Laserfiche WebLink
_ _ _ _ 1 I I a <br />'L' --- � I - -- - It I I I II•i of i _. _ <br />I. _. __._ ! 1_ I I i 1 I I _ _ -'_ <br />- - I <br />1 I 2 <br />I 3 ( <br />4 I <br />5 <br />1 <br />r� <br />E <br />a <br />U <br />t <br />.0 <br />C <br />f0 <br />N <br />0 0 <br />z <br />" T <br />N <br />E <br />Y <br />CO <br />=i <br />U <br />Q <br />I <br />Z <br />W <br />U <br />C <br />L <br />A <br />7 <br />OkAr11l117 7MIC 41 <br />f <br />�� Eli <br />CO <br />O <br />co <br />CD SMOKE ZONE 1B <br />N <br />Copyright © 2018. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />4 <br />AREA OF KITCHEN <br />WORK <br />SMOKE COMPARTMENT LIFE SAFETY PLAN -FIRST FLOOR <br />SCALE: 3/32" =11-0" <br />3 <br />SHEET NOTES <br />1, SEE CODE SUMMARY ON SHEET G001 <br />2. SEE GENERAL NOTES FOR LIFE SAFETY PLANS: SHEET G002 <br />SMOKE ZONE 1 G <br />i <br />SMOKE ZONE 1C <br />SMOKE ZONE 1D <br />4 <br />I <br />LIFE SAFETY LEGEND <br />II <br />FIRE EXTINGUISHER <br />FIRE EXTINGUISHER CABINET <br />FHC ! <br />FIRE HOSE CABINET & EXTINGUISHER CABINET <br />HAZARDOUS AREAS <br />FIRE BLANKET <br />SMOKE DETECTOR <br />HEAT DETECTOR <br />EXIT LIGHT <br />EXIT LIGHT W/ DIRECTIONAL ARROW <br />C <br />FIRE ALARM CHIME <br />F <br />FIRE ALARM MANUAL PULL STATION <br />FIRE ALARM STROBE <br />L <br />� I <br />• - <br />STAND PIPE <br />F <br />CARD READER <br />44 <br />EXIT ARROW I CLEAR WIDTH <br />ETD <br />EXIT TRAVEL DISTANCE <br />CPT <br />COMMON PATH OF TRAVEL <br />I THE FOLLOWING REQUIREMENTS & REFERENCES NOTED ARE BASED UPON <br />a. <br />FULLY SPRINKLED BUILDING, AND <br />b. <br />EXISTING HEALTHCARE OCCUPANCY - 2009 NFPA 101, FLORIDA <br />SPECIFIC EDITION <br />c. <br />2007 NFPA 80 <br />LIMITS OF SUITES <br />(NFPA 101 PAR 19-2.5.7) <br />ALL CORRIDOR WALLS ARE TO BE SMOKE TIGHT. <br />GASKETING OF DOORS SHOULD NOT BE NECESSARY <br />(NFPA 101 PAR A,8.4.3.4) (NFPA 101 PAR 19.3.6.3.1) <br />SMOKE RESISTANT CORRIDORS WITH PARTITIONS EXTENDED TO DECK ABOVE <br />(NFPA 101 Par 19.3.61.1) <br />a. 20 MINUTE RATED 134"SOUDCORE WOOD DOOR, FRAME AND WNDOWS (193.63.1) <br />b. POSITIVE LATCHING REQUIRED (A193.6.3.50)1 <br />c. NON RATED PROTECTIVE PLATE ON DOORS, UNLIMITED IN HEIGHT, ARE PERMITTED (19.36.3.121 <br />d. DOOR CLOSER NOT REQUIRED <br />(1936.3.11) <br />e. MAX 118°GAP AT HINGE, LATCH B TOPON PULL SIDE OF SINGLE DOORS AND <br />AT <br />MEETING EDGES OF PAIR OF DOORS <br />(NFPA 806.3.17f <br />f. MAX.1"UNDERCUT FROM STMOF DOOR TO FINISH FLOOR <br />(19.3.6.3.4) <br />g. PERIMETER WALLS OF AREAS OPEN TO CORRIDOR CONSTRUCTED TO MATCH <br />CORRIDOR PARTIONS AND CEILING <br />(842) <br />h. FIRE OR SMOKE DAMPERS NOT REQUIRED <br />(193 7 4) <br />ONE HOUR FIRE WALL ASSEMBLY (NFPA 101 Par 8.3.4.2) <br />a. 314 HOUR RATED DOOR & FRAME <br />(TABLE 8.3A 2) <br />b. SELF CLOSING OR AUTOMATIC CLOSING REQUIRED <br />(83.3.3) <br />c. POSITIVE LATCHING REQUIRED <br />(1936.3.5) <br />d. NON RATED PROTECTIVE PLATE UP TO 48" <br />(193.214) <br />e. MAX 118"GAP AT HINGE, LATCH B TOP ON PULL SIDE <br />(8.5.4.1& NFPA 806.3.1.7) <br />- <br />f. MAX 314"DOOR UNDERCUT <br />(NFPA 804.8.4.1) <br />g. FIRE GLAZING SIZE LIMITED TO AREA TESTED <br />(NFPA 804,45) <br />h, FIRE DAMPERS REQUIRED <br />i. NO LOUVERS IN DOORS <br />(8.3.56.1) <br />(8 43-3) <br />TWO HOUR FIRE WALL ASSEMBLY (NFPA 101 Par 8.3.4.2) <br />a. 1 b2 HOUR RATED DOOR & FRAME <br />(TABLE 8.3 4 2) <br />i2 <br />b. SELF CLOSING OR AUTOMATIC CLOSING REQUIRED <br />(8.3.33) <br />!C POSITIVE LATCHING REQUIRED <br />09.36.3.5) <br />-- <br />d. RATED PROTECTIVE PLATE REQUIRED IF TOP OF PLATE IS GREATER <br />THAN 48" ABOVE BOTTOM OF DOOR <br />(19.3.2.1.4) <br />W <br />e. MAX 11T GAP AT HINGE, LATCH B TOP ON PULL SIDE <br />(85.4.1&NFPA 806317) <br />— <br />I MAX 314"DOOR UNDERCUT <br />(NFPA804.84.1) <br />g. FIRE GLAZING SIZE LIMITED TO AREATESTED <br />(NFPA 8044.5) <br />h. 112 HOUR FIRE DAMPER REQUIRED <br />(8.3.5.6.1) <br />t. NO LOUVERS IN DOORS <br />(84.3.3) <br />ONE HOUR FIRE/SMOKE BARRIER WALL ASSEMBLY (NFPA 101, <br />Par 19-3.7) <br />a, 20 MIN. RATED SOLID CORE WOOD DOOR OR STEEL DOOR&FRAME <br />(TABLE834.2) <br />I . SELF CLOSING OR AUTOMATIC CLOSING REQUIRED <br />(19.3.78&8.54.4) <br />c. POSITIVE LATCHING NOT REQUIRED AT CROSS CORRIDOR DOORS <br />(19.37.8) <br />d. NON RATED PROTECTIVE PLATE UNLIMITED IN HEIGHT IS PERMITTED <br />(19.3.76.1) <br />e. MAX 118" GAP AT HINGE, LATCH & TOP ON PULL SIDE OF SINGLE DOORS <br />AND AT MEETING EDGES OF PAIR OF DOORS <br />(8.5 4.1 & NFPA 80 6.3.1 T) <br />f. EXISTING ASTRAGALS SHALL REMAIN <br />g. MAX 34°DOOR UNDERCUT <br />(NFPA 804.841) <br />h FIRE GLAZING SIZE LIMITED TO AREA TESTED <br />(NFPA 80445) <br />ICI i. FIRE/SMOKE DAMPER(S) REQUIRED <br />(8552) <br />j. NO LOUVERS IN DOORS <br />(84.3.3) <br />TWO HOUR FIREISMOKE BARRIER WALL ASSEMBLY (NFPA 101, Par 19.3.7) <br />ar <br />a. 112 HOUR RATEDDOOR & FRAME <br />(TABLE 83.42) j <br />B <br />b. SELF CLOSING OR AUTOMATIC CLOSING REQUIRED <br />(19.37B&8.54A) <br />c. POSITIVE LATCHING REQUIRED <br />(1937.8) <br />d. RATED PROTECTIVE PLATE REQUIRED IF TOP OF PLATE IS GREATER <br />fY <br />■ <br />THAN 16'ABOVE BOTTOM OF DOOR <br />e. MAX 118"GAP AT HINGE, LATCH & TOP ON PULL SIDE OF SINGLE DOORS <br />(NFPA 8064.5) <br />ry <br />AND AT MEETING EDGES OF PAIR OF DOORS <br />(8.5.418 NFPA 806.3.1.7) <br />f, EXISTING ASTRAGALS SHALL REMAIN <br />® <br />g. MAX 34"DOOR UNDERCUT <br />(NFPA 804.8.4.1) <br />h. FIRE GLAZING SIZE LIMITED TO AREA TESTED <br />(NFPA 804.4.5) <br />i. FIRESMOKE DAMPER(S) REQUIRED <br />B55.2) <br />NO LOUVERS IN DOORS <br />(8.433) <br />RS&H <br />1715 N. Westshore Blvd., Suite 600 <br />Tampa„ Florida 33607-3999 <br />904-256-2500 Fax 904-256-2503 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * GB238 <br />Advent Health <br />PROJECT TITLE: <br />KITCHEN RENOVATION <br />ADVENTHEALTH ZEPHYRHILLS <br />PROJECT ADDRESS: <br />7050 Gall Blvd. Zephyrhills, FL 33541 <br />SEAL <br />OF F( p��O <br />�P,E <br />••� <br />ioo—JIN K1M <br />• • • • <br />CM <br />• <br />�•• AR95652 ;� <br />% f , <br />c <br />c <br />r <br />ED A." <br />N <br />by VarJin Kim <br />ON: .a11 Nim. <br />W <br />Y00—J i n OO--R I,N.,.-.COnI5I902z6 A0000830 <br />O <br />DaW2MM.2921.50.52-W <br />Z <br />W <br />SIGNATURE <br />J <br />V <br />Q <br />U <br />Q <br />REVISIONS <br />DATE ISSUED: 03/20/2020 <br />REVIEWED BY: YK <br />DRAWN BY: YK/KN <br />DESIGNED BY: JS <br />PROJECT NUMBER: <br />504- 0226- 000 <br />© 2019 RS&H, INC. <br />SHEET TITLE: <br />SMOKE <br />COMPARTMENT LIFE <br />SAFETY PLAN <br />Al 01 <br />8 0 8 16 <br />PROJECT STATUS: <br />CONSTRUCTION <br />SCALE: 118" =1'-0° DOCUMENTS <br />5 <br />