<br />GENERAL NOTES FOR LIFE SAFETY PLANS:
<br />1. THE EXISTING -TO -REMAIN PORTIONS OF THE LIFE SAFETY PLANS WERE PROVIDED TO THE
<br />ARCHITECT BY THE PROPERTY OWNER. RS&H, INC., TAKES NO RESPONSIBILITY FOR THEIR
<br />ACCURACY.
<br />2. THE LIFE SAFETY PLANS ARE "DIAGRAMMATIC ONLY". THEIR PURPOSE IS SOLELY TO REPRESENT
<br />THE LIFE SAFETYCOMPONENTS FOR THE PROJECT (AS INCLUDED IN THECONSTRUCTION
<br />DOCUMENTS PREPARED BY THE ARCHITECT, ELECTRICAL ENGINEER, ETC.). THE GENERAL
<br />CONTRACTOR SHALL USE THE CONSTRUCTION DOCUMENTS (NOT THE LIFE SAFETY PLANS) FOR
<br />THEIMPLEMENTATION OF THE REQUIRED LIFE SAFETY COMPONENTS INTO THE PROJECT.
<br />3. THE CONTRACTOR SHALL ADVISE THE ARCHITECT IMMEDIATELY UPON DISCOVERY OF ANY LIFE
<br />SAFETY COMPONENT THAT IS SHOWN ON THE LIFE SAFETY PLANS BUT HAS NOT BEEN INCLUDED
<br />IN THE CONSTRUCTION DOCUMENTS PREPARED BY THE ARCHITECT, ELECTRICAL ENGINEER, ETC.
<br />4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING THAT THE REQUIRED
<br />VISIBILITY FOR EACH INDIVIDUALLY INSTALLED EXIT LIGHT IS NOT IN ANYWAY DIMINISHED DUE TO
<br />VISUAL INTERFERENCE CAUSED BY ANY OTHER LIGHT FIXTURE, DEVICE, SIGN, ETC. (THE
<br />CONTRACTOR SHALL COORDINATE WITH THE ARCHITECT'S REFLECTED CEILING PLANS, THE
<br />ELECTRICAL DRAWINGS, THE GRAPHICS DRAWINGS, ETC.)
<br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR STENCILING EACH "WALL/PARTITION/BARRIER"
<br />CLASSIFICATION IN RED LETTERS ABOVE THE FINISH CEILING ON EACH SIDE OF ALL FIRE WALLS,
<br />RATED FIRE BARRIERS, RATED SMOKE BARRIERS, NON -RATED SMOKE PARTITIONS, ETC.
<br />GENERAL FIRE SPRINKLER NOTES:.
<br />1. CONTRACTOR SHALL SUBMIT PLANS FOR A SEPARATE PERMIT FOR THIS WORK
<br />2. ALL WORK SHALL COMPLY WITH THE CURRENTTLY ADOPTED VERSION OF NFPA 13
<br />3. ALL WORK SHALL BE DONE BY A LICENSED CONTRACTOR EXPERIENCED WITH THIS TYPE OF
<br />WORK.
<br />4. THE EXISTING SPRINKLER SYSTEM SHALL BE REUSED WHENEVER POSSIBLE. NEW HEADS SHALL
<br />BE PROVIDED AT LOCATIONS AS REQUIRED.
<br />5. CONTRACTOR TO PROVIDE TEMPORARY FIRE PROTECTION OF BUILDING AS REQUIRED.
<br />6. PROVIDE SHOP DRAWINGS FOR ARCHITECT'S REVIEW, INCLUDING PIPING, PROPOSED
<br />LOCATIONS, AND NEW SPRINKLER HEADS, AT ALL LOCATIONS. PROVIDE SPRINKLER HEADS TO
<br />MATCH EXISTING HEADS, IF APPLICABLE.
<br />GENERAL NOTES C� DEMOLITION FOR PLANS,
<br />1. COMPLY WITH NEW CONSTRUCTION AND RCP REQUIREMENTS OF THE GENERAL NOTES IN THIS
<br />SET OF DRAWINGS WHICH ALSO APPLY TO THE DEMOLITION FLOOR PLANS.
<br />2. THE DEMOLITION DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING DRAWINGS PROVIDED TO
<br />THE ARCHITECT/ENGINEER BY THE OWNER, AND MAY NOT REFLECT ACTUAL FIELD CONDITIONS.
<br />PRIOR TO PROCEEDING WITH ANY WORK, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
<br />VERIFY THE ACCURACY OF THESE DRAWINGS IN COMPARISON TO EXISTING FIELD CONDITIONS AND
<br />THEN IMMEDIATELY NOTIFY THE ARCHITECT OF ANY INCONSISTENCIES BETWEEN THESE DRAWINGS
<br />AND ACTUAL CONDITIONS.
<br />3. IF ANY EXISTING FIREPROOFING AND/OR RATED ASSEMBLIES (WHICH ARE SUPPOSED TO REMAIN)
<br />ARE DAMAGED DURING DEMOLITION, THEY SHALL BE REPAIRED TO CONFORM TO THE ORIGINAL
<br />FIRE PROTECTION REQUIREMENTS. ALSO, THE INTEGRITY OF EXISTING RATED FLOOR, WALL,
<br />BARRIER AND ROOF ASSEMBLIES (WHICH ARE SUPPOSED TO REMAIN) SHALL BE MAINTAINED
<br />THROUGHOUT ALL PHASES OF CONSTRUCTION. (NOTE: AS APPLICABLE, CONTACT ARCHITECT TO
<br />VERIFY TESTED ASSEMBLIES TO BE USED FOR REPAIRS.)
<br />4. REMOVE EXISTING CONSTRUCTION AS INDICATED. TYPICAL WALL REMOVAL SHALL INCLUDE
<br />MECHANICAL, PLUMBING, ELECTRICAL, COMMUNICATIONS AND SECURITY SYSTEMS CONTAINED
<br />THEREIN. REMOVE DOORS, CABINET WORK, CASEWORK, WINDOWS, FRAMES, FINISHES, FIXTURES
<br />AND THEIR ATTACHMENTS AS REQUIRED. AFTER REMOVAL, REPAIR HOLES IN EXISTING -TO -REMAIN
<br />FLOORS, WALLS, BARRIERS AND ROOFS TO COMPLY WITH ORIGINAL FIRE, SMOKE AND SOUND
<br />ASSEMBLIES, FIRE PROTECTION REQUIREMENTS, AND STRUCTURAL INTEGRITY. PREPARE
<br />SURFACES TO RECEIVE NEW FINISH PER INTERIOR DESIGN DRAWINGS AND SPECIFICATIONS.
<br />(WHERE NEW FINISH IS CALLED FOR ON AN EXISTING SURFACE, REMOVE THE EXISTING FINISH AND
<br />PREPARE EXISTING SURFACE TO RECEIVE THE NEW FINISH.)
<br />5. SEE MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL AND DRAWINGS FOR DEMOLITION
<br />OF UTILITIES.
<br />6. AT ALL WALLS/PARTITIONS/BARRIERS, FLOORS AND ROOFS WHICH ENCLOSE OR TOUCH SPACES
<br />WHERE WORK IS BEING PERFORMED AS A PART OF THIS PROJECT, THE CONTRACTOR SHALL VERIFY
<br />THAT THIS EXISTING CONSTRUCTION (INCLUDING DAMPERS, DUCT PENETRATIONS, DOORS,
<br />WINDOWS, FRAMES, ETC.) MEETS THE FIRE, SMOKE AND SOUND ASSEMBLY RATINGS DESIGNATED
<br />ON THESE DRAWINGS. THE CONTRATOR SHALL ALSO MAKE ANY REPAIRS AND/OR MODIFICATIONS
<br />NECESSARY TO BRING THE EXISTING CONSTRUCTION (INCLUDING DAMPERS, DUCT PENETRATIONS,
<br />DOORS, WINDOWS, FRAMES, ETC.) UP TO THE PROPER INDICATED FIRE, SMOKE AND SOUND
<br />ASSEMBLY RATINGS. DOORS, WINDOWS AND FRAMES WHICH DO NOT MEET THE REQUIREMENTS OF
<br />THE DESIGNATED WALL/PARTITION/BARRIER ASSEMBLIES (INCLUDING PROPER LABELS) SHALL BE
<br />REPLACED. THE GENERAL CONTRACTOR SHALL DESIGNATE AN ALLOWANCE FOR THIS WORK.
<br />7. DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND ORDINANCES
<br />AS SET FORTH BY ALL AUTHORITIES HAVING JURISDICTION.
<br />8. THE CONTRACTOR SHALL BRACE ALL EXISTING STRUCTURES AND ALL STRUCTURAL ELEMENTS
<br />AS NECESSARY DURING DEMOLITION.
<br />9. THE CONTRACTOR SHALL NOT CUT EXISTING OR NEW STRUCTURAL WORK IN ANY MANNER THAT
<br />MAY RESULT IN A REDUCTION OF LOAD CARRYING CAPACITY OR LOAD/DEFLECTION RATIO. THE
<br />CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF ALL STRUCTURAL CUTS PRIOR TO
<br />EXECUTION SO THAT APPROVAL CAN BE OBTAINED IN ADVANCE FROM THE ARCHITECT.
<br />10. WHERE EXISTING CONSTRUCTION IS FOUND TO CONTAIN ANY HAZARDOUS MATERIAL, THE
<br />CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND THE ARCHITECT IN WRITING. NOTE:
<br />REMOVAL, DISPOSAL AND REPLACEMENT OF THE HAZARDOUS MATERIAL IS THE SOLE
<br />RESPONSIBILITY OF THE OWNER.
<br />11. THE CONTRACTOR SHALL REPLACE OR REPAIR ANY EXISTING -TO -REMAIN MATERIALS AND
<br />FINISHES (CEILING GRID, CEILING TILE, GYPSUM BOARD, FINISHES, DOORS, WINDOWS, FRAMES,
<br />WALL PROTECTION, ETC.) WHICH ARE DAMAGED DURING DEMOLITION OR CONSTRUCTION.
<br />12.THE CONTRACTOR SHALL COORDINATE ALL ICRA REQUIREMENTS WITH THE OWNER.
<br />13.ALL WORK TO BE COMPLETED OUTSIDE THE AREA OF CONSTRUCTION SHALL BE ISOLATED TO
<br />PORTABLE "DUST -BUGGIES" OR WORK BOOTHS.
<br />14.SEAL ALL EXISTING AND ABANDONED PIPE OR CONDUIT PENETRATIONS IN ACCORDANCE WITH
<br />THE APPROPRIATE U.L. DESIGN.
<br />15.BUNDLE TIE AND INDEPENDENTLY SUPPORT ALL NEW AND EXISTING LOW VOLTAGE CABLING
<br />ABOVE THE CEILING.
<br />16.REMOVE ALL EXISTING ABANDONED CEILING MOUNTED HANGER WIRES, SUPPORT BRACKETS,
<br />HANGER RODS, AND MOUNTING STRAPS.
<br />17.IN ACCORDANCE WITH NFPA 51B AND NFPA 601, THE CONTRACTOR SHALL OBTAIN A HOT WORK
<br />PERMIT PRIOR TO BEGINNING ANY WELDING, CUTTING, BRAZING, GRINDING OR OTHER ACTIVITIES
<br />THAT GENERATES SPARK CAPABLE OF CAUSING COMBUSTION.
<br />18.AS REQUIRED BY NFPA, REMOVE ALL FLAMMABLE ITEMS, INCLUDING BUT LIMITED TO
<br />COMPRESSED AIR AND GAS CANS OR CYLINDERS (I.E. BRAZING, ACETYLENE, PROPANE TANKS,
<br />PAINT CANS, LUBRICANTS, ETC.) FROM THE JOB SITE WHEN THE PROJECT HAS BEEN VACATED BY
<br />CONSTRUCTION PERSONNEL AND DURING THE TIME THE FIRE ALARM SYSTEM AND FIRE
<br />SUPPRESSION SYSTEM IS INACTIVE.
<br />19. ALL MODIFICATIONS TO THE FIRE ALARM OR FIRE SPRINKLER SYSTEM, INCLUDING AUDIOVISUAL
<br />COMMUNICATION DEVICES, SHALL BE DEFERRED TO THE CITY UNDER SEPARATE SUBMITTAL.
<br />20. REMOVE PORTION OF EXISTING SLAB AS REQUIRED TO INSTALL NEW PLUMBING. COORDINATE
<br />WITH PLUMBING DRAWINGS.
<br />i
<br />GENERAL NOTES FOR NEW CONSTRUCTION
<br />AND DIMENSION PLANS.
<br />1. COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING NOTES IN THIS SET OF DRAWINGS WHICH
<br />ALSO APPLY TO THE NEW CONSTRUCTION AND DIMENSION FLOOR PLANS:
<br />A. "GENERAL NOTES" ON THIS SHEET
<br />B. "GENERAL NOTES FOR DEMOLITION PLANS" ON THIS SHEET
<br />C. "GENERAL NOTES FOR REFLECTED CEILING PLANS" ON THIS SHEET
<br />2. EXISTING -TO -REMAIN PARTITIONS/BARRIERS, DOORS, WINDOWS, PLUMBING FIXTURES,
<br />CABINETWORK/CASEWORK, EQUIPMENT, ETC., ARE "SCREENED -BACK" AND ON NEW CONSTRUCTION
<br />AND DIMENSION PLANS ARE INDICATED BY SOLID LINES. REFER TO DEMOLITION FLOOR PLANS FOR
<br />EXTENT OF "EXISTING -TO -BE -REMOVED".
<br />3. ITEMS DENOTED ON THE NEW CONSTRUCTION FLOOR PLANS WITH A DASHED LINE OR DOTTED LINES
<br />ARE BEING FURNISHED BY THE OWNER OR INDICATE ITEMS OVERHEAD. (COMPLY WITH THE
<br />REQUIREMENTS OF "GENERAL NOTES" ON NOTES AND ABBREVIATIONS SHEET)
<br />4. SEE REFLECTED CEILING PLANS FOR LOCATIONS OF GYPSUM BOARD FURR DOWNS AND SOFFITS.
<br />5. REFER TO THE A-500 SERIES FOR DETAILS WHICH APPLY TO THE FLOOR PLANS.
<br />6. SEE INTERIOR DESIGN DRAWINGS FOR INTERIOR FINISHES AND FOR LOCATIONS OF ACCENT WALLS
<br />AND WALL PROTECTION.
<br />7. PROVIDE 5/8 INCH TYPE "X" GLASS MAT PAPERLESS INTERIOR GYPSUM BOARD AT WET LOCATIONS.
<br />8. WHERE DEMOLITION OF CERTAIN ITEMS RESULTS IN UNPROTECTED OPENINGS OR PENETRATIONS IN
<br />EXISTING -TO -REMAIN FLOORS, WALLS, CEILING, ROOFS, ETC., REPAIR SUCH OPENINGS AND
<br />PENETRATIONS AS REQUIRED TO MEET ORIGINAL FIRE PROTECTION, SOUND AND STRUCTURAL
<br />REQUIREMENTS.
<br />9. FOR ADDITIONAL DIMENSIONING, COMPLY WITH REQUIREMENTS ON ENLARGED PLANS, WALL
<br />SECTIONS, INTERIOR ELEVATIONS, PLAN DETAILS AND SECTION DETAILS.
<br />10. THE CONTRACTOR SHALL NOT SCALE THE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE
<br />CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT IN
<br />WRITING PRIOR TO CONTINUING WITH CONSTRUCTION.
<br />11. DIMENSIONS SHOWN ON THE FLOOR PLANS ARE: TO FACE OF STUD AT METAL STUD
<br />PARTITIONS/BARRIERS OR TO OUTSIDE FACE OF EXISTING WALLS. EXTREMELY CRITICAL MINIMUM
<br />DIMENSIONS MAY BE INDICATED AS "MINIMUM", "CLEAR", OR "MINIMUM CLEAR".
<br />12. CRITICAL NOTE: THE CONTRACTOR SHALL TAKE INTO ACCOUNT THE THICKNESSES OF THE
<br />SCHEDULED FINISH MATERIALS PRIOR TO "LAYING OUT" METAL STUD PARTITIONS/BARRIERS, SINCE THE
<br />TOTAL "OUT -TO -OUT" WALL THICKNESS MUST BE CONSIDERED SO THAT THE REQUIRED "MINIMUM
<br />FACE -OF -FINISH" AND "MINIMUM CLEAR FACE -OF -FINISH" DIMENSIONS CAN BE MAINTAINED AFTER THE
<br />INSTALLATION OF THE FINISH MATERIALS.
<br />13. INTERIOR METAL STUD PARTITIONS/BARRIERS SHALL BE CONSTRUCTED OF 3 5/8" (MINIMUM) METAL
<br />STUDS (OR AS SHOWN BELOW) UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL ALSO COMPLY
<br />WITH U.L. DESIGN NO. U444 OR U458 AT RATED PLUMBING WALLS/BARRIERS.
<br />14. WHERE NEW GYPSUM BOARD PARTITIONS/BARRIERS ARE A CONTINUATION OF AN EXISTING WALL
<br />OR COLUMN ENCASEMENT, THE FACE OF NEW GYPSUM BOARD SHALL BE ALIGNED WITH FACE OF
<br />EXISTING SURFACE. WHERE A ONE -HOUR RATED BARRIER OR A NON -RATED PARTITION IS SHOWN AS A
<br />CONTINUATION OF A TWO-HOUR RATED BARRIER OR COLUMN ENCASEMENT, THE OUTSIDE FACE OF
<br />THE GYPSUM BOARD SHALL BE ALIGNED. STUDS SHALL BE OFFSET AND/OR ADDITIONAL LAYERS OF
<br />GYPSUM BOARD SHALL BE PROVIDED (AS REQUIRED TO PROVIDE FACE ALIGNMENT OF GYPSUM
<br />BOARD) WHILE MAINTAINING THE REQUIRED RATED INTEGRITY.
<br />15. TYPICAL PARTITION TYPE IS "A" UNLESS OTHERWISE NOTED.
<br />16. PATCH ANY EXISTING TO REMAIN WALLS AND RESKIM/REFINISH WALL SURFACE. REPAINT ANY
<br />EXISTING TO REMAIN WALLS, HOLLOW METAL DOOR FRAMES AND TRIM.
<br />GENERAL NOTES FOR REFLECTED CEILING PLANS:
<br />1. COMPLY WITH THE FOLLOWING NOTES IN THIS SET OF DRAWINGS WHICH ALSO APPLY TO THE
<br />REFLECTED CEILING PLANS:
<br />A. "GENERAL NOTES" ON THIS SHEET
<br />B. "GENERAL NOTES FOR DEMOLITION PLANS" ON THIS SHEET
<br />C. "GENERAL NOTES FOR NEW CONSTRUCTION AND DIMENSION PLANS" ON THIS SHEET
<br />2. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE REFLECTED CEILING PLANS
<br />WITH: ELECTRICAL'S LIGHTING, SYSTEMS AND COMMUNICATIONS DRAWINGS; MECHANICAL'S
<br />SUPPLY, RETURN AND EXHAUST DRAWINGS; AND FIRE PROTECTION'S DRAWINGS IF APPLICABLE.
<br />THE CONTRACTOR SHALL THEN IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY
<br />ERROR, INCONSISTENCY OR OMISSION THAT IS DISCOVERED.
<br />3. SEE ELECTRICAL, COMMUNICATION, SECURITY AND FIRE PROTECTION DRAWINGS FOR
<br />LOCATIONS OF CEILING MOUNTED SMOKE DETECTORS, COMMUNICATION DEVICES, FIRE ALARM
<br />DEVICES, SECURITY DEVICES, ETC.
<br />4. ONLY CEILING MOUNTED EXIT LIGHTS ARE SHOWN ON THE REFLECTED CEILING PLANS. SEE
<br />THE ELECTRICAL DRAWINGS FOR LOCATIONS OF WALL MOUNTED EXIT LIGHTS. (NOTE: THE
<br />BOTTOM OF EXIT LIGHTS SHALL BE A MINIMUM OF T-0" CLEAR AFF.)
<br />5. SPRINKLER HEADS:
<br />A. THE SPRINKLER HEADS ARE NOT SHOWN ON THE REFLECTED CEILING PLANS. REFER
<br />TO FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION.
<br />B. THE CONTRACTOR SHALL RELOCATE AND/OR INSTALL SUFFICIENT HEADS IN ALL
<br />SPACES TO PROVIDE COMPLETE (100%) AUTOMATIC SPRINKLER COVERAGE AS DEFINED
<br />IN NFPA STANDARD 13, - FIRE SUPPRESSION AND AS SHOWN ON THE FIRE PROTECTION
<br />DRAWINGS.
<br />C. NEITHER SPRINKLER HEADS OR CONCEALED SPRINKLER HEAD COVERS ARE ALLOWED
<br />TO BE PAINTED. THE CONTRACTOR SHALL VERIFY THAT ANY SPRINKLER HEADS THAT ARE
<br />ACCIDENTALLY PAINTED ARE REMOVED FROM THE SITE AND REPLACED WITH NEW ONES.
<br />6. THE CONTRACTOR SHALL ADVISE THE OWNER AND TENANTS THAT AN 18 INCH MINIMUM
<br />VERTICAL CLEARANCE SHALL BE MAINTAINED BETWEEN THE BOTTOM OF THE EXTENDED (DROP
<br />DOWN) SPRINKLER HEADS AND THE TOP OF ANY FILES, SHELVING, EQUIPMENT, LOCKERS, ETC.,
<br />(WHETHER CONTRACTOR OR OWNERFURNISHED). THE CONTRACTOR SHALL ALSO ADVISE THE
<br />OWNER AND TENANTS THAT ITEMS SHALL NOT BE PLACED OR STORED ON TOP OF SHELVING SO
<br />THAT THIS CODE REQUIRED 18 INCH MINIMUM VERTICAL CLEARANCE WILL BE MAINTAINED.
<br />7. PROVIDE GYPSUM BOARD FURR-DOWNS OVER ALL WALL CABINETS. SEE A-500 SERIES FOR
<br />DETAILS.
<br />8. WHERE EXISTING LAY -IN CEILING GRIDS ARE REMOVED AND RE -INSTALLED, THE CONTRACTOR
<br />SHALL TAKE CARE NOT TO DAMAGE THE GRID. ANY DAMAGED GRID SHALL BE REPLACED WITH
<br />NEW MATERIAL. THESE NEW MATERIALS SHALL MATCH THE EXISTING IN A UNIFORM MANNER
<br />FOR COLOR, TEXTURE, PATTERN, ETC. IF UNIFORMITY CANNOT BE ACHIEVED, THE CONTRACTOR
<br />SHALL REPLACE THE ENTIRE CEILING WITHIN THAT SPACE WITH NEW MATERIAL. THE
<br />CONTRACTOR SHALL PROVIDE NEW MATERIAL AS APPROVED BY BOTH OWNER AND ARCHITECT
<br />IN WRITING.
<br />9. THE "LIMITS OF CONSTRUCTION" LINES SHOWN ON THE ARCHITECT'S REFLECTED CEILING
<br />PLANS APPLY ONLY TO THE LIMITS OF THE ARCHITECTURAL NEW CONSTRUCTION AND
<br />RENOVATION. SEE THE OTHER DISCIPLINES' DRAWINGS FOR THE LIMITS OF THE NEW
<br />CONSTRUCTION AND RENOVATION FOR THEIR DISCIPLINE.
<br />10, SEE THE INTERIOR DESIGN DRAWINGS FOR THE PAINT SPECIFICATIONS AND COLORS OF
<br />PAINTED CEILINGS AND INTERIOR SOFFITS. HORIZONTAL SURFACES OF SOFFITS SHALL BE
<br />PAINTED THE SAME COLOR AS THE VERTICAL SURFACES, UNLESS NOTED OTHERWISE.
<br />11. RECESSED CAN LIGHT FIXTURES:
<br />A. THE RECESSED CAN LIGHT FIXTURES SHALL BE CENTERED IN GYPSUM BOARD
<br />SOFFITS, U.N.O
<br />B. THE RECESSED CAN LIGHT FIXTURES SHALL BE CENTERED IN THE CEILING TILE, U.N.O.
<br />C. RECESSED CAN LIGHT FIXTURES IN A SERIES SHALL BE ALIGNED AND EQUALLY
<br />SPACED, U.N.O.
<br />GENERAL PROJE
<br />CT CT NOTES. E
<br />1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES, STANDARDS AND GOVERNING
<br />AUTHORITIES.
<br />2. THESE DRAWINGS ARE ISSUED IN CONJUNCTION WITH THE PROJECT MANUAL OF THE SAME DATE,
<br />TITLE AND PROJECT NUMBER AND TOGETHER ARE REFERRED TO AS "CONTRACT DOCUMENTS."
<br />3. REFER TO ARCHITECTURAL, INTERIOR DESIGN, MECHANICAL, PLUMBING, FIRE PROTECTION AND
<br />ELECTRICAL DRAWINGS FOR COORDINATION OF WORK.
<br />4. NOTES APPEAR ON A NUMBER OF DRAWINGS FOR DIFFERENT SYSTEMS AND MATERIALS.
<br />REFERENCE ALL ISSUED CONTRACT DOCUMENTS TO APPLY APPLICABLE NOTES, SYMBOLS AND
<br />ABBREVIATIONS TO BUILDING COMPONENTS.
<br />5. DO NOT SCALE THE DRAWINGS.
<br />6. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME KNOWLEDGEABLE OF CONDITIONS. THE
<br />CONTRACTOR SHALL INVESTIGATE, VERIFY AND BE RESPONSIBLE FOR ALL THE REQUIREMENTS OF
<br />THE PROJECT AND SHALL NOTIFY THE OWNER AND ARCHITECT OF ANY EXISTING CONDITIONS
<br />REQUIRING INFORMATION BEFORE PROCEEDING WITH ANY WORK.
<br />7. THE CONTRACTOR SHALL PROTECT ALL EXISTING SITE ELEMENTS FROM DAMAGE DUE TO
<br />ALTERATION AND CONSTRUCTION OPERATIONS AND THEY SHALL REPAIR OR REPLACE ELEMENTS
<br />DAMAGED DURING THE PROJECT.
<br />8. ANY UTILITY SHUT -OFFS AS REQUIRED BY THE CONTRACTOR FOR COMPLETION OF THE WORK
<br />SUCH AS ELECTRICAL, GAS, WATER, SEWER, STEAM, ETC., MUST BE SCHEDULED WITH THE OWNER,
<br />ARCHITECT AND UTILITY COMPANY PRIOR TO COMMENCING WORK.
<br />9. DETAILS SHOWN ARE INTENDED TO BE INDICATIVE OF THE PROFILES AND TYPE OF DETAILING
<br />REQUIRED FOR THE WORK. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN.
<br />10. UNLESS NOTED OTHERWISE, ALL FASTENERS AND FASTENING DEVICES ARE TO BE CONCEALED IN
<br />ALL FINISHED SPACES.
<br />11. ANY PIPING, DUCTS, CONDUITS, ETC. THAT PENETRATE FIRE RATED FLOOR SLABS AND WALLS
<br />SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE FIRE INTEGRITY OF THE FLOOR OR
<br />WALL. FIRE STOP RATINGS SHALL MATCH RATINGS OF FLOORS OR WALLS WHERE PENETRATIONS
<br />OCCUR. PROVIDE FIRE DAMPERS IN DUCTS PENETRATING FIRE -RATED WALLS AND FLOORS TO MEET
<br />THE APPLICABLE BUILDING CODES.
<br />12. ALL JOINTS OF ANY ELEMENT OF CONSTRUCTION WHICH ARE REQUIRED TO HAVE A FIRE
<br />RESISTANCE RATING SHALL BE INSTALLED PER THE MANUFACTURER'S PUBLISHED TESTED
<br />ASSEMBLIES, SHALL BE TIGHT AND SHALL PREVENT THE PASSAGE OF SMOKE AND FLAME.
<br />13. WHERE THE FIRE RATINGS OF WALLS ARE NOTED ON THE DRAWINGS, THE FIRE RATING SHALL
<br />APPLY TO THE ENTIRE PERIMETER ENCLOSURE OF THE ROOM OR SPACE FOR THE FULL LENGTH AND
<br />HEIGHT OF AREAS BEING SEPARATED, EXTENDING TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK.
<br />14. PROVIDE FIRE STOPS TO SEPARATE WALL CAVITIES FROM HORIZONTAL PLENUM AREAS AND
<br />BETWEEN FLOORS TO CLOSE OPENINGS. FIRE RATING OF STOPS SHALL MATCH THE FIRE RATING OF
<br />VERTICAL SEPARATION OR FLOOR CONSTRUCTION, WHICHEVER IS GREATER.
<br />15. CONSTRUCTION AROUND CABINETS, PANELS AND BOXES RECESSED IN FIRE -RATED FLOOR, WALL
<br />AND CEILING ASSEMBLIES SHALL MAINTAIN THE FIRE -RATING NOTED IN THE DRAWINGS.
<br />16. OPENINGS IN WALL, CEILING, FLOOR AND ROOF ASSEMBLIES SHALL BE SEALED WITH
<br />PENETRATION SEALANT SYSTEMS THAT MEET OR EXCEED THE REQUIRED FIRE RATINGS.
<br />17. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER BY GASKETS OR
<br />COATINGS OR BOTH TO AVOID GALVANIC CORROSION ACTION.
<br />18. PATCH FIREPROOFING TO MATCH EXISTING.
<br />19. SEE MECHANICAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL DRAWINGS TO DETERMINE
<br />QUANTITIES OF DIFFUSERS, GRILLES, LIGHT FIXTURES, SPRINKLER HEADS, ETC.
<br />20. PIPE AND COLUMN FURRING SHALL BE HELD AS CLOSE TO THE PIPING AND/OR COLUMNS AS
<br />POSSIBLE, UNLESS NOTED OTHERWISE.
<br />21. THE EXTENT OF THE WORK SHOWN ON THE PLANS AND DETAILS REFLECTS THE BEST JUDGMENT
<br />OF THE ARCHITECT/ENGINEER. THE CONTRACTOR SHALL FAMILIARIZE HIM/HERSELF WITH THE
<br />EXISTING CONDITIONS AND ADVISE THE ARCHITECT, IN WRITING, OF ANY SITUATION THAT WOULD NOT
<br />ALLOW HIM/HER TO PROCEED ON THE BASIS OF THESE DOCUMENTS.
<br />22. THE ARCHITECT/ENGINEER'S SELECTION OF MATERIALS AND DETAILS DOES NOT RELIEVE THE
<br />CONTRACTOR FROM VERIFYING WITH THE MATERIAL SUPPLIERS THAT THE PROPOSED MATERIALS
<br />ARE CORRECT AND PROPER FOR THE INTENDED APPLICATION AND USE.
<br />23. CONCRETE FILLS ABOVE STRUCTURAL SLABS SHALL BE REINFORCED. REFER TO STRUCTURAL
<br />DRAWINGS FOR ADDITIONAL REQUIREMENTS.
<br />24. UNLESS NOTED OTHERWISE, WHERE AN ARCHITECTURAL FINISHED FLOOR IS TO BE PROVIDED
<br />(REQUIRING A DEPRESSED STRUCTURAL SLAB), THE FLOOR ELEVATIONS ARE TO TOP OF FINISHED
<br />FLOOR. WHERE AN ARCHITECTURAL FINISHED FLOOR IS INTENDED FOR SURFACE APPLICATION, THE
<br />FLOOR ELEVATIONS ARE TO TOP OF STRUCTURAL SLAB. REFER TO STRUCTURAL DRAWINGS FOR
<br />LOCATION OF DEPRESSED SLABS.
<br />25. UNLESS NOTED OTHERWISE, CONCRETE PAD WITH REINFORCING SHALL BE INSTALLED UNDER ALL
<br />FLOOR MOUNTED MECHANICAL AND ELECTRICAL EQUIPMENT. REFER TO MECHANICAL, ELECTRICAL,
<br />PLUMBING AND FIRE PROTECTION DRAWINGS FOR THE EXTENT OF EQUIPMENT PADS. THE
<br />CONTRACTOR SHALL COORDINATE THE SIZE, THICKNESS AND LOCATION OF THE CONCRETE PADS
<br />WITH THE EQUIPMENT INSTALLER.
<br />26. AT THOSE PLACES WHERE MATERIALS ARE APPLIED TO, OR ARE IN DIRECT CONTACT WITH WORK
<br />INSTALLED BY ANOTHER SUBCONTRACTOR, COMMENCEMENT OF WORK IMPLIES THE ACCEPTANCE OF
<br />THE SUBSTRATE AND EXISTING CONDITIONS AS SUITABLE FOR THE APPLICATION INTENDED.
<br />27. ALL WORK SHALL BE EXECUTED IN A WORKMANLIKE MANNER. CONSTRUCTION OF NEW
<br />HORIZONTAL SURFACES SHALL BE LEVEL AND FLAT AND NEW VERTICAL SURFACES SHALL BE
<br />CONSTRUCTED TO BE PLUMB, UNLESS NOTED OTHERWISE.
<br />28. WHERE NOT INDICATED, PROVIDE BLOCKING IN WALLS, SOFFITS, AND CEILINGS RECEIVING
<br />SIGNAGE, COAT HOOKS, LOCKERS, MARKER BOARDS, AND OTHER MOUNTED ITEMS, ACCORDING TO
<br />THE MANUFACTURER'S RECOMMENDATIONS.
<br />29, CONTINUOUS PERIMETER FIRE SAFING BETWEEN FLOORS SHALL BE PROVIDED AND
<br />COORDINATED WITH THE EXTERIOR WALL SYSTEMS AND ASSEMBLIES. THE FIRE SAFING'S RATING
<br />SHALL MATCH OR EXCEED THAT OF THE FLOOR CONSTRUCTION RATING.
<br />30. CONTINUOUS PERIMETER FIRE SAFING BETWEEN FLOORS SHALL BE PROVIDED AND
<br />COORDINATED WITH THE EXTERIOR WALL SYSTEMS AND ASSEMBLIES. THE FIRE SAFING'S RATING
<br />SHALL MATCH OR EXCEED THAT OF THE FLOOR CONSTRUCTION RATING.
<br />31. CONTRACTOR TO CONFIRM AND FIELD VERIFY DIMENSIONS TO COORDINATE WITH OWNER
<br />PROVIDED EQUIPMENT AND FURNISHINGS.
<br />32. SUBSTITUTIONS OF MATERIALS MAY OCCUR IN ACCORDANCE WITH THE CONTRACT DOCUMENTS,
<br />AND ONLY IF AUTHORIZED BY THE ARCHITECT.
<br />33. CONTRACTOR SHALL PERFORM FIELD VERIFICATION OF ALL THE EXISTING CONDITIONS ON THE
<br />SITE AND SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES AND SHALL COMPARE THE
<br />INFORMATION TO THE CONTRACT DOCUMENTS PRIOR TO THE COMMENCEMENT OF ALL WORK. THE
<br />CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES.
<br />34. ALL CONTRACTOR PROVIDED MATERIALS SHALL BE NEW AND DELIVERED AND INSTALLED IN GOOD
<br />CONDITION AND WITHOUT ANY DEFECTS.
<br />35. ANY WORK NOT CONFORMING TO THESE SPECIFICATIONS WILL BE REJECTED. THE ARCHITECT OR
<br />THE OWNER MAY REJECT THE WORK AND REJECTED WORK WILL BE REMOVED AND REPLACED AT NO
<br />ADDITIONAL COST TO THE OWNER.
<br />36. CONTRACT DOCUMENTS ARE INCLUSIVE OF ALL DISCIPLINES DRAWINGS AND SPECIFICATIONS.
<br />THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION ACROSS ALL DRAWINGS.
<br />RS&H
<br />1715 N. Westshore Blvd., Suite 600
<br />Tampa„ Florida 33607-3999
<br />904-256-2500 Fax 904-256-2503
<br />www.rsandh.com
<br />FL Cert. Nos. AAC001886 * IB26000956
<br />5620 * LCC000210 * G6238
<br />Advent Health
<br />PROJECT TITLE:
<br />KITCHEN RENOVATION
<br />ADVENTHEALTH ZEPHYRHILLS
<br />PROJECT ADDRESS:
<br />7050 Gall Blvd. Zephyrhills, FL 33541
<br />SEAL
<br />boo-JIN KjM
<br />AR95652
<br />Nftlly v9-d by Y-4m Kim
<br />DN: D=US,
<br />E=yoalln.kim*rsandh com,
<br />Yoo-Jin Kim D=RBN.CN=Yoo-JmKim
<br />D. 2020 04.09
<br />09:30.42-0400'
<br />SIGNATURE
<br />REVISIONS
<br />NO. DESCRIPTION DATE
<br />DATE ISSUED: 03/20/2020
<br />REVIEWED BY: YK
<br />DRAWN BY: YK/KN
<br />DESIGNED BY: JS
<br />PROJECT NUMBER:
<br />504- 0226- 000
<br />0 2019 RS&H, INC.
<br />SHEET TITLE:
<br />GENERAL NOTES
<br />SHEET ID:
<br />G002
<br />PROJECT STATUS:
<br />CONSTRUCTION
<br />DOCUMENTS