My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7631 Gall Blvd (14)
Zephyrhills
>
Building Department
>
Building Plans
>
7631 Gall Blvd (14)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 4:09:53 PM
Creation date
2/19/2025 8:40:14 AM
Metadata
Fields
Template:
Building Plans
Street #
7631
Location
Gall Blvd
Contractor
TDS Construction
Building Plans - Permit #
1094
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7$" <br />7'-4" <br />M.O .-- <br />WELD EXISTING DOC <br />CLOSED AT EXTERIC <br />FACE OF DOOR WITt <br />2" LONG 1/8" STITCH <br />WELDS AT 8" O.C. <br />PER PLAN E <br />O I EXISTING CMU WAIA <br />U� <br />7I CONTINUOUS SEALANT <br />PLAN BATT INSULATION <br />CONTINUOUS BACKER EXISTING HOLLOW METAL <br />ROD AND SEALANT DOOR WELDED SECURELY <br />BETWEEN DOOR AND TO HOLLOW METAL FRAME <br />FRAME, ENTIRE PERIMETER <br />INFILL DETAIL AT CMU WALL <br />EXISTING 8" CMU <br />EXTERIOR SALES <br />WALL <br />TOP TRACK <br />1-5/8" X 25 GA METAL <br />AT 24" OC <br />1/2" = 1'-O" <br />F• <br />SECTION AT D <br />3/8" GYPSUM <br />BOARD FLUSH WITH <br />EXISTING SALES <br />FLOOR WALL. PAINT <br />TO MATCH <br />ADJACENT WALLS <br />1 LAYER OF 1/2" <br />PLYWOOD SHEATHING <br />BATT INSULATION <br />BOTTOM TRACK SET <br />IN CONTINUOUS <br />SEALANT BED <br />SECTION <br />MODIFY EXISTING <br />CEILING GRID AND TILE <br />AS REQUIRED FOR <br />INSTALLATION OF NEW <br />WALL <br />2'-0" AFF <br />BOTTOM OF LINTEL <br />RETURN WALL <br />MATERIAL AND <br />FINISHES AT OPENING <br />SANITARY COVE BASE, <br />REFER 6-GA2 <br />A <br />UPRIGHT TUBE BY VENDOR <br />PLAN VIEW <br />91, <br />FLOOR TUBE RAIL BY \ <br />3/8"-16x3" WEDGE <br />ANCHOR AT ENDS <br />AND AT EACH <br />SECTION, DRILL TO <br />MIN. DEPTH OF 1 3/4". <br />SECTION VIEW <br />12 <br />PICKUP WALL SYSTEM FLOOR MOUNTING <br />G.C. TO REFERENCE <br />MANUFACTURER'S CUT SHEETS <br />A FOR NUMBER AND LOCATIONS <br />. OF FLOOR ANCHORS. <br />.4602" DIA HOLE BY VENDOR <br />14'-0" <br />P131 UP TO 14'-0" <br />CEILING AS SCHEDULED <br />PAINT WALL TO <br />MATCH ADJACENT <br />I r-------� <br />I I i i <br />I I i <br />I i i <br />I i i <br />f I i i <br />I I i I <br />ii <br />i <br />I SEAFOOD CASE <br />i i n <br />i <br />SECTION AT NON -SERVICE SEAFOOD <br />:XISTING FLOOR TO REMAIN <br />lOOR ANCHOR <br />'HRU BOTTOM <br />IOLE IN TUBE <br />EXISTING WALL <br />STUDS <br />0 <br />0 <br />N <br />FASTEN MILLWORK TO <br />BLOCKING AT THE <br />CENTER OF EACH <br />TRASH BIN AREA WITH <br />(2) 1/4" X 3" L. <br />GALVANIZED LAG <br />SCREWS AND WASHERS. <br />REMOVE BASE BEHIND <br />TRASH BIN PORTION OF <br />MILLWORK <br />CHECK WRITING DESK ELEVATION <br />1/4" = 1'-01, <br />WALL STANDARD SPACING PER FINAL <br />MERCHANDISE PLAN. <br />AT TV WALL GONDOLAS, ANCHOR AS <br />{ INDICATED ON RACK ANCHORAGE PLAN <br />II <br />II <br />II <br />II <br />II <br />I � GONDOLA <br />{ I <br />{I <br />II <br />ANCHOR AS INDICATED ON <br />RACK ANCHORAGE PLAN <br />PAINT 1x6 FURRING AND <br />FASTENERS TO MATCH <br />WALL FINISH (TYP) <br />APPLY CONT. CONSTRUCTION ADHESIVE <br />BETWEEN EXISTING WALL AND NEW CONT. <br />1x6 FURRING. SECURELY FASTEN FURRING <br />WITH (2) TEK SCREWS, AS SPECIFIED IN <br />SECTION 06100, AT EACH WALL STUD <br />LOCATION. COUNTER SINK ALL FASTENERS. <br />GONDOLA ANCHORING ON STUD WALL <br />1/2" = 1'-O" 1 , / 3/4" = 1'-O" <br />AT SALES FLOOR WALL STANDARDS, GONDOLAS <br />WALL STANDARDS, <br />INSTALL WAINSCOT AND BASE AFTER <br />AND WAREHOUSE RACKING WITHOUT PEG -BOARD <br />GONDOLAS AND WAREHOUSE MERCHANDISE RACKS ARE SET, IN <br />BACKING (WALL VISIBLE THROUGH FIXTURE) PAINT <br />RACKING SHOWN DASHED <br />AREAS SHOWN, UP TO EDGE OF <br />WALL AND WALL STANDARD WOOD STRIPS TO BASE <br />FOR CLARITY. <br />EXISTING WALL STANDARDS OR <br />GONDOLAS. <br />PAINT AS <br />INDICATED _' •. <br />OMIT PAINT AS <br />INDICATED, EXCEPT .- . <br />; - _ AT ALL PERIMETER WALL <br />AS NOTED ABOVE <br />`, _ STANDARDS, GONDOLAS <br />AND/OR WAREHOUSE <br />oiL6'-10" AFF <br />RACKS CONTINUE PAINT TO <br />PAINT TRANSITION (TYP AT <br />OUTERMOST UPRIGHT <br />HALF -GONDOLAS) _ ; _• , <br />FRAME <br />OPEN TO <br />WAINSCOT AS INDICATED. <br />o j BEYOND <br />ON EXPOSED WALLS <br />+++' <br />"- <br />++ - + WHERE WAINSCOT IS NOT <br />+++ <br />+'+` %+ TO BE INSTALLED, <br />+ CONTINUE PAINT TO FINISH <br />++ <br />+ + <br />+ '�++ ++ <br />+++ <br />+ +.++ , FLOOR <br />+ +' +' + + <br />+ + + + + <br />+++ ++ <br />+++ <br />+ <br />, + + + + + <br />+ + + + + + D B 5 <br />+ + <br />++ ++ <br />REF PLAN <br />LES <br />VARIES <br />V LILIIYV nV JVI ILDULED <br />ELI BULKHEAD <br />SALES WALL FINISHES @PERIMETER HALF -GONDOLAS <br />T <br />I <br />NOTE: DO NOT PAINT <br />ABOVE CEILING <br />PAINT GIRDER OR <br />JOIST DIRECTLY <br />ADJACENT TO WALL <br />TO MATCH. COLOR <br />AS INDICATED <br />ITPAINT COLUMN TO <br />MATCH ADJACENT <br />WALL AS INDICATED <br />PAINT CMU FROM <br />FINISH FLOOR TO <br />1 DECK AS <br />SCHEDULED <br />FLOOR FINISH AS <br />100'-0" SCHEDULED <br />FF EL <br />EXISTING EXT CMU WALL <br />SECTION <br />4" <br />INTERIOR HM DOORS INTERIOR FULL HEIGHT <br />TRAFFIC DOORS ALT <br />INTERIOR BOLLARD DETAIL <br />1/2" <br />SECTION AT BAKERY RACKS <br />3/8" = 1'-0" <br />P162 <br />NG P131 14'-0" <br />EXISTING METAL <br />STUDS <br />EXISTING <br />BULKHEAD <br />PAINT 6 BEHIND <br />J <br />TOP AND SIDES <br />OF REFRIGERATED <br />I <br />CASES. <br />I <br />i <br />I <br />P131 <br />REFRIGERATED <br />i <br />CASE <br />i <br />i <br />i <br />BULKHEAD AT CASE <br />1/2" = 1'-01, <br />BUILDING WALL <br />2"x3/4" PLYWOOD FURRING <br />STRIPS. WALL STANDARD <br />SPACING PER FINAL <br />MERCHANDISE PLAN <br />PEG BOARD <br />SHELF STANDARD MOUNTED <br />ON FURRING STRIPS <br />A_ <br />INSERT 5/16"x1-1/2" <br />ELEVATOR BOLT INTO <br />PREDRILLED HOLE FROM BACK <br />OF FURRING STRIP <br />3" POWDER <br />ACTUATED <br />FASTENER <br />TOP OF STANDARD LTOP OF STANDARD <br />96" AFF 96" AFF INSERT 5/16"x1-1/2" <br />ELEVATOR BOLT INTO <br />PREDRILLED HOLE I '� <br />FROM BACK OF <br />FURRING STRIP I i <br />EXISTING WALL i <br />2"x3/4" PLYWOOD FUR I i <br />STRIPS. WALL STANDARD <br />3/8"x 3" LAG BOLT SPACING PER FINAL { i <br />SPACE AT 24" OC MERCHANDISE PLAN <br />VERTICALLY <br />PEG BOARD BETWEEN <br />SHELF STANDARDS <br />SHELF <br />STANDARDS <br />WALL STANDARD MOUNTED ON A_ <br />SPACING PER FINAL FURRING STRIPS <br />MERCHANDISE PLAN ADHESIVE APPLIED TO <br />EXISTING BLOCKING BACK OF PLYWOOD <br />FURRING STRIP <br />POWDER ACTUATED <br />FASTENER SPACED <br />EVENLY. APPLY EVERY <br />SECOND BLOCK AT <br />CENTERLINE OF BLOCK <br />BASE DECK (FIXTURE) BASE DECK (FIXTURE) <br />GYP BD WALL CMU WALL <br />WALL STANDARD MOUNTING <br />pLLpOH W <br />WZ Q <br />u�2w¢ <br />w <br />in <br />=O <br />OW FI=-W2 <br />D <br />I- ZU LLm <br />p�~�gOq"U f-Q <br />a z Ow=0zw <br />NUF-Z2Q <br />-'WWLL <br />p Q fn fn <br />O <br />>u> <br />zg50WiwaZW�x�° <br />Q <br />0 Uco� 0' <br />U0ola-OUWw}�Qrn¢ <br />w Z W z~ J w U' F� <br />W 0 ofD W U L z Z U O <br />d <br />�-- <br />(n<Z�LLWLL005QOU <br />(1) <br />=z0wofwzrY�w <br />I-OUpaF wd a. W pn. In <br />z <br />Q <br />J <br />m <br />z <br />O <br />U <br />m <br />a <br />©0 <br />T <br />:) ©J M C=coM <br />{ 0 <br />IL LL <br />J N <br />O <br />Of co0 <br />=o <br />a <br />do <br />M <br />Nz <br />o <br />N <br />Q W <br />�m0 <br />0 <br />J� <br />6i <br />W� <br />NM <br />cD <br />ti <br />w <br />m <br />0 <br />z <br />m <br />O <br />ISSUE BLOCK <br />1 1 CCD4 06/21 /21 <br />CHECKED BY: <br />RD <br />DRAWN BY: <br />EB <br />PROTO CYCLE: <br />09/25/20 <br />DOCUMENT DATE: <br />11/06/20 <br />07/01 /21 <br />SECTIONS <br />AND DETAILS <br />1/4" <br />12" <br />SHEET: <br />A3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.