUDS & RUNNERS <br />IN FIELD <br />TYPE "C" SOUND ISOLATING BATT <br />INSULATION <br />CONT. SILL TRACK SECURED TO STRUCTURE <br />@ 24" O.C. W/ 1 1/2" '10 TAPCONS OR HILTI DNI <br />32 P.S. POWER ACTIVATED FASTNER @ 24" <br />C/C MAX. <br />BASE AS SCHEDULED <br />CONT. CAULK <br />FINISH FLOOR <br />3/4" = 1' - 0" TYPE A 3/4" = 1' - 0" <br />METAL FRAMING TO <br />STRUCTURE ABOVE <br />3-5/8" MTL HEADER, TYP. <br />ACOUSTIC CEILING <br />TILE AS SCHED. <br />PLAN <br />5/8" G.W.B. @ EA. SIDE <br />ATTACH STUD @ STL. COL. W/ 2 1/2" STL. <br />SCREWS @ TOP, BOTTOM, AND MID POINT <br />TUBE STEEL BRACING COL. 3"X3" X 1/2" W/ 3"X9" <br />X 1/2" WELDED BASE PLATE. SECURE BASE <br />PLATE TO NEW CONC. FLOOR SLAB WITH <br />(2) 3/4"X 2" EXPANDED "KW IK BOLTS" <br />0 <br />3 5/8" METAL STUD FRAMING @ 16" O.C. <br />CONT. CORNER BEAD @ ALL OUTSIDE CORNERS <br />14 GA TYPE 304 ST. STL W/ #4 FINISH CAP <br />2 X 6 CONT. NAILER FASTENED TO MTL. CHANNEL TRACK <br />CONT. SEALANT BOTH SIDES <br />5/8" G.W.B. @ EA. SIDE WITH WP-1 WALL PROTECTION. <br />SEE FINISH SCHEDULE <br />TUBE STEEL BRACING COL. 3"X3" X 1/2" W/ 3"X9" X1/2" <br />WELDED BASE PLATE. SECURE BASE PLATE TO <br />NEW CONC. FLOOR SLAB WITH (2) 3/4"X2" <br />EXPANDED "KWIK BOLTS" <br />3 5/8" METAL STUD FRAMING @ 16" O.C. <br />CONT. SILL TRACK SECURED TO STRUCTURE @ <br />24" O.C. W/ 1 1/2" *10 TAPCONS OR HILTI DNI 32 <br />P.S. POWER ACTIVATED FASTNER @ 16" C/C <br />MAX. <br />� � BASE AS SCHEDULED <br />.!CONT. FIRE CAULK (BOTH SIDES) <br />FINISH FLOOR <br />SECTION <br />TYPE E 3/4" = 1' - 0" <br />GENERAL PARTITION NOTES <br />1. ALL STUD GAUGES AND LIMITING HEIGHTS IN <br />GYPSUM WALL BOARD REFERENCE <br />SPECIFICATIONS. <br />2. ALL PARTITIONS CONTAINING PLUMBING OR <br />HAVING AN EXTERIOR FACE TO BE INSULATED. <br />3. THE FOLLOWING LIST OF ROOMS (IF USED) <br />SHALL HAVE THEIR PERIMETER PARTITIONS <br />INSULATED USING MINERAL WOOL: <br />a. ALL ROOMS ENCLOSED WITH RATED <br />PARTITIONS <br />4. THE FOLLOWING LIST OF ROOMS (IF USED) <br />SHALL HAVE THEIR PERIMETER PARTITIONS <br />INSULATED WITH SOUND ATTENUATION BATTS AS <br />SPECIFIED: <br />a. TOILET ROOMS <br />b. OFFICES <br />c. EXAM ROOMS <br />d. CONFERENCE ROOMS <br />5. ALL RATED PARTITIONS TO EXTEND FROM TOP <br />OF SLAB TO UNDERSIDE OF STRUCTURE. SEAL <br />TOP AND BOTTOM TYPICAL. <br />6. ALL INTERIOR ROOF DRAINS AND OVERFLOW <br />DRAINS TO BE WRAPPED CONTINUOUSLY WITH <br />SOUND ATTENUATION INSULATION. <br />7. REFER TO PLANS FOR LOCATION OF PARTITION <br />TYPES. "A" IS THE TYPICAL PARTITION TYPE UNLESS <br />NOTED OTHERWISE. <br />8. UNDERSIDE OF STRUCTURE INDICATED AT HEAD <br />CONDITION FOR EACH PARTITION TYPE IS <br />DIAGRAMMATIC ONLY, AND DOES NOT INDICATE <br />EXACT CONSTRUCTION CONDITIONS. <br />9. INSTALL FRAMING AND GYPSUM WALL BOARD TO <br />OFFSET AROUND STRUCTURAL MEMBERS OR <br />OTHER OBSTRUCTIONS TO MAINTAIN FIRE <br />RESISTIVE RATINGS. <br />10. WHERE GYPSUM WALL BOARD EXTENDS TO <br />THE UNDERSIDE OF STRUCTURE, STOP GYPSUM <br />WALL BOARD'/2 BELOW LINE OF STRUCTURE AND <br />SEAL AS REQUIRED. <br />11. FIRE RESISTANT, RATED PARTITIONS TO BE <br />INSTALLED WITH FIRESTOP SEALANT, UNLESS <br />NOTED OTHERWISE. <br />12. NON -RATED PARTITIONS TO BE INSTALLED WITH <br />ACOUSTICAL SEALANT, UNLESS NOTED <br />OTHERWISE. <br />13. REFER TO MECHANICAL DRAWINGS FOR <br />DETAILS ON PIPE PENETRATIONS THROUGH <br />ACOUSTICAL PARTITIONS AS WELL AS RATED <br />PARTITIONS. <br />14. INSTALL FIRE RETARDANT, TREATED BLOCKING <br />IN PARTITIONS AS REQUIRED ON DRAWINGS. <br />15. ALL PARTITIONS SCHEDULED TO RECEIVE TILE <br />OR FRP, SHALL BE CONSTRUCTED OF WATER- <br />RESISTANT CORE GYPSUM WALL BOARD. <br />16. PER RS&H MOLD PREVENTION GUIDELINES, DO <br />NOT INSTALL GYPSUM WALL BOARD IN DIRECT <br />CONTACT WITH THE FLOOR. ALL PARTITIONS SHALL <br />BE SHIMMED'/2 OFF THE FLOOR WITH NON -POROUS <br />SHIMS. PLASTIC NON -POROUS HORSESHOE SHIMS <br />ARE RECOMMENDED. GYPSUM WALL BOARD SHIMS <br />ARE NOT ACCEPTABLE. SEAL WITH ACOUSTIC <br />SEALANT AT NON -RATED WALLS. SEAL WITH FIRE <br />RATED SEALANT AT RATED WALLS. <br />CLOSE CEILING SPACE W/ <br />5/8" TYPE "X" GYP. WALL <br />BD. SEAL ALL JOINTS & MTL. STUD FRAMING <br />CLOSE CEILING SPACE W/ PENETRATIONS & <br />POLYTHENE MEMBRANE PERIMETER W/ DUCT <br />TAPE <br />SEAL AROUND ALL PIPE riSEAL AROUND ALL PIPE <br />& DUCT & DUCT PLASTER TAPE ALL JOINTS, <br />PLASTER TAPE ALL JOINTS, PENETRATIONS. HIGH TACK SPRAY OR EQUAL <br />PENETRATIONS. <br />SECURE ALL TAPE W/ HIGH TACK SPRAY OR EQUAL SECURE ALL TAPE W/ <br />ON <br />RAM -TACK IN THE 5/8" TYPE "X' GYP. BD. ON 3-5/8" RAM -TACK IN THE 3-5/ TYPE . S GYP. BD. IN <br />( ) PARTITION &POLY 3-5/8" MTL. STUD FRAMING <br />PARTITION & POLY MTL. STUD FRAMING 1-HR. . <br />BARRIER W/ DUCT TAPE FINISH OCCUPIED SIDE W/ BARRIER W/ DUCT TAPE A.I.(1-HR.). FINISH OCCUPIED <br />ENOVATED SID OCCUPIED @b2SS PAINT IDE W/ GLOSS PAINT <br />PROVIDE 20 MIN. RATED PROVIDE 20 MIN. RATED RENOVATED SID OCCUPIED SIDES <br />DOOR IN RATED FRAME IF TYPE "C" SOUND DOOR IN RATED FRAME IF TYPE "C" SOUND <br />ACCESS DOORS ARE X ISOLATING BATT ACCESS DOORS ARE ISOLATING BATT <br />INSTALLED INSULATION INSTALLED INSULATION <br />CONT. 35/8" SILL TRACK CONT. 35/8" SILL <br />SECURED TO FLOOR EXISTING FLOOR TRACK SECURED TO EXISTING FLOOR <br />FLOOR <br />ALTERNATE TEMPORARY 1 HR. PARTITION � TEMPORARY 1 HR. PARTITION <br />SCALE: 3/4" = V-0" <br />SCALE: 3/4" = V-0" <br />RS&H <br />1715 N. Westshore Blvd., Suite 600 <br />Tampa„ Florida 33607-3999 <br />904-256-2500 Fax 904-256-2503 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886' IB26000956 <br />5620 - LCC000210 - GB238 <br />Advent Hea Ith <br />PROJECT TITLE: <br />KITCHEN RENOVATION <br />ADVENTHEALTH ZEPHYRHILLS <br />PROJECT ADDRESS: <br />7050 Gall Blvd. Zephyrhills, FL 33541 <br />SEAL <br />,�Op—JIN 1(14f <br />. <br />M <br />AR95652 :� <br />c <br />•. . �� <br />C)F <br />TFREI;�eFtG� <br />N <br />�9-d by Yoo-Jin <br />Q <br />DN: C=US, <br />Yoo-JIn Kim E yoo-jinkm®rsandncom <br />O.RSH. CN=Yoo-Jim Kim <br />O <br />♦ ♦ <br />V <br />Date: 20M04.08 <br />09:41:02-04'00' <br />Z <br />W_ <br />SIGNATURE <br />J <br />c� <br />x <br />a <br />REVISIONS <br />NO. DESCRIPTION DATE <br />DATE ISSUED: 03/20/2020 <br />REVIEWED BY: YK <br />DRAWN BY: YK/KN <br />DESIGNED BY: <br />PROJECT NUMBER: <br />504- 0226- 000 <br />0 2019 RS&H, INC. <br />SHEET TITLE: <br />PARTITION TYPES & <br />DETAILS <br />SHEET ID: <br />A501 <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />4 <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.