Laserfiche WebLink
INDEX U + ,, (_Sc <br />LOT 126 - PULSAR'OR' 5 OP <br />1. <br />FL0.1SLAB J <br />FL1.12 FLOOR PLAN *Or <br />FL 1.12.1 ,r <br />PLOGR PLAN OPTIONS <br />FL4.12 <br />SECTIONS <br />FL 5.12 ELEVATIONS D' <br />LEVATIONSO' <br />2. <br />FL5.13.11 ROOF PLAN'O' 3. <br />FL 6.12 UTILITY PLANS'Cr I ( ^ 4. <br />LOT 127 - PULSAR 'LR' `e p�(///rJ 5_ <br />FL 0.1.8 SLAB PLAN L' I'�//; �I 6- <br />FL /.9 FLOOR PLAN �� ✓ G rr I / 7, <br />FL 1.9.1 FLOOR PLAN OPTIONS 111 <br />FL 4.9 SECTIONS 6 <br />FL 5.9 ELEVATIONS 1: O lp <br />FL 5.133 ROOF PLAN'L' <br />FL 6.9 UTILITY PIANS'L' <br />b 9. <br />LOT 128 - PULSAR'KR' 'zA 10. <br />FL 1,8 SLAB PLAN N' f l <br />FL 1.8 FLOOR PLAN N' <br />FL 1.8.1 FLOOR PLAN OPTIONS <br />FL 4.8 SECTIONS <br />FL 5.8 ELEVATIONS IV ' 1J <br />FL .13.7 ROOF PLANK' 6 <br />FL .8 UTILITY PLANS YC t <br />LOT 129 - PULSAR'A' <br />FL 0.1 SLAB PLAN'A' -T-� �,f�Y V <br />FL 1.1 FLOOR PLAN1 /f 7 " 12. <br />FL 1.1.1 FLOOR PLAN OPTIONS I V <br />FL 4.1 SECTIONS <br />FL5.1 ELEVATIONS'A' 13. <br />FL 5.13 ROOF PLANN ` <br />FL6A UTILITY PLANS'A' 14, <br />LOT 130 - PULSAR 'MR' <br />FL 0.1.9 -SLAB PLAN M' <br />FL 1.10 FLOOR PLAN M' <br />FL 1.10.1 FLOOR PLAN OPTIONS <br />FL 4.10 SECTIONS <br />FL5.10 ELEVATIONS M' <br />FL5.13.9 ROOFPLAN'M' 15 <br />FL6.10 UTILITY PLANS'M' <br />LOT 131 - PULSAR'B' 16. <br />FL 0.1,1 SLAB PLANS' <br />FL 1.2 FLOOR PLAN 13' <br />Ff. 1:2.1 FLOOR PLAN OPTIONS <br />F14.2 SECTIONS - <br />FL5.2 ELEVATIONS'B' <br />FL 5.13.1 ROOF PLAN'B' <br />FL 6.2 UTILITY PLANS'B' <br />LOT 132 - PULSAR 'N' 17. <br />FL 0.1.10 SLAB PLAN N' <br />FL 1.11 FLOOR PLAN IN'18. <br />FL 1-11.1 FLOOR PLAN OPTIONS <br />FL4.11 SECTIONS <br />FL 5.11 ELEVATIONS N' <br />FL 5.13.10 ROOF PLAN'" <br />FL 6.11 UTILITY PLANS'N <br />19. <br />7-PLEX BUILDING - A <br />A 0.1 SLAB PERIMETER PLAN 7-PLEX <br />AO 1.1 <br />0.1.1 SLAB PERIMETER PLAN 7-PLEX <br />A 1'1 FIRST FLOOR PLAN 7-PLEX <br />A 1.1.1 FIRST FLOOR PLAN 7-PLEX 20. <br />A 2.1 SECOND FLOOR PLAN 7-PLEX <br />A 2.1.1 SECOND FLOOR PLAN 7-PLEX 21 <br />A5.1 ELEVATIONS 7-PLEX <br />A 5.1.1 ELEVATIONS 7-PLEX <br />A 5.1.2 ELEVATIONS 7-PLEX <br />A 5.13 ELEVATIONS 7-PLEX <br />A 5.1.4 ELEVATIONS 7-PLEX <br />A 5.1.5 ROOF PLAN 7-PLEX <br />A 5.1.6 ROOF PLAN 7-PLEX <br />DETAIL SHEETS <br />D-1 DETAILS <br />0-2 DETAILS <br />03 DETAILS <br />D-4 DETAILS <br />D-5 DETAILS <br />GENERAL NOTES: <br />CONTRACTORS SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT SITE BEFORE CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE BUILDER FOR <br />JUSTIFICATION AND/OR CORRECTION BEFORE CONTINUING WITH WORK. CONTRACTORS SHALL ASSUME RESPONSIBILITY FOR ERRORS THAT ARE NOT REPORTED TO <br />THE BUILDER. <br />ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES, REGULATIONS, AND FHA/VA MPS. <br />ALL DIMENSIONS SHOULD BE READ OR CALCULATED AND NEVER SCALED. <br />ALL FOOTINGS TO BE BELOW FROST LINE (SEE LOCAL CODE) AND MUST REST ON UNDISTURBED SOIL CAPABLE OF HANDLING THE BUILDING LOAD. CONSULT LOCAL <br />ENGINEER FOR PROPER FOOTING AND REINFORCING SIZES. <br />CONTRACTOR SHALL INSURE COMPATIBILITY OF THE BUILDING WITH ALL SITE REQUIREMENTS. <br />IF BACKFILL EXCEEDS 4' AGAINST ANY FOUNDATION WALL, REINFORCE AS PER CODE. <br />ALL WOOD, CONCRETE, AND STEEL STRUCTURAL MEMBERS SHALL BE OF A GOOD GRADE AND QUALITY AND MEET ALL NATIONAL, STATE, AND LOCAL BUILDING CODES <br />WHERE APPLICABLE. <br />ALL FOUNDATION AND STRUCTURAL MEMBERS SHOULD BE VERIFIED AND STAMPED BY AN ENGINEER IN THE STATE WHERE CONSTRUCTION IS OCCURRING DUE TO A <br />WIDE VARIANCE IN LOCAL CODES, SOIL BEARING CONDITIONS, FROST LINE DEPTH, GEOLOGICAL AND WEATHER CONDITIONS, ETC. <br />THE CONTRACTOR IS RESPONSIBLE FOR ADJUSTING AND VERIFYING ALL STRUCTURAL DETAILS AND CONDITIONS TO MEET ALL LOCAL CODES TO INSURE A QUALITY <br />AND SAFE STRUCTURE. <br />EXTERIOR FINISHES: INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C.R. -7TH EDITION (2020) RESIDENTIAL AND <br />STM C 1063. ALL LATH AND RESISTANT MATERIAL, EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 1 1/2 INCH 11 GAUGE NAILS HAVING A 7/16 INCH <br />HEAD, OR 7/8 INCH LONG 16 GAUGE STAPLES SPACED NO MORE THAN 6 INCHES, OR AS OTHERWISE APPROVED. THICKNESS OF TEXTURED FINISH OVER FRAME <br />APPLICATION TO FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL AND ASTM C 926. WEEP SCREEDS SHALL BE A MINIMUM OF NO. 26 GALVANIZED SHEET <br />GAUGE CORROSION -RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED WITH A MINIMUM VERTICAL FLANGE F -1 INCHES HALL BE PROVIDED <br />S S C U T CAL ATTACHMENT LA GE 0 3 /2 C S S <br />AT OR BELOW THE PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C 926. THE WEEP SCREED SHALL BE PLACED A MINIMUM OF 4 INCHES ABOVE <br />THE EARTH OR 2 INCHES ABOVE PAVED AREAS. THE WEATHER RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. STUCCO APPLICATION AND CURING PER <br />FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL OR IN ACCORDANCE WITH ASTM C 926. <br />CHAPTER AND SECTIONS REFER TO F.B.C.R. - 7TH EDITION NOTE: ANY DIMENSION AND/OR CALLOUTS WITHIN THIS SET OF DRAWINGS REFERENCING LUMBER <br />(2020). <br />SIZES OR WALL THICKNESS ARE TO BE CONSIDERED "NOMINAL DIMENSIONS". ALL DIMENSIONS ARE TO ROUGH FRAMING UNLESS OTHERWISE NOTED. <br />IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO ENSURE THAT ALL ELECTRICAL WORK IS IN FULL COMPLIANCE WITH N.F.P.A. 70, N.E.C. 2017, F.B.C.R. - <br />7TH EDITION (2020), AND ALL APPLICABLE LOCAL STANDARDS, CODES, AND ORDINANCES. <br />EGRESS: EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS TO EXTERIOR THROUGH A DOOR THE WINDOW <br />MUST HAVE A MAXIMUM CLEAR OPENING HEIGHT OF 44" ABOVE FINISH FLOOR LINE OF THAT PARTICULAR ROOM. <br />ASPHALT SHINGLES (IF APPLICABLE): <br />WIND RESISTANCE OF ASPHALT SHINGLES - ASPHALT SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION R905.2.6.1. <br />ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR GREATER FOR ROOF SLOPES FROM TWO <br />UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND LESS THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), TWO LAYERS OF UNDERLAYMENT COMPLYING <br />WITH ASTM D 226, TYPE I OR TYPE 11, ASTM D 486kfYPE 11 OR TYPE IV OR ASTM D 6757 IS REQUIRED IN ACCORDANCE WITH SECTION R905.11. FOR ROOF SLOPES <br />FROM FOUR UNITS VERTICAL IN 12 UNITS HORIZON i AL (4:12) AND GREATER, ONE LAYER OF UNDERLAYMENT COMPLYING WITH ASTM D 226, TYPE 11, ASTM D 4869, TYPE <br />IV OR ASTM D 6757 IS REQUIRED IN ACCORDANC ITH SECTION R905.11. <br />TERMITE TREATMENT WILL BE DONE USINGSENT CON TERMITE BAITING STATIONS AND AND SHALL BE IN ACCORDANCE WITH FBC(R), SECTION R318 AND ALL <br />RELATED SUB SECTIONS. <br />UTILITY EASEMENT: USE OF THE SUBDIVISION FO TILITIES, INCLUDING BUT NOT LIMITED TO UTILITY EASEMENTS AS SHOWN ON PLAT, SHALL BE IN ACCORDANCE <br />WITH THE APPLICABLE PROVISIONS OF THIS DECI ATION. THE DECLARANT AND ITS AFFILIATES AND ITS AND THEIR DESIGNEES SHALL HAVE A PERPETUAL <br />EASEMENT OVER, UPON AND UNDER THE LOTS (INOLUDING BUT NOT LIMITED TO THE UNITS) AND THE COMMON AREAS (EXCLUDING THE CONSERVATION AREAS) FOR <br />THE INSTALLATION, OPERATION AND MAINTENANCE OF UTILITY IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO ELECTRIC LINES, WATER AND SEWER PIPES, <br />TELEPHONE LINES, COMMUNITY AND / OR CABLE TELEVISION AND SECURITY AND OTHER COMMUNICATION LINES, EQUIPMENT AND MATERIALS AND OTHER SIMILAR <br />TELEVISION, RADIO AND SECURITY CABLES AND ALL FUTURE TECHNOLOGICAL ADVANCES NOT NOW KNOWN), FOR SERVICE TO THE LOTS AND OTHER PORTIONS <br />OF THE SUBDIVISION, PROVIDED THAT NO OWNER'S NORMAL RESIDENTIAL USE OF SUCH OWNER'S UNIT SHALL BE INTERFERED WITH IN ANY UNREASONABLE <br />MANNER. <br />EXTERIOR WALL ENVELOPE: BUILDER IS RESPONSIBLE FOR PROVIDING AND MEETING ALL REQUIREMENTS OF SECTION 107.2.4 OF THE F.B.C. BUILDING BY PROVIDING <br />ALL DETAILS LISTED UNDER THIS SECTION, INCLUDING BUT NOT LIMITED TO, THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ALL SUPPORTING <br />DOCUMENTATION TO ENSURE THE WEATHER RESISTANCE OF THE EXTERIOR WALL ENVELOPE IS MAINTAINED. <br />STUCCO CONTROL JOINTS TO BE INSTALLED PER ASTM C 1063-06 7.11.4.1 THRU 7.11.4.4 AT FRAMED WALLS TO DELINEATE AREAS NOT MORE THAN 144 S.F. AND <br />DELINEATE AREAS NOT MORE THAN 100 S.F. FOR HORIZONTAL APPLICATIONS. DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18 FT. IN EITHER DIRECTION <br />OR A LENGTH -TO -WIDTH RATIO OF 2 1/2 TO 1. A CONTROL JOINT SHALL BE INSTALLED WHERE CEILING FRAMING OR FURRING CHANGE DIRECTION, AND WHERE <br />EXPANSION JOINT OCCURS IN BASE EXTERIOR WALL. WALL OR PARTITION HEIGHT DOOR FRAMES SHALL BE CONSIDERED AS CONTROL JOINTS. <br />FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR <br />DIRECTIONS, AND AROUND ROOF OPENINGS. <br />APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY <br />OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SH ALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />FINISH. APPROVED CORROSION -RESISTANT FLASHING SHALL BE INSTALLED AT ALL REQUIRED LOCATIONS PER R703.8. <br />WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION <br />INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. <br />ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE GENERAL CONTRACTOR AS AN ATTACHMENT TO THIS PLAN SET AT <br />THE TIME OF APPLICATION FOR PERMIT. <br />MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, <br />OTHER APPLIANCES ANY OTHER PIPING OR DUCTS NOT CONNECTED T THE APPLIANCE BEING INSPECTED,ERVI ED REPAIRED R REPLACED. A LEVEL <br />,OR U S OSERVICED, O <br />WORKING SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES (762 MM) WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. <br />DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED A MIN. #26 <br />GAUGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. <br />FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3 INCHES (76 MM) ABOVE THE FINISHED GRADE AND SHALL ALSO <br />CONFORM TO THE MANUFACTURERS INSTALLATION INSTRUCTIONS. <br />AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDING <br />COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />APPLICABLE PROVISIONS OF SECTIONS M1411.3, <br />THIS PROJECT MUST COMPLY WITH: 2020 FLORIDA BUILDING CODE RESIDENTIAL - 7TH EDITION, FLORIDA FIRE <br />PREVENTION CODE 7TH EDITION (THIS INCLUDES THE FLORIDA SPECIFIC EDITION OF 2018 NFPA 1 UNIFORM FIRE CODE, <br />AND 2018 NFPA 101 LIFE SAFETY CODE). NFPA 10, 2018 EDITION, STANDARD FOR PORTABLE FIRE EXTINGUISHERS. NFPA <br />13D, 2016 EDITION, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS IN ONE- AND TWO-FAMILY DWELLINGS <br />AND MANUFACTURED HOMES. NFPA 70, 2017 EDITION, NATIONAL ELECTRICAL CODE. NFPA 72, 2016 EDITION, NATIONAL <br />FIRE ALARM AND SIGNALING CODE. NFPA 90A, 2018 EDITION, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING <br />AND VENTILATING SYSTEMS. 2020 FLORIDA BUILDING CODE ENERGY CONSERVATION, 7TH EDITION. 2020 FLORIDA <br />BUILDING CODE MECHANICAL, 7TH EDITION. 2020 FLORIDA BUIDLING CODE PLUMBING, 7TH EDITION, 2020 FLORIDA <br />BUILDING CODE FUEL GAS, 7TH EDITION. <br />O CUP N Y� RESIDENTIAL - R3 CONSTRUCTION TYPE: VB-PROTECTED, SPRINKLED <br />TYSON <br />7-PLEX A <br />LOTS 126-132 <br />PLAN 1386 PULSAR SF <br />TOTAL BUILDING SF <br />NAME <br />I AREA <br />NAME <br />I AREA <br />FIRST FLOOR <br />1588 SF <br />FIRST FLOOR <br />14858 SF <br />SECOND FLOOR <br />1798 SF <br />SECOND FLOOR <br />16525 SF <br />HEATED 1386 SF <br />HEATED 11383SF <br />GARAGE <br />226 SF <br />GARAGE <br />1771 SF <br />PORCH <br />32 SF <br />PORCH <br />249 SF <br />PATIO 1 COV. PORCH <br />80 SF <br />PATIO / COV. PORCH <br />1640 SF <br />UNHEATED 338 SF <br />JUNHEATED 2660 SF <br />ALL WORK SHALL COMPLY WITH F <br />CODES FLORIDA BUILDING CODE, <br />NATIONAL ELECTRIC CODE, <br />AND THE CITY OF ZEPHYRHILLS <br />ORDINANCES <br />nJ <br />i, <br />z <br />CM <br />W <br />ISSUE DATE: <br />06.01.2023 FOR <br />REVIEW <br />REVISIONS: <br />Th s drawin s ar e e e e th <br />9 <br />property of Starlight <br />Homes and are not to be <br />utilized for construction, or <br />copied in part or in whole <br />without permission from <br />the builder. @c 2023 <br />Starlight Homes <br />I LAST REVISION I <br />SHEET NO: <br />T-1 <br />i� <br />