EXISTING BLDG SANITARY LINE (VARIFY) <br />SANITARY <br />PLAN <br />EXISTING <br />30 GALLON <br />WATER HEATER <br />WALL MOUNT <br />1" DRAIN LINE <br />XISTING <br />COMP SINK <br />RAIN LINE <br />TO 3 COMP FLOOR SINK <br />1/4 1$ = 1'-0" <br />PLAN <br />NOTES <br />EXTEND AND <br />CONNECT TO EXISTING <br />1 UNDERGROUND <br />SANITARY PIPING. <br />FIELD VERIFY <br />EXISTING PIPE LOCATION. <br />O EXTEND AND <br />CONNECT TO EXISTING VENT PIPE. <br />FIELD VERIFY <br />EXISTING PIPE LOCATION. <br />O EXTEND AND <br />CONNECT TO 2" DOMESTIC WATER LINE. <br />FIELD VERIFY <br />EXISTING PIPE LOCATION. <br />® EXISTING 30 <br />GAL ELECTRIC WATER TANK. <br />G.I. <br />CALCULATION <br />FBC — PLUMBING 2017 <br />TABLE 1003.5.1 <br />— SIZING FORMULAS FOR GREASE INTERCEPTOR <br />PRIVATE SEWAGE DISPOSAL SYSTEM <br />(S) x (GS) <br />x [HR/12 x (LE)] = EFFECTIVE CAPACITY OF <br />GREASE INTERCEPTOR IN <br />GALLONS <br />19 SEATS <br />x 10 GAL. (fast food service) x [12HR/12HR x (1)] _ <br />190 GALS. <br />REQUIRED <br />TANKSIZE: 190 GALLON GREASE INTERCEPTOR <br />EXISTING <br />TANK SIZE: FIELD VERIFY TANK SIZE AND <br />LOCATION <br />tK <br />4"0 <br />VENT <br />PLUMBING LEGEND <br />SANITARY WASTE PIPE <br />GREASE WASTE PIPE <br />VENT PIPING <br />COLD WATER PIPING <br />HOT WATER PIPE <br />WALL CLEANOUT <br />FLOOR CLEANOUT <br />VENT THRU ROOF <br />GATE VALVE <br />c c <br />H H <br />© WCL <br />O FC <br />JIL <br />-0E- <br />SCOPE OF WORK: <br />PLUMBING CONTRACTOR TO FIELD VARIFY <br />LOCATION OF PROPOSED NEW & EXISINTG <br />EQUIPMENT AND PLACEMENT, PRIOR BID & <br />TO START OF WORK. ALL WORK IS SUBJECT <br />TO EXISTING FIELD CONDITIONS THAT MAY <br />ALTER THE DESIGN OF THIS PROJECT. <br />\ :Ak c �q <br />s <br />3"0 <br />VENT <br />EXISTINGWC <br />\ \� <br />MEN 1 ' Z)IIN \ \ <br />V \ <br />W.C.O. \ <br />EXISTING <br />LAV <br />Co � \\ <br />I2"0 / \ <br />NEW \ / EXISTING 3"0 \\ \ <br />VENT \ <br />WOMEN WC e�k/ / VERIFY LOCATION AND SIZE OF \\ \ <br />GREASE INTERCEPTOR EXIS11N G' <br />NEW P�j 3"0 \ <br />LAV ?�F`�L �, Psi EXISTING\ <br />6 t` G19Z MOP \\ <br />SINK <br />CO O <br />2"0 <br />�-� EXISTING <br />30 GALLON <br />WATER HEATER <br />WALL MOUNT <br />NEW <br />BATCH <br />MACHINE <br />�� <br />WALL MOUNT <br />PLATFORM <br />NEW <br />b', <br />�Q�' <br />BATCH <br />MACHINE �` ��4 <br />t� <br />1"0 PVC <br />DRIP LINE <br />\�J4'IF= <br />AIR GAP <br />V& <br />�•'��� <br />NEW / <br />?; <br />�$ <br />3ECOMP SINK <br />W/EXISTING H/C LINES <br />HAND4'F�i� <br />EXISTING <br />` SINK ?4 __y <br />HAND <br />SINK <br />MECH,4 2 i <br />VENT i <br />. r <br />NEW <br />DIPPING <br />WELL <br />/ <br />1' <br />EXISTING <br />4"0 NEW / <br />F.C.O. DIPPING ,L <br />\ WELL <br />SANITARY RISER <br />NOT TO SCALE <br />r O� <br />PLUMB'G FIXTURE SPECIFICAT'N <br />FIXTURE NUMBERS ARE AMERICAN STANDARD. SIMILAR FIXTURES BY ELJER OR KOHLER WILL BE CONSIDERED EQUAL <br />DES'N <br />DESCRIPTION <br />MANUFACTURER <br />CAT NO. <br />TRIM <br />SUPPLY <br />WASTE <br />VENT <br />W C <br />/ <br />WATER CLOSET FLOOR <br />AMERICAN <br />CADET <br />WIDE ANGLE <br />1 2" CW <br />/ <br />4" <br />2" <br />MOUNTED FLUSH <br />STANDARD <br />2292.100 <br />WHEEL STOP <br />LAV <br />LAVATORY. WALL <br />AMERICAN <br />PENLYL <br />CHICAGO <br />1 /2" CW <br />2" <br />11 /2" <br />UNG 8" HC <br />STANDARD <br />0373-027 <br />FAICET 408A-665 <br />& HW <br />WH <br />WATER HEATER <br />FD <br />FLOOR DRAIN <br />ZURN <br />FD2321-PO3 <br />STAINLESS <br />_ <br />3" <br />2" <br />OR EQUAL <br />STEEL COVER <br />FS <br />FLOOR SINK <br />ZURN <br />FD2376 OR <br />STAINLESS <br />_ <br />3" <br />2" <br />EQUAL <br />STEEL COVER <br />FC <br />FLOOR CLEANOUT <br />ZURN <br />CO2500 OR <br />BRASS COVER <br />- <br />3" <br />2" <br />EQUAL <br />MS <br />MOP SINK <br />ZURN <br />Z1996-24 <br />STAINLESS <br />1/2" CW <br />2" <br />11 2" <br />OR EQUAL <br />STEEL COVER <br />& HW <br />SF <br />SERVICE FAUSET <br />ZURN <br />Z1996-SF <br />STAINLESS <br />1 /2" CW <br />- <br />- <br />OR EQUAL <br />STEEL COVER <br />& HW <br />PT <br />PRIMER TRAP <br />ZURN <br />#Z-1000 <br />BRASS <br />- <br />- <br />- <br />OR EQUAL <br />f� <br />S <br />hv" t <br />iy V .- <br />NOTE: ALL PLUMBING WORK TO CONFORM TO 7TH EDITION <br />FLORIDA BUILDING CODE 2020 — PLUMBING. <br />1.) ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH <br />APPICABLE LOCAL CODES, RULES AND ORDINANCES. <br />2.) PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE <br />THEMSELF WITH ALL EXISTING CONDITIONS. <br />3.) ALL MATERIALS SHALL BE NEW. <br />4.) ALL WORK SHALL BE PERFORMED BY A UCENSED PLUMBING CONTRACTOR IN A FIRST <br />CLASS WORKMALIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. <br />ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION <br />SHALL BE A PART OF THIS CONTRACT. <br />5.) REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR <br />PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION <br />OF THE WORK. <br />6.) PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, <br />INSPECTION <br />AND TEST, PLUMBING CONTRACTOR TO OBTAIN PERMIT AND APPROVED SUBMITTLES <br />PRIOR TO BEGINING WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST <br />BE PRESENT FOR <br />ALL INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES. <br />7.) DRAWINGS ARE DIAGRAMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, <br />PIPING, EQUIPMENT, ETC. <br />8.) ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE <br />WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPTANCY TO ENGINEER / <br />ARCHITECT PRIOR TO BEGINING CONSTRUCTION. <br />9.) VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERTS OF ALL EXISTING UTILITIES <br />PRIOR TO BEGINING OF CONSTRUCTION. ADVISE ENGINEER/ARCHITECT OF ANY <br />DISCREPANCIES. <br />10.) WATER PIPING ABOVE & ALOW GRADE SHALL BE CPVC. <br />11.) SOIL, WASTE, VENT AND RAINWATER PIPING SHALL BE CAST IRON OR P.V.C. <br />PVC MAY NOT BE USED THRU RATED ASSEMBUES OR IN PLENUMS. <br />12.) ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSiBLE STOPS AN <br />APPROPRIATLEY MARKED ACCESS PANELS, COORDINATE LOCATIONS WITH THE GENERAL <br />CONTRACTOR PRIOR TO INSTALLATION, <br />13.) FURNISH AND INSTALL APPROVED AIR CHAMBERS AT EACH PLUMBING FIXTURE GROUP <br />AS PER CODE AND WITH GOOD ENGINEERING PRACTICE. <br />14.) DIELECTRIC COUPLING ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND <br />EQUIPMENT CONNECTIONS EXCEPT AT WATER HEATER AS PER CODE. <br />)15.) DISINFECTION OF WATER LINES IS REQUIRED BY FPC 610 <br />116.) ALL ARE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED <br />FROM FIRE, SMOKE AND WATER PENETRATIONS BY FILLING VOIDS BETWEEN PIPE AND <br />WALL, FLOOR SLEEVES WITH FIRE RATED FOAM TO ACHIEVE THE SAME RATING AS <br />WALLS OR FLOORS AS PART OF THE PLUMBERS WORK. <br />17.) LUMBING CON CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHiP <br />REE FROM DEFECTS FOR A PERIOD OF NO LESS THAN (1) ONE YEAR FROM THE DATE OF <br />ACCEPTANCE BY OWNER CORRECTION OF ANY DEFECTS SHALL BE COMPLETED <br />WITHOUT ADDITIONAL CHARGE WITHIN 72 HRS OF NOTiFiCAT10N AND SHALL INCLUDE <br />REPLACEMENT OR REPAIR OF ANYM OTHER PHASE OF INSTALLATION WHICH MAY HAVE <br />BEEN DAMAGED. <br />18.) PR ViDE CHROM PLATED COMBINATION COVER PLATE AND CLEANOUT PLUG OR <br />ACCESS <br />PANEL FOR ALL WALL CLEANOUTS, <br />1 .) NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES <br />WHERE USED AS RETURN AIR PLENUMS. <br />20.) NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR <br />EQUIPMENT ROOMS. <br />21.) CONDENSATE DRAIN LINES TO BE RUN UNDER SLAB IN P.V.C. SCH40 PIPE AND STUBBED <br />OUT OF WALL TO UNIT. TIE IN OF A/C TO BE BY OTHERS. P.V.C. PIPING WITh 1/2" THICK <br />ARAFLEX INSULATION MAY BE USED IN LOCATIONS WHERE ALLOWED BY LOCAL CODES. <br />SEE PLUMBING DRAWINGS FOR SIZE AND LOCATION OF PIPING. P.V.C. WILL BE MIN. <br />SCHEDULE 40 PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR <br />INDIVIDUAL SHUT OFF. CONDENSATE REMOVEAL SHALL COMPLY WITH SECTION 307 OF FBCM <br />22.) WATER PIPING INSULATION SHALL BE 10 THICK ARMAPLEX INSTALLED IN ACCORDANCE WITH <br />MANUFACTURES INSTRUCTIONS FOR ALL HOT WATER PPING. WHERE DOMESTIC WATER <br />TEMPERATURES CAN CAUSE SWEATING ALL COLD WATER PIPING SHALL BE INSULATED <br />WITH 1 /20 THICK ARMAPLEX INSULATION. <br />23.) STUDOR MINI/MAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO VENT <br />PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL CODES, <br />INSTALLATION SHALL BE AS PER MANUFACTURERS RECOMMENDATIONS, <br />SAMUEL OLMEDO <br />ARCHITECT <br />FL. REG. AR0015027 <br />TEL. 407. 967. 3109 <br />soarcht @ yahoo.com <br />P.O. BOX 784825 <br />WINTER GARDEN, FL. 34778 <br />PERMIT SET <br />REVISIONS: <br />NO DATE DESCRIPTION <br />3-25-12 JII CORP <br />INSTRUMENTS OF SERVICE OWNERSHIP <br />ALL REPORTS, PLANS, SPECIFICATIONS, <br />COMPUTER FILES, FIELD DATA, NOTES <br />INSTRUMENTS PREPARED BY THE <br />AND OTHER DOCUMENTS AND RELATED <br />INSTRUMENTS PREPARED BY THE <br />ARCHITECT OR CONSULTANTS AS <br />INTRUMENTS OF SERVICE SHALL REMAIN <br />THE PROPERTY OF THE ARCHITECT OR <br />CONSULTANT. THE ARCHITECT AND OR <br />THE CONSULTANT SHALL RETAIN ALL <br />COMMON LAW, STATUTORY AND OTHER <br />RESERVED RIGHTS, INCLUDING THE <br />COPYRIGHT THERETO. <br />RESTAURANT <br />INTERIOR BUILD —OUT <br />FOR: <br />JEREMIAH'S <br />TALIAN ICE <br />7936 GALL BLVD <br />ZEPHYRHILLS, FL 33541 <br />SHEET <br />SANITARY PLAN AND RISER <br />Pi <br />N <br />0 <br />Ln <br />0 <br />0 <br />