Laserfiche WebLink
L " i -A I I I __ L I _ Id 1 L. - - __ - - 1 1 _ - I - 9 LI Ti I'll I I 1 I I R <br />1 2 3 4 I 5 <br />TECHNOLOGY SYSTEMS SYMBOL LEGEND <br />RS&H <br />M <br />A <br />a <br />CM <br />1P <br />Cl) <br />0 <br />0 <br />N <br />N <br />co <br />BASIC MATERIALS <br />SYMBOL DESCRIPTION <br />OJ JUNCTION BOX <br />�J FLOOR MOUNTED JUNCTION BOX <br />PEDESTAL MOUNTED JUNCTION BOX <br />EXISTING CONDUIT ABOVE HARD CEILING <br />_ <br />BETWEEN CEILING BOXES <br />CONDUIT CONCEALED ABOVE CEILING OR IN WALL <br />CONDUIT CONCEALED IN SLAB, UNDERGROUND OR <br />_ <br />UNDER <br />FLOOR <br />- - - - - - <br />CONDUIT EXPOSED <br />-Q <br />CONDUIT TURNING UP <br />-� <br />CONDUIT TURNING DOWN <br />CONDUIT STUB <br />CONDUIT CONTINUED <br />FLEXIBLE CONDUIT <br />I <br />GROUND OR GROUND ROD AS NOTED <br />O <br />SLEEVE TURNING UP <br />SLEEVE TURNING DOWN <br />_ _ _ _ _ <br />EXISTING TO BE REMOVED <br />EXISTING TO REMAIN <br />EXISTING AFFECTED BY THIS PROJECT <br />__________ <br />FUTURE <br />NEW <br />COMMUNICATIONS CABLE TRAY FOR HORIZONTAL <br />CABLING. DIMENSIONS SHOWN ON DRAWINGS. <br />E 3 <br />RATED WALL PENETRATION SEE FLOOR PLAN AND <br />DETAILS FOR QUANTITY AND TYPE. <br />SECURITY SYSTEM <br />SYMBOL DESCRIPTION <br />FIX <br />FIXED CCTV CAMERA <br />DPS <br />DOOR POSITION SWITCH <br />CR <br />CARD READER <br />CK <br />COMBINED CARD READER/KEYPAD <br />KP <br />KEYPAD <br />EL <br />ELECTRIC LATCH. <br />EM <br />ELECTRIC MORTISE LOCK <br />ES <br />ELECTRIC STRIKE. <br />ML <br />MAGNETIC LOCK <br />DE <br />DELAYED EGRESS <br />DM <br />DELAYED EGRESS MAGNETIC LOCK <br />DOOR RELEASE BUTTON <br />a <br />REX OR ADA DOOR OPEN BUTTON <br />I� <br />DURESS BUTTON <br />IS <br />INTERCOM SUBSTATION WITH CAMERA <br />MASTER INTERCOM STATION W/ LCD MONITOR & <br />MI <br />REMOTE DOOR RELEASE BUTTONS <br />0 <br />REQUEST TO EXIT MOTION SENSOR <br />OASSOCIATED <br />DOOR DETAIL REFERENCE <br />MON <br />CCTV MONITOR <br />VOICE & DATA SYSTEM <br />SYMBOL DESCRIPTION <br />1 � , <br />C X N <br />44 W <br />F1 <br />S1 <br />ELV <br />S1 <br />WAP <br />MOUNTING 2" ABOVE COUNTER OR BACK SPLASH <br />X = MOUNTING (F)LUSH, (S)URFACE, (M)ODULAR FURNITURE ADAPTER <br />(P)OLE, (R)ACEWAY, (D)OUBLE GANG FLUSH, (PD) PEDESTAL, (H)EADWALL <br />N=#OF CAT6 JACKS <br />COMMUNICATIONS "INFORMATION OUTLET" MOUNTED AT <br />RECEPTACLE HEIGHT UNLESS OTHERWISE NOTED, MODULE <br />AND FACEPLATE DESCRIPTIONS, SEE DETAIL SHEETS. <br />WALL TELEPHONE OUTLET. MOUNTED AT 52" ABOVE FINISHED <br />FLOOR TO THE BOTTOM OF THE BOX. SEE DETAIL SHEETS. <br />WALL TELEPHONE OUTLET FOR TELEPHONE ELEVATOR MACHINE <br />ROOM. (S)URFACE MOUNTED AT 52" ABOVE FINISHED FLOOR. <br />WIRELESS ACCESS POINT OUTLET. SEE DETAIL SHEETS FOR <br />MOUNTING DETAILS. QUANTITY AND LOCATIONS ARE APPROXIMATE, <br />CONTRACTOR TO COORDINATE WITH WLAN VENDOR ACTUAL <br />QUANTITY AND LOCATIONS BASED ON SIGNAL SURVEY. SIGNAL <br />SURVEY BY WLAN VENDOR. <br />BISCUIT JACK OUTLET MOUNTED ABOVE CEILING. <br />APPROXIMATE LOCATION OF CORNING ONE DAS ANTENNA, + 2 FEET <br />ANTENNA IS OWNER PROVIDED, STRUCTURED CABLING <br />CONTRACTOR INSTALLED. <br />APPROXIMATE LOCATION OF PUBLIC SAFETY LEGACY DAS ANTENNA, <br />+ 2 FEET, ANTENNA IS OWNER PROVIDED, STRUCTURED CABLING <br />CONTRACTOR INSTALLED. <br />COMBINED VOICE/DATA/POWER OUTLET IN POKE-THRU. <br />CONDUIT, POKE-THRU AND POWER RECEPTACLE PROVIDED BY <br />DIV. 16. "N" IS THE NUMBER OF CAT 6 JACKS. <br />COMBINED VOICE/DATA/AUDIONISUAL/POWER OUTLET IN POKE- <br />THRU. CONDUIT, POKE-THRU AND POWER <br />RECEPTACLE PROVIDED BY DIV. 16. N IS THE NUMBER <br />OF CAT 6 JACKS, SEE AV DETAILS FOR AV CONNECTION <br />REQUIREMENTS. <br />TELEVISION OUTLET - FLUSH MOUNTED. (1) COAX RG-6 AND (1) <br />CAT6 UTP CABLE TO TELECOMM ROOM. ADJACENT DUPLEX <br />RECEPTACLE BY ELECTRICAL CONTRACTOR. COORDINATE <br />MOUNTING LOCATION WITH ARCHITECTURAL. <br />TELEVISION OUTLET - CEILING MOUNTED. (1) COAX RG-6 AND (1) <br />CAT6 UTP CABLE TO TELECOMM ROOM. ADJACENT DUPLEX <br />RECEPTACLE BY ELECTRICAL CONTRACTOR. COORDINATE <br />MOUNTING LOCATION WITH ARCHITECTURAL. <br />3/4" PLYWOOD BACKBOARD. BY DIVISION 16 <br />F -1 T -19" EQUIPMENT RACK <br />L_ T <br />TELECOMM PANEL <br />NOTES: <br />1. CONTRACTOR TO REMOVE ALL EXISTING LOW VOLTAGE CABLES NOT TO BE REUSED. E.G. ALL <br />EXISTING UTP 4 PAIR CABLES. NO ABANDONED CABLES SHALL BE LEFT IN THE PROJECT AREA <br />2. OUTLET QUANTITY AND CONFIGURATION SHALL BE PER THESE DRAWINGS. FOR LOCATION <br />RELATIVE TO CASE WORK AND EQUIPMENT REFER TO ARCHITECTURAL ELEVATIONS. <br />3. WIRE ACCESS POINTS (WAP) SHALL BE PROVIDED BY THE OWNER AND INSTALLED BY THE <br />STRUCTURED CABLING CONTRACTOR. <br />PAGING AND BACKGROUND MUSIC SYSTEM <br />OCEILING MOUNTED SPEAKER - <br />X-Y X-Y: X DENOTES FLOOR <br />Y DENOTES SUBZONE <br />WALL MOUNTED SPEAKER - <br />X-Y X-Y: X DENOTES FLOOR <br />Y DENOTES SUBZONE <br />VC CEILING SPEAKER VOLUME CONTROL <br />NOTES: <br />1. AUDIO/VISUAL DEVICES AND EQUIPMENT ARE SHOWN FOR <br />REFERENCE ONLY AND WILL BE PROVIDED BY THE OWNER. <br />2. THE RACEWAY SYSTEMS NOTED FOR THE AV EQUIPMENT <br />INSTALLATION SHALL BE PROVIDED BY THE ELECTRICAL <br />CONTRACTOR AND INSTALLED PER DIVISION 27 SPECIFICATIONS. <br />3. SPEAKERS AND CABLING SHALL BE PROVIDED BY THE <br />STRUCTURED CABLING CONTRACTOR. <br />NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. <br />TECHNOLOGY NOTES <br />1. PRODUCTS SHALL BE OF MATERIALS THAT ARE SUITABLE FOR THE ENVIRONMENT IN WHICH THEY <br />ARE TO BE INSTALLED. <br />2. WORKING CLEARANCES AROUND ELECTRICAL EQUIPMENT SHALL BE MAINTAINED IN COMPLIANCE <br />WITH THE NATIONAL ELECTRICAL CODE ARTICLE 110, COORDINATE EQUIPMENT INSTALLATION TO <br />MAINTAIN REQUIRED CLEARANCES. <br />3. IF AN OUTLET BOX IS REQUIRED TO BE LOCATED IN AN ASSEMBLY OR PARTITION RATED AS <br />"FIRE/SMOKE" OR "SMOKE" OR IDENTIFIED AS EITHER "FIRE/SMOKE" OR "SMOKE", THEN ALL OF THE <br />FOLLOWING CONDITIONS SHALL BE MET: <br />A. THE OUTLET BOX SHALL BE METALLIC. <br />B. THE OUTLET BOX OPENINGS SHALL OCCUR ONLY ON ONE SIDE OF THE FRAMING SPACE. <br />C. THE OUTLET BOX OPENINGS SHALL NOT EXCEED 16 SQUARE INCHES. <br />D. ALL CLEARANCES BETWEEN THE OUTLET BOX AND THE WALL BOARD <br />MATERIAL SHALL BE COMPLETELY SEALED WITH APPROVED MATERIALS IN <br />ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS FOR THE <br />PROJECT. <br />E. PROVIDE A SUPPLEMENTAL BARRIER AROUND OUTLETS LARGER THAN 16 <br />INCHES SO THAT THE ORIGINAL RATING OF THE PENETRATION IS MAINTAINED. <br />F. THE TOTAL AGGREGATE SURFACE AREA OF THE OUTLET BOX SHALL NOT <br />EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET. <br />G. THE OUTLET BOX SHALL BE SEPARATED FROM OPENINGS ON THE OPPOSITE SIDE <br />OF THE RATED PARTITION BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. <br />H. THE OUTLET BOX SHALL BE SECURELY FASTENED TO A PARTITION FRAMING <br />MEMBER BY MEANS OF AN APPROVED ATTACHMENT METHOD. <br />I. OPENINGS CUT INTO THE WALL BOARD MATERIAL SHALL NOT EXCEED 1/8 INCH <br />BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE OPENING. <br />4. LOCATION OF EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE, COORDINATE EXACT <br />EQUIPMENT LOCATION AND CONNECTION REQUIREMENTS WITH THE APPROPRIATE TRADE PRIOR TO <br />INSTALLATION. <br />5. FOR EXACT LOCATION OF CEILING MOUNTED EQUIPMENT REFER TO THE ARCHITECTURAL <br />REFLECTED CEILING PLAN. LOCATIONS OF EQUIPMENT NOT INCLUDED ON THE REFLECTED CEILING <br />PLAN SHALL BE COORDINATED WITH THOSE ITEMS SHOWN. COORDINATION OF CEILING MOUNTED <br />EQUIPMENT SHALL BE PRIOR TO ANY ROUGH -IN. NOTIFY ENGINEER OF ANY DISCREPANCY. <br />6. PROVIDE FINAL CONNECTIONS TO OWNER -PROVIDED EQUIPMENT WHERE INDICATED ON THE PLAN <br />DRAWINGS <br />7. PRIOR TO ROUGH -IN AND INSTALLATION OF ANY FLOOR -MOUNTED DEVICE, VERIFY LOCATION WITH <br />THE OWNER AND ARCHITECT. <br />8. VERIFY AND COORDINATE THE LOCATION OF REQUIRED DIVISION 27 OUTLETS WITH OTHER TRADE <br />DRAWINGS AND OWNER PROVIDED EQUIPMENT. VOICE/DATA OUTLETS SHALL BE ADJACENT TO AN <br />ELECTRICAL OUTLET. <br />9. EACH TELEVISION OUTLET LOCATION SHOWN, SHALL HAVE A DOUBLE GANG OUTLET BOX WITH A <br />SINGLE GANG PLASTER RING AND (1) ONE INCH CONDUIT STUBBED UP TO AN ACCESSIBLE LOCATION <br />ABOVE THE FINISHED CEILING OR TO AN ACCESSIBLE CABLE TRAY WHERE PROVIDED. WORK BY <br />ELECTRICAL CONTRACTOR (DIV. 26) SHALL BE AS PER SPECIFICATION SECTION 270528. <br />10. THE DESIGNATION "N.►.C." SHALL DENOTE ITEMS, WHICH ARE "NOT IN CONTRACT". <br />11. THE DESIGNATION "U.S.C." SHALL DENOTE ITEMS, WHICH ARE "UNDER SEPARATE CONTRACT'. <br />12. THE DESIGNATION "F.B.O." SHALL DENOTE ITEMS, WHICH ARE "FURNISHED BY OTHERS". <br />13. THE DESIGNATION "O.F.E." SHALL DENOTE ITEMS, WHICH ARE "OWNER FURNISHED EQUIPMENT'. <br />14. ALL RACEWAY SYSTEMS SHOWN TO SUPPORT THE INSTALLATION OF THE DIVISION 27 EQUIPMENT <br />SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. PROVIDE COORDINATION FOR THE <br />INSTALLATION OF THIS RACEWAY SYSTEM WITH THE ELECTRICAL CONTRACTOR. RACEWAY <br />INSTALLATION SHALL COMPLY WITH DIVISION 27 SPECIFICATIONS. <br />15. THE SYMBOL LEGEND SHOWN ON THIS SHEET ARE ALL INCLUSIVE, SYMBOLS INCLUDED IN THE <br />LEGENDS MAY OR MAY NOT BE USED IN THESE PROJECT DRAWINGS. <br />16. EACH VOICE/DATA OUTLET LOCATION SHOWN, SHALL HAVE A DOUBLE GANG OUTLET BOX WITH A <br />SINGLE GANG PLASTER RING AND (1)1" CONDUIT STUBBED UP TO AN ACCESSIBLE LOCATION ABOVE <br />THE FINISHED CEILING. WORK BY ELECTRICAL CONTRACTOR (DIV. 26) SHALL BE PER SPECIFICATIONS <br />SECTIONS 270528. <br />17. EACH FLOOR MOUNTED VOICE/DATA OUTLET SHALL HAVE A SINGLE GANG SPACE WITHIN THE FLOOR <br />BOX AND (NUMBER OF 1" CONDUITS SHOWN ON THE DRAWINGS) V CONDUITS CONCEALED IN SLAB <br />STUBBED UP TO AN ACCESSIBLE LOCATION ABOVE THE FINISHED CEILING. WORK BY ELECTRICAL <br />CONTRACTOR (DIV. 26) SHALL BE PER SPECIFICATIONS SECTIONS 270528. <br />18. ALL BONDING AND GROUNDING ELEMENTS UTILIZED FOR STRUCTURED CABLING SYSTEM SHALL BE <br />IN COMPLIANCE WITH SPECIFICATION SECTION 270526. <br />19. INSTALLATION OF CATEGORY 6 UTP CABLE, COAX CABLE AND FIBER OPTICS CABLE SHALL BE IN <br />COMPLIANCE WITH SPECIFICATION SECTION 271000. CABLE INSTALLATION AND TERMINATIONS THAT <br />DO NOT COMPLY SHALL BE REPLACED BY THE CONTRACTOR AT NO ADDITIONAL LOST. <br />20. FOR SPACES WITH HARD CEILING PROVIDE CONDUIT FROM THE JUNCTION BOX SHALL BE <br />CONTINUOUS TO THE CORRIDOR CABLE TRAY, OPERATING ROOMS FOR EXAMPLE. <br />21. STRUCTURED CABLING FOR VOICE/DATA SERVICES WILL BE PROVIDED BY AN OWNER APPROVED <br />VENDOR, NOT THE ELECTRICAL CONTRACTOR. <br />22. ALL RACEWAY SYSTEMS SHOWN TO SUPPORT THE INSTALLATION OF THE DIVISION 27 CABLING SHALL <br />BE PROVIDED BY THE ELECTRICAL CONTRACTOR WITH THE EXCEPTION OF INCIDENTAL SLEEVES AND <br />THE RACKS AND LADDER RACK WITHIN THE TELECOMMUNICATIONS ROOM. THESE RACEWAY <br />SYSTEMS SHALL BE INSTALLED PER DIVISION 27 SPECIFICATIONS. <br />SECURITY NOTES <br />1. ALL DOUBLE DOORS ARE TO RECEIVE (1) DOOR POSITION SWITCH ON EACH DOOR <br />LEAF AND SHALL REPORT AS ONE ALARM POINT. <br />2. ALL 120V POWER WIRING SHALL BE INSTALLED IN A SEPARATE CONDUIT. <br />3. ALL CONDUIT ABOVE GRADE SHALL BE METALLIC. <br />4. ALL CONDUIT, WIRING, AND ASSOCIATED BACK BOXES SHALL BE FULLY CONCEALED <br />WITHIN WALLS, FLOORS, AND CEILINGS. <br />5. INSTALLATION OF CATEGORY 6 UTP CABLE SHALL BE IN ACCORDANCE WITH EIA/TIA <br />GUIDELINES. CABLE INSTALLATION AND TERMINATIONS THAT DO NOT COMPLY SHALL BE <br />REPLACED BY THE CONTRACTOR. <br />A. THE MAXIMUM PULLING TENSION SHALL NOT EXCEED 25 POUNDS TO AVOID <br />STRETCHING THE CONDUCTORS. <br />B. THE MINIMUM BENDING RADIUS OF THE CABLE SHALL NOT BE LESS THAN 4X THE <br />OUTSIDE DIAMETER OF THE CABLE. <br />C. THE CABLE SHALL BE INSTALLED WITHOUT KINKS OR TWISTS AND THE APPLICATION <br />OF CABLE TIES SHALL NOT DEFORM THE CABLE BUNDLE. <br />D. STRIP BACK ONLY AS MUCH CABLE JACKET AS IS REQUIRED TO TERMINATE THE <br />CABLE AND THE AMOUNT OF UNTWISTING IN A PAIR AS A RESULT OF THE <br />TERMINATION SHALL NOT EXCEED 0.5 IN. <br />6. INSTALLATION OF FIBER OPTIC CABLES SHALL BE IN ACCORDANCE WITH EIA/TIA <br />GUIDELINES. CABLE INSTALLATION AND TERMINATIONS THAT DO NOT COMPLY SHALL <br />BE REPLACED BY THE CONTRACTOR. <br />A. THE BEND RADIUS FOR INTRABUILDING 2 AND 4-FIBER HORIZONTAL OPTICAL FIBER <br />CABLE SHALL NOT BE LESS THAN 1 IN UNDER NO-LOAD CONDITIONS. WHEN UNDER A <br />MAXIMUM TENSILE LOAD OF 50 LBF, THE BEND RADIUS SHALL NOT BE LESS THAN 2 IN. <br />B. THE BEND RADIUS FOR INTRABUILDING OPTICAL FIBER BACKBONE SHALL NOT BE <br />LESS THAN THAT RECOMMENDED BY THE MANUFACTURER IF NO RECOMMENDATION <br />IS KNOWN, THEN THE APPLIED BEND RADIUS SHALL NOT BE LESS THAN 10 TIMES THE <br />CABLE OUTSIDE DIAMETER UNDER NO-LOAD CONDITIONS AND NOT LESS THAN 15 <br />TIMES THE CABLE OUTSIDE DIAMETER WHEN THE CABLE IS UNDER TENSILE LOAD. <br />C. THE BEND RADIUS FOR INTRABUILDING OPTICAL FIBER BACKBONE SHALL NOT BE <br />LESS THAN THAT RECOMMENDED BY THE MANUFACTURER IF NO <br />RECOMMENDATION IS KNOWN, THEN THE APPLIED BEND RADIUS SHALL NOT BE <br />LESS THAN 10 TIMES THE CABLE OUTSIDE DIAMETER NO-LOAD CONDITIONS AND <br />NOT LESS THAN 20 TIMES THE CABLE OUTSIDE DIAMETER WHEN THE CABLE IS <br />UNDER A TENSILE LOAD UP TO THE RATING OF THE CABLE, USUALLY 600 LBF. <br />7. COORDINATE LOCATION OF ALL FIRE RATED PENETRATIONS PRIOR TO PROCEEDING WITH <br />INSTALLATION. ALL PENETRATIONS THROUGH FIRE RATED BARRIERS SHALL BE <br />COMPLETELY SEALED WITH APPROPRIATE FIRE STOP MATERIAL IN ACCORDANCE WITH <br />NFPA AND FIRE AUTHORITY HAVING JURISDICTION. <br />8. ALL SECURITY PRODUCTS AND SYSTEMS SHALL BE LISTED BY A NATIONALLY RECOGNIZED <br />TESTING LABORATORY <br />9. ALL INTERCOM PRODUCTS SHALL BE LISTED BY A NATIONALLY RECOGNIZED LISTING LABORATORY. <br />10. ACCESS CONTROL EQUIPMENT AND WIRING WILL BE PROVIDED BY AN OWNER APPROVED VENDOR, <br />NOT THE ELECTRICAL CONTRACTOR. <br />11. CCTV CAMERAS AND WIRING WILL BE PROVIDED BY AN OWNER APPROVED VENDOR, NOT THE <br />ELECTRICAL CONTRACTOR. <br />12. ALL RACEWAY SYSTEMS SHOWN TO SUPPORT THE INSTALLATION OF THE DIVISION 27 EQUIPMENT <br />SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. PROVIDE COORDINATION FOR THE <br />INSTALLATION OF THIS RACEWAY SYSTEM WITH THE ELECTRICAL CONTRACTOR. RACEWAY <br />INSTALLATION SHALL COMPLY WITH DIVISION 27 SPECIFICATIONS. <br />TECHNOLOGY DRAWING INDEX <br />SHEET <br />DESCRIPTION <br />ISSUED <br />T001 <br />GENERAL INFORMATION - TECHNOLOGY <br />Yes <br />TD101 <br />LEVEL 1 DEMOLITION PLAN - PHASE 1 - TECHNOLOGY <br />Yes <br />TD102 <br />LEVEL 1 DEMOLITION PLAN - PHASE 2 - TECHNOLOGY <br />Yes <br />T101 <br />LEVEL 1 RENOVATION PLAN - PHASE 1 - TECHNOLOGY <br />Yes <br />T102 <br />LEVEL 1 RENOVATION PLAN - PHASE 2 - TECHNOLOGY <br />Yes <br />T201 <br />TECHNOLOGY - DETAILS <br />Yes <br />T202 <br />TECHNOLOGY - DETAILS <br />Yes <br />1715 N. Westshore Blvd., Suite 600 <br />Tampa„ Florida 33607-3999 <br />904-256-2500 Fax 904-256-2503 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * GB238 <br />'TLC <br />ENGINEERING <br />S 0 L U T 10 N So <br />255 S. Orange Avenue <br />Suite 1600 <br />Orlando, FL 32801 <br />P 407.841.9050 <br />www.tic-engineers.com <br />COA 15 <br />© Copyright 2019 TLC Engineering Solutions, Inc. <br />TLC Project No.: 119333 <br />THINK. LISTEN. CREATE. <br />PROJECT TITLE: <br />KITCHEN RENOVATION <br />ADVENTHEALTH ZEPHYRHILLS <br />PROJECT ADDRESS: <br />7050 Gall Blvd. Zephyrhills, FL 33541 <br />Christopher V. O'Hara, P.E. <br />Florida License #66504 <br />�`% OpHEIR������ii <br />O <br />.� <br />No 66504 <br />O: STATE OF :4 <br />I�v 9234219200�rU1E000088FS. <br />OPER�p S OR <br />HRIST <br />TECTURE. O=TLC EN pa ECTURE, C=US <br />2020 03.26 1 T51:51-04'00' <br />REVISIONS <br />NO. DESCRIPTION DATE <br />DATE ISSUED: 03/20/20 <br />REVIEWED BY: JTA <br />DRAWN BY: MBR <br />DESIGNED BY: JTA <br />PROJECT NUMBER: <br />504- 0226- 000 <br />© 2019 RS&H, INC. <br />SHEET TITLE: <br />GENERAL <br />INFORMATION <br />TECHNOLOGY <br />SHEET ID: <br />T001 <br />I PROJECT STATUS: I <br />CONSTRUCTION DOCUMENTS <br />A <br />N <br />mr <br />0 <br />0 <br />O <br />M <br />N <br />W <br />G <br />0 <br />U <br />H <br />Z <br />uu <br />J <br />U <br />U <br />a <br />Copyright © 2018. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />I <br />4 <br />5 <br />