Laserfiche WebLink
'IF1"'UTIIF,r1,11'7T7"!. " 1 ;I <br />m <br />a <br />PNL D3D4 <br />10 TYP F D3D4-22 <br />CO <br />\r <br />CD30 GFI I <br />O GFI CD15 <br />- D3D4-18 9 CD15 <br />D3D4-14 GFI \� <br />�I <br />�I O <br />— QUAD RESTROOM <br />RECEPTACLE, RECEPTACLES <br />TYP SHALL BE DUPLEX <br />AT 48" AFF <br />o B- <br />CUT OFF AND CAP AT TOP <br />OF FLOOR SLAB ANY <br />EXISTING CONDUIT STUB INS <br />THAT ARE NOT USED. <br />D3D4-20 <br />q <br />D3134-38:40:42 D3D4-37:39:41 <br />D3D4-16 <br />O O <br />� IO QI I <br />IQ Q <br />0 <br />b <br />$) <br />co <br />D3D4-6 D3D4-8 <br />o, D3D4-2 <br />SW SW <br />►O\ <br />D3134-10 Q D3D4-12 <br />CD30 <br />D3D4-4 <br />Sw F SW <br />O <br />1 Electrical Power Plan <br />Scale 1/8"=T-0" <br />Power Plan Key Notes: <br />Q EXISTING J-BOX AND EMPTY 3/4" CONDUIT. EXTEND <br />O <br />EXISTING TELEPHONE CONDUIT STUB IN TO REMAIN AS IS. <br />CONDUIT AS NEEDED AND RUN NEW WIRES TO NEW <br />NO TELEPHONE TERMINAL BOARD OR RECEPTACLE <br />TENANT PANEL. <br />ADDED. THE TENANT SHALL BE RESPONSIBLE FOR <br />Q EXISTING 5 TON RTU TO BE WIRED BACK TO NEW TENANT <br />PULLING THE COMMUNICATION CABLE FROM THE <br />EXISTING TELEPHONE TERMINAL CABINET TO THE SPACE <br />PANEL. CONTRACTOR SHALL VERIFY THAT THERE IS AN <br />AND FOR PROVIDING THE TELEPHONE TERMINAL BOARD <br />EXISTING SMOKE DUCT DETECTOR IN THE SUPPLY DUCT. <br />AS PART OF THE FUTURE TENANT WORK. <br />IF THERE ISN'T, REFER TO MECHANICAL GENERAL NOTE # <br />7 ON SHEET M101. THE GC SHALL BE RESPONSIBLE FOR <br />O7 <br />EXISTING HOUSE TTC AND DEDICATED RECEPTACLE FOR <br />COORDINATING THE EXACT SCOPE OF WORK REQUIRED <br />TTC TO REMAIN AS IS. <br />BETWEEN THE MECHANICAL SUB AND THE ELECTRICAL <br />SUB PRIOR TO BIDDING. NO CHANGE ORDERS WILL BE <br />8O <br />EXISTING HOUSE PANEL AND ELECTRICAL POWER RISER <br />APPROVED FOR FAILURE TO VERIFY EXISTING <br />TO REMAIN AS IS. <br />CONDITIONS OR COORDINATE BETWEEN SUBS. <br />O9 <br />ALL FIRE ALARM EQUIPMENT IS SHOWN FOR REFERENCE <br />30 EXISTING FACTORY INSTALLED DISCONNECTS. FOR <br />PURPOSES ONLY. FIRE ALARM DESIGN DRAWINGS SHALL <br />POWER REQUIREMENTS TO RTU'S, RE: M101 AND <br />BE SUBMITTED BY TENANT BUILDOUT CONTRATOR, <br />ELECTRICAL PANEL SCHEDULE ON THIS SHEET. <br />SIGNED AND SEALED BY STATE OF FLORIDA LICENSED <br />AND REGISTERED ENGINEER. <br />4 EXISTING FACTORY INSTALLED POWERED CONVENIENCE <br />OUTLET. INSTALLATION SHALL BE PER SECTION 210.63 OP <br />PROVIDE Or`E• Q�T V dCNJECTI0"� PORT NEXT TO EACH, <br />THE NEC. COORDINATE WITH MECHANICAL. <br />QUAD RECEPTACLE. PROVIDE 1/2" CONDUIT W/ PULL <br />CORD UP TO SPACE ABOVE CEILING OUTSIDE OF <br />O NEW 200 AMP TENANT ELECTRICAL PANEL INSTALLED IN <br />DEMISING WALL. CAP ABOVE CEILING FOR FUTURE <br />THE LOCATION OF THE EXISTING 4" CONDUIT STUB <br />TENANT CONNECTION. <br />UP. REFER TO RISER DIAGRAM ON THIS SHEET. <br />F- <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />io <br />F_ <br />Q <br />rn <br />2 Electrical Lighting Plan <br />Scale 118"=V-0" <br />22 C <br />Light Fixture Schedule <br />TYPE <br />MANUFACTLRER <br />CATALOG NO. <br />VOLT <br />LAMPS <br />MOUNTING & OPTION <br />NOTE <br />A <br />DAYBRITE <br />2TGB-3-32-01-UNV-1/3-EB <br />120 <br />(3) 32W T8 <br />GRID MOUNTED <br />1-3,5-6 <br />C <br />NITE BRITES <br />WCR-050-M-MT <br />120 <br />- <br />EXISTING TO REMAIN <br />EM <br />BEGHELLI <br />XLP-S1 <br />120 <br />- <br />WALL MTD 9'-0"AFF <br />2 & 4 <br />X <br />BEGHELLI <br />VA4-R-SA <br />120 <br />LED (INCLUDED) <br />UNIVERSAL <br />2 & 4 <br />ALTERNATE FIXTURES MAY BE COOPER, LITHONIA,. GENLYTE, HUBBELL, OR THOMAS. FIXTURE <br />SUBSTITUTIONS MUST BE APPROVED BY OWNER BEFORE THEY ARE SUBMITTED TO THE ENGINEER. <br />1. ALL FLUORESCENT LIGHTING FIXTURES SHALL 4. <br />ALL EMERGENCY, EXIT AND NIGHT LIGHT FIXTURES <br />HAVE ENERGY SAVING LAMPS AND ELECTRONIC <br />SHALL BE CONNECTED AHEAD OF LOCAL SWITCHES. <br />BALLASTS. <br />UNLESS OTHERWISE NOTED. <br />2. PROVIDE NECESSARY MOUNTING HARDWARE 5. <br />ALL ALTERNATE FIXTURES SHALL BE SUBMITTED <br />e <br />:QI�°D ACCESSORIES FOR ��.�z FIXTURES. <br />FOR RR.r �-B APPRO.%L„ SEE SPECIFICATIONS. <br />3. PROVIDE .125 MIN. THICK LENSES FOR 6. <br />CONTACT SESCO LIGHTING (407) 629-6100 DAN <br />FLUORESCENT FIXTURES. <br />SCHULMAN <br />EXISTING 12" X 12" WP WIREWAY WITH KEY TAPS <br />EXISTING <br />1200 AMP <br />DISCONNECT <br />0 <br />0 <br />0 <br />1 <br />0 <br />3P 14W <br />1201208 V <br />NEMA 3R <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />200 AMP <br />200 AMP <br />200 AMP j <br />200 AMP <br />UTILITY COMPANY <br />DIS- <br />DIS- <br />DIS- <br />DIS- <br />TRANSFORMER <br />CONNECT <br />CONNECT <br />CONNECT <br />CONNECT <br />2 <br />4 <br />5 <br />EXISTING SECONDARY - <br />EXISTING GROUND <br />3 Building Power Riser Diagram <br />SCALE: NTS <br />EXISTING <br />400 AMP <br />DISCONNECT <br />RISER KEY NOTES: <br />PROVIDE DOOR STOP TO PREVENT DAMAGE <br />TO ELECTRICAL PANEL. RE: HARDWARE <br />SCHEDULE ON ARCHITECTURAL DRAWINGS. <br />Lighting Plan Key Notes: <br />21 EXISTING DECORATIVE SCONCE FIXTURES SHALL REMAIN WIRED <br />AS IS TO THE EXISTING HOUSE PANEL. <br />22 EXISTING REAR WALL MOUNTED LIGHT SHALL BE WIRED TO THE <br />NEW TENANT PANEL VIA A NEW LIGHT SWITCH. <br />Lighting General Notes: <br />1. VENDOR SHALL VERIFY ALL FIXTURE QUANTITIES. <br />2. VERIFY FIXTURE LOCATION, SEE REFLECTED CEILING PLAN. <br />3. MOUNTING HEIGHTS INDICATED ARE TO THE CENTER LINE OF DEVICE <br />OR FIXTURE UNLESS OTHERWISE NOTED. <br />4. ALL FIXTURES TO BE CENTERED ON 2X4 CEILING GRID U.O.N. <br />5. ALL FIXTURES TO BE PROVIDED BY, RECEIVED, STORED & INSTALLED <br />BY ELECTRICAL CONTRACTOR. .-._..,_. <br />6. ELECTRICAL CONTRACTOR SHALL SUPPLY 10% ADDITIONAL SPARE OF <br />ALL LAMP TYPES TO BE LEFT AT JOB SITE AT END OF JOB. <br />7. CIRCUIT BREAKERS USED AS SWITCHES IN 120V AND 277V <br />FLUORESCENT LIGHTING CIRCUITS SHALL BE LISTED AND SHALL BE <br />MARKED SWD OR HID. <br />1. EXISTING 4 # 3/0, 1 # 3/0 G, IN EXISTING 2" CONDUIT 6. NEW 4" TO 2" REDUCER AT THE TOP OF THE EXISTING <br />CONDUIT STUB IN. <br />2. EXISTING 2" CONDUIT WITH PULL CORD. <br />3. EXISTING 4" TO 2" REDUCER. 7. (4) NEW # 3/0 & (1) NEW # 6 GROUND IN NEW 2" CONDUIT. <br />8. 7-DAY, 4 CIRCUIT PROGRAMMABLE TIME CLOCK <br />4. EXISTING 4" CONDUIT WITH PULL CORD. <br />ALL WIRING SHALL BE COPPER ONLY. <br />5. (4) NEW # 3/0 & (1) NEW # 6 GROUND IN EXISTING CONDUIT. <br />EXISTING <br />HOUSE <br />PANEL <br />HPD1 <br />120/208 <br />EXISTING <br />HOUSE <br />PANEL <br />HPD2 <br />2771480 <br />E) <br />ELECTRICAL LEGEND <br />MOUNTING HEIGHTS SHOWN ARE MAXIMUM/MINIMUM <br />NOT ALL DEVICES SHOWN IN LEGEND ARE REQUIRED. <br />HANDICAPPED ACCESSIBILITY STANDARDS - THEY SHALL <br />REVIEW POWER & LIGHTING PLANS AND DETAILS FOR <br />NOT BE ALTERED WITHOUT WRITTEN AUTHORIZATION. <br />ITEMS WHICH APPLY TO THIS PROJECT. <br />AM - A®a <br />FLUORESCENT LIGHT FIXTURE, LETTER INDICATES TYPE. SEE FIXTURE <br />SCHEDULE. LOWER CASE LETTER INDICATES SWITCH (IF USED) <br />A~"" 4a <br />FLUORESCENT STRIP LIGHT, LETTER INDICATES TYPE. SEE FIXTURE <br />CAT-V CABLE OUTLET. MOUNT BOX @ 18" A.F.F. U.O.N. <br />SCHEDULE. LOWER CASE LETTER INDICATES SWITCH (IF USED) <br />OR IO <br />SURFACE MOUNTED LIGHT, LETTER INDICATES TYPE. SEE FIXTURE <br />SCHEDULE. LOWER CASE LETTER INDICATES SWITCH (IF USED) <br />I-❑ <br />DISCONNECT SWITCH <br />O B , -�- B <br />INCANDESCENT OR HID LIGHT FIXTURE, LETTER INDICATES TYPE <br />100/3/60 <br />DISCONNECT DESIGNATION (SIZE/POLES/FUSE) "NF" INDICATES <br />SEE LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />NON -FUSED; "DE" INDICATES DUAL ELEMENT FUSES. <br />Q C - Q C <br />WALL BRACKET LIGHT FIXTURE, LETTER INDICATES TYPE SEE <br />LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />EF <br />MOTOR PERMANENTLY CONNECTED WITH FLEXIBLE CONDUIT <br />(HORSEPOWER OR EQUIPMENT INDICATED) <br />NL <br />NIGHT LIGHT FIXTURE (NL) <br />THERMOSTAT. PROVIDE SINGLE GANG BOX WITH IQ" C. STUBBED <br />® X <br />EXIT LIGHT (SHADE AREA INDICATES DIRECTION) LETTER INDICATES TYPE <br />Q <br />INTO CEILING SPACE, MOUNT 60" A.F.F. U.O.N. (COORDINATE WITH <br />SEE LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />MECHANICAL DRAWINGS PRIOR TO ROUGH -IN) <br />BATTERY POWERED EMERGENCY LIGHT <br />TELEPHONE WALL OUTLET, PROVIDE SINGLE GANG BOX WITH 314" <br />CONDUIT WITH PULL WIRE AND INSULATING BUSHING STUBBED INTO <br />TRACK LIGHTING AND TRACK. FOR INFORMATION ON TRACK SEE <br />CEILING SPACE. MOUNT BOX 18" A.F.F. U.O.N. <br />LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />m <br />WALL WASHER FIXTURE. (SHADE AREA INDICATES DIRECTION) SEE <br />0 <br />COMPUTER OUTLET. MOUNT BOX @ 18" A.F.F. U.O.N. <br />LIGHT FIXTURE SCHEDULE TO CONFIRM TYPE AND MOUNTING. <br />SINGLE POLE SWITCH, LOWER CASE LETTER INDICATES LIGHTS <br />CONTROLLED. LETTER NOT SHOWN IF SELF EVIDENT. MOUNT <br />OS <br />CEILING SPEAKERS MTD. AND WIRED PER AEI MUSIC NETWORK, <br />a <br />INC. (800-274-9298) <br />48" A.F.F. U.O.N. <br />F <br />SINGLE POLE SWITCH. FAN CONTROLLER, MOUNT 48" A.F.F. U.O.N. <br />D <br />O <br />CEILING MTD. SENSOR DEVICE <br />3 <br />3-WAY SWITCH, FOR CONTROLLING LIGHTS FROM TWO DIFFERENT POINTS. <br />® <br />TWO GANG FLOOR OUTLET BOX. ONE QUADPLEX ISOLATED GROUND <br />FIRE ALARM PULL STATION: EDWARDS #SIGH 270 <br />RECEPTACLE AND ONE COMPUTER OUTLET. <br />[A--A—U <br />WIREMOLD-WALKER INFLOOR SYSTEMS. RC4 FLUSH QUAD POKE <br />MF <br />HORN/STROBE: EDWARDS #692-8A HSW <br />THRU SERIES WITH FOUR MULTIMEDIA COMMUNICATION LOCATIONS <br />AA0 <br />WIREMOLD WALLSOURCE MULTIPLE SERVICE BOX. <br />O <br />SMOKE DETECTOR: EDWARDS #ISIGA PS <br />Q <br />QUADPLEX FLOOR RECEPTACLE OUTLET. <br />O <br />HEAT DETECTOR: EDWARDS #SIGA-HRS <br />QUADPLEX RECEPTACLE OUTLET. <br />QUADPLEX RECEPTACLE OUTLET MOUNTED ABOVE COUNTER TOP U.O.N. <br />FACP <br />PANEL: SIEMEN CYRBURUS MODEL #PXL <br />OO <br />DUPLEX FLOOR RECEPTACLE OUTLET. <br />DUPLEX RECEPTACLE, MOUNT 18" AFF LION <br />EF <br />BATH ROOM FAN LIGHT (BROAN S15OL) <br />DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER HEIGHT U.O.N. <br />GFI <br />GROUND FAULT INTERRUPTER RECEPTACLE, LEVITON #6898-I, MOUNT <br />ABOVE COUNTER HEIGHT U.O.N. <br />I.G. <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362-IGI <br />MOUNTED ABOVE COUNTER HEIGHT. U.O.N. <br />ABBREVIATIONS <br />I.G. <br />DUPLEX RECEPTACLE, ISOLATED GROUND TYPE, LEVITON #5362-IGI <br />ACC-CU <br />CONDENSING UNIT NF NON -FUSED <br />MOUNT AT 18" AFF LION <br />AFF <br />ABOVE FINISH FLOOR NIC NOT IN CONTRACT <br />DUPLEX RECEPTACLE, MOUNTED ABOVE STOREFRONT WINDOWS <br />AFG <br />ABOVE FINISH GRADE NIL NIGHT LIGHT <br />A/H-AHU <br />AIR HANDLING UNIT NTS NOT TO SCALE <br />E)-- <br />SINGLE RECEPTACLE, MOUNTED AT HEIGHT NOTED ON PLANS <br />C/T <br />CURRENT TRANSFORMER OS OCCUPANCY SENSORS <br />® <br />SPECIAL PURPOSE RECEPTACLE OUTLET <br />DE <br />DUAL ELEMENT FUSE PC PULL CHAIN <br />O <br />JUNCTION BOX MOUNT IN FINISHED AREAS U.O.N.) <br />EC <br />EMPTY CONDUIT RTU ROOF TOP UNIT <br />(FLUSH <br />E/F-EF <br />EXHAUST FAN TTB TELEPHONE TERMINAL BOARD <br />LIGHTING, POWER, FACP PANELBOARD OR TELE. TERM. CABINET. <br />EG <br />EQUIPMENT GROUND TTC TELEPHONE TERMINAL CABINET <br />EM <br />EMERGENCY LIGHT TYP TYPICAL <br />MSB/MOP <br />MAIN SWITCHBOARD OR MAIN DISTRIBUTION PANEL <br />EWC <br />ELECTRIC WATER COOLER LION UNLESS OTHERWISE NOTED <br />CONDUIT CONCEALED IN WALL, BELOW SLAB, OR ABOVE CEILING. <br />EWH <br />ELECTRIC WATER HEATER VTC VIA TIME CLOCK <br />EX <br />EXISTING DEVICE TO REMAIN WP WEATHERPROOF <br />CONDUIT EXPOSED ON WALL OR CEILING. <br />FACP <br />FIRE ALARM CONTROL PANEL X EXIT LIGHT <br />GFI <br />GROUND FAULT INTERRUPTER <br />FLEXIBLE CONDUIT NOT TO EXCEED 6 FEET IN LENGTH <br />IG <br />ISOLATED GROUND <br />A-1,3 <br />CONDUIT RUN CONCEALED IN WALLS BELOW SLAB, OR CEILING SPACES. <br />LB <br />LOCK BREAKER <br />ARROWS INDICATE HOMERUN. SMALL HASHMARKS INDICATE NUMBER OF <br />HOT CONDUCTORS, AND LARGE HASHMARK INDICATES NEUTRAL. <br />SUBSCRIPT INDICATES PANEL AND CIRCUIT NUMBERS. GROUND <br />CONDUCTOR REQUIRED IN ALL CONDUITS BUT NOT INDICATED. <br />A-37:39:41 <br />SUBSCRIPT INDICATES PANEL -AND NUMBERS WITH COLONS <br />INDICATE 2 OR 3 POLE CIRCUITS. <br />NOTE: MOUNTING HEIGHTS NOTED ARE TO BOTTOM OF DEVICE SHOWN LION <br />MANUFACTURER_ SQUARE Q 'NCI.' NAME. PAN1EL. 'D3-" <br />MAIN BREAKER.- 3 PHASE <br />MAIM. LUGS: 200A 4 WIRE. PROJECT NAME::: ZEPHYR COMMONS <br />KC A I..0 - 42 1201208 VOLTS PROJECT NUMBER: 206319 <br />MOUNTED_ SURFACE FED FROG° EASTINO VVIREWAY <br />I <br />r <br />.. • r <br />REICOND r <br />O <br />a <br />- <br />r <br />CAM <br />SHOW WIND <br />HOW WtND0VV� <br />SHOW WIND <br />-� <br />HOW -WINDOW <br />owl <br />RECEPTACLESr <br />�mmom�n <br />4NMI <br />. <br />� <br />EMU <br />RECEPTACLES <br />NM <br />min <br />N= I <br />® <br />® <br />r5 TON RTU <br />TOTAL. <br />TOTALCONNECTED: <br />KVA PHASE &- 13-01 <br />CONNECTEDTOTAL <br />TOTAL <br />TOTAL KVA PHASE <br />TOTAL DEMAND ° i <br />TOTALDEMAND AMPS: <br />GENERAL <br />LIGH71NG <br />SQUAR <br />LIGHTINGLOAD: <br />.. . .' <br />RECEPTACLES <br />DEMAND LOAD IS BASED <br />ON THE LARGER O FTHE TWO: <br />COOLINGLIGHTING <br />r <br />n <br />KITCHEN EQUIPENT (K.). <br />LARGEST ' <br />OE <br />OTHER <br /># <br />KVA <br />ITES: 1 PROVIDE LOCKED CIRCUIT BREAKER 2) PROVIDE SCR RATED CIR.CI,11T BREAKER 3) VIA TENANT TIME: CLOCK 4� I�FPA 70 0S 240:83tL3) COMPLIANT <br />o� <br />0 <br />w <br />too <br />� <br />8, <br />o <br />N `* 3 <br />U <br />C, <br />U� <br />V <br />C <br />W <br />C <br />O <br />CL <br />3 <br />0 <br />rL <br />Uj <br />CU< <br />C) Q <br />M <br />(1)0LL <br />w Q <br />�a <br />z 0) <br />CN <br />w 0.M H <br />c3 <br />Cn <br />0 <br />E <br />E <br />0 <br />U <br />L <br />No <br />---+ 0 <br />C6 0 <br />m <br />0 <br />M Q <br />0 p <br />(D J <br />0 00 <br />CQQU_ <br />U) <br />}j (OEJ <br />w <br />00a>- <br />Lo <br />o �-�N <br />a <br />CU <br />n4v <br />11111117_� <br />.2) <br />_I <br />CU <br />0 <br />CCn <br />W <br />U) <br />0) <br />a <br />J <br />CU <br />L <br />w (�J <br />w W <br />w <br />U) <br />w <br />U) <br />F- <br />a <br />co <br />aD <br />oLU <br />o <br />Q <br />LlJ <br />N <br />J <br />w <br />rn <br />Z <br />o <br />I <br />0 <br />LLI <br />CD <br />CDCDw <br />tN <br />O <br />(L <br />0 <br />0 <br />0 <br />E101 <br />