My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7250 Steer Blade Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7250 Steer Blade Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 12:15:02 PM
Creation date
2/19/2025 7:53:17 AM
Metadata
Fields
Template:
Building Plans
Street #
7250
Location
Steer Blade Dr
Contractor
DR Horton
Building Plans - Permit #
1885
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SALL. BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FA15 4 MASTIC. AND <br />INSTALLED AS PER FBC ITN EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 'ITN EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRICTED IN ACCORDANCE TO FBC 9TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC ITH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOOR$ FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS $HALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND MC 'tTH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A PANTEC14 DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />II II <br />/I <br />— L='J <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />m <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />BALANCING DAMPER OR OBO <br />O <br />CEILING EXHAUST FAN <br />.� <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />® <br />PASS-THRU AIR GRILL <br />MECHANICAL PLAN <br />SCALE: 1/4 " 1'-0' <br />SCORIATED NICKEL FIN. FLOOR <br />L � <br />BRONZE FL. POR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K "SAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (TY�PN. ) <br />COUNTERSINK <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-8'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN -OUT TYPN <br />SECURE STRAP TO CONC. <br />CONDENSER <br />W/ (2)-3/16'X2' TAPCONB <br />UNIT <br />SIMPSON WE, ROLL STRAP <br />OR EQUAL <br />4' CONCRETE BLAB <br />SECURE STRAP TO UNIT W/ (2) <br />GBXI 1/4' SHT. MTL. SCREWS <br />CONDENSER <br />UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PAN$ W/ DRAINS <br />ATTIC <br />"` �""' <br />1010 <br />EXTERIOR WALL <br />PLENUM*MECHANICAL <br />AIR RETURN <br />ON AND LIQUID <br />AIR SUPPLYGERANT <br />LINES <br />AIR HANDLERMAR <br />IOR WALLVC <br />CONDENSATE DRAIN LINE <br />EVAP. TRAYLEEVE <br />TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />PLATFORMCONDENSING <br />UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR ITN EDITION (2020) <br />BLDG. CODE <br />SECTION 3073.4 <br />HVAC <br />DRAINS <br />Groui In <br />19 1 N. KVNALU KLAVAN t$LVU. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774 4078 <br />www.abdesigngroup.com <br />L AA #: 0003325 <br />le <br />0 <br />a <br />V <br />0 <br />14 <br />Surimm a4 LOT <br />SILVERADO <br />LOT #10 <br />BLK #15 <br />PROJECT# <br />03719.001-10151 <br />MODEL: <br />"2558-HAWTHORNE" <br />GARAGE SIWMG: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />15 PH <br />DATE: 03/02/21 <br />SCALE: 1/4"=l'-0" <br />SHEET <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.