- -- I _ f_ I I I I _ - 11 I_� "'I� qVI <br />1 2 3 4 <br />5 <br />'11, J <br />M <br />C <br />BI <br />AI <br />2 <br />a <br />N <br />v <br />UD <br />N <br />LO <br />0 <br />0 <br />N <br />0 <br />N <br />Cl) <br />ELECTRICAL SYMBOL LEGEND <br />BASIC MATERIALS BASIC MATERIALS CONT. <br />SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br />S a SINGLE POLE SWITCH OUP CONDUIT TURNING UP <br />(SUBSCRIPT INDICATES ITEM CONTROLLED) <br />-♦DN CONDUIT TURNING DOWN <br />S3 THREE-WAY SWITCH <br />] CONDUIT STUB <br />S4 FOUR-WAY SWITCH <br />-� CONDUIT CONTINUED <br />S <br />P SINGLE POLE SWITCH <br />WITH PILOT LIGHT FLEXIBLE CONDUIT <br />DUPLEX RECEPTACLE - - - - - EXISTING TO BE REMOVED <br />TWIST LOCK RECEPTACLE EXISTING TO REMAIN <br />T <br />SURGE PROTECTION TYPE (TVSS) EXISTING AFFECTED BY THIS PROJECT <br />DUPLEX RECEPTACLE WITH - - - - FUTURE <br />EACH HALF ON SEPARATE CIRCUIT <br />(BREAKER SHALL BE TWO POLE WITH COMMON TRIP) NEW <br />DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER <br />DUPLEX SAFETY RECEPTACLE MOUNT LIGHTING <br />COVERPLATES WITH SPANNER HEAD SCREWS <br />A FIXTURE DESIGNATION <br />DUPLEX RECEPTACLE WITH TOP HALF SWITCHED [:�d LED FIXTURE <br />SIMPLEX RECEPTACLE (EWC DENOTES 2 a �►� <br />ELECTRIC WATER COOLER. COORDINATE WITH EWC LOWER CASE LETTER INDICATES <br />EWC INSTALLER FOR MOUNTING HEIGHT) CONTROL CIRCUIT SWITCH LEG <br />GFI RECEPTACLE MOUNTED ABOVE COUNTER CIRCUIT NUMBER <br />LED FIXTURE DIAGONAL SHADING DENOTES <br />0 TWO DUPLEX RECEPTACLES WITH COMMON COVER Ea TO LIGHT FIXTURE CONNECTED TO CRITICAL <br />TWO DUPLEX RECEPTACLES WITH COMMON COVER 0 LED FIXTURE <br />MOUNTED ABOVE COUNTER <br />EXIT LIGHT FIXTURE <br />ISOLATED GROUND DUPLEX RECEPTACLE, ® DIRECTION ARROWS AS SHOWN <br />IG (ORANGE DEVICE) (SHADED QUADRANT INDICATES FACE(S) OF <br />DUPLEX RECEPTACLE FIRE ALARM/DETECTION SYS <br />NOTE: <br />TICK MARKS SHOWN ON ANY DEVICE REPRESENTS <br />RECEPTACLE CONNECTED TO THE EMERGENCY CIRCUIT FD MANUAL PULL STATION <br />(RED DEVICE) TYPICAL FOR ANY DEVICE IN LEGEND <br />® CEILING SMOKE DETECTOR, PHOTO-ELECTRI <br />® SPECIAL PURPOSE RECEPTACLE, RATING AS NOTED TYPE UNLESS OTHERWISE NOTED <br />GN GROUND BAR DUCT SMOKE DETECTOR <br />® CABLE TRAY ® SUPERVISED CONTROL RELAY <br />Q JUNCTION BOX COMBINATION AUDIBLENISUAL NOTIFICATION <br />CHIME/FLASHING "FIRE" LIGHT <br />O CONDUIT SEAL -OFF FITTINGS XXCD CD = CANDELA RATING <br />SS C3 SURGE SUPRESSOR VISUAL SIGNALING UNIT, WALL MOUNTED <br />C3 = SERVICE ENTRANCE DEVICE F (NO AUDIO DEVICE) <br />B3 = DISTRIBUTION BOARD DEVICE FACP <br />A3 = PANELBOARD DEVICE 1�1 FIRE ALARM CONTROL PANEL <br />MSTSHUNT-TRIP BUTTON - FLUSH MOUNTED UNLESS <br />OTHERWISE NOTED NEMA 3R FOR EXTERIOR LOCATIONS GENERAL DEMOLITION NOT <br />© POWER CONNECTION TO EQUIPMENT <br />® MAGNETIC MOTOR STARTER OR CONTACTOR <br />SIZE AS NOTED 1. ALL DEVICES SHOWN ON DEMOLITION PLANS ARE EXISTING. <br />EDH-X REFER TO SYMBOL LEGEND FOR DEVICE DESCRIPTION. <br />ELECTRIC DUCT HEATER <br />2. EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE <br />MOTOR CONNECTION, NUMBER DENOTES HORSEPOWER TAKEN FROM ORIGINAL DRAWINGS AND FIELD <br />INVESTIGATION, ALL EXISTING CONDITIONS MUST BE <br />VF VARIABLE FREQUENCY DRIVE VERIFIED PRIOR TO BID. FIELD CONDITIONS SHALL GOVEN, <br />DD DIRECT DIGITAL CONTROL PANEL 3. THE DEMOLITION PLAN IS NOT INCLUSIVE OF ALL <br />ELECTRICAL DEVICES WITHIN THE PROJECT AREA. IT IS <br />INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL <br />TRANSFORMER KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE <br />PROJECT AREA, ANY DISCREPANCIES OR CONDITIONS NOT <br />SHOWN ON THIS PLAN SHALL BE BROUGHT TO THE <br />® AUTOMATIC TRANSFER SWITCH ATTENTION OF THE ENGINEER. THE CONTRACTOR IS <br />RESPONSIBLE FOR ALL REQUIRED DEMOLITION WHETHER <br />LEI30AR NON -FUSED DISCONNECT SWITCH, SIZE AS NOTED SHOWN ON THE PLANS OR NOT, <br />NF NF DENOTES NON -FUSED 4. ALL CONDUITS SERVING OTHER SPACES OR FLOORS, THAT <br />"AR FUSED DISCONNECT RUN THROUGH THE PROJECT AREA SHALL REMAIN ACTIVE <br />20AF DURING CONSTRUCTION, SO AS NOT TO CAUSE ANY <br />AR DENOTES AMP RATING OF SWITCH DISRUPTION TO THESE OTHER SPACES. IT IS THE <br />MCP AF DENOTES AMP FUSE SIZE CONTRACTOR'S RESPONSIBILITY TO INSURE THAT ALL <br />CONDUITS, NEW OR EXISTING, WITHIN THE PROJECT AREA <br />SIZE �# OF POLES ARE PROPERLY SUPPORTED AND PROVIDED WITH BONDING <br />L® 30/3 COMBINATION MAGNETIC MOTOR STARTER, BUSHING IN ACCORDANCE WITH THE NATIONAL ELECTRIC <br />0 3R SIZE AS NOTED, 3 POLE UNLESS OTHERWISE NOTED CODE. <br />5. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE <br />ENCLOSURE NEMA 1 UNLESS NOTED DISPOSED OR TURNED OVER TO THE OWNER AT THE <br />NEMA STARTER SIZE OWNER'S DISCRETION. <br />^ BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, 6. THIS CONTRACTOR SHALL PROVIDE ELECTRICAL FOR <br />SURFACE MOUNTED PHASING WORK AS REQUIRED OR DIRECTED BY THE <br />ARCHITECT, REFER TO ARCHITECURAL PHASING PLAN. <br />BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, TEMPORARY ELECTRICAL SERVICES (POWER, LIGHTING, <br />FLUSH MOUNTED NURSE CALL, FIRE ALARM, ETC) SHALL BE PROVIDED WHEN <br />NEW WORK AFFECTS SERVICES NEEDING TO REMAIN <br />® BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, ACTIVE. IF FIRE ALARM SYSTEM CANNOT BE MAINTAINED IN <br />SURFACE MOUNTED THE CONSTRUCITON AREA, A FIRE WATCH SHALL BE <br />PROVIDED. <br />T BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, 7, UNLESS OTHERWISE NOTED, ALL EQUIPMENT, WIRING <br />FLUSH MOUNTED DEVICES, LIGHT FIXTURES, CONDUIT AND WIRE IN THE <br />BRANCH CIRCUIT CONDUIT CONCEALED ABOVE PROJECT AREA SHALL BE REMOVED. THE CONTRACTOR <br />CEILING OR IN WALL. CONDUIT SHALL INCLUDE SHALL INVESTIGATE THE PROJECT AREA PRIOR TO BID TO <br />PHASE, NEUTRAL AND GROUND CONDUCTORS DETERMINE ALL REQUIRED DEMOLITION. <br />AS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED). 8, CONTRACTOR SHALL PROVIDE MEANS OF AUTOMATIC <br />BRANCH CIRCUIT CONDUIT CONCEALED IN SLAB, SMOKE DETECTION VIA INSTALLED SMOKE DETECTORS <br />--\ CONNECTED TO THE FACITLITY FIRE ALARMS SYSTEM FOR <br />UNDERGROUND OR UNDER FLOOR. COVERAGE DURING NON -OCCUPIED PERIODS WITHIN THE <br />CONSTRUCTION AREA, IF DESIRED, A DOCUMENTED FIRE <br />BRANCH CIRCUIT CONDUIT EXPOSED WATCH OF THE ENTIRE AREA PERFORMED IN INCREMENTS <br />NO GREATER THAN ONE HOUR MAY BE PERFORED <br />GROUND OR GROUND ROD AS NOTED PROVIDED THAT IT IS DOCUMENTED IN FULL ACCORDANCE <br />WITH NPFA 72. COORDINATE ACTIVITY IN FIELD WITH <br />C CRITICAL BRANCH CONDUIT GENERAL CONTRACTOR. <br />�- L LIFE SAFETY BRANCH CONDUIT 9. 'ETR" DENOTES EXISTING ELECTRICAL DEVICE TO REMAIN. <br />�EQ� EQUIPMENT BRANCH CONDUIT <br />NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. <br />GENERAL NOTES <br />FIXTURE) <br />TEM <br />C <br />1. LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE <br />FINISHED FLOOR TO CENTER LINE OF DEVICE, UNLESS <br />OTHERWISE NOTED. <br />2. RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE <br />FINISHED FLOOR TO CENTER LINE OF DEVICE, UNLESS <br />OTHERWISE NOTED. ABOVE COUNTER RECEPTACLES SHALL <br />BE MOUNTED T ABOVE BACK SPLASH TO CENTERLINE OF <br />DEVICE. <br />3. THE EQUIPMENT GROUNDING TERMINAL BARS OF THE <br />NORMAL AND ESSENTIAL ELECTRICAL SYSTEM <br />PANELBOARDS SERVING THE SAME PATIENT VICINITY SHALL <br />BE BONDED TOGETHER WITH AN INSULATED, CONTINUOUS, <br />COPPER CONDUCTOR NOT SMALLER THAN NUMBER 10. <br />4. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND <br />RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE <br />INSTALLED. <br />A. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT <br />SHALL BE IN COMPLIANCE WITH NEC 110. <br />B. THE EXCLUSIVELY DEDICATED SPACE EXTENDING FROM <br />FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH <br />OF THE PANELBOARD OR SWITCHBOARD MUST BE CLEAR OF <br />ALL PIPING, DUCTS, EQUIPMENT FOREIGN TO THE <br />ELECTRICAL EQUIPMENT OR ARCHITECTURAL <br />APPURTENANCES IN ACCORDANCE WITH NEC 408. <br />5. CRITICAL AND LIFE SAFETY LIGHT SWITCHES SHALL BE <br />ROUTED IN CONDUIT AND BOXES OTHER THAN THAT FOR <br />THE NORMAL BRANCH. ESSENTIAL SYSTEM SWITCHES <br />SHALL BE RED IN COLOR. <br />BRANCH. <br />6. PATIENT CARE AREAS SHALL BE PROVIDED WITH <br />GROUNDING IN ACCORDANCE WITH NEC 517. <br />7. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE - <br />RESISTIVE ASSEMBLIES, (CLASSIFIED AS FIRE/SMOKE AND <br />SMOKE PARTITIONS), THEY SHALL BE INSTALLED WITHOUT <br />AFFECTING THE FIRE CLASSIFICATION, ALL OF THE <br />FOLLOWING CONDITIONS SHALL BE MET: <br />A. ALL ELECTRICAL BOXES SHALL BE METALLIC. <br />B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF <br />FRAMING SPACE. <br />C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES. <br />D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM <br />BOARD SHALL BE COMPLETELY FILLED WITH JOINT <br />COMPOUND (OR OTHER APPROVED MATERIAL). <br />DEVICE <br />E. PROVIDE A WALL AROUND OUTLETS LARGER THAN 16 <br />SQUARE INCHES. THE INTEGRITY OF THE WALL RATING <br />SHALL BE MAINTAINED. <br />F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES <br />SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE <br />FEET. <br />G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE <br />RESISTIVE ASSEMBLIES SHALL BE SEPARATED BY A MINIMUM <br />HORIZONTAL DISTANCE OF 24 INCHES. <br />ES <br />H. OUTLET BOXES SHALL BE SECURELY FASTENED TO <br />WALL FRAMING MEMBERS. <br />I. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE <br />CUT NOT TO EXCEED 1/8 INCH BETWEEN THE EDGES OF THE <br />OUTLET BOX AND THE EDGES OF THE OPENING. <br />8. NON-METALLIC RACEWAYS SHALL NOT BE USED TO SERVE <br />ANY PATIENT CARE SPACE. ALL WIRING SHALL BE <br />MECHANICALLY PROTECTED BY INSTALLATION IN METALLIC <br />RACEWAYS, <br />9. ALL DEVICES SHALL BE MOUNTED VERTICAL, UNLESS <br />OTHERWISE NOTED. <br />10. ALL RECEPTACLES SHALL BE MOUNTED SUCH THAT THE <br />GROUND PIN IS MOUNTED UP, <br />11. THE NUMBER OF ARROWHEADS ON THE HOMERUNS <br />DENOTES THE NUMBER OF CIRCUITS. <br />12. ALL NEW AND EXISTING PANELS AFFECTED BY THIS PROJECT <br />SHALL BE PROVIDED WITH A NEW TYPE WRITTEN <br />DIRECTORY. <br />CODES <br />1. LIFE SAFETY CODE - NFPA 101(2015). <br />2. NATIONAL ELECTRICAL CODE - NFPA 70 (2014). <br />3. NATIONAL FIRE PROTECTION ASSOCIATION 72 (2013); NATIONAL FIRE ALARM & SIGNALING CODE. <br />4. NATIONAL FIRE PROTECTION ASSOCIATION 99 (2015). HEALTH CARE FACILITIES <br />5. BUILDING CODE: FLORIDA BUILDING CODE (2017 6TH EDITION). <br />6. FGI - GUIDELINES FOR DESIGN & CONSTRUCTION OF THE HEALTH CARE FACILITIES. (2014) <br />ELECTRICAL DRAWING INDEX <br />SHEET <br />DESCRIPTION <br />ISSUED <br />E001 <br />GENERAL INFORMATION - ELECTRICAL <br />Yes <br />E002 <br />ELECTRICAL ONE -LINE DIAGRAM <br />Yes <br />ED101 <br />LEVEL 1 DEMOLITION PLAN - PHASE 1 - POWER <br />Yes <br />ED102 <br />LEVEL 1 DEMOLITION PLAN - PHASE 2 - POWER <br />Yes <br />E101 <br />LEVEL 1 RENOVATION PLAN - PHASE 1 - POWER <br />Yes <br />E102 <br />LEVEL 1 RENOVATION PLAN - PHASE 2 - POWER <br />Yes <br />E201 <br />LEVEL 1 RENOVATION PLAN - PHASE 1 - LIGHTING <br />Yes <br />E202 <br />LEVEL 1 RENOVATION PLAN - PHASE 2 - LIGHTING <br />Yes <br />E301 <br />ELECTRICAL DETAILS <br />Yes <br />E401 <br />PANEL SCHEDULES <br />Yes <br />DIVISION 26 SPECIFICATIONS <br />1. THE WORK REQUIRED UNDER THIS DIVISION SHALL INCLUDE ALL MATERIALS, LABOR, TOOLS, EQUIPMENT, TRANSPORTATION, INSURANCE, <br />TEMPORARY PROTECTION, TEMPORARY LIGHTING, SUPERVISION AND INCIDENTAL ITEMS ESSENTIAL FOR PROPER INSTALLATION AND OPERATION, <br />EVEN THOUGH NOT SPECIFICALLY MENTIONED OR INDICATED BUT WHICH ARE USUALLY PROVIDED OR ARE ESSENTIAL FOR PROPER <br />INSTALLATION AND OPERATION OF ALL ELECTRICAL SYSTEMS THE ELECTRICAL SYSTEM REQUIRED UNDER THIS DIVISION CONSISTS BASICALLY <br />OF, BUT IS NOT LIMITED TO THE FOLLOWING: LIGHTING SYSTEM, POWER SYSTEM, ALARM SYSTEM, POWER DISTRIBUTION, EQUIPMENT <br />CONNECTIONS, ACCESS PANELS, EMPTY CONDUIT SYSTEMS AND ALL REQUIRED WIRING. <br />2. GIVE ALL NOTICES, FILE ALL PLANS, PAY ALL FEES, OBTAIN ALL PERMITS, ALL LICENSES, INSPECTIONS, RE -INSPECTIONS AND APPROVALS <br />FROM AUTHORITIES HAVING JURISDICTION. INCLUDE ALL FEES IN THE BID <br />3. A. SPECIAL ATTENTION IS CALLED TO THE FACT THAT WORK INVOLVED IS IN CONNECTION WITH EXISTING BUILDINGS WHICH REMAIN IN <br />OPERATION WHILE WORK IS BEING PERFORMED. WORK MUST BE DONE IN ACCORDANCE WITH THE PRIORITY SCHEDULE. SCHEDULE <br />WORK FOR A MINIMUM OUTAGE TO OWNER. CONTRACTOR SHALL CLOSELY COORDINATE WITH THE HOSPITAL PRIOR TO COMMENCING <br />WORK AND DURING CONSTRUCTION FOR POWER AND/OR SYSTEM OUTAGES AS WELL AS GENERAL REQUIREMENTS. RECEIVE WRITTEN <br />ACCEPTANCE FROM THE OWNER NO LATER THAN 7 DAYS IN ADVANCE OF ALL POWER OUTAGES. CONTRACTOR SHALL WORK DURING <br />OFF HOURS (EVENINGS & WEEKENDS) WHEN DEEMED NECESSARY BY THE HOSPITAL. PROTECT EXISTING BUILDINGS AND EQUIPMENT <br />DURING CONSTRUCTION. <br />B. CONTRACTOR SHALL VERIFY IF THERE IS ANY PIPING, FIXTURES OR OTHER ITEMS IN THE EXISTING BUILDING WHICH MUST BE REMOVED <br />OR RELOCATED IN ORDER TO PERFORM THE ALTERATION WORK. BID SHALL INCLUDE ALL REMOVAL AND RELOCATION REQUIRED FOR <br />COMPLETION OF THE ALTERATIONS AND THE NEW CONSTRUCTION. <br />C. ALL EXISTING/NEW CONDUIT AND CABLES WITHIN THE AREA OF RENOVATION SHALL BE PROVIDED WITH PROPER SUPPORTS. <br />D. ALL EXISTING ELECTRICAL WHICH IS DESIGNATED FOR REWORKING OR REQUIRES RELOCATION, REPAIR OR ADJUSTMENT SHALL CONFORM <br />TO ALL APPLICABLE CODES AND SHALL BE TREATED AS NEW WORK COMPLYING TO ALL PARTS OF THIS SPECIFICATION. <br />E. THE CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED PROGRAMMING FOR CONNECTION TO EXISTING SYSTEMS INCLUDING BUT NOT <br />LIMITED TO FIRE ALARM AND NURSE CALL. <br />4. ALL MATERIALS SHALL BE NEW AND FREE OF DEFECTS, AND SHALL BE U.L. LISTED, BEAR THE U.L. LABEL OR BE LABELED OR LISTED WITH <br />AN APPROVED, NATIONALLY RECOGNIZED ELECTRICAL TESTING AGENCY. WHERE NO LABELING OR LISTING SERVICE IS AVAILABLE FOR <br />CERTAIN TYPES OF EQUIPMENT, TEST DATA SHALL BE SUBMITTED TO PROVE TO THE ENGINEER THAT EQUIPMENT MEETS OR EXCEEDS <br />AVAILABLE STANDARDS. AFTER TEST DATA IS SUBMITTED AND TENTATIVELY APPROVED, THE CONTRACTOR SHALL PAY FOR ANY REQUIRED <br />FIELD LLISTING AND/OR CORRECTIVE WORK REQUIRED BY THE FIELD LISTING INSPECTOR IF ALLOWED BY THE AHJ. <br />5. PROVIDE SHOP DRAWING SUBMITTALS TO THE ARCHITECT/ENGINEER FOR APPROVAL FOR ALL MATERIAL PROVIDED UNDER THIS DIVISION, <br />EQUIPMENT SHALL NOT BE ORDERED PRIOR TO APPROVAL FROM THE ARCHITECT/ENGINEER. <br />6. COORDINATION STUDY: ALL PANELBOARD AND CIRCUIT BREAKERS SHALL MATCH THE EXISTING TYPE, AIC RATING, AND MANUFACTURER. ANY <br />DISCREPANCIES OR CONFLICTS IN THE SPECIFIED EQUIPMENT SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER DURING BID FOR <br />FORMAL CLARIFICATION. <br />7. PROVIDE AND INSTALL ALL ELECTRICAL SYSTEMS AND ANY NECESSARY ACCESSORIES AS PER NEC AND LOCAL CODES WHETHER SPECIFIED <br />HEREIN OR SHOWN ON DRAWINGS OR NOT. THE CONTENT OF THESE SPECIFICATIONS (DIVISION 26) AND CONTRACT DOCUMENTS IN GENERAL <br />ONLY REFERS TO WORK REQUIRED ABOVE AND BEYOND THE REQUIREMENTS OF THE NEC AND LOCAL CODES. <br />8. DRAWINGS ARE DIAGRAMMATIC. COORDINATE FINAL EQUIPMENT LOCATIONS WITH GOVERNING ARCHITECTURAL AND STRUCTURAL DRAWINGS. <br />LAY OUT BEFORE INSTALLATION SO THAT ALL TRADES MAY INSTALL EQUIPMENT IN SPACES AVAILABLE. PROVIDE COORDINATION AS <br />REQUIRED FOR INSTALLATION IN A NEAT AND WORKMANLIKE MANNER. <br />9. CHECK SITE AND EXISTING CONDITIONS THOROUGHLY BEFORE BIDDING. ADVISE ENGINEER OF DISCREPANCIES OR QUESTIONS NOTED. WHERE <br />EXISTING CONDITIONS ARE DISCOVERED WHICH ARE NOT IN COMPLIANCE WITH THE CODES AND STANDARDS, THE CONTRACTOR SHALL <br />SUBMIT PROPERDOCUMENTATION TO THE ARCHITECT FOR CLARIFICATION AND CORRECTIVE WORK DIRECTION. EXISTING <br />CONDITIONS SHALL NOT REMAIN WHICH WILL CREATE A DISAPPROVAL OF THE RENOVATED AREA. <br />10. ALL EXISTING CONDUIT AND CABLE PENETRATIONS SHALL BE PROPERLY FIRE TREATED PER CODE AND SPECIFICATION REQUIREMENTS. THE <br />CONTRACTOR SHALL THOROUGHLY INSPECT ALL EXISTING LOCATIONS AND INCLUDE THE COST OF PATCHING AND REPAIR IN HIS PROPOSED <br />CONSTRUCTION COST. <br />11. PROVIDE FIELD SUPERINTENDENT WHO HAS HAD A MINIMUM OF FOUR (4) YEARS PREVIOUS SUCCESSFUL EXPERIENCE ON PROJECTS OF <br />COMPARABLE SIZES AND COMPLEXITY. SUPERINTENDENT SHALL BE PRESENT AT ALL TIMES THAT WORK UNDER THIS DIVISION IS BEING <br />INSTALLED OR AFFECTED. SUPERINTENDENT SHALL HAVE PASSED A PROCTORED H.H. BLOCK JOURNEYMAN EXAM WITH 75% GRADE OR <br />BETTER AND SHALL BE A LICENSED JOURNEYMAN. A RESUME OF THE SUPERINTENDENT'S EXPERIENCE SHALL BE SUBMITTED TO ENGINEER <br />BEFORE STARTING WORK. AT LEAST ONE MEMBER OF THE ELECTRICAL CONTRACTING FIRM SHALL HOLD A STATE MASTER CERTIFICATE OF <br />COMPETENCY. <br />12. PROVIDE ALL REQUIRED COORDINATION AND SUPERVISION WHERE WORK CONNECTS TO OR IS AFFECTED BY WORK OF OTHERS, AND COMPLY <br />WITH ALL REQUIREMENTS AFFECTING THIS DIVISION. <br />13. SUITABLY PROTECT ALL EQUIPMENT FURNISHED UNDER THIS DIVISION DURING CONSTRUCTION. RESTORE ALL DAMAGED SURFACES AND <br />ITEMS TO "LIKE NEW" CONDITION BEFORE A REQUEST FOR SUBSTANTIAL COMPLETION INSPECTION. <br />14. THE WORK REQUIRED UNDER THIS DIVISION SHALL INCLUDE A ONE-YEAR GUARANTEE. THIS GUARANTEE SHALL BE BY THE CONTRACTOR TO <br />THE OWNER FOR ANY DEFECTIVE WORKMANSHIP OR MATERIAL WHICH HAS BEEN FURNISHED UNDER THIS CONTRACT AT NO COST TO THE <br />OWNER FOR A PERIOD OF ONE YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION OF THE SYSTEM. THIS GUARANTEE SHALL NOT <br />INCLUDE LAMPS IN SERVICE. THE PROVISIONS OF GUARANTEE TO THE OWNER AT THE "DEMONSTRATION OF COMPLETED AFTER ONE MONTH <br />FROM DATE OF SUBSTANTIAL COMPLETION OF THE SYSTEM." <br />15. PERFORM VERIFICATION WORK AS REQUIRED TO SHOW THAT THE SYSTEM IS OPERATING CORRECTLY IN ACCORDANCE WITH CONTRACT <br />DOCUMENTS AND MANUFACTURER'S LITERATURE. ALL VERIFICATION SHALL BE DONE AFTER 3-DAY FULL OPERATIONAL PERIOD. ALL WORK <br />ON THE SYSTEM SHALL BE COMPLETED, AND ALL FORMS AND OTHER INFORMATION SHALL BE SUBMITTED FOR APPROVAL ONE WEEK <br />BEFORE THE REQUEST FOR FINAL INSPECTION OF THE BUILDING. <br />16. WHERE THE REQUIREMENTS OF ANOTHER DIVISION, SECTION, OR PART OF THESE SPECIFICATIONS EXCEED THE REQUIREMENTS OF THIS <br />DIVISION, THOSE REQUIREMENTS SHALL GOVERN. <br />17. THE ENTIRE INSTALLATION SHALL BE IN HOT DIPPED RIGID GALVANIZED CONDUIT, OR ELECTRIC METALLIC TUBING, UNLESS SPECIFICALLY <br />NOTED OTHERWISE. RIGID METAL GALVANIZED CONDUIT SHALL BE USED IN ALL DAMP OR WET LOCATIONS OR WHERE SUBJECT TO <br />MECHANICAL DAMAGE. ELECTRIC METALLIC TUBING SHALL HAVE STEEL COMPRESSION TYPE COUPLINGS AND BE USED INSIDE OF BUILDINGS <br />AND ONLY IN DRY AREAS WHERE NOT EXPOSED TO MECHANICAL DAMAGE. MINIMUM CONDUIT SIZE FOR ALL SYSTEMS SHALL BE 3/411 <br />. <br />PROVIDE INSULATED BUSHINGS AT ENDS OF ALL CONDUITS. ALL CONDUITS AND BACKBOXES SHALL BE COLOR CODED TO MATCH EXISTING <br />HOSPITAL STANDARDS. SUPPORT CONDUIT IN ACCORDANCE WITH THE NEC. LISTED WHIPS FOR LIGHTING FIXTURES SHALL BE ALLOWED NO <br />LONGER THAN 6-0" IN LENGTH, <br />18. BRANCH CIRCUIT AND FEEDER CONDUCTORS FOR ELECTRIC POWER SHALL BE COPPER TYPE THHN/THWN INSULATION FOR BRANCH <br />CIRCUITS AND THWN INSULATION FOR FEEDERS, UNLESS SPECIFICALLY NOTED OTHERWISE. SIZES #12 AND SMALLER SHALL BE SOLID, #10 <br />AND LARGER STRANDED. NO ALUMINUM WIRING SHALL BE PERMITTED. ALL WIRE SHALL BE SIZE SHOWN ON THE DRAWINGS. IF NO SIZE IS <br />SHOWN, WIRE SHALL BE MINIMUM NO. 12, EXCEPT THAT BRANCH "HOMERUNS" OVER 50 FT. IN LENGTH SHALL BE MINIMUM NO. 10. WIRE IN <br />VICINITY OF HEAT -PRODUCING EQUIPMENT SHALL BE TYPE XHHW INSULATION. ALL WIRING SHALL BE MANUFACTURED IN THE USA. WIRING <br />SHALL BE COLOR CODED ACCORDING TO EXISTING HOSPITAL STANDARDS. USE OF MULTI -WIRE BRANCH CIRCUIT CONFIGURATIONS ARE NOT <br />PERMITTED. ALL BRANCH CIRCUITS SPECIFIED SHALL BE PROVIDED WITH A DEDICATED NEUTRAL CONDUCTOR EACH SIZED TO MATCH THE <br />CORRESPONDING PHASE CONDUCTORS FOR THE BRANCH CIRCUIT. <br />19. EACH THREE-PHASE CIRCUIT SHALL BE RUN IN A SEPARATE CONDUIT UNLESS OTHERWISE SHOWN ON THE DRAWINGS. CONDUIT SHALL <br />NOT BE INSTALLED EXPOSED UNLESS OTHERWISE NOTED. WHERE CIRCUITS ARE SHOWN AS "HOME -RUNS" ALL NECESSARY FITTINGS AND <br />BOXES SHALL BE PROVIDED FOR A COMPLETE RACEWAY INSTALLATION. NEUTRAL CONDUCTORS SHALL NOT BE SHARED BETWEEN CIRCTUITS <br />AND THEREFORE ALL CIRCUITS REQUIRING A NEUTRAL CONDUCTOR SHALL EACH RECIEVE A DEDICATED NEUTRAL SIZED TO MATCH THE <br />CORRESPONDING PHASE CONDUCTORS. <br />20. OUTLET BOXES SHALL BE ONE PIECE OR PROJECTION WELDED, GALVANIZED STAMPED STEEL FOR GANG SIZES REQUIRED. SECTIONAL <br />BOXES ARE NOT ACCEPTABLE. BOXES SHALL BE 4" SQUARE AND 1-1/2" DEEP GENERALLY, LARGER BOXES SHALL BE USED AS <br />REQUIRED BY CODE. <br />21. ALL RECEPTACLES SHALL BE 20 AMP HOSPITAL GRADE, STANDARD DUPLEX GROUNDING TYPE. SWITCHES SHALL BE SPECIFICATION GRADE, <br />20 AMP,120/277 VOLT AND SHALL BE OF THE SILENT OPERATING TYPE. GFCI RECEPTACLES SHALL BE HOSPITAL GRADE, UL RATED CLASS <br />A, GROUP 1. COVER PLATES SHALL BE STAINLESS STEEL FINISHED. ALL WIRING DEVICE COVER PLATES INCLUDING BUT NOT LIMITED TO <br />RECEPTACLES AND SWITCHES SHALL BE ENGRAVED WITH THE BRANCH CIRCUIT IDENTIFICATION AS REQUIRED (I.E. "PANELNAME'-"CIRCUIT <br />NUMBER"). COVERPLATES SHALL BE STAINLESS STEEL WITH BLACK INFILLED LETTERS FOR NORMAL BRANCH AND RED INF►LLED LETTERS <br />FOR EMERGENCY BRANCHES. RECEPTACLES AND SWITCHES SHALL HAVE IVORY FINISH FOR NORMAL BRANCH DEVICES AND RED FINISH FOR <br />CRITICAL BRANCH DEVICES. APPROVED MANUFACTURER: PASS & SEYMOUR, LEVITON, HUBBELL <br />22. ALL EQUIPMENT SHALL BE FIRMLY MOUNTED USING APPROVED HANGERS ATTACHED TO STRUCTURAL PORTIONS OF THE BUILDING. <br />SUPPORTING WITH TIE WIRE IS PROHIBITED. LIGHT FIXTURES RECESSED IN CEILINGS SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE <br />INDEPENDENT OF THE CEILING SYSTEM. <br />23. IN GENERAL, ALL ELECTRICAL EQUIPMENT (METALLIC CONDUIT, MOTOR FRAMES, PANELBOARDS, ETC.) SHALL BE BONDED TOGETHER WITH A <br />GREEN INSULATED COPPER SYSTEM GROUNDING CONDUCTOR IN ACCORDANCE WITH SPECIFIC RULES OF ARTICLE 250 OF THE N.E.C. <br />BONDING CONDUCTOR THROUGH THE RACEWAY SYSTEM SHALL BE CONTINUOUS FROM EACH WIRING DEVICE OR EQUIPMENT TO PANEL <br />GROUND BAR OF EACH PANELBOARD. PROVIDE GROUND BAR BOLTED TO THE CAN OF EXISTING PANELS WITHOUT A GROUND BAR. ALL <br />RACEWAYS SHALL HAVE AN INSULATED COPPER SYSTEM GROUND CONDUCTOR THROUGHOUT THE ENTIRE LENGTH OF CIRCUIT INSTALLED <br />WITHIN CONDUIT PER NEC 517.13. GROUNDING CONDUCTOR SHALL BE INCLUDED IN TOTAL FILL IN DETERMINING CONDUIT SIZES, EVEN <br />THOUGH NOT INCLUDED OR SHOWN ON DRAWINGS. <br />24. A. MOLDED CASE CIRCUIT BREAKERS: ALL PANELBOARD BRANCH CIRCUIT BREAKERS SHALL BE BOLT -ON THERMAL -MAGNETIC MOLDED <br />CASE TYPE. BREAKERS SHALL BE 1, 2 OR 3 POLE WITH AN INTEGRAL CROSSBAR TO ASSURE SIMULTANEOUS OPENING OF ALL POLES IN <br />MULTI -POLE CIRCUIT BREAKERS. BREAKERS SHALL HAVE AN OVERCENTER,TRIP-FREE,TOGGLE-TYPE OPERATING MECHANISM WITH QUICK - <br />MAKE, QUICK -BREAK ACTION AND ACTIVE HANDLE INDICATION. HANDLES SHALL HAVE "ON", "OFF", AND "TRIPPED" POSITIONS. BOLT -ON <br />BREAKER SHALL BE ABLE TO BE INSTALLED IN THE PANELBOARD WITHOUT REQUIRING ADDITIONAL MOUNTING HARDWARE. <br />CIRCUIT S Q <br />120/208 VOLT CIRCUIT BREAKERS SHALL HAVE INTERRUPTING RATINGS A MINIMUM OF 10,000 RIMS SYMMETRICAL AMPERES AT 240VAC. <br />277/480 VOLT CIRCUIT BREAKERS SHALL HAVE INTERRUPTING RATINGS A MINIMUM OF 18,000 RMS SYMMETRICAL AMPERES AT 600VAC. <br />25. RECORD DRAWINGSAT THE COMPLETION OF WORK, CONTRACTOR SHALL PROVIDE TWO SETS OF RECORD "AS -BUILT" DRAWINGS IN <br />ACCORDANCE WITH DIVISION 1, SHOWING THE ACTUAL LOCATION OF ALL EQUIPMENT INSTALLED INCLUDING UNDERGROUND CONDUITS AND <br />JUNCTION BOXES. <br />26. CONTRACTOR SHALL CLOSELY COORDINATE WITH THE HOSPITAL PRIOR TO COMMENCING WORK AND DURING CONSTRUCTION FOR POWER <br />AND/OR SYSTEM OUTAGES AS WELL AS GENERAL REQUIREMENTS. A SEVEN (7) DAY NOTICE SHALL BE GIVEN FOR ALL POWER OUTAGES. <br />CONTRACTOR SHALL WORK DURING OFF HOURS (EVENINGS & WEEKENDS) WHEN DEEMED NECESSARY BY THE HOSPITAL. <br />27. GROUND TESTINGCONTRACTOR SHALL PERFORM A COMPLETE EQUIPOTENTIAL GROUND TEST IN ACCORDANCE WITH NFPA 99 UPON THE <br />COMPLETION OF ALL BRANCH CIRCUITS TO THE PANELS SPECIFIED. GROUND TEST SHALL BE IN A TYPED WRITTEN FORMAT FOR ISSUANCE <br />TO AHCA AT THE 100% INSPECTION. TEST SHALL BE PERFORMED IN ALL AFFECTED PATIENT -CARE AREAS. <br />28. COLOR CODING COLOR CODE ALL POWER AND LIGHTING CABLE. COLOR CODE THE WIRE BY USING COLORED PLASTIC TAPE, PAINTING THE <br />ENDS ACCESSIBLE AT JUNCTION OR PULL BOXES, OR OTHER METHOD ACCEPTABLE TO THE ENGINEER. USE THE FOLLOWING CHART AS <br />APPLICABLE; <br />120/208 277/480 <br />CONDUCTOR VOLTS CONDUCTOR VOLTS <br />PHASE A BLACK PHASE A BROWN <br />PHASE B RED PHASE B ORANGE <br />PHASE C BLUE PHASE C YELLOW <br />NEUTRAL WHITE NEUTRAL GRAY <br />EQUIRGROUND GREEN EQUIRGROUND GREEN <br />29. COLOR CODING OF RACEWAYS/BOXES: ALL BOXES AND ENCLOSURES SHALL BE MARKED SO AS TO BE READILY IDENTIFIED AS PART OF THE <br />SYSTEM FOR WITH IT SERVES. CONDUIT AND BOXES, INCLUDING BACK BOXES. PANELS, ETC. SHALL BE SPOT PAINTED. CONDUITS SHALL BE <br />IDENTIFIED TO WITHIN 6" OF THE BOX OR ENCLOSURE. PROVIDE SPOT PAINTING BANDS AT ALL CONDUIT COUPLING LOCATIONS OR EVERY 1 U-0" <br />WHICHEVER IS LESS ALONG WITHIN 6" OF EACH SIDE OF WALLS AND FLOOR THAT THE CONDUIT PENETRATES. THE FOLLOWING COLOR CODES <br />SHALL BE USED UNLESS OTHERWISE REQUIRED TO MATCH EXISTING COLOR CODING; <br />BLACK: NORMAL BROWN: MISCELLANEOUS COMMUNICATIONS <br />PURPLE: ESSENTIAL DISTRIBUTION BLUE: TELEPHONEICOMPUTER <br />YELLOW: LIFE SAFETY BRANCH WHITE: NURSE CALL <br />ORANGE: CRITICAL BRANCH LIGHT PINK: TV <br />GREEN: EQUIPMENT BRANCH GREY: PAGING <br />RED: FIRE ALARM BRANCH BEIGE: PHYSIOLOGICAL MONITORING <br />30. EQUIPMENT IDENTIFICATION: <br />LOCATIONS: PROVIDE NAMEPLATES FOR EACH UNIT OF THE FOLLOWING CATEGORIES OF ELECTRICAL WORK: <br />A. SWITCHBOARD, PANELBOARDS, ELECTRICAL CABINETS AND ENCLOSURES. <br />(1) PROVIDE A NAMEPLATE OUTSIDE ABOVE THE DOOR (IF EQUIPPED WITH ONE) LISTING ITS <br />DESIGNATION, BRANCH, VOLTAGE AND CIRCUIT NUMBER. <br />(2) PROVIDE AN ENGRAVED PHENOLIC PLASTIC LAMINATE NAMEPLATE: <br />(NORMAL BRANCH: BLACK W/WHITE LETTTERS) <br />(CRITICAL BRANCH: ORANGE W/WHITE LETTTERS) <br />(EQUIPMENT BRANCH: GREEN W/WHITE LETTTERS) <br />(LIFE SAFETY BRANCH: YELLOW W/WHITE LETTTERS) <br />(3) NAMEPLATE SIZE SHALL MATCH EXISTING. <br />B. ACCESS PANEUDOORS TO ELECTRICAL FACILITIES. <br />C. MOTOR STARTERS. <br />D. ALL WIRING DEVICE'S COVERPLATES INCLUDING BUT NOT LIMITED TO RECEPTACLES AND <br />SWITCHES SHALL BE REPLACED WITH NEW 302 STAINLESS STEEL COVERPLATES, AND ENGRAVED <br />IN BLACK FOR NORMAL AND RED FOR EMERGENCY BRANCHES WITH THE BRANCH CIRCUIT <br />IDENTIFICATIONS AS REQUIRED (I.E. "PANELNAME" - CIRCUIT NUMBER"). <br />E. ALL EXIT LIGHTS TO HAVE LABELS MADE (WHITE WIRED LETTERS) AND INSTALLED ON CANOPY <br />OF FIXTURE WITH PANELNAME - CIRCUIT NUMBER. <br />F. ALL AUTOMATIC DOOR CONTROLLERS TO HAVE LABELS MADE (WHITE WIRED LETTERS) AND <br />INSTALLED BY DOOR CONTROL ENCLOSURE (LOCATED BELOW THE CEILING) WITH <br />PANELNAME - CIRCUIT NUMBER. <br />1715 N. Westshore Blvd., Suite 600 <br />Tampa„ Florida 33607-3999 <br />904-256-2500 Fax 904-256-2503 <br />www.rsandh.com <br />FL Cerl. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * GB238 <br />,&:-TLC <br />ENGINEERING <br />S© L U T I 0 N S® <br />255 S. Orange Avenue <br />Suite 1600 <br />Orlando, FL 32801 <br />P 407.841.9050 <br />www.tic-engineers.com <br />COA 15 <br />C Copyright 2019 TLC Engineering Solutions, Inc. <br />TLC Project No.: 119333 <br />THINK. LISTEN. CREATE. <br />PROJECT TITLE: <br />KITCHEN RENOVATION <br />ADVENTHEALTH ZEPHYRHILLS <br />PROJECT ADDRESS: <br />7050 Gall Blvd. Zephyrhills, FL 33541 <br />Christopher V. O'Hara, P.E. <br />Florida License #66504 <br />�69H Eq IO,���i <br />5 <br />i <br />V' No 66504 <br />C14 <br />.-:13 �' STATE OF U m <br />DN � 0 'rit CkS//TOPHER V OHAR� • • 441 O <br />OID.O. 4 OOJp0900 .. =¢Q1 Ip;A110001 `y'y��� f000088F5. <br />CN=CHiM1�F�„ QV=GE't�iil f®I�R <br />ARCHITEjG ING I'RC CTURE, C=US <br />Date: 20- 0 I 0 'N A\_ % M <br />1�111111111��`, N <br />w <br />G <br />O <br />c,) <br />z <br />LU <br />J <br />U <br />Q <br />U <br />x <br />Q <br />REVISIONS <br />NO. DESCRIPTION DATE <br />DATE ISSUED: 03/20/20 <br />REVIEWED BY: CVO <br />DRAWN BY: MA <br />DESIGNED BY: MA <br />PROJECT NUMBER: <br />504- 0226- 000 <br />0 2019 RS&H, INC. <br />SHEET TITLE: <br />GENERAL <br />INFORMATION - <br />ELECTRICAL <br />SHEET ID: <br />E001 <br />I PROJECT STATUS: I <br />CONSTRUCTION DOCUMENTS <br />Copyright 0 2018. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved, <br />2 <br />3 <br />4 <br />5 <br />