I I. 1 1 1. I I -.- - 1 1 1 1111 1, LI P i!yp "I"'" I <br />1 1 2 1 3 <br />4 <br />_-I _ I I lip '-I l <br />5 <br />I$] <br />C <br />0 <br />A <br />a <br />Cl) <br />O <br />W <br />N <br />L0 <br />0 <br />N <br />0 <br />N <br />a0 <br />N <br />M <br />GENERAL NOTES FOR LIFE SAFETY PLANS: <br />1. THE EXISTING -TO -REMAIN PORTIONS OF THE LIFE SAFETY PLANS WERE PROVIDED TO THE <br />ARCHITECT BY THE PROPERTY OWNER. RS&H, INC., TAKES NO RESPONSIBILITY FOR THEIR <br />ACCURACY. <br />2. THE LIFE SAFETY PLANS ARE "DIAGRAMMATIC ONLY". THEIR PURPOSE IS SOLELY TO REPRESENT <br />THE LIFE SAFETYCOMPONENTS FOR THE PROJECT (AS INCLUDED IN THECONSTRUCTION <br />DOCUMENTS PREPARED BY THE ARCHITECT, ELECTRICAL ENGINEER, ETC.). THE GENERAL <br />CONTRACTOR SHALL USE THE CONSTRUCTION DOCUMENTS (NOT THE LIFE SAFETY PLANS) FOR <br />THEIMPLEMENTATION OF THE REQUIRED LIFE SAFETY COMPONENTS INTO THE PROJECT. <br />3. THE CONTRACTOR SHALL ADVISE THE ARCHITECT IMMEDIATELY UPON DISCOVERY OF ANY LIFE <br />SAFETY COMPONENT THAT IS SHOWN ON THE LIFE SAFETY PLANS BUT HAS NOT BEEN INCLUDED <br />IN THE CONSTRUCTION DOCUMENTS PREPARED BY THE ARCHITECT, ELECTRICAL ENGINEER, ETC. <br />4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING THAT THE REQUIRED <br />VISIBILITY FOR EACH INDIVIDUALLY INSTALLED EXIT LIGHT IS NOT IN ANYWAY DIMINISHED DUE TO <br />VISUAL INTERFERENCE CAUSED BY ANY OTHER LIGHT FIXTURE, DEVICE, SIGN, ETC. (THE <br />CONTRACTOR SHALL COORDINATE WITH THE ARCHITECT'S REFLECTED CEILING PLANS, THE <br />ELECTRICAL DRAWINGS, THE GRAPHICS DRAWINGS, ETC.) <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR STENCILING EACH "WALL/PARTITION/BARRIER" <br />CLASSIFICATION IN RED LETTERS ABOVE THE FINISH CEILING ON EACH SIDE OF ALL FIRE WALLS, <br />RATED FIRE BARRIERS, RATED SMOKE BARRIERS, NON -RATED SMOKE PARTITIONS, ETC. <br />GENERAL FIRE SPRINKLER NOTES:. <br />1. CONTRACTOR SHALL SUBMIT PLANS FOR A SEPARATE PERMIT FOR THIS WORK <br />2. ALL WORK SHALL COMPLY WITH THE CURRENTTLY ADOPTED VERSION OF NFPA 13 <br />3. ALL WORK SHALL BE DONE BY A LICENSED CONTRACTOR EXPERIENCED WITH THIS TYPE OF <br />WORK. <br />4. THE EXISTING SPRINKLER SYSTEM SHALL BE REUSED WHENEVER POSSIBLE. NEW HEADS SHALL <br />BE PROVIDED AT LOCATIONS AS REQUIRED. <br />5. CONTRACTOR TO PROVIDE TEMPORARY FIRE PROTECTION OF BUILDING AS REQUIRED. <br />6. PROVIDE SHOP DRAWINGS FOR ARCHITECT'S REVIEW, INCLUDING PIPING, PROPOSED <br />LOCATIONS, AND NEW SPRINKLER HEADS, AT ALL LOCATIONS. PROVIDE SPRINKLER HEADS TO <br />MATCH EXISTING HEADS, IF APPLICABLE. <br />GENERAL NOTES C� DEMOLITION FOR PLANS, <br />1. COMPLY WITH NEW CONSTRUCTION AND RCP REQUIREMENTS OF THE GENERAL NOTES IN THIS <br />SET OF DRAWINGS WHICH ALSO APPLY TO THE DEMOLITION FLOOR PLANS. <br />2. THE DEMOLITION DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING DRAWINGS PROVIDED TO <br />THE ARCHITECT/ENGINEER BY THE OWNER, AND MAY NOT REFLECT ACTUAL FIELD CONDITIONS. <br />PRIOR TO PROCEEDING WITH ANY WORK, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO <br />VERIFY THE ACCURACY OF THESE DRAWINGS IN COMPARISON TO EXISTING FIELD CONDITIONS AND <br />THEN IMMEDIATELY NOTIFY THE ARCHITECT OF ANY INCONSISTENCIES BETWEEN THESE DRAWINGS <br />AND ACTUAL CONDITIONS. <br />3. IF ANY EXISTING FIREPROOFING AND/OR RATED ASSEMBLIES (WHICH ARE SUPPOSED TO REMAIN) <br />ARE DAMAGED DURING DEMOLITION, THEY SHALL BE REPAIRED TO CONFORM TO THE ORIGINAL <br />FIRE PROTECTION REQUIREMENTS. ALSO, THE INTEGRITY OF EXISTING RATED FLOOR, WALL, <br />BARRIER AND ROOF ASSEMBLIES (WHICH ARE SUPPOSED TO REMAIN) SHALL BE MAINTAINED <br />THROUGHOUT ALL PHASES OF CONSTRUCTION. (NOTE: AS APPLICABLE, CONTACT ARCHITECT TO <br />VERIFY TESTED ASSEMBLIES TO BE USED FOR REPAIRS.) <br />4. REMOVE EXISTING CONSTRUCTION AS INDICATED. TYPICAL WALL REMOVAL SHALL INCLUDE <br />MECHANICAL, PLUMBING, ELECTRICAL, COMMUNICATIONS AND SECURITY SYSTEMS CONTAINED <br />THEREIN. REMOVE DOORS, CABINET WORK, CASEWORK, WINDOWS, FRAMES, FINISHES, FIXTURES <br />AND THEIR ATTACHMENTS AS REQUIRED. AFTER REMOVAL, REPAIR HOLES IN EXISTING -TO -REMAIN <br />FLOORS, WALLS, BARRIERS AND ROOFS TO COMPLY WITH ORIGINAL FIRE, SMOKE AND SOUND <br />ASSEMBLIES, FIRE PROTECTION REQUIREMENTS, AND STRUCTURAL INTEGRITY. PREPARE <br />SURFACES TO RECEIVE NEW FINISH PER INTERIOR DESIGN DRAWINGS AND SPECIFICATIONS. <br />(WHERE NEW FINISH IS CALLED FOR ON AN EXISTING SURFACE, REMOVE THE EXISTING FINISH AND <br />PREPARE EXISTING SURFACE TO RECEIVE THE NEW FINISH.) <br />5. SEE MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL AND DRAWINGS FOR DEMOLITION <br />OF UTILITIES. <br />6. AT ALL WALLS/PARTITIONS/BARRIERS, FLOORS AND ROOFS WHICH ENCLOSE OR TOUCH SPACES <br />WHERE WORK IS BEING PERFORMED AS A PART OF THIS PROJECT, THE CONTRACTOR SHALL VERIFY <br />THAT THIS EXISTING CONSTRUCTION (INCLUDING DAMPERS, DUCT PENETRATIONS, DOORS, <br />WINDOWS, FRAMES, ETC.) MEETS THE FIRE, SMOKE AND SOUND ASSEMBLY RATINGS DESIGNATED <br />ON THESE DRAWINGS. THE CONTRATOR SHALL ALSO MAKE ANY REPAIRS AND/OR MODIFICATIONS <br />NECESSARY TO BRING THE EXISTING CONSTRUCTION (INCLUDING DAMPERS, DUCT PENETRATIONS, <br />DOORS, WINDOWS, FRAMES, ETC.) UP TO THE PROPER INDICATED FIRE, SMOKE AND SOUND <br />ASSEMBLY RATINGS. DOORS, WINDOWS AND FRAMES WHICH DO NOT MEET THE REQUIREMENTS OF <br />THE DESIGNATED WALL/PARTITION/BARRIER ASSEMBLIES (INCLUDING PROPER LABELS) SHALL BE <br />REPLACED. THE GENERAL CONTRACTOR SHALL DESIGNATE AN ALLOWANCE FOR THIS WORK. <br />7. DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND ORDINANCES <br />AS SET FORTH BY ALL AUTHORITIES HAVING JURISDICTION. <br />8. THE CONTRACTOR SHALL BRACE ALL EXISTING STRUCTURES AND ALL STRUCTURAL ELEMENTS <br />AS NECESSARY DURING DEMOLITION. <br />9. THE CONTRACTOR SHALL NOT CUT EXISTING OR NEW STRUCTURAL WORK IN ANY MANNER THAT <br />MAY RESULT IN A REDUCTION OF LOAD CARRYING CAPACITY OR LOAD/DEFLECTION RATIO. THE <br />CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF ALL STRUCTURAL CUTS PRIOR TO <br />EXECUTION SO THAT APPROVAL CAN BE OBTAINED IN ADVANCE FROM THE ARCHITECT. <br />10. WHERE EXISTING CONSTRUCTION IS FOUND TO CONTAIN ANY HAZARDOUS MATERIAL, THE <br />CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND THE ARCHITECT IN WRITING. NOTE: <br />REMOVAL, DISPOSAL AND REPLACEMENT OF THE HAZARDOUS MATERIAL IS THE SOLE <br />RESPONSIBILITY OF THE OWNER. <br />11. THE CONTRACTOR SHALL REPLACE OR REPAIR ANY EXISTING -TO -REMAIN MATERIALS AND <br />FINISHES (CEILING GRID, CEILING TILE, GYPSUM BOARD, FINISHES, DOORS, WINDOWS, FRAMES, <br />WALL PROTECTION, ETC.) WHICH ARE DAMAGED DURING DEMOLITION OR CONSTRUCTION. <br />12.THE CONTRACTOR SHALL COORDINATE ALL ICRA REQUIREMENTS WITH THE OWNER. <br />13.ALL WORK TO BE COMPLETED OUTSIDE THE AREA OF CONSTRUCTION SHALL BE ISOLATED TO <br />PORTABLE "DUST -BUGGIES" OR WORK BOOTHS. <br />14.SEAL ALL EXISTING AND ABANDONED PIPE OR CONDUIT PENETRATIONS IN ACCORDANCE WITH <br />THE APPROPRIATE U.L. DESIGN. <br />15.BUNDLE TIE AND INDEPENDENTLY SUPPORT ALL NEW AND EXISTING LOW VOLTAGE CABLING <br />ABOVE THE CEILING. <br />16.REMOVE ALL EXISTING ABANDONED CEILING MOUNTED HANGER WIRES, SUPPORT BRACKETS, <br />HANGER RODS, AND MOUNTING STRAPS. <br />17.IN ACCORDANCE WITH NFPA 51B AND NFPA 601, THE CONTRACTOR SHALL OBTAIN A HOT WORK <br />PERMIT PRIOR TO BEGINNING ANY WELDING, CUTTING, BRAZING, GRINDING OR OTHER ACTIVITIES <br />THAT GENERATES SPARK CAPABLE OF CAUSING COMBUSTION. <br />18.AS REQUIRED BY NFPA, REMOVE ALL FLAMMABLE ITEMS, INCLUDING BUT LIMITED TO <br />COMPRESSED AIR AND GAS CANS OR CYLINDERS (I.E. BRAZING, ACETYLENE, PROPANE TANKS, <br />PAINT CANS, LUBRICANTS, ETC.) FROM THE JOB SITE WHEN THE PROJECT HAS BEEN VACATED BY <br />CONSTRUCTION PERSONNEL AND DURING THE TIME THE FIRE ALARM SYSTEM AND FIRE <br />SUPPRESSION SYSTEM IS INACTIVE. <br />19. ALL MODIFICATIONS TO THE FIRE ALARM OR FIRE SPRINKLER SYSTEM, INCLUDING AUDIOVISUAL <br />COMMUNICATION DEVICES, SHALL BE DEFERRED TO THE CITY UNDER SEPARATE SUBMITTAL. <br />20. REMOVE PORTION OF EXISTING SLAB AS REQUIRED TO INSTALL NEW PLUMBING. COORDINATE <br />WITH PLUMBING DRAWINGS. <br />i <br />GENERAL NOTES FOR NEW CONSTRUCTION <br />AND DIMENSION PLANS. <br />1. COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING NOTES IN THIS SET OF DRAWINGS WHICH <br />ALSO APPLY TO THE NEW CONSTRUCTION AND DIMENSION FLOOR PLANS: <br />A. "GENERAL NOTES" ON THIS SHEET <br />B. "GENERAL NOTES FOR DEMOLITION PLANS" ON THIS SHEET <br />C. "GENERAL NOTES FOR REFLECTED CEILING PLANS" ON THIS SHEET <br />2. EXISTING -TO -REMAIN PARTITIONS/BARRIERS, DOORS, WINDOWS, PLUMBING FIXTURES, <br />CABINETWORK/CASEWORK, EQUIPMENT, ETC., ARE "SCREENED -BACK" AND ON NEW CONSTRUCTION <br />AND DIMENSION PLANS ARE INDICATED BY SOLID LINES. REFER TO DEMOLITION FLOOR PLANS FOR <br />EXTENT OF "EXISTING -TO -BE -REMOVED". <br />3. ITEMS DENOTED ON THE NEW CONSTRUCTION FLOOR PLANS WITH A DASHED LINE OR DOTTED LINES <br />ARE BEING FURNISHED BY THE OWNER OR INDICATE ITEMS OVERHEAD. (COMPLY WITH THE <br />REQUIREMENTS OF "GENERAL NOTES" ON NOTES AND ABBREVIATIONS SHEET) <br />4. SEE REFLECTED CEILING PLANS FOR LOCATIONS OF GYPSUM BOARD FURR DOWNS AND SOFFITS. <br />5. REFER TO THE A-500 SERIES FOR DETAILS WHICH APPLY TO THE FLOOR PLANS. <br />6. SEE INTERIOR DESIGN DRAWINGS FOR INTERIOR FINISHES AND FOR LOCATIONS OF ACCENT WALLS <br />AND WALL PROTECTION. <br />7. PROVIDE 5/8 INCH TYPE "X" GLASS MAT PAPERLESS INTERIOR GYPSUM BOARD AT WET LOCATIONS. <br />8. WHERE DEMOLITION OF CERTAIN ITEMS RESULTS IN UNPROTECTED OPENINGS OR PENETRATIONS IN <br />EXISTING -TO -REMAIN FLOORS, WALLS, CEILING, ROOFS, ETC., REPAIR SUCH OPENINGS AND <br />PENETRATIONS AS REQUIRED TO MEET ORIGINAL FIRE PROTECTION, SOUND AND STRUCTURAL <br />REQUIREMENTS. <br />9. FOR ADDITIONAL DIMENSIONING, COMPLY WITH REQUIREMENTS ON ENLARGED PLANS, WALL <br />SECTIONS, INTERIOR ELEVATIONS, PLAN DETAILS AND SECTION DETAILS. <br />10. THE CONTRACTOR SHALL NOT SCALE THE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE <br />CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT IN <br />WRITING PRIOR TO CONTINUING WITH CONSTRUCTION. <br />11. DIMENSIONS SHOWN ON THE FLOOR PLANS ARE: TO FACE OF STUD AT METAL STUD <br />PARTITIONS/BARRIERS OR TO OUTSIDE FACE OF EXISTING WALLS. EXTREMELY CRITICAL MINIMUM <br />DIMENSIONS MAY BE INDICATED AS "MINIMUM", "CLEAR", OR "MINIMUM CLEAR". <br />12. CRITICAL NOTE: THE CONTRACTOR SHALL TAKE INTO ACCOUNT THE THICKNESSES OF THE <br />SCHEDULED FINISH MATERIALS PRIOR TO "LAYING OUT" METAL STUD PARTITIONS/BARRIERS, SINCE THE <br />TOTAL "OUT -TO -OUT" WALL THICKNESS MUST BE CONSIDERED SO THAT THE REQUIRED "MINIMUM <br />FACE -OF -FINISH" AND "MINIMUM CLEAR FACE -OF -FINISH" DIMENSIONS CAN BE MAINTAINED AFTER THE <br />INSTALLATION OF THE FINISH MATERIALS. <br />13. INTERIOR METAL STUD PARTITIONS/BARRIERS SHALL BE CONSTRUCTED OF 3 5/8" (MINIMUM) METAL <br />STUDS (OR AS SHOWN BELOW) UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL ALSO COMPLY <br />WITH U.L. DESIGN NO. U444 OR U458 AT RATED PLUMBING WALLS/BARRIERS. <br />14. WHERE NEW GYPSUM BOARD PARTITIONS/BARRIERS ARE A CONTINUATION OF AN EXISTING WALL <br />OR COLUMN ENCASEMENT, THE FACE OF NEW GYPSUM BOARD SHALL BE ALIGNED WITH FACE OF <br />EXISTING SURFACE. WHERE A ONE -HOUR RATED BARRIER OR A NON -RATED PARTITION IS SHOWN AS A <br />CONTINUATION OF A TWO-HOUR RATED BARRIER OR COLUMN ENCASEMENT, THE OUTSIDE FACE OF <br />THE GYPSUM BOARD SHALL BE ALIGNED. STUDS SHALL BE OFFSET AND/OR ADDITIONAL LAYERS OF <br />GYPSUM BOARD SHALL BE PROVIDED (AS REQUIRED TO PROVIDE FACE ALIGNMENT OF GYPSUM <br />BOARD) WHILE MAINTAINING THE REQUIRED RATED INTEGRITY. <br />15. TYPICAL PARTITION TYPE IS "A" UNLESS OTHERWISE NOTED. <br />16. PATCH ANY EXISTING TO REMAIN WALLS AND RESKIM/REFINISH WALL SURFACE. REPAINT ANY <br />EXISTING TO REMAIN WALLS, HOLLOW METAL DOOR FRAMES AND TRIM. <br />GENERAL NOTES FOR REFLECTED CEILING PLANS: <br />1. COMPLY WITH THE FOLLOWING NOTES IN THIS SET OF DRAWINGS WHICH ALSO APPLY TO THE <br />REFLECTED CEILING PLANS: <br />A. "GENERAL NOTES" ON THIS SHEET <br />B. "GENERAL NOTES FOR DEMOLITION PLANS" ON THIS SHEET <br />C. "GENERAL NOTES FOR NEW CONSTRUCTION AND DIMENSION PLANS" ON THIS SHEET <br />2. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE REFLECTED CEILING PLANS <br />WITH: ELECTRICAL'S LIGHTING, SYSTEMS AND COMMUNICATIONS DRAWINGS; MECHANICAL'S <br />SUPPLY, RETURN AND EXHAUST DRAWINGS; AND FIRE PROTECTION'S DRAWINGS IF APPLICABLE. <br />THE CONTRACTOR SHALL THEN IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY <br />ERROR, INCONSISTENCY OR OMISSION THAT IS DISCOVERED. <br />3. SEE ELECTRICAL, COMMUNICATION, SECURITY AND FIRE PROTECTION DRAWINGS FOR <br />LOCATIONS OF CEILING MOUNTED SMOKE DETECTORS, COMMUNICATION DEVICES, FIRE ALARM <br />DEVICES, SECURITY DEVICES, ETC. <br />4. ONLY CEILING MOUNTED EXIT LIGHTS ARE SHOWN ON THE REFLECTED CEILING PLANS. SEE <br />THE ELECTRICAL DRAWINGS FOR LOCATIONS OF WALL MOUNTED EXIT LIGHTS. (NOTE: THE <br />BOTTOM OF EXIT LIGHTS SHALL BE A MINIMUM OF T-0" CLEAR AFF.) <br />5. SPRINKLER HEADS: <br />A. THE SPRINKLER HEADS ARE NOT SHOWN ON THE REFLECTED CEILING PLANS. REFER <br />TO FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION. <br />B. THE CONTRACTOR SHALL RELOCATE AND/OR INSTALL SUFFICIENT HEADS IN ALL <br />SPACES TO PROVIDE COMPLETE (100%) AUTOMATIC SPRINKLER COVERAGE AS DEFINED <br />IN NFPA STANDARD 13, - FIRE SUPPRESSION AND AS SHOWN ON THE FIRE PROTECTION <br />DRAWINGS. <br />C. NEITHER SPRINKLER HEADS OR CONCEALED SPRINKLER HEAD COVERS ARE ALLOWED <br />TO BE PAINTED. THE CONTRACTOR SHALL VERIFY THAT ANY SPRINKLER HEADS THAT ARE <br />ACCIDENTALLY PAINTED ARE REMOVED FROM THE SITE AND REPLACED WITH NEW ONES. <br />6. THE CONTRACTOR SHALL ADVISE THE OWNER AND TENANTS THAT AN 18 INCH MINIMUM <br />VERTICAL CLEARANCE SHALL BE MAINTAINED BETWEEN THE BOTTOM OF THE EXTENDED (DROP <br />DOWN) SPRINKLER HEADS AND THE TOP OF ANY FILES, SHELVING, EQUIPMENT, LOCKERS, ETC., <br />(WHETHER CONTRACTOR OR OWNERFURNISHED). THE CONTRACTOR SHALL ALSO ADVISE THE <br />OWNER AND TENANTS THAT ITEMS SHALL NOT BE PLACED OR STORED ON TOP OF SHELVING SO <br />THAT THIS CODE REQUIRED 18 INCH MINIMUM VERTICAL CLEARANCE WILL BE MAINTAINED. <br />7. PROVIDE GYPSUM BOARD FURR-DOWNS OVER ALL WALL CABINETS. SEE A-500 SERIES FOR <br />DETAILS. <br />8. WHERE EXISTING LAY -IN CEILING GRIDS ARE REMOVED AND RE -INSTALLED, THE CONTRACTOR <br />SHALL TAKE CARE NOT TO DAMAGE THE GRID. ANY DAMAGED GRID SHALL BE REPLACED WITH <br />NEW MATERIAL. THESE NEW MATERIALS SHALL MATCH THE EXISTING IN A UNIFORM MANNER <br />FOR COLOR, TEXTURE, PATTERN, ETC. IF UNIFORMITY CANNOT BE ACHIEVED, THE CONTRACTOR <br />SHALL REPLACE THE ENTIRE CEILING WITHIN THAT SPACE WITH NEW MATERIAL. THE <br />CONTRACTOR SHALL PROVIDE NEW MATERIAL AS APPROVED BY BOTH OWNER AND ARCHITECT <br />IN WRITING. <br />9. THE "LIMITS OF CONSTRUCTION" LINES SHOWN ON THE ARCHITECT'S REFLECTED CEILING <br />PLANS APPLY ONLY TO THE LIMITS OF THE ARCHITECTURAL NEW CONSTRUCTION AND <br />RENOVATION. SEE THE OTHER DISCIPLINES' DRAWINGS FOR THE LIMITS OF THE NEW <br />CONSTRUCTION AND RENOVATION FOR THEIR DISCIPLINE. <br />10, SEE THE INTERIOR DESIGN DRAWINGS FOR THE PAINT SPECIFICATIONS AND COLORS OF <br />PAINTED CEILINGS AND INTERIOR SOFFITS. HORIZONTAL SURFACES OF SOFFITS SHALL BE <br />PAINTED THE SAME COLOR AS THE VERTICAL SURFACES, UNLESS NOTED OTHERWISE. <br />11. RECESSED CAN LIGHT FIXTURES: <br />A. THE RECESSED CAN LIGHT FIXTURES SHALL BE CENTERED IN GYPSUM BOARD <br />SOFFITS, U.N.O <br />B. THE RECESSED CAN LIGHT FIXTURES SHALL BE CENTERED IN THE CEILING TILE, U.N.O. <br />C. RECESSED CAN LIGHT FIXTURES IN A SERIES SHALL BE ALIGNED AND EQUALLY <br />SPACED, U.N.O. <br />GENERAL PROJE <br />CT CT NOTES. E <br />1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES, STANDARDS AND GOVERNING <br />AUTHORITIES. <br />2. THESE DRAWINGS ARE ISSUED IN CONJUNCTION WITH THE PROJECT MANUAL OF THE SAME DATE, <br />TITLE AND PROJECT NUMBER AND TOGETHER ARE REFERRED TO AS "CONTRACT DOCUMENTS." <br />3. REFER TO ARCHITECTURAL, INTERIOR DESIGN, MECHANICAL, PLUMBING, FIRE PROTECTION AND <br />ELECTRICAL DRAWINGS FOR COORDINATION OF WORK. <br />4. NOTES APPEAR ON A NUMBER OF DRAWINGS FOR DIFFERENT SYSTEMS AND MATERIALS. <br />REFERENCE ALL ISSUED CONTRACT DOCUMENTS TO APPLY APPLICABLE NOTES, SYMBOLS AND <br />ABBREVIATIONS TO BUILDING COMPONENTS. <br />5. DO NOT SCALE THE DRAWINGS. <br />6. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME KNOWLEDGEABLE OF CONDITIONS. THE <br />CONTRACTOR SHALL INVESTIGATE, VERIFY AND BE RESPONSIBLE FOR ALL THE REQUIREMENTS OF <br />THE PROJECT AND SHALL NOTIFY THE OWNER AND ARCHITECT OF ANY EXISTING CONDITIONS <br />REQUIRING INFORMATION BEFORE PROCEEDING WITH ANY WORK. <br />7. THE CONTRACTOR SHALL PROTECT ALL EXISTING SITE ELEMENTS FROM DAMAGE DUE TO <br />ALTERATION AND CONSTRUCTION OPERATIONS AND THEY SHALL REPAIR OR REPLACE ELEMENTS <br />DAMAGED DURING THE PROJECT. <br />8. ANY UTILITY SHUT -OFFS AS REQUIRED BY THE CONTRACTOR FOR COMPLETION OF THE WORK <br />SUCH AS ELECTRICAL, GAS, WATER, SEWER, STEAM, ETC., MUST BE SCHEDULED WITH THE OWNER, <br />ARCHITECT AND UTILITY COMPANY PRIOR TO COMMENCING WORK. <br />9. DETAILS SHOWN ARE INTENDED TO BE INDICATIVE OF THE PROFILES AND TYPE OF DETAILING <br />REQUIRED FOR THE WORK. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. <br />10. UNLESS NOTED OTHERWISE, ALL FASTENERS AND FASTENING DEVICES ARE TO BE CONCEALED IN <br />ALL FINISHED SPACES. <br />11. ANY PIPING, DUCTS, CONDUITS, ETC. THAT PENETRATE FIRE RATED FLOOR SLABS AND WALLS <br />SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE FIRE INTEGRITY OF THE FLOOR OR <br />WALL. FIRE STOP RATINGS SHALL MATCH RATINGS OF FLOORS OR WALLS WHERE PENETRATIONS <br />OCCUR. PROVIDE FIRE DAMPERS IN DUCTS PENETRATING FIRE -RATED WALLS AND FLOORS TO MEET <br />THE APPLICABLE BUILDING CODES. <br />12. ALL JOINTS OF ANY ELEMENT OF CONSTRUCTION WHICH ARE REQUIRED TO HAVE A FIRE <br />RESISTANCE RATING SHALL BE INSTALLED PER THE MANUFACTURER'S PUBLISHED TESTED <br />ASSEMBLIES, SHALL BE TIGHT AND SHALL PREVENT THE PASSAGE OF SMOKE AND FLAME. <br />13. WHERE THE FIRE RATINGS OF WALLS ARE NOTED ON THE DRAWINGS, THE FIRE RATING SHALL <br />APPLY TO THE ENTIRE PERIMETER ENCLOSURE OF THE ROOM OR SPACE FOR THE FULL LENGTH AND <br />HEIGHT OF AREAS BEING SEPARATED, EXTENDING TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK. <br />14. PROVIDE FIRE STOPS TO SEPARATE WALL CAVITIES FROM HORIZONTAL PLENUM AREAS AND <br />BETWEEN FLOORS TO CLOSE OPENINGS. FIRE RATING OF STOPS SHALL MATCH THE FIRE RATING OF <br />VERTICAL SEPARATION OR FLOOR CONSTRUCTION, WHICHEVER IS GREATER. <br />15. CONSTRUCTION AROUND CABINETS, PANELS AND BOXES RECESSED IN FIRE -RATED FLOOR, WALL <br />AND CEILING ASSEMBLIES SHALL MAINTAIN THE FIRE -RATING NOTED IN THE DRAWINGS. <br />16. OPENINGS IN WALL, CEILING, FLOOR AND ROOF ASSEMBLIES SHALL BE SEALED WITH <br />PENETRATION SEALANT SYSTEMS THAT MEET OR EXCEED THE REQUIRED FIRE RATINGS. <br />17. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER BY GASKETS OR <br />COATINGS OR BOTH TO AVOID GALVANIC CORROSION ACTION. <br />18. PATCH FIREPROOFING TO MATCH EXISTING. <br />19. SEE MECHANICAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL DRAWINGS TO DETERMINE <br />QUANTITIES OF DIFFUSERS, GRILLES, LIGHT FIXTURES, SPRINKLER HEADS, ETC. <br />20. PIPE AND COLUMN FURRING SHALL BE HELD AS CLOSE TO THE PIPING AND/OR COLUMNS AS <br />POSSIBLE, UNLESS NOTED OTHERWISE. <br />21. THE EXTENT OF THE WORK SHOWN ON THE PLANS AND DETAILS REFLECTS THE BEST JUDGMENT <br />OF THE ARCHITECT/ENGINEER. THE CONTRACTOR SHALL FAMILIARIZE HIM/HERSELF WITH THE <br />EXISTING CONDITIONS AND ADVISE THE ARCHITECT, IN WRITING, OF ANY SITUATION THAT WOULD NOT <br />ALLOW HIM/HER TO PROCEED ON THE BASIS OF THESE DOCUMENTS. <br />22. THE ARCHITECT/ENGINEER'S SELECTION OF MATERIALS AND DETAILS DOES NOT RELIEVE THE <br />CONTRACTOR FROM VERIFYING WITH THE MATERIAL SUPPLIERS THAT THE PROPOSED MATERIALS <br />ARE CORRECT AND PROPER FOR THE INTENDED APPLICATION AND USE. <br />23. CONCRETE FILLS ABOVE STRUCTURAL SLABS SHALL BE REINFORCED. REFER TO STRUCTURAL <br />DRAWINGS FOR ADDITIONAL REQUIREMENTS. <br />24. UNLESS NOTED OTHERWISE, WHERE AN ARCHITECTURAL FINISHED FLOOR IS TO BE PROVIDED <br />(REQUIRING A DEPRESSED STRUCTURAL SLAB), THE FLOOR ELEVATIONS ARE TO TOP OF FINISHED <br />FLOOR. WHERE AN ARCHITECTURAL FINISHED FLOOR IS INTENDED FOR SURFACE APPLICATION, THE <br />FLOOR ELEVATIONS ARE TO TOP OF STRUCTURAL SLAB. REFER TO STRUCTURAL DRAWINGS FOR <br />LOCATION OF DEPRESSED SLABS. <br />25. UNLESS NOTED OTHERWISE, CONCRETE PAD WITH REINFORCING SHALL BE INSTALLED UNDER ALL <br />FLOOR MOUNTED MECHANICAL AND ELECTRICAL EQUIPMENT. REFER TO MECHANICAL, ELECTRICAL, <br />PLUMBING AND FIRE PROTECTION DRAWINGS FOR THE EXTENT OF EQUIPMENT PADS. THE <br />CONTRACTOR SHALL COORDINATE THE SIZE, THICKNESS AND LOCATION OF THE CONCRETE PADS <br />WITH THE EQUIPMENT INSTALLER. <br />26. AT THOSE PLACES WHERE MATERIALS ARE APPLIED TO, OR ARE IN DIRECT CONTACT WITH WORK <br />INSTALLED BY ANOTHER SUBCONTRACTOR, COMMENCEMENT OF WORK IMPLIES THE ACCEPTANCE OF <br />THE SUBSTRATE AND EXISTING CONDITIONS AS SUITABLE FOR THE APPLICATION INTENDED. <br />27. ALL WORK SHALL BE EXECUTED IN A WORKMANLIKE MANNER. CONSTRUCTION OF NEW <br />HORIZONTAL SURFACES SHALL BE LEVEL AND FLAT AND NEW VERTICAL SURFACES SHALL BE <br />CONSTRUCTED TO BE PLUMB, UNLESS NOTED OTHERWISE. <br />28. WHERE NOT INDICATED, PROVIDE BLOCKING IN WALLS, SOFFITS, AND CEILINGS RECEIVING <br />SIGNAGE, COAT HOOKS, LOCKERS, MARKER BOARDS, AND OTHER MOUNTED ITEMS, ACCORDING TO <br />THE MANUFACTURER'S RECOMMENDATIONS. <br />29, CONTINUOUS PERIMETER FIRE SAFING BETWEEN FLOORS SHALL BE PROVIDED AND <br />COORDINATED WITH THE EXTERIOR WALL SYSTEMS AND ASSEMBLIES. THE FIRE SAFING'S RATING <br />SHALL MATCH OR EXCEED THAT OF THE FLOOR CONSTRUCTION RATING. <br />30. CONTINUOUS PERIMETER FIRE SAFING BETWEEN FLOORS SHALL BE PROVIDED AND <br />COORDINATED WITH THE EXTERIOR WALL SYSTEMS AND ASSEMBLIES. THE FIRE SAFING'S RATING <br />SHALL MATCH OR EXCEED THAT OF THE FLOOR CONSTRUCTION RATING. <br />31. CONTRACTOR TO CONFIRM AND FIELD VERIFY DIMENSIONS TO COORDINATE WITH OWNER <br />PROVIDED EQUIPMENT AND FURNISHINGS. <br />32. SUBSTITUTIONS OF MATERIALS MAY OCCUR IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, <br />AND ONLY IF AUTHORIZED BY THE ARCHITECT. <br />33. CONTRACTOR SHALL PERFORM FIELD VERIFICATION OF ALL THE EXISTING CONDITIONS ON THE <br />SITE AND SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES AND SHALL COMPARE THE <br />INFORMATION TO THE CONTRACT DOCUMENTS PRIOR TO THE COMMENCEMENT OF ALL WORK. THE <br />CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. <br />34. ALL CONTRACTOR PROVIDED MATERIALS SHALL BE NEW AND DELIVERED AND INSTALLED IN GOOD <br />CONDITION AND WITHOUT ANY DEFECTS. <br />35. ANY WORK NOT CONFORMING TO THESE SPECIFICATIONS WILL BE REJECTED. THE ARCHITECT OR <br />THE OWNER MAY REJECT THE WORK AND REJECTED WORK WILL BE REMOVED AND REPLACED AT NO <br />ADDITIONAL COST TO THE OWNER. <br />36. CONTRACT DOCUMENTS ARE INCLUSIVE OF ALL DISCIPLINES DRAWINGS AND SPECIFICATIONS. <br />THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION ACROSS ALL DRAWINGS. <br />RS&H <br />1715 N. Westshore Blvd., Suite 600 <br />Tampa„ Florida 33607-3999 <br />904-256-2500 Fax 904-256-2503 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * G6238 <br />Advent Health <br />PROJECT TITLE: <br />KITCHEN RENOVATION <br />ADVENTHEALTH ZEPHYRHILLS <br />PROJECT ADDRESS: <br />7050 Gall Blvd. Zephyrhills, FL 33541 <br />SEAL <br />boo-JIN KjM <br />AR95652 <br />Nftlly v9-d by Y-4m Kim <br />DN: D=US, <br />E=yoalln.kim*rsandh com, <br />Yoo-Jin Kim D=RBN.CN=Yoo-JmKim <br />D. 2020 04.09 <br />09:30.42-0400' <br />SIGNATURE <br />REVISIONS <br />NO. DESCRIPTION DATE <br />DATE ISSUED: 03/20/2020 <br />REVIEWED BY: YK <br />DRAWN BY: YK/KN <br />DESIGNED BY: JS <br />PROJECT NUMBER: <br />504- 0226- 000 <br />0 2019 RS&H, INC. <br />SHEET TITLE: <br />GENERAL NOTES <br />SHEET ID: <br />G002 <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />Copyright 0 2018. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />2 <br />3 <br />4 <br />5 <br />j <br />