My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (110)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (110)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 4:06:26 PM
Creation date
2/19/2025 8:37:43 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 3 4 5 6 7 8 9 10 11 12 13 14 <br />L <br />i <br />K � <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />J � <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />H � <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />G j <br />1 <br />1 <br />1 <br />1 <br />F <br />E <br />An <br />ABBREVIATIONS <br />A <br />AMPERE <br />AF <br />AMPERE FRAME <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />AHU <br />AIR HANDLING UNIT <br />AL <br />ALUMINUM <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />AWG <br />AMERICAN WIRE GAUGE <br />C <br />CONDUIT <br />CAT <br />CATEGORY <br />CB <br />CIRCUIT BREAKER <br />CH <br />CHILLER <br />CKT <br />CIRCUIT <br />CL <br />CENTER LINE <br />CLG <br />CEILING <br />CU <br />COPPER <br />DWG DRAWING <br />EC <br />ELECTRICAL CONTRACTOR <br />EF <br />EXHAUST FAN <br />EM <br />EMERGENCY <br />EMT <br />ELECTRICAL METALLIC TUBING <br />ENCL <br />ENCLOSURE <br />EWH <br />ELECTRIC WATER HEATER <br />EXIST, EX <br />EXISTING <br />FA <br />FIRE ALARM <br />FCP <br />ARE ALARM CONTROL PANEL <br />FACC <br />FIRE ALARM COMMAND CENTER <br />FATC <br />FIRE ALARM TERMINAL CABINET <br />FO <br />FIBER OPTIC <br />GA <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GND,G <br />GROUND <br />HOA <br />HAND -OFF -AUTO <br />HACR <br />HEATING/AIR CONDITIONING -RATED <br />HID <br />HIGH INTENSITY DISCHARGE <br />HPF <br />HIGH POWER FACTOR <br />HPS <br />HIGH PRESSURE SODIUM <br />HP <br />HORSEPOWER <br />IG ISOLATED GROUND <br />JB JUNCTION BOX <br />KCMIL THOUSAND CIRCULAR MILS <br />KVA KILOVOLT AMPERE <br />KW KILOWATT <br />MCB <br />MAIN CIRCUIT BREAKER <br />MCC <br />MOTOR CONTROL CENTER <br />MDP <br />MAIN DISTRIBUTION PANEL <br />MH <br />METAL HALIDE <br />MLO <br />MAIN LUGS ONLY <br />MTD <br />MOUNTED <br />NC <br />NORMALLY CLOSED <br />NEC <br />NATIONAL ELECTRICAL CODE <br />NEMA <br />NATIONAL ELECTRICAL MANUFACTURERS ASSOC. <br />NF <br />NON -FUSED <br />NFPA <br />NATIONAL FIRE PROTECTION ASSOCIATION <br />NIC <br />NOT IN CONTRACT <br />NL <br />NIGHT LIGHT <br />NO <br />NORMALLY OPEN <br />PNL PANEL <br />0 PHASE <br />PB PUSHBUTTON <br />PVC POLYVINYL CHLORIDE CONDUIT <br />RGC RIGID GALVANIZED STEEL CONDUIT <br />SW SWITCH <br />SWBD SWITCHBOARD <br />TVSS <br />TRANSIENT VOLTAGE SURGE SUPPRESSOR <br />TS <br />TIME SWITCH <br />XFMR <br />TRANSFORMER <br />TYP <br />TYPICAL <br />UG <br />UNDERGROUND <br />UH <br />UNIT HEATER <br />UPS <br />UNINTERRUPTIBLE POWER SUPPLY <br />LION <br />UNLESS OTHERWISE NOTED <br />VAV VARIABLE AIR VOLUME <br />VFD VARIABLE FREQUENCY DRIVE <br />V VOLT <br />WP WEATHER PROOF <br />POWER LEGEND <br />HOMERUN TO PANEL INDICATED (CONCEALED). MINIMUM 3/4"C. UNLESS <br />OTHERWISE NOTED PROVIDE #12 CONDUCTORS AS REQUIRED BY <br />NUMBER OF CIRCUITS SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL <br />LPG CONDUCTORS. FOR HOMERUNS EXCEEDING 100' IN LENGTH PROVIDE #10 <br />CONDUCTORS IN LIEU OF #12 AS INDICATED ABOVE. THERE SHALL BE A <br />MAXIMUM OF 3 BRANCH CIRCUITS PER HOMERUN (AS INDICATED ON <br />PLANS). TEXT SHOWN BY HOMERUN INDICATES PANELBOARD DESIGNATION <br />AND CIRCUIT NUMBER(S). <br />CONDUIT CONCEALED IN WALL OR ABOVE CEILING SPACE. UNLESS OTHERWISE <br />NOTED PROVIDE #12 CONDUCTORS AS REQUIRED BY NUMBER OF CIRCUITS <br />SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL. MINIMUM 1/2"C. <br />UNDERGROUND CONDUIT OR BELOW SLAB. UNLESS OTHERWISE NOTED <br />PROVIDE #12 CONDUCTORS AS REQUIRED BY NUMBER OF CIRCUITS <br />SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL. MINIMUM 3/4"C. <br />- - - - - EXISTING CONDUIT. AS INDICATED. <br />Q CEILING OR WALL MOUNTED JUNCTION BOX. UON SIZE AS REQUIRED <br />BY NEC. <br />�. MOTOR. AS INDICATED. <br />6 120/240V 10 3W PANELBOARD. AS INDICATED. <br />HEAVY DUTY DISCONNECT SWITCH, NON FUSIBLE. SEE SPECIFICATIONS. <br />E' LION MOUNT TOP OF ENCLOSURE 66" AFF <br />HEAVY DUTY FUSIBLE DISCONNECT SWITCH. FUSED AS INDICATED ON <br />PLANS. SEE SPECIFICATIONS. LION MOUNT TOP OF ENCLOSURE 66" AFF. <br />Q� DUPLEX RECEPTACLE. 20A 120V LION CENTERLINE MOUNTED 18" AFF <br />qp DUPLEX RECEPTACLE. 20A 120V LION CENTERLINE MOUNTED 42" AFF <br />DOUBLE DUPLEX RECEPTACLE OUTLET. 20A 120V UON CENTERLINE <br />MOUNTED 18" AFF. <br />DOUBLE DUPLEX RECEPTACLE OUTLET. 20A 120V LION CENTERLINE <br />MOUNTED 42" AFF. <br />GENERAL NOTES <br />ELECTRICAL SPECIFICATIONS <br />1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH: <br />NFPA 70, 2005 EDITION <br />NFPA 72, 2002 EDITION. <br />NFPA 101, LIFE SAFETY CODE 2003 EDITION. <br />FLORIDA BUILDING CODE 2004 EDITION. INCLUDING THE 2005 AND 2006 <br />AMENDMENTS. <br />FLORIDA FIRE PREVENTION CODE 2004. <br />NFPA 99, STANDARD FOR HEALTHCARE FACILITIES. <br />F.A.C. 59A-3 (FLORIDA ADMINISTRATIVE CODE) HOSPITAL LICENSURE (REV 7/97). <br />AIA GUIDELINE FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND HEALTHCARE <br />FACILITIES, 2006. <br />ALL APPLICABLE RULES AND REGULATIONS OF LOCAL CODES. <br />2. ALL WIRING SHALL BE COPPER TYPE THHN/THWN. SOLID FOR #10 AND <br />SMALLER, STRANDED FOR ALL CONDUCTORS #8 AND LARGER. <br />3. UNLESS OTHERWISE NOTED ALL CABLES AND CONDUCTORS SHALL BE INSTALLED <br />(CONCEALED <br />OR WHERE <br />POOSR I LE) IN A APPROVED RACEWAY, AS FOLLOWS: <br />INTERa) EMT, SET SCREW TYPE FITTINGS OR COMPRESSION TYPE FITTINGS IN DAMP <br />LOCATIONS. <br />b) FLEXIBLE CONNECTION WHIPS (MAXIMUM 6'-0" LENGTH). <br />FLEXIBLE METAL CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO <br />MOTORS, LIGHTING FIXTURES AND OTHER VIBRATING EQUIPMENT. <br />ALL INTERIOR CONDUITS SHALL BE CONCEALED EXCEPT IN ELECTRICAL AND <br />MECHANICAL ROOMS. <br />EXTERIOR (CONCEALED OR EXPOSED): <br />a) RIGID GALVANIZED CONDUIT OR INTERMEDIATE METAL CONDUIT, (THREADED <br />FITTINGS AS MANUFACTURED BY CONDUIT MANUFACTURER). <br />b) FLEXIBLE LIQUIDTIGHT CONNECTION WHIPS (MAXIMUM 6'-0" LENGTH). <br />FLEXIBLE LIQUIDTIGHT CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS <br />TO MOTORS AND OTHER VIBRATING EQUIPMENT. <br />ALL RACEWAYS SHALL BE INSTALLED PERPENDICULAR AND PARALLEL <br />TO MAJOR STRUCTURAL ELEMENTS AND IN A NEAT AND WORKMAN LIKE <br />MANNER. <br />EXTERIOR (UNDERGROUND): <br />a) SCHEDULE 40 PVC. <br />4. DISCONNECTING MEANS SHALL BE OF THE HEAVY-DUTY TYPE. UNLESS <br />OTHERWISE INDICATED PROVIDE NEMA 1 ENCLOSURE. <br />5. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIALS INDICATED <br />TO BE REMOVED AS PART OF DEMOLITION WORK OF THIS PROJECT. <br />CONTRACTOR SHALL CLEAN EACH AREA WHERE WORK IS PERFORMED ON A <br />DAILY BASIS. <br />6. ALL CUTTING AND PATCHING SHALL BE RESTORED TO MATCH EXISTING <br />SURFACE AND FINISH. WHERE NECESSARY TO DRILL THROUGH EXISTING ARE <br />RATED PARTITIONS OR FLOORS CONTRACTOR SHALL PATCH USING MATERIALS <br />OF AN EQUIVALENT FIRE RATING. <br />7. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO <br />NEW OR EXISTING WALLS, FLOOR, FURNITURE ETC. AND SHALL REPLACE ANY <br />DAMAGED ITEMS WITHOUT ADDITIONAL COST TO OWNER. USE TEMPORARY <br />COVERS TO AVOID SPREAD OF DUST AND CONSTRUCTION DEBRIS. <br />8. UPON COMPLETION OF THE WORK THE ELECTRICAL CONTRACTOR SHALL <br />TEST ALL NEW EQUIPMENT, DEVICES, ETC. FOR PROPER OPERATION. <br />REPLACE MALFUNCTIONING UNITS AND RE -TEST TO FULFILL REQUIREMENTS. <br />9. PANELBOARDS SHALL BE ACCURATELY LABELED TO IDENTIFY FINAL CIRCUIT <br />NUMBERS UTILIZED, THEIR LOAD AND LOCATION. <br />10. ELECTRICAL INSTALLATION SHALL BE CLOSELY COORDINATED WITH ALL OTHER <br />WORK. CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH <br />ILL-TIMED INSTALLATION INCLUDING ANY ASSOCIATED REPAIRS OR <br />REPLACEMENTS. <br />11. "PROVIDE" SHALL MEAN "FURNISH AND INSTALL". <br />12. LIGHTING TOGGLE SWITCHES SHALL BE 20 AMP, SPECIFICATION GRADE <br />TOGGLE TYPE SWITCHES. ALL SWITCHES AND COVERPLATES SHALL BE IVORY. <br />ALL ADJACENT SWITCHES SHALL BE GANGED IN ONE COMMON COVERPLATE/BOX. <br />LOCATIONS AND HEIGHTS SHALL BE COORDINATED WITH DOOR SWINGS AND <br />COUNTER HEIGHTS. <br />13. DUPLEX AND DOUBLE DUPLEX RECEPTACLES SHALL BE 20 AMP, 125 VOLT <br />RATED, SPECIFICATION GRADE. RECEPTACLES SHALL HAVE A GREEN <br />GROUNDING SCREW TERMINAL AND A SELF GROUNDING CLIP. ALL <br />RECEPTACLES SHALL BE YVORY. <br />EXACT LOCATIONS AND MOUNTING HEIGHTS SHALL BE COORDINATED <br />WITH THE COUNTER HEIGHTS AND ALL LOCATIONS SHALL BE VERIFIED WITH <br />THE OWNER PRIOR TO ROUGH -IN. <br />GFCI TYPE RECEPTACLES SHALL BE 20 AMP 125V, NON FEED-THRU TYPE. <br />14. PANELBOARDS SHALL BE EQUIPPED WITH COPPER BUS, 98% CONDUCTIVITY. <br />CIRCUIT BREAKERS SHALL BE OF THE BOLT -ON TYPE, SERIES CONNECTED <br />A.IC. RATINGS SHALL BE ACCEPTABLE AS PER MANUFACTURER'S UL SERIES <br />CONNECTED RATINGS DATA. AVAILABLE MANUFACTURERS SHALL BE: <br />SQUARE D, CUTLER HAMMER AND GE. <br />15. SUPPORTING DEVICES <br />DAMP LOCATIONS AND OUTDOORS: HOT DIP GALVANIZED MATERIALS, U CHANNEL <br />SYSTEM COMPONENTS. <br />DRY LOCATION: STEEL MATERIALS. <br />STRENGTH OF SUPPORTS: ADEQUATE TO CARRY THE LOAD TIMES A SAFETY <br />FACTOR OF FOUR; MINIMUM 200-LB DESIGN LOAD. <br />16. ELECTRICAL IDENTIFICATION <br />ENGRAVED PLASTIC LAMINATE. INSTALL ON EACH UNIT OF EQUIPMENT. THIS <br />INCLUDES POWER, LIGHTING AND ALL SYSTEMS. <br />USE THE FOLLOWING COLORS FOR SERVICE, FEEDERS AND BRANCH CIRCUITS: <br />1. 120/208V: PHASE A: BLACK. PHASE B: RED. PHASE C: BLUE. <br />2. 277/480V: PHASE A: YELLOW. PHASE B: BROWN. PHASE C: ORANGE. <br />17. TEMPORARY ELECTRICAL SERVICE <br />COST OR USE CHARGES FOR TEMPORARY FACILITIES ARE NOT CHARGEABLE TO <br />THE OWNER, ARCHITECT OR ENGINEER. <br />PROVIDE RECEPTACLE OUTLETS ADEQUATE FOR CONNECTION OF POWER TOOLS <br />AND EQUIPMENT. <br />PROVIDE TEMPORARY LIGHTING WITH LOCAL SWITCHING THAT PROVIDES ADEQUATE <br />ILLUMINATION FOR CONSTRUCTION OPERATION AND TRAFFIC CONDITIONS. <br />DRAWING INDEX <br />ELECTRICAL <br />E-1 LEGEND, ABBREVIATIONS AND GENERAL NOTES <br />E-2 ELECTRICAL PLANS <br />E-3 PANEL SCHEDULE AND DETAILS <br />RISER SYMBOLS LEGEND <br />GROUND FAULT SENSOR <br />b\ CIRCUIT BREAKER. AS INDICATED <br />al <br />DRAWOUT CIRCUIT BREAKER. AS INDICATED <br />L STARTER / CONTACTOR <br />T <br />OGENERATOR <br />b <br />SWITCH <br />THERMAL OVERLOAD ELEMENT <br />TRANSFORMER <br />FUSE <br />1 GROUND <br />cam— RELAY COIL, NOTED WITH TEXT <br />b <br />FUSED SWITCH <br />p <br />AUTOMATIC TRANSFER SWITCH <br />r <br />L <br />METER SOCKET <br />1 <br />REVISION NO.: <br />PROJECT NAME <br />FLORIDA <br />`Y <br />L41< <br />.. r <br />PROFESSIONAL ENGINEERS <br />3203 QUEEN PALM DRIVE <br />TAMPA, FLORIDA 33619 <br />PHONE (813) 241-6488 <br />FAX (813) 241-6498 <br />Board of Professional Engineers — License # 27336 <br />HOSPITAL <br />1 <br />Zephyrhills <br />1 <br />1 <br />1 <br />SHEET CONTENTS <br />1 <br />1 <br />' ABBREVIATIONS, LEGENDS <br />1 <br />' AND GENERAL NOTES <br />1 <br />1 <br />ZEAL I COMMISSION NUMBER <br />1 <br />1 <br />1 1 <br />1 1 RICHARD L. HOCUTT, P.E. <br />A ; - FL. LTC. No. 67155 <br />1 � Cynnture p ate <br />1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 <br />DATE <br />3203 QUEEN PALM DRIVE <br />TAMPA, FLORIDA 33619 <br />PHONE (813) 241-6488 <br />FAX (813) 241-6498 <br />Board of Professional Engineers — Ueense / 27336 <br />1 <br />C j <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />B 1 <br />1 <br />1 <br />n <br />1. TEXT SHOWN ON PLANS ADJACENT TO LIGHTING FIXTURES SHALL DENOTE THE FOLLOWING: <br />LOWERCASE LETTER (BY FIXTURE OR SWITCH) INDICATES LIGHT SWITCH CONTROL. UPPERCASE <br />LETTER INDICATES FIXTURE TYPE. NUMERAL INDICATES BRANCH CIRCUIT NUMBER. <br />2. SHADED LIGHTING FIXTURE SYMBOLS THAT APPEAR ON PLANS INDICATE EMERGENCY LIGHTING <br />FIXTURES AND SHALL BE INTERPRETED AS FOLLOWS: <br />LIFE SAFETY BRANCH CIRCUIT: ED <br />CRITICAL BRANCH CIRCUIT: El <br />EMERGENCY LIGHT FIXTURE <br />WITH BATTERY BACK UP: Im <br />(THE ABOVE SHALL APPLY TO ALL LIGHTING FIXTURE SYMBOLS SHOWN ON LEGEND). <br />3. NUMERALS SHOWN ON PLANS ADJACENT TO WIRING DEVICES INDICATE BRANCH CIRCUIT NUMBER(S). <br />4. STANDARD SYMBOLS SHOWN ON LEGEND MAY NOT ALL APPEAR ON PLANS. WHERE SYMBOL <br />APPEARS ON PLANS FURNISH AND INSTALL AS SPECIFIED. <br />5. ALL STANDARD SYMBOLS ON LEGEND THAT APPEAR ON PLANS WITH HIDDEN LINES SHALL BE EXISTING <br />TO REMAIN (FOR REFERENCE ONLY). EXISTING SYMBOLS (AS DESCRIBED ABOVE) THAT APPEAR ON <br />PLANS WITH AN ADJACENT ABBREVIATION SHALL BE INTERPRETED AS FOLLOWS: <br />RL = EXISTING TO BE RELOCATED (SHOWN AT EXISTING LOCATION ON DEMOLITION PLAN). <br />REFER TO INSTALLATION PLAN FOR NEW LOCATION. CONTRACTOR SHALL EXTEND WIRING TO NEW <br />LOCATION AND RECONNECT. <br />R = EXISTING TO BE REMOVED. CONTRACTOR SHALL REMOVE DEVICE AND/OR EQUIPMENT AND <br />UNLESS OTHERWISE NOTED REMOVE ALL UNUSED CONDUIT AND WIRING. <br />DATE: <br />Out Patient Lobby <br />H.C. Chair Lift Installation <br />3-10-08 <br />DRAWING NUMBER <br />SHEET <br />OF <br />i <br />
The URL can be used to link to this page
Your browser does not support the video tag.