My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (109)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (109)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 1:19:12 PM
Creation date
2/19/2025 8:37:49 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Berglund Construction
Building Plans - Permit #
738
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br />1 2 <br />3 <br />W <br />5 <br />D <br />C <br />0 <br />A <br />a <br />0 <br />th <br />N <br />0 <br />N <br />O <br />N <br />M <br />N <br />M <br />FLOOR GRADE <br />Cl; nr)r'Irr) 1KIT A I/ r- <br />L <br />OA INTAKE DUCT ELEVATION <br />SCALE: 1/4" = l'-0" <br />3' 0" <br />CONDENSING UNITS BY OTHER. <br />EXISTING PROVIDE EQUIPMENT SUPPORTS. <br />TRANSFORMERS CU SEE STRUCTURAL DRAWINGS FOR <br />MORE INFORMATION <br />!o <br />M <br />OUTDOOR AIR DLUI <br />INTAKE ON THIS SIDE 5 PROVIDE OA INTAKE 78"x48" <br />M 02 BOX AND TAP OFF WITH A <br />54"x24". SEE ELEVATION ON <br />/ THIS SHEET FOR MORE <br />4' 2 7/16" INFORMATION <br />' I <br />3'-0" <br />NEW 8" CONCRETE <br />PAD ABOVE GRADE <br />ACCESS DOORS <br />ON THIS SIDE <br />I <br />O FL_li <br />1NG RTU <br />i <br />X <br />"Y' <br />X <br />\ <br />i \ <br />, <br />X <br />OCONNECT TO <br />EXISTING 12"x 12" <br />-WALL OPENING OUTDOOR AIR DUCT_- -.. <br />RHC-5 <br />-1 RHC- <br />24x56 1C 500 1 C 500 <br />I I <br />0 <br />X <br />o VFD <br />RHC-4 <br />II <br />1� <br />RHC-3 <br />i <br />1 <br />d 1 <br />1 16x4 DUCT <br />1 DOWN <br />325 - <br />�✓ �� l 1 10e <br />E 300 <br />y� l <br />200 CFM LOADING END I AND 400 CFM EXHAUST <br />ON UNLOADING END <br />MW_: <br />LEVEL 1 RENOVATION - PHASE 2 - DUCTWORK <br />1 SCALE: 1/8" = V-0" <br />Copyright © 2018. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the 2 <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />CONSTRUCTION ZONE/%: <br />u <br />S 300 R 300 <br />12x12 <br />18x 10 <br />��- -®.. <br />�2 D 400 <br />I� 1 <br />C 400 e �i <br />400 E 550 <br />20x8 I <br />26x14 i I <br />1 r <br />- - - <br />24x16 <br />- <br />X <br />1 <br />j 250 <br />1 <br />1 <br />i <br />1 <br />1 <br />_ <br />1 <br />1 <br />4 , <br />1 <br />1 <br />j <br />R 200 I <br />1 <br />1 <br />E 100 <br />`v E 550 i <br />6 <br />_ 1 <br />22x 13 <br />a <br />�� J� 1 <br />T <br />E 350 <br />(E)EF-41 <br />I 1 <br />:100 �, 1 <br />X D 1 <br />300 �- <br />I <br />150 CFM <br />\LL <br />B 150 <br />U <br />0 <br />0 <br />N <br />R 150- <br />0 <br />4 <br />GENERAL NOTES. <br />1. ALL REHEAT COILS SHALL BE ACCESSIBLE THROUGH LAY -IN <br />CEILING. WHERE CEILINGS ARE NOT ACCESIBLE AN ACCESS <br />DOOR SHALL BE PROVIDED. <br />2. PROVIDE ZERO CLEARANCE ASTM E-2336 LISTED FACTORY <br />BUILT 20 GAGE GALVANIZED SHEET STEEL GREASE DUCT <br />INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S <br />INSTRUCTIONS AND THE LISTING REQUIREMENTS FOR ALL <br />KITCHEN HOOD EXHAUST DUCTWORK. PROVIDE FLAMEBAR <br />BW11/UNIFRAX FYREWRAP WITH 2 HR FIRE RATING (OR <br />APPROVED EQUIVALENT). <br />3. ALL GREASE DUCTS SHALL SLOPE 1/4" FOR 1' LENGTH TOWARD <br />HOOD OR GREASE DUCT CLEANOUT. HORIZONTAL DUCT RUNS <br />THAT ARE GREATER THAN 75', SHALL BE SLOPED AT 1" PER 1' <br />LENGTH TOWARD HOOD OR GREASE DUCT CLEANOUT. <br />4. COORDINATE ALL AHU AND EXHAUST FAN SHUT DOWNS WITH <br />OWNER, PROVIDE MINIMUM TWO WEEKS ADVANCE NOTICE FOR <br />DOWNTIME. <br />5. TYPE II HOOD EXHAUST DUCTWORK AND DISHWASH AREA <br />EXHAUST DUCTWORK SHALL BE WELDED STAINLESS STEEL. <br />AHU-1 REBALANCE <br />SCHEDULE <br />SUPPLY RETURN OUTSIDE AIR <br />OLD 15,500 0 15,500 <br />NEW 13,125 0 13,125 <br />NOTES: <br />1. ADJUST VFD AS NECESSARY TO COMPLETE AIR BALANCE. <br />2. T&B CONTRACTOR SHALL PROVIDE ALL BELTS AND SHEAVES AS <br />NECESSARY TO COMPLETE AIR BALANCE. <br />3. PROVIDE FULL PRE -DEMO AND FINAL REPORT INCLUDING SUPPLY <br />FAN DATA. <br />AHU -3A REBALANCE <br />SCHEDULE <br />SUPPLY <br />RETURN <br />OUTSIDE AIR <br />OLD <br />2,000 <br />0 <br />0 <br />NEW <br />1,500 <br />1,200 <br />300 <br />NOTES: <br />1. ADJUST VFD AS NECESSARY TO COMPLETE AIR BALANCE. <br />2. T&B CONTRACTOR SHALL. PROVIDE ALL BELTS AND SHEAVES AS <br />NECESSARY TO COMPLETE AIR BALANCE. <br />3. PROVIDE FULL PRE -DEMO AND FINAL REPORT INCLUDING SUPPLY <br />FAN DATA. <br />0 HVAC KEY NOTES: <br />0 FABRICATED DUCTWORK MADE FROM STAINLESS STEEL <br />CONFORMING TO ASTM A430, TYPE 304 WITH 2B FINISH, ALL <br />WELDED CONSTRUCTION. PROVIDE VOLUME DAMPER ON EACH <br />DROP, SEE DISHWASHER VENDOR CUTSHEETS FOR ADDITIONAL <br />INFORMATION. SLOPE DUCT AT A MINIMUM OF 1/8 TOWARDS <br />DISHWASHER UNIT. <br />O2 34"x26" ZERO CLEARANCE FACTORY ASSEMPLED GREASE DUCT <br />WITH 2 LAYERS OF 2 HOUR FIRE WRAP UP TO EF2-1 ON 3RD <br />LEVEL ROOF, FIELD VERIFY EXACT SIZE AND LOCATION OF <br />EXISTING CHASE. <br />0 NEW AHU-3A MOUNTED ON 4" CONCRETE PAD, FIELD <br />COORDINATE NEW DUCTWORK WITH EXISTING FIRE SPRINKLER <br />AND MECHANICAL PIPING. WHERE NECCESSARY REROUTE <br />PIPING TO ACCOMUDATE NEW DUCTWORK. <br />® REBALANCE ALL AIR DISTRIBUTION DEVICES ASSOCIATED WITH <br />REPLACEMENT UNIT. <br />O5 REBALANCE EXISTING EXHAUST FAN. SEE REBALANCE <br />SCHEDULE FOR MORE INFORMATION. <br />© PROPOSED HOOD PULL STATION LOCATION. SEE HOOD <br />MANUFACTURER DRAWINGS FOR ADDITIONAL INFORMATION, <br />PULL STATION LOCATION SHALL COMPLY WITH REQUIREMENTS <br />FROM NFPA 17A. <br />EF REBALANCE <br />SCHEDULE <br />MARK OLD NE� <br />(E)EF-41 2,150 1,850 <br />NOTES,- <br />1. T&B CONTRACTOR SHALL PROVIDE ALL BELTS AND SHEAVES AS <br />NECESSARY TO COMPLETE AIR BALANCE. <br />2. PROVIDE FULL PRE -DEMO AND FINAL REPORT <br />VENTILATION TABLE- PHASE 2 <br />ROOM <br />SUPPLY <br />RETURN <br />EXHAUST <br />CEILING <br />AREA <br />REQUIRED <br />DESIGN- <br />REQUIRED <br />DESIGN <br />HEIGHT <br />OA AC/HR <br />OA AC/HR <br />AC/HR <br />AC/HR <br />KITCHEN <br />8800 <br />0 <br />9225 <br />2600 <br />9.0 <br />2.0 <br />5.0 <br />10.0 <br />22.4 <br />SUPER. OFFICE <br />100 <br />0 <br />100 <br />105 <br />9.0 <br />N/A <br />0.0 <br />0.0 <br />6.35 <br />DISHWASH <br />1200 <br />0 <br />1500 <br />740 <br />8.0 <br />0.0 <br />0.0 <br />10.0 <br />15.7 <br />NOTE: <br />1.) THE REQUIRED OUTDOOR AIR AND AIR CHANGES ARE PER HEALTH CARE GUIDELINES AND ASHRAE 170 <br />2.) AIR CHANGES PER HOUR = CFM*601AREA*HEIGHT <br />1715 N. Westshore Blvd., Suite 600 <br />Tampa„ Florida 33607-3999 <br />904-256-2500 Fax 904-256-2503 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * GB238 <br />&.TLC <br />ENGINEERING <br />S O L U 1 1 U N <br />255 S. Orange Avenue <br />Suite 1600 <br />Orlando, FL 32801 <br />P 407.841.9050 <br />www.tic-engineers.com <br />COA 15 <br />© Copyright 2019 TLC Engineering Solutions, Inc. <br />TLC Project No.: 119333 <br />PROJECT TITLE: <br />KITCHEN RENOVATION <br />ADVENTHEALTH ZEPHYRHILLS <br />PROJECT ADDRESS: <br />7050 Gall Blvd. Zephyrhills, FL 33541 <br />Aaron Lee Johnson, P.E. <br />Florida License #71576 <br />1 LEE11Jpti'�,. <br />Q,O . • c'E'NS <br />No 71 576 ; <br />r <br />�?•• 5' f dyro�i <br />STATgiltplly <br />4u <br />,,.„ a _ <br />named upfm tico <br />SgnW Prntatld4emaIr-. <br />1�narKrtl am rql Wmdare0 s"6"', <br />o <br />a aemd ana W.N ft cv^ ;wP <br />AO`�3.25 <br />21:25:22-04'00' <br />o <br />O <br />U <br />H <br />Z <br />w <br />J <br />U <br />Q <br />U <br />a <br />REVISIONS <br />DATE ISSUED: 03/20/2020 <br />REVIEWED BY: <br />--_ ALJ <br />DRAWN BY: LLP <br />DESIGNED BY: LLP <br />PROJECT NUMBER: <br />504- 0226- 000 <br />© 2019 RS&H. INC. <br />SHEET TITLE: <br />LEVEL 1 RENOVATION <br />PLAN - PHASE 2 - <br />DUCTWORK <br />SHEET ID: <br />M102 <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />
The URL can be used to link to this page
Your browser does not support the video tag.