Laserfiche WebLink
11 .F , T, I 1 „, 1, 1 . _ r <br />EXISTII <br />DOORI <br />WHEN <br />EGRES <br />=165P <br />i D-E) i D-D i D-13 <br />D-C ii DB i <br />Life Safety Plan <br />N 0-- <br />SCALE: 1/8 =1-0 <br />ALL PENETRATIONS IN FIRE RATED <br />WALLS SHALL BE SEALED SO AS <br />TO MAINTAIN THE MIN. REQUIRED <br />Code Information <br />FIRE RATING. RE: UL DETAILS <br />JURISDICTION AUTHORITY <br />THE EXISTING DOOR HARDWARE <br />CITY OF ZEPHYRHILLS 3 SIGNED & SEALED SETS FOR PERMIT <br />ON THE EXISTING FRONT AND REAR <br />5335 8TH STREET (813) 780-0020 - PHONE <br />DOORS MEETS ADA REQUIREMENTS <br />ZEPHYRHILLS, FL 33542 (813) 780-0021- FAX <br />EXISTING 36' FRONT DOOR <br />ADOPTED CODES: <br />(33- CLEAR WHEN DOOR IS OPEN) <br />EGRESS CAPACITY =165 PEOPLE <br />BUILDING: FLORIDA BUILDING CODE, BUILDING - 2007 (W/ 2009 AMENDMENTS) <br />FIRE: FLORIDA FIRE PREVENTION CODE - 2007 (WI 2009 AMENDMENTS) <br />(CHAPTER 36 - NFPA 1 & NFPA 101 WI STATE FIRE MARSHAL AMENDMENTS) <br />EXISTING KNOX BOX <br />PLUMBING: FLORIDA BUILDING CODE, PLUMBING - 2007 (W/ 2009 AMENDMENTS) <br />MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL - 2007 (WI 2009 AMENDMENTS) <br />ELECTRICAL: FLORIDA BUILDING CODE, BUILDING - 2007 (WI 2009 AMENDMENTS) <br />(CHAPTER 27 - NFPA 70, NATIONAL ELECTRIC CODE) <br />FUEUGAS: FLORIDA BUILDING CODE, FUEUGAS - 2007 (W/ 2009 AMENDMENTS) <br />ACCESSIBILITY: FLORIDA BUILDING CODE, BUILDING - 2007 (WI 2009 AMENDMENTS) <br />(CHAPTER 11 - FLORIDAACCESSIBILITY CODE FOR BUILDING CONSTRUCTION). <br />ENERGY: FLORIDA BUILDING CODE, BUILDING - 2007 (WI 2009 AMENDMENTS) <br />(CHAPTER 13 - FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION). <br />EXISTING FRONT FRAMED WALL <br />HAS A 1 HOUR FIRE RATING. ALL <br />WORK RELATED TO THE FRONT <br />BUILDING AND CONSTRUCTION DATA <br />WALL SHALL BE PERFORMED SO <br />AS TO MAINTAIN THE WALL'S <br />OCCUPANCY CLASSIFICATION (FBC 309) GROUP M - MERCANTILE <br />EXISTING FIRE RATING. <br />CONSTRUCTION TYPE (FBC TABLE 601) TYPE II-B, FULLY SPRINKLERED <br />MAXIMUM HEIGHTAND AREA (FBC TABLE 503) <br />MAXIMUM HEIGHT 55'-0" - FOUR STORIES <br />ACTUAL HEIGHT 35'-0" - ONE STORY <br />MAXIMUM AREA 12,500 SF <br />ACTUALAREA 8,600 SF <br />EXISTING TELEPHONE <br />STOREFRONT SYSTEM <br />CONDUIT STUB UP <br />D D NEW RESTROOMS. RE: <br />I I <br />W/ 3' X T DOOR (TYPE A) <br />TO REMAIN AS IS <br />GENERAL NOTES 3 & 4 <br />I I <br />TO REMAIN AS IS <br />NEW ELECTRICAL PANEL <br />I <br />NEW HOLLOW CORE DOORS. <br />J <br />z <br />AWNING ABOVE <br />I I <br />ADDED AT LOCATION OF <br />(TYPE C) RE: GENERAL NOTE 5 <br />,� <br />0 <br />I <br />- <br />(SHOWN DASHED) <br />ILJ <br />EXISTING CONDUIT STUB <br />I <br />w <br />I <br />TO REMAIN AS IS <br />UP. RE: ELECTRICAL <br />I <br />m <br />W <br />z <br />w <br />c� <br />NO FINISH ADDED TO CMU a "' = a <br />EXISTING i WALL OUTSIDE OF RESTROOM o o <br />DOWNSPOUT i z co <br />- D-4 <br />TO REMAIN AS IS <br />N -E i -D i -C 4 D-B i <br />2 Floor Plan <br />SCALE: 1/8" =1'-0" <br />NEW EXHAUST FANS NEW HVAC SUPPLYAIR NEW 2 X 4 CEILING NEW 2' X 4'ACOUSTICAL TILE EXISTING SCONCE <br />IN RESTROOM DIFFUSER MOUNTED MOUNTED LIGHT CEILINGS MOUNTED AT 10'-0" LIGHT FIXTURE <br />CEILINGS. RE: M101 IN CEILING. RE: M101 FIXTURES. RE: E101 ABOVE FLOORS IN RESTROOMS TO REMAIN AS IS <br />AND IN MAIN ROOM ,- <br />-----------� D-5 i <br />O O ® O O <br />04 <br />NEW EXIT LIGHT <br />FIXTURE. RE: E101 <br />EXISTING SCONCE <br />LIGHT FIXTUREIrl Ol <br />Q <br />TO BE REWIRED. Lj ® 0.01 ® 0 ® ® EXISTING SCONCE <br />RE: E101LIGHT FIXTURE <br />TO REMAIN AS IS <br />EXISTING RAIN HOODS D-4 <br />OVER REAR DOORS <br />TO REMAIN AS IS <br />NEW EXIT LIGHT <br />FIXTURE. RE: E101 <br />EXISTING AWNING <br />ABOVE STOREFRONT <br />EXISTING SCONCE TO REMAIN AS IS <br />LIGHT FIXTURE <br />TO BE REWIRED. O ® O 0 0 EXISTING SCONCE <br />RE: E101 <br />LIGHT FIXTURE <br />TO REMAIN AS IS <br />-----------� D-3 i <br />NEW WALL MOUNTED NEW HVAC RETURN AIR EXISTING 5 TON RTUS NEW SPRINKLER <br />EMERGENCY LIGHT GRILLE MOUNTED ON ROOF ABOVE HEAD MOUNTED <br />FIXTURE. RE: E101 IN CEILING. RE: M101 RE: M101 & El01 IN CEILING <br />N i D-E i i D-D i i D-C b D-B <br />Y 3 Reflected Ceiling Plan <br />SCALE: 1/8=1-0 <br />FLOOR PLAN GENERAL NOTES: <br />1. NEW 6" DEMISING WALLS SHALL HAVE 5/8" SHEATHING BOTH SIDES <br />AND R19 BATT INSULATION. FRAMING, SHEATHING, AND INSULATION <br />SHALL EXTEND TO THE UNDERSIDE OF THE ROOF DECK ABOVE. NEW <br />6" DEMISING WALLS SHALL PROVIDE A MIN.1 HOUR FIRE RATING. <br />SHEATHING SHALL BE PAINT READY. <br />2. EXISTING STRUCTURAL COMPONENTS OF REAR MASONRY WALL TO <br />REMAIN AS IS. ON THE INTERIOR SIDE OF THE WALL, INSIDE OF THE <br />NEW RESTROOM ONLY, 1/2" MOISTURE RESISTANT GYP BOARD <br />SHEATHING SHALL BE ADDED OVER 1.5" FURRING STRIPS @ 24" OC <br />AND 1.5" RIGID INSULATION. FURRING, SHEATHING, AND INSULATION <br />SHALL TERMINATE 10'-6"AFF. THE GYP BOARD SHEATHING SHALL <br />RECEIVE ENAMEL PAINT. THE REST OF THE REAR WALL SHALL BE <br />LEFT AS EXPOSED MASONRY WITH NO FINISH. <br />3. NEW RESTROOM WALLS SHALL BE EITHER 6" OR 3-5/8" FRAMING AS <br />SHOWN. 6' WALLS SHALL RECEIVE R19 BATT INSULATION. 3-5/8" <br />WALLS SHALL RECEIVE R11 BATT INSULATION. ALL WALLS SHALL <br />HAVE 1/2' PAINT READY GYP BOARD ON THE OUTSIDE. ALL WALLS <br />SHALL HAVE 1/2" MOISTURE RESISTANT GYP BOARD WITH ENAMEL <br />PAINT ON THE INSIDE. ALL FRAMING, SHEATHING, AND INSULATION <br />SHALL TERMINATE 10-6 AFF. THE RESTROOM SHALL HAVE VCT <br />FLOORING AND A 6' VINYL BASE ON THE INSIDE OF ALL WALLS. <br />4. BATHROOM ACCESSORIES SHALL INCLUDE TOILET PAPER DISPENSER, <br />PAPER TOWEL DISPENSER, SOAP DISPENSER, MIRROR, AND GRAB <br />BARS AS REQUIRED BY CODE. ALL ACCESSORIES SHALL BE ADA <br />COMPLIANTAND SHALL BE STAINLESS STEEL. <br />5. BATHROOM DOORS SHALL BE 1-3/4" X 36' X 80" PRE -HUNG HOLLOW <br />CORE DOORS. THE EXTERIORS SHALL BE PAINT READY. THE INTERIORS <br />SHALL RECEIVE ENAMEL PAINT. EACH HARDWARE SET SHALL INCLUDE 3 <br />HINGES, 3 SILENCERS, 1 DOOR STOP, 1 CLOSER, AND 1 "PASSAGE LATCH" <br />LOCKSET. THE DOORS SHALLALSO RECEIVE ADAACCESSIBLE SIGNAGE <br />AS REQUIRED BY CODE. RE: A102-10 FOR COMPLETE DOOR INFO. <br />Z. CONTRACTOR TO FIELD VERIFYALL DIMENSIONS AND CONDITIONS. <br />7. GC MAY SUBMITALTERNATE DESIGN FOR STUD GAUGE & SPACING. <br />IFAN ALTERNATE DESIGN IS PROPOSED, THE GC MUST SUBMIT <br />INFORMATION TO THE OWNER & THE ARCHITECT FOR APPROVAL <br />PRIOR TO ORDERING ANY MATERIALS. THE SUBMITTAL MUST INCLUDE <br />STRUCTURAL INFORMATION VERIFYING THAT THE DESIGN IS ADEQUATE <br />FOR THE WALL'S REQUIRED HEIGHT, LOADING, AND DEFLECTION. THE <br />SUBMITTAL MUST ALSO INCLUDE PRICE COMPARISON INFORMATION. <br />RE: WALL TYPE DETAILS ON THIS SHEET. <br />CEILING PLAN GENERAL NOTES: <br />1. ALL NEW CEILINGS SHALL BE 2' X 4' ACT MOUNTED <br />AT 10'-0"AFF WITH NO INSULATION. <br />2. ON THE FRONT OF THE BUILDING, THE EXISTING <br />DECORATIVE SCONCE FIXTURES SHALL REMAIN WIRED <br />AS IS TO THE EXISTING HOUSE PANEL. <br />3. EXISTING REAR WALL MOUNTED LIGHT SHALL BE WIRED <br />TO THE NEW TENANT PANEL VIAA NEW LIGHT SWITCH. <br />4. ALL NEW EXITAND EMERGENCY LIGHTS SHALL BE <br />WIRED TO THE NEW TENANT PANEL. <br />5. ALL NEW 2 X 4 FLUORESCENT LIGHT FIXTURES SHALL <br />BE WIRED TO THE NEW TENANT PANEL. <br />6. THE 5 TON RTUS ARE EXISTING AND SHALL REMAIN. ALL NEW <br />SUPPLY DIFFUSERS, RETURN GRILLES, AND EXHAUST FANS <br />SHALL BE TIED INTO THE EXISTING RTUS VIA NEW DUCTWORK. <br />7. THE EXISTING RTUS AND THE NEW EXHAUST FANS SHALL <br />BE WIRED TO THE NEW TENANT PANEL. <br />8. THE FIRE SPRINKLER HEAD LOCATIONS SHOWN ON THIS <br />PLAN ARE DIAGRAMMATIC ONLY. THE EXACT SPRINKLER <br />HEAD LAYOUT SHALL BE DETERMINED BY THE FIRE <br />SPRINKLER SUBCONTRACTOR'S SPECIALTY ENGINEER <br />DURING THE DESIGN OF HIS SHOP DRAWINGS. <br />9. THE EXISTING SPRINKLER HEADS SHALL BE TURNED <br />DOWN & REPOSITIONED AS NEEDED TO COORDINATE <br />WITH HVAC, ELECTRICAL, AND PLUMBING. <br />SECTION <br />EXISTING MASONRY <br />WALL TO REMAIN AS <br />EXISTING COREFILL <br />FOAM INSULATION T <br />REMAIN AS IS <br />EXISTING EXTERI( <br />FINISHES TO REM, <br />AS THEY ARE <br />EXISTING EXTERI( <br />SIDEWALKS AND <br />ADJACENTLANDS <br />AREAS TO REMAII <br />AS THEY ARE <br />PLAN VIEW <br />SECTION <br />FIRE RATING REQUIREMENTS <br />FBC TABLES 601 & 602 - FIRE RATING REQUIREMENTS FOR CONSTRUCTION TYPE it-B <br />ELEMENT REQUIRED FIRE RATING <br />STRUCTURAL FRAME <br />0 HR <br />LOAD BEARING EXTERIOR WALLS <br />2 HR <br />(F.S.D. < 6) <br />LOAD BEARING EXTERIOR WALLS <br />1 HR <br />PROVIDED AS <br />(F.S.D. BETWEEN 5' & 10-) <br />PART OF SHELL <br />LOAD BEARING EXTERIOR WALLS <br />0 HR <br />(F.S.D. > 10') <br />ROOF CONSTRUCTION <br />0 HR <br />FLOOR CONSTRUCTION <br />0 HR <br />NON BEARING INTERIOR WALLS <br />0 HR <br />F.S.D. IS FIRE SEPARATION DISTANCE <br />FBC 708 - OTHER FIRE RATING REQUIREMENTS <br />TENANTS SHALL BE SEPARATED BY MIN 1 HR FIRE BARRIER <br />FBC 803 - CLASSIFICATION OF INTERIOR FINISHES <br />FBC 803.1 - FLAMESPREAD <br />A-FLAMESPREAD 0-25, SMOKE DEV. 0-450 <br />CLASSIFICATIONS <br />B-FLAMESPREAD 26-75, SMOKE DEV. 0-450 <br />C-FLAMESPREAD 76-200, SMOKE DEV. 0450 <br />TABLE 803.5 - REQUIRED <br />EXIT PASSAGEWAYS - CLASS B <br />FLAMESPREAD FOR MERCANTILE <br />EXITACCESS CORRIDORS - CLASS C <br />OCCUPANCY (SPRINKLERED) <br />ROOMS & OTHER SPACES - CLASS C <br />FIRE PROTECTION SYSTEMS, FBC 900 <br />FBC 903 - SPRINKLERS <br />DESIGN STANDARD NFPA 13 AS <br />MODIFIED BY NFPA231 & NFPA231C <br />FBC 903.2.6 - GROUP M REQUIREMENTS <br />FIRE SPRINKLERS REQUIRED IN GROUP <br />M WHEN GROSS AREA > 12,000 SF <br />(PROVIDED) <br />FBC 906 - PORTABLE FIRE EXTINGUISHERS <br />EACH TENANT SPACE IS PROVIDED WITH <br />APORTABLE FIRE EXTINGUISHER <br />FBC 907.2.7 - FIRE ALARMS <br />FIRE ALARMS REQUIRED IN GROUP M <br />WHEN OCCUPANT LOAD > 500 <br />(PROVIDED) <br />Existing Masonry Wall <br />EXISTING MASO Y WALL WITH FRAM G AND <br />SHEATHING ADDED TO THE INTERIOR SIDE. <br />TO BE USED ALONG REAR WALL INSIDE THE RESTROOM. <br />SCALE: 1 1/2" = V-0' <br />1/2" GYP BOARD B <br />SIDES OF FRAMIN <br />FRAMING, SHEATF <br />& INSULATION TO <br />TERMINATE 6"AB( <br />CEILING. <br />PLAN VIEW <br />New 6" Metal Stud Wall <br />NO FIRE RATING <br />TO BE USED FOR RESTROOM WET WALL. <br />SCALE: 1 1/2" = V-0' <br />SECTION <br />THIS BUILDING HAS A FULL FIRE SPRINKLER SYSTEM. THE CONTRACTOR SHALL <br />PREPARE SHOP DRAWINGS FOR REVISIONS TO THE SYSTEM AS NEEDED FOR THE <br />BUILDOUT OF SPACE D3-D4. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED <br />SHOP DRAWINGS TO THE LOCAL JURISDICTION AS REQUIRED FOR PERMITTING. <br />THIS BUILDING HAS A FULL FIRE ALARM SYSTEM. THE CONTRACTOR SHALL <br />PREPARE SHOP DRAWINGS FOR REVISIONS TO THE SYSTEM AS NEEDED FOR THE <br />BUILDOUT OF SPACE D3-D4. THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED <br />SHOP DRAWINGS TO THE LOCAL JURISDICTION AS REQUIRED FOR PERMITTING. <br />MEANS OF EGRESS, FBC 1000 <br />OCCUPANCY CLASSIFICATION MERCANTILE (SPRINKLERED) <br />FLOOR AREAS AT GRADE <br />FBC 1004.1.1 - OCCUPANT LOAD 1 PERSON / 30 SF (GROSS) <br />FBC 1005.1- EGRESS WIDTH / PERSON 0.2" / PERSON <br />FBC 1008.1.1 - MIN. CLEAR DOOR OPENING 32" MIN <br />FBC 1016.1 - MAX. TRAVEL DISTANCE 250' MAX <br />FBC 1019.1- MIN. NUMBER OF EXITS 2 WHEN OCCUPANT LOAD 1-500 <br />EGRESS WIDTH # OF EXITS <br />TENANT GROUP SIZE (SF) OCCUR LOAD (REQ'D I PROV'D) (REQ'D / PROV'D) <br />D3-D4 M 21800 1/30 94 18.8" / 66' 2/2 <br />FBC PLUMBING 403 - MINIMUM FACILITIES <br />OCCUPANCY - MERCANTILE (1 PERSON PER 30 SF GROSS) <br />PFBC TABLE 403.1 - # OF FIXTURES REQUIRED PER PERSON <br />MEN'S WATER CLOSETS 1 / 500 BATHTUB / SHOWER NOT REQUIRED <br />WOMEN'S WATER CLOSETS 1 / 500 DRINKING FOUNTAINS 1 / 1,000 <br />LAVATORIES 1 / 750 SERVICE SINK NOT REQUIRED <br />SPACE SIZE (SF) LOAD FIXTURES (REQUIRED / PROVIDED) <br />D3-D4 2,800 94 MEN'S WOMEN'S SHARED <br />WC LAV WC LAV DF <br />1/1 1/1 1/1 1/1 1/2 <br />1 1/2' RIGID - T; <br />INSULATION <br />EXISTING ROOF DECK <br />FURRING, SHEATHING, <br />& INSULATION TO RUN <br />FROM FLOOR SLAB CONTINUOUS STUD AT <br />TO 6" ABOVE CEILING TOP OF WALL <br />5/8" GYP BOARD BOTH <br />SIDES OF FRAMING. MTL STUD FRAMING <br />SUSPENDED CEILING FRAMING, SHEATHING, RE: CEILING PLAN & INSULATION TO 600S125-43 @ 24" OC <br />TERMINATE AT UNDERSIDE <br />OF ROOF STRUCTURE ABOVE. <br />5/8" GYP BOARD OVER R-19 SOUND BATTS <br />1 1/2" Z-FURRING WALL CONSTRUCTION SHALL <br />CHANNELS @ 24" OC BE CONSISTENT WITH UL <br />MAX SPACING DETAILS U419, HW-S-0001, & CONTINUOUS STUD <br />W-L-1001 TO PROVIDE AMIN. TRACK 60OT125-43 <br />1 HOUR FIRE RATING. <br />6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY 6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY <br />NEW CONCRETE EXISTING CONCRETE <br />FLOOR SLAB IN �` <br />AREA OF EXISTING FLOOR SLAB TO <br />SLAB LEAVE OUT REMAIN AS IS <br />CONTINUOUS STUD AT <br />TOP OF WALL <br />MTL STUD FRAMING <br />60OS125-43 @ 24- OC <br />LAY -IN CEILING, RE: RCP <br />R-19 SOUND BATTS <br />CONTINUOUS STUD TRACK <br />60OT125-43 <br />6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY <br />EXISTING CONCRETE <br />FLOOR SLAB TO <br />REMAIN AS IS <br />PLAN VIEW <br />New 6" Metal Stud Wall <br />1 HOUR FIRE RATING <br />TO BE USED FOR BOTH TENANT DEMISING WALLS <br />SCALE: 1 1/2" =1'-d' <br />SECTION <br />1/2" GYP BOARD BOTH <br />SIDES OF FRAMING. <br />FRAMING, SHEATF""" <br />& INSULATION TO <br />TERMINATE 6' AB( <br />CEILING. <br />PLAN VIEW <br />New 3 5/8" Metal Stud Wall <br />NO FIRE RATING <br />TO BE USED FOR THE OTHER RESTROOM WALLS <br />SCALE: 1 1/2"= V-0' <br />CONTINUOUS STUD AT <br />TOP OF WALL <br />MTL STUD FRAMING <br />362S125-43 @ 24" OC <br />LAY -IN CEILING, RE: RCP <br />R-11 SOUND BATTS <br />CONTINUOUS STUD TRACK <br />362T125-43 <br />6" VINYL BASE ON INSIDE <br />OF BATHROOM ONLY <br />EXISTING CONCRETE <br />FLOOR SLAB TO <br />REMAIN AS IS <br />OC) <br />O <br />VJ <br />U <br />�� <br />!r <br />M O <br />w a <br />W <br />•� <br />o <br />>o <br />Qo <br />V <br />cooaj <br />Cn <br />O <br />O <br />U <br />L <br />C_ <br />CDI <br />N � <br />J - <br />�' <br />Qm <br />Y = <br />�a <br />0 0 <br />J <br />Co <br />U <br />ICU <br />vJOJ <br />� CO <br />w <br />Z <br />CU <br />LC) <br />W LU <br />~,N - <br />a <br />Cn <br />_ICU <br />co <br />o - <br />CV <br />w U = <br />J <br />w <br />w Cv0 - <br />x <br />C _ <br />r <br />�E <br />s <br />w <br />CD <br />of <br />w <br />a <br />o <br />= <br />o <br />Q <br />w <br />N <br />J <br />w <br />Z <br />M <br />0CD <br />i <br />0 <br />_ <br />w <br />o <br />z <br />`1 <br />L <br />m <br />o <br />= <br />a <br />o <br />o <br />0 <br />Al 01 <br />