Laserfiche WebLink
, I 1 11 1 1 13 s R"I i I 1. 19 11..1 -WIN..,1w Mug _1,1 1 11! 1 ' !.1 'I' I 1 111TIVIRI, I i <br />1 I 2 I 3 I 4 <br />a <br />rn <br />N <br />tf <br />CM <br />to <br />O <br />N <br />0 <br />Q <br />LO <br />N <br />co <br />PLUMBING SPECIFICATIONS` <br />1.00 - GENERAL PROVISIONS <br />1.01 PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT FOR A COMPLETE AND PROPERLY OPERATING <br />PLUMBING SYSTEM. <br />1.02 CODES AND STANDARDS: ALL PLUMBING WORK SHALL BE IN STRICT COMPLIANCE WITH THE 2017 <br />FLORIDA PLUMBING CODE AND ALL LOCAL CODES HAVING JURISDICTION. <br />1.03 ALL PLUMBING WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. CONTRACTOR <br />SHALL SECURE AND PAY FOR ALL PERMITS AND FEES, ETC., REQUIRED FOR THE EXECUTION OF <br />THIS WORK. <br />1.04 CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES BEFORE FABRICATION OR <br />INSTALLATION. OFFSETS AND/OR TRANSITIONS REQUIRED SHALL BE PROVIDED WITHOUT <br />ADDITIONAL COST. CONTRACTOR SHALL COORDINATE AND INSTALL HIS WORK IN A TIMELY <br />MANNER TO PREVENT DELAYS IN THE CONSTRUCTION. <br />1.05 CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR OR REPLACE DAMAGED EQUIPMENT AND/OR <br />MATERIAL. <br />1.06 PROVIDE ALL MATERIALS REQUIRED TO PROPERLY SUPPORT ALL PIPING ANDEQUIPMENT. PIPE <br />HANGERS SHALL BE ADJUSTABLE TYPE AND BE SPACED IN ACCORDANCE WITH THE FLORIDA <br />PLUMBING CODE. PROVIDED PLASTIC COATED RING ON HANGERS FOR COPPER PIPING TO <br />PROVIDE DIELECTRIC ISOLATION. <br />1.07 PROVIDE DIELECTRIC UNIONS OR FLANGES BETWEEN COPPER AND STEEL PIPING AND BETWEEN <br />BRASSWARE AND STEEL. DO NOT USE STEEL AND COPPER PIPING IN THE SAME SYSTEM <br />WITHOUT SUCH ISOLATION. <br />1.08 PROVIDE REDUCING FITTINGS (REDUCING BUSHINGS SHALL NOT BE USED) WHERE CHANGES IN <br />PIPE SIZES OCCUR. <br />1.09 THIS CONTRACTOR SHALL SUPPLY AND INSTALL ALL SERVICES THROUGHOUT THE BUILDING AND <br />MAKE CONNECTION TO SITE UTILITIES APPROXIMATELY 6-0" OUTSIDE THE BUILDING. <br />CONTRACTOR SHALL SUPPLY AND INSTALL FIXTURES, FITTINGS, VALVING AND TRIM AND MAKE <br />READY FOR USE ALL FIXTURES, EQUIPMENT, ETC. <br />1.10 SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. <br />2.00 - BASIC MATERIALS AND METHODS <br />2.01 DOMESTIC WATER - ABOVEGROUND WATER PIPE AND FITTINGS - TYPE "L" COPPER. <br />2.02 PROVIDE UNIONS OR FLANGES IN ALL DOMESTIC WATER SERVICE LINES AT EACH PIECE OF <br />EQUIPMENT, SPECIALTY VALVES OR AT OTHER LOCATIONS REQUIRED FOR READY DISCONNECT. <br />2.03 WATER HAMMER ARRESTORS SHALL BE INSTALLED AT THE LOCATIONS ON THE PLANS AND IN <br />ACCORDANCE WITH PDI STANDARD WH-201. PRODUCTS SHALL BE EQUAL TO THOSE <br />MANUFACTURED BY PRECISION PLUMBING PRODUCTS OR SIOUX CHIEF. <br />2.04 VALVES: PROVIDE VALVES TO ISOLATE EACH RISER, BRANCH LINE AND PIECE OF EQUIPMENT. <br />2.05 PROVIDE PRESSURE REDUCING VALVE AND AIR GAP CONNECTION AT DISHWASHER AS REQUIRED <br />BY CODE AND ACCORDING TO MANUFACTURER. <br />2.06 PROVIDE INLINE WATER FILTER AT WATER DISPENSERS, COFFEE MAKER AND ICE MAKER TO <br />REMOVE MATERIALS, TASTE AND ODOR - "EVERPURE OR "SYSTEMS W. <br />2.07 SANITARY WASTE (NON -PRESSURE), SANITARY VENT AND STORM PIPING - ABOVE GROUND - PVC <br />SCH40 DWV PIPE AND FITTINGS. <br />2.08 CONDENSATE PIPING - PVC SCH-40 DWV PIPE AND FITTINGS. <br />2.09 INSTALL GRAVITY LINES SLOPED AT 1/8" PER FOOT FOR PIPE 3" AND LARGER AND 1/4+' PER FOOT <br />FOR PIPE SMALLER THAN 3". VERIFY INVERT ELEVATION WITH EXISTING PIPING PRIOR TO ANY <br />PIPE BEING INSTALLED. <br />2.10 PROVIDE AND PROPERLY LOCATE HANGERS TO ADEQUATELY SUPPORT PIPING. ARRANGE <br />HANGERS TO PERMIT EXPANSION AND CONTRACTION. DO NOT HANG PIPING FROM FIRE OR <br />SMOKE WALLS. PROVIDE PIPE HANGERS AT EACH VALVE, STRAINER, AND OTHER PIPING <br />ACCESSORY, AND AT EACH CHANGE OR DIRECTION. <br />2.11 THE SIZE OF HANGERS FOR NON -INSULATED PIPES SHALL BE SUITABLE FOR THE PIPE SIZE TO BE <br />SUPPORTED. FOR INSULATED PIPING, THE SIZE OF THE HANGER SHALL BE SUITABLE FOR THE <br />PIPE SIZE, PLUS THE INSULATION AND INSULATION SHIELD. <br />EXISTING WALL HUNG SINK <br />2.12 SPACING: LOCATE PIPE SUPPORTS AS INDICATED IN THE FOLLOWING TABLE: <br />HORIZONTAL PIPE HANGER SCHEDULE <br />MATERIAL <br />PIPE SIZE <br />HANGER SPACING <br />COPPER TUBING <br />UP T01 114 INCH <br />1 1/2 INCH AND ABOVE <br />6 FOOT CENTERS <br />10 FOOT CENTERS <br />CAST IRON PIPE <br />ALL <br />5 FOOT CENTERS <br />3.00 - PLUMBING FIXTURES AND TRIM <br />3.01 ALL PLUMBING FIXTURES SHALL BE "FIRST QUALITY" AS DEFINED AND SET FORTH IN COMMERCIAL <br />STANDARD CS77-28 AS PROMULGATED BY THE U.S. DEPARTMENT OF COMMERCE. <br />3.02 ALL FIXTURES ARE TO BE WHITE VITREOUS CHINA UNLESS OTHERWISE SPECIFICALLY NOTED. <br />FIXTURES AND FITTINGS PROPOSED SHALL BE FROM ONE MANUFACTURER AND OF SIMILAR <br />CHARACTER IN ANY ROOM OR LOCATION. ESCUTCHEONS, HANDLES, ETC., ON THE DIFFERENT <br />FIXTURES SHALL BE OF THE SAME DESIGN. <br />3.03 PROVIDE FIXTURE CARRIERS AS RECOMMENDED BY FIXTURE MANUFACTURER AND/OR <br />CONSTRUCTION METHOD. <br />3.04 PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NON -ACCESSIBLE CEILINGS. <br />REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. <br />3.05 FLOOR DRAIN TRAP SEALS SHALL HAVE AN APPROVED PRIMING DEVICE DESIGNED FOR THAT <br />PURPOSE. <br />3.06 ALL CONCEALED TRAPS, PRIMERS, VALVES, CLEANOUTS, ETC. LOCATED IN TILED AREAS SHALL BE <br />PROVIDED WITH AN ACCESS PANEL. <br />4.00 - INSULATION <br />4.01 ABOVE GROUND COLD AND HOT WATER PIPING - FIBERGLASS, 1" THICKNESS, ASJ JACKET, <br />DOUBLE SEALING LAP JOINT, 0.24 K AT 75°F. INSULATION AND ADHESIVES INSTALLED IN RETURN <br />AIR PLENUMS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE <br />DEVELOPED RATING OF 50. <br />4.02 ABOVE GROUND STORM PIPING - FIBERGLASS, 1/2" THICKNESS, ASJ JACKET, DOUBLE SEALING LAP <br />JOINT, 0.24 K AT 757. INSULATION AND ADHESIVES INSTALLED IN RETURN AIR PLENUMS SHALL <br />HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF <br />50. <br />4.03 ABOVEGROUND CONDENSATE PIPING SHALL BE 1/2" FLEXIBLE UNICELLULAR POLYOLEFIN FOAM <br />AND SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED <br />RATING OF 50-IMCOA "IMCOLOCK". <br />5.00 - VALVES AND COCKS <br />5.01 VALVES 2" AND SMALLER SHALL BE BALL VALVES, 150 PSI SWP, 400 PSI WOG. STANDARD PORT <br />BALL, BRONZE TRIM, CAST BRONZE BODY, CHROMIUM -PLATED BRASS BALL, BRONZE NON - <br />BLOWOUT STEM, TEFLON SEAT, DOUBLE 0-RING STEM SEALS, ZINC -COATED STEEL HANDLE WITH <br />PLASTIC COATED HAND GRIP, 90 DEGREE OPERATION FROM FULL OPEN TO TIGHT SHUT-OFF - <br />STOCKHAM S214-BR-T-T, STOCKHAM S216-BR-T-S OR EQUAL. <br />5.02 CHECK VALVES, ROUGH BRASS, REGRINDING BRONZE DISC - STOCKHAM B-345; B-309 OR EQUAL. <br />6.00 - STERILIZATION <br />6.01 DOMESTIC WATER PIPING SHALL BE THOROUGHLY FLUSHED OUT AND STERILIZED IN <br />ACCORDANCE WITH THE FLORIDA PLUMBING CODE. <br />PLUMBING FIXTURE SCHEDULE <br />CHROME PLATED CAST BRASS GRID STAINER WITH 1-1/4" O.D. OFFSET TAILPIECE, CHROME PLATED <br />17 GAUGE 1-1/4"X1-1/2" BRASS P-TRAP W/ CLEANOUT PLUG AND SLIP NUTS. PROVIDE P-TRAP AND <br />TAILPIECE WITH PREWRAPPED SEAMLESS MOLDED CLOSED CELL VINYL INSULATION WITH FLEXIBLE <br />COLLARS TO ALLOW PIPE CONNECTION. PRE -WRAPPED DRAIN INSULATION KIT SHALL INCLUDE HOT <br />AND COLD ANGLE STOPS AND WATER SUPPLY COVERS OF SAME MATERIAL. <br />3/8" I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT BRASS DEEP <br />BELL FLANGE ESCUTCHEON AND 1/2" CHROME PLATED COPPER EXTENSION TUBE. <br />CONCEALED ARMS FLOOR MOUNTED CARRIER: COATED STEEL UPRIGHTS WITH WELDED FEET, CAST <br />IRON ADJUSTABLE HEADERS, STEEL SLEEVES, ALIGNMENT TRUSS AND FASTENERS. <br />BASIS OF DESIGN <br />SINK - EXISTING FOR REUSE <br />FAUCET - EXISTING FOR REUSE <br />STRAINERITRAP - MCGUIRE 155WC/PW 2150 WC (PROVIDE NEW) <br />SUPPLIES - MCGUIRE H170LK (PROVIDE NEW) <br />CARRIER - ZURN ZR-1231 (PROVIDE NEW) <br />EXISTING TRIPLE COMPARTMENT SINK <br />CHROME PLATED CAST BRASS GRID STAINER WITH 1-1/4" O.D. OFFSET TAILPIECE, CHROME PLATED <br />17 GAUGE 1-1/4"X1-1/2" BRASS P-TRAP W/ CLEANOUT PLUG AND SLIP NUTS. PROVIDE P-TRAP AND <br />TAILPIECE WITH PREWRAPPED SEAMLESS MOLDED CLOSED CELL VINYL INSULATION WITH FLEXIBLE <br />COLLARS TO ALLOW PIPE CONNECTION. PRE -WRAPPED DRAIN INSULATION KIT SHALL INCLUDE HOT <br />AND COLD ANGLE STOPS AND WATER SUPPLY COVERS OF SAME MATERIAL. <br />3/8" I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT BRASS DEEP <br />BELL FLANGE ESCUTCHEON AND 1/2" CHROME PLATED COPPER EXTENSION TUBE. <br />CONCEALED ARMS FLOOR MOUNTED CARRIER: COATED STEEL UPRIGHTS WITH WELDED FEET, CAST <br />IRON ADJUSTABLE HEADERS, STEEL SLEEVES, ALIGNMENT TRUSS AND FASTENERS. <br />BASIS OF DESIGN <br />SINK - EXISTING FOR REUSE <br />FAUCET - EXISTING FOR REUSE <br />STRAINER/TRAP - MCGUIRE 155WC/PW 2150 WC (PROVIDE NEW) <br />SUPPLIES - MCGUIRE H170LK (PROVIDE NEW) <br />MOP SINK <br />FLOOR SINK <br />PRECAST TERRAllO WITH STAINLESS STEEL CAP, 24"x24N12" TERRAllO SHALL BE MADE OF GREY <br />12"X12"X10" DEEP CAST IRON BODY WITH WHITE ACID RESISTING PORCELAIN ENAMEL INTERIOR, ALUMINUM <br />MARBLE CHIPS CAST IN WHITE PORTLAND CEMENT TO PRODUCE A COMPRESSIVE STRENGTH OF NOT <br />ANTI -SPLASH INTERIOR BOTTOM DOME STRAINER AND NICKEL BRONZE TOP. <br />LESS THAN 3,000 PSI. TERRAllO SURFACE SHALL BE GROUND AND POLISHED WITH ALL AIR HOLES <br />AND/OR PITS TO BE GROUTED AND EXCESS REMOVED. DRAIN BODY SHALL BE STAINLESS STEEL CAST <br />BASIS OF DESIGN <br />INTEGRAL, AND SHALL PROVIDE FOR A CAULKED LEAD CONNECTION AND NOT LESS THAN 1" DEEP TO <br />A 3" PIPE. <br />ZURN - Z1902T <br />TYPE 304, 20-GAUGE STAINLESS STEEL SPLASH PANELS, 12" HEIGHT SECURED TO WALL ON 2 SIDES, <br />TRENCH DRAIN <br />SERVICE FAUCET SHALL BE CHROME PLATED WITH REVNEWABLE SEATS IN MONEL, VACUUM BREAKER, <br />INTEGRAL STOPS AND SPRING CHECK VALVES, ADJUSTABLE WALL BRACE, PAIL HOOK, AND 3/4" HOSE <br />A <br />12" WIDE TOP MODULAR, HEAVY DUTY TRENCH DRAIN <br />THREAD ON SPOUT. <br />BASIS OF DESIGN <br />BASIS OF DESIGN <br />ZURN - Z665 <br />SINK - WILLIAMS SBC-1700-2-BP <br />FAUCET - T&S BRASS-B-0665-BST'P <br />CART WASH <br />8" WALL MOUNT MIXING FAUCET WITH POLISHED CHROME PLATED BRASS BODY, 90 DEGREE SWIVEL WITH <br />WATER SOFTENER <br />VACUUM BREAKER, 44" FLEXIBLE STAINLESS STEEL HOSE WITH HEAT RESISTANT HANDLE,1.15 GPM ANGLED <br />SPRAY VALVE, COMPRESSION CARTRIDGES WITH SPRING CHECKS, LEVEL HANDLES, 1/2" NPT FEMALE INLETS <br />MIN FLOW (GPM) - 2.79 <br />AND SPRAY VALVE HOLDER. CERTIFIED TO ASME Al 12.18.1/CSA B125.1, NSF 61 SECTION 9 AND NSF372.2019 <br />SERVICE FLOW (GPM, 15 PSI) - 56 <br />DOE PRSV - CLASS II COMPLIANT. <br />CAPACITY (KGRAINS) -120 <br />120 V CONNECTION PER VESSEL <br />BASIS OF DESIGN <br />BASIS OF DESIGN <br />T&S BRASS - B-0167-HH <br />EVOQUA- PTCSSD07-16x65T B <br />PLUMBING SYMBOL LEGEND <br />SYMBOL DESCRIPTION <br />=====AV==== <br />AW <br />-----AW==== <br />CO2 <br />CA <br />CD <br />=====CD==== <br />DA <br />DI <br />DV <br />FOF <br />FOG <br />FOR <br />FOS <br />====-FOV===- <br />Ci K <br />MA <br />MV <br />NI <br />N20 <br />OX <br />ST <br />=====ST===== <br />STO <br />=====STO===- <br />M <br />11 C - <br />- - <br />001 <br />Coll <br />CO I' 0 <br />CO <br />FD EC <br />FD CC - <br />CO <br />FS IC <br />i <br />G <br />Y <br />G <br />C <br />_MML AP-XX <br />_EZ�L MAP-XX <br />11 MGO-XX <br />III III MGV-XX <br />1 <br />P2.01 <br />- ACID VENT <br />- ACID WASTE <br />- BELOW GROUND ACID WASTE <br />- CARBON DIOXIDE <br />- COMPRESSED AIR <br />- ABOVE GROUND CONDENSATE DRAIN <br />- BELOW GROUND CONDENSATE DRAIN <br />- DENTAL AIR <br />- DEIONIZED WATER <br />- DENTAL VACUUM <br />- DOMESTIC COLD WATER <br />- DOMESTIC HOT WATER <br />- DOMESTIC HOT WATER RETURN <br />- FUEL OIL FILL <br />- FUEL OIL GAGE <br />- FUEL OIL RETURN <br />- FUEL OIL SUPPLY <br />- FUEL OIL VENT <br />-GAS <br />- KITCHEN WASTE (GREASE) <br />- MEDICAL COMPRESSED AIR <br />- MEDICAL VACUUM <br />- NITROGEN <br />- NITROUS OXIDE <br />-OXYGEN <br />- ABOVE GROUND SANITARY <br />-BELOW GROUND SANITARY <br />- SANITARY VENT <br />- ABOVE GROUND STORM <br />- BELOW GROUND STORM <br />- OVERFLOW STORM DRAIN <br />- BELOW GROUND OVERFLOW STORM <br />- SOFT COLD WATER <br />- WATER METER <br />- HOSE BIBB OR WALL HYDRANT <br />- CLEAN OUT PLUG <br />- WALL CLEANOUT <br />- WALL CLEANOUT <br />- FLOOR CLEAN OUT <br />- FLOOR DRAIN <br />- ROOF DRAIN <br />- FLOOR SINK <br />- SHUT-OFF VALVE IN VALVE BOX <br />- SHUTOFF VALVE <br />- BALL VALVE <br />- CALIBRATED BALANCING VALVE <br />- CHECK VALVE (SWING) <br />- PRESSURE REDUCING VALVE ' <br />- SOLENOID OPERATED VALVE <br />- REDUCED PRESSURE BACKFLOW PREVENTER <br />- RELIEF OR SAFETY VALVE <br />- GAS COCK <br />- GAS PRESSURE REGULATOR <br />- SHUTOFF VALVE ON RISER <br />- GAS COCK ON RISER <br />- CONNECTION, TOP <br />- CONNECTION, BOTTOM <br />- ELBOW, TURNED DOWN <br />- ELBOW, TURNED UP <br />- TEE, TURNED UP <br />- TEE, TURNED DOWN <br />-CAP <br />- DIRECTION OF FLOW <br />-ALARM PANEL <br />- MASTER ALARM PANEL <br />- MEDICAL GAS OUTLET <br />- MEDICAL GAS VALVE BOX <br />- CONNECT TO EXISTING <br />- DEMOLISH TO POINT INDICATED <br />- REVISION REFERENCE <br />- DETAIL REFERENCE: TOP -DETAIL#, <br />BOTTOM -DRAWING# SHOWN ON <br />PLUMBING ABBREVIATIONS <br />SYMBOL <br />DESCRIPTION <br />CA <br />- COMPRESSED AIR <br />AFF <br />-ABOVE FINISH FLOOR <br />AW <br />- ACID WASTE <br />AV <br />- ACID VENT <br />CO2 <br />- CARBON DIOXIDE <br />CB <br />- CATCH BASIN <br />CD <br />- CONDENSATE DRAIN <br />CFH <br />- CUBIC FEET PER HOUR <br />CO <br />-CLEANOUT <br />CONT <br />- CONTINUATION <br />CW <br />- DOMESTIC COLD WATER <br />DI <br />- DEIONIZED WATER <br />DN <br />- DOWN <br />DS <br />- DOWNSPOUT <br />DWG <br />- DRAWING <br />EXIST <br />- EXISTING <br />OF <br />- DEGREE FAHRENHEIT <br />FCO <br />- FLOOR CLEANOUT <br />FD <br />- FLOOR DRAIN <br />FOF <br />- FUEL OIL FILL <br />FOG <br />- FUEL OIL GAGE <br />FOR <br />- FUEL OIL RETURN <br />FOS <br />- FUEL OIL SUPPLY <br />FOV <br />- FUEL OIL VENT <br />FS <br />- FLOOR SINK <br />G <br />-GAS <br />GPH <br />- GALLONS PER HOUR <br />GPM <br />- GALLONS PER MINUTE <br />GR <br />- KITCHEN WASTE (GREASE) <br />HB <br />- HOSE BIBB <br />HD <br />- HUB DRAIN <br />HW <br />- DOMESTIC HOT WATER <br />HWR <br />- DOMESTIC HOT WATER RECIRCULATING <br />IE <br />- INVERT ELEVATION <br />IW <br />- INDIRECT WASTE <br />KW <br />- KILOWATT <br />LBS <br />-POUNDS <br />MA <br />- MEDICAL AIR <br />MV <br />- MEDICAL VACUUM <br />MH <br />-MANHOLE <br />NI <br />- NITROGEN <br />N20 <br />- NITROUS OXIDE <br />NC <br />- NORMALLY CLOSED <br />NIC <br />- NOT IN CONTRACT <br />NO <br />- NORMALLY OPEN <br />NP <br />- NON -POTABLE WATER <br />NTS <br />- NOT TO SCALE <br />OD <br />- OUTSIDE DIAMETER <br />OX <br />-OXYGEN <br />PRV <br />- PRESSURE REDUCING VALVE <br />PSI <br />- POUNDS PER SQUARE INCH <br />PVC <br />- POLYVINYL CHLORIDE PIPE <br />RD <br />- ROOF DRAIN <br />RPBP <br />- REDUCED PRESSURE BACKFLOW PREVENTO <br />S <br />- SANITARY <br />SF <br />- SQUARE FEET <br />SH <br />-SHEET <br />ST <br />-STORM <br />STO <br />- OVERFLOW STORM DRAIN <br />SW <br />- SOFT COLD WATER <br />V <br />-VENT <br />VC <br />- VACUUM CLEANING <br />VTR <br />- VENT THRU ROOF <br />WCO <br />- WALL CLEANOUT <br />WTR <br />- WATER <br />CODES AND STANDARDS <br />FLORIDA BUILDING CODE 6TH EDITION - 2017 EDITION <br />NFPA #99, HEALTHCARE FACILITIES CODE - 2015 <br />EDITION. <br />GUIDELINES FOR DESIGN AND CONSTRUCTION. <br />FLORIDA HEALTHCARE FACILITIES - 2014 EDITION. <br />ALL LOCAL CODES - LATEST EDITION. <br />NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT <br />GENERAL NOTES <br />1. REFERENCE THE SPECIFICATIONS FOR MATERIAL AND EQUIPMENT INSTALLATION <br />STANDARDS. <br />2. THE PLUMBING INSTALLATION SHALL COMPLY WITH ALL STATE AND LOCAL CODES. <br />3. UTILITIES AND SERVICES INDICATED ARE TAKEN FROM VARIOUS OLD AND NEW <br />SURVEYS, AS -BUILT RECORDS AND FIELD INVESTIGATIONS. UNFORSEEN CONDITIONS <br />PROBABLY EXIST AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON <br />DRAWINGS. COOPERATION WITH OTHER TRADES IN ROUTING AND BURIAL DEPTHS, AS <br />DETERMINED DURING CONSTRUCTION, WILL BE NECESSARY. <br />4. FIELD VERIFY EXISTING INSTALLATIONS. MODIFY EXISTING PLUMBING SYSTEMS, WHICH <br />ARE TO REMAIN ACTIVE, TO FACILITATE RECONNECTION AND EXTENSION OF THE NEW <br />WORK. <br />5. NOTIFY OWNER AT LEAST 72 HOURS PRIOR TO INTERRUPTING EXISTING SERVICE. <br />SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZE DISRUPTION OF SERVICES. <br />SERVICES ARE NOT TO BE LEFT DISRUPTED DURING NON -NORMAL CONTRACTOR <br />WORKING HOURS. <br />6. PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS <br />NOT INTENDED TO INDICATE EXACT ROUTING. CONTRACTOR SHALL PROVIDE ANY <br />ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO <br />MAINTAIN CLEARANCES. VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL <br />INSTALLATIONS AND OTHER POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOID <br />INTERFERENCES. <br />7. PROVIDE ALL OFFSETS AND FITTINGS AND MAKE CONNECTION TO SITE UTILITIES. <br />8. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL <br />ROOMS OR AS SPECIFICALLY NOTED. <br />9. PROVIDE ACCESS PANELS FOR ALL VALVES CONCEALED IN WALLS OR ABOVE NON - <br />ACCESSIBLE CEILINGS. <br />10. SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND <br />FLOORS WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR <br />EXCEED THE RATING OF THE WALL, CEILING OR FLOOR. SEE ARCHITECTURAL DRAWINGS <br />FOR FINAL FINISHES. <br />11. FLASH AND COUNTER -FLASH ROOF PENETRATIONS. SEE ARCHITECTURAL DRAWINGS <br />FOR DETAILS. <br />12. WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATE PENETRATIONS <br />WITH ALL TRADES, THE ARCHITECT AND THE STRUCTURAL ENGINEER. <br />13. PROVIDE FOUNDATION PAD PENETRATION SLEEVES. ALLOW 1" MINIMUM CLEARANCE <br />BETWEEN SLEEVE INSIDE SURFACE AND PIPE EXTERIOR. <br />14. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. <br />15. PROVIDE AUTOMATIC TRAP PRIMERS FOR FLOOR DRAIN TRAP SEALS. <br />16. PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES, <br />DEVICES, APPLIANCES AND APPARATUS. <br />17. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED. <br />18. MOUNT HOSE BIBBS 24" ABOVE FINISHED GRADE, UNLESS OTHERWISE NOTED. <br />19. PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. INSTALL <br />CLEANOUT WITH COVER FLUSH TO FINISH SURFACE. <br />20. COORDINATE EXACT FLOOR DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS. SET <br />FLOOR DRAINS BELOW FINISHED FLOOR TO ALLOW FOR FLOOR SLOPING TO THE DRAIN. <br />21. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, <br />ETC.) PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL <br />PANELS UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER PANELS SHALL BE RE- <br />ROUTED AT NO ADDITIONAL COST. <br />22. ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIER <br />DESIGNED TO WITHSTAND A VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF THE <br />FIXTURE. <br />23. PROVIDE SANITARY WASTE, VENT, DOMESTIC WATER, ETC. ROUGH -IN AND MAKE FINAL <br />CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES, <br />TRAPS, ETC. AND MAKE READY FOR USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY <br />THIS CONTRACTOR OR FURNISHED BY OTHERS. <br />24. PROVIDE CERTIFIED COPY OF MEDICAL GAS TEST REPORT AT FINAL A.H.C.A. <br />INSPECTION. <br />PLUMBING DRAWING INDEX <br />P001 <br />GENERAL INFORMATION - PLUMBING <br />Yes <br />PD101 <br />LEVEL 1 DEMOLITION PLAN - PHASE 1 - GRAVITY <br />Yes <br />PD102 <br />LEVEL 1 DEMOLITION PLAN - PHASE 2 - GRAVITY <br />Yes <br />PD201 <br />LEVEL 1 DEMOLITION PLAN - PHASE 1 - PRESSURE <br />Yes <br />PD202 <br />LEVEL 1 DEMOLITION PLAN - PHASE 2 - PRESSURE <br />Yes <br />P101 <br />LEVEL 1 RENOVATION PLAN - PHASE 1 - GRAVITY <br />Yes <br />P102 <br />LEVEL 1 RENOVATION PLAN - PHASE 2 - GRAVITY <br />Yes <br />P201 <br />LEVEL 1 RENOVATION PLAN - PHASE 1 - PRESSURE <br />Yes <br />P202 <br />LEVEL 1 RENOVATION PLAN - PHASE 2 - PRESSURE <br />Yes <br />P301 <br />PLUMBING DETAILS <br />Yes <br />P401 <br />PLUMBING RISER DIAGRAM <br />Yes <br />P402 <br />PLUMBING RISER DIAGRAM <br />Yes <br />1715 N. Westshore Blvd., Suite 600 <br />Tampa„ Florida 33607-3999 <br />904-256-2500 Fax 904-256-2503 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * GB238 <br />&:-T LC <br />ENGINEERING <br />S0LUT10NSo <br />255 S. Orange Avenue <br />Suite 1600 <br />Orlando, FL 32801 <br />P 407, 841.9050 <br />www.tic-engineers.com <br />COA 15 <br />0 Copyright 2019 TLC Engineering Solutions, Inc. <br />TLC Project No.: 119333 <br />THINK. LISTEN. CREATE. <br />PROJECT TITLE: <br />KITCHEN RENOVATION <br />ADVENTHEALTH ZEPHYRHILLS <br />PROJECT ADDRESS: <br />7050 Gall Blvd. Zephyrhills, FL 33541 <br />Aaron Lee Johnson, P.E. <br />Florida License #71576 <br />�E E J <br />♦♦♦,t ,pti <br />♦ <br />���♦ Q`� •' � G•E N 3 • • S ��i� <br />• •. 2 <br />No 71576 <br />•.* <br />*, * <br />M <br />.�: y • <br />Ts d.MeIt has Doen S M"A Hi I 9' d <br />y <br />Wned and seated by the ws*Adua, iy `� <br />named. dated DgWl <br />���r�p',' <br />O <br />4= <br />usrg a ,mil ,� <br />S+pnature Pooled udDws of Ihes efiTCl� 1`C ♦♦ <br />doc~ are not t�deted steed <br />40 <br />and sea4d. and the epnature mwt De�}p <br />verified «, an~ e+ect.a,K copies �- 1 t �� 0.03.25 <br />��1:29' 21-04'00' <br />M <br />N <br />W <br />0 <br />O <br />U <br />I~ <br />Z <br />w <br />J <br />U <br />Q <br />U <br />Q <br />REVISIONS <br />NO. DESCRIPTION DATE <br />DATE ISSUED: 03/20/2020 <br />REVIEWED BY: ALJ <br />DRAWN BY: BJL <br />DESIGNED BY: BJL <br />PROJECT NUMBER: <br />504- 0226- 000 <br />0 2019 RS&H, INC. <br />SHEET TITLE: <br />GENERAL <br />INFORMATION - <br />PLUMBING <br />SHEET ID: <br />Pool <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />Copyright C 2018. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />2 <br />3 <br />4 <br />:1 <br />