My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Daerr Ridge St
Zephyrhills
>
Building Department
>
Building Plans
>
Daerr Ridge St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:37:26 PM
Creation date
2/19/2025 7:54:13 AM
Metadata
Fields
Template:
Building Plans
Location
Daerr Ridge St
Contractor
Starlight Homes
Description
Tyson 7 Plex
Building Plans - Permit #
6495
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C3 <br />J <br />O <br />LOT 126 <br />Q <br />ISSUE DATE: <br />06.01.2023 FOR <br />REVIEW <br />4.1 <br />2" Hr REVISIONS: <br />nG <br />RAKE <br />I AREA 1 ( <br />I <br />i These drawings are the <br />I i property of Starlight <br />y N1 I Homes and are not to be <br />( A i utilized for construction, or <br />copied in part or in whale <br />I without permission from <br />the builder. © 2023 <br />I Starlight Homes <br />I I LAST REVISION <br />t._... ..._.r l .:RIDGE <br />E <br />I i I �Ae �� •t° / • <br />f ...... ... LL <br />a R • C� <br />ROOF VENT CALC. ELEV. 'O' <br />Name Afea 11300 RATIO AT HIGH & LOW 1/150 RATIO AT HIGH & LOW �j , <br />AREA i 846 SF 202.96 in= 405.92 in= � . i .�� R <br />I 11 At�t! 1 <br />I I (n p <br />I LOMANCC D, INSTALL PER I <br />LOCATION <br />EBUILDE tanCNS, I Z <br />- I LOCATXN4 fl BUILDER I Q <br />O <br />Q <br />LL <br />6 <br />1 <br />�F <br />_.. ......_ ...............y_._ _ ......_.--'--' 10'3' 9'-11' Is1 W <br />PROOF PLAN 'O' a' <br />1/4' . 1'-0" AT 22"X34" LAYOUT IV - 1'-0" AT 11' X 1 T LAYOUT <br />SHEET NO: <br />FL 5.13.11 <br />1/150 RATIO: <br />1/300 RATIO: <br />GENERAL CONTRACTOR SHALL VERIFY THE <br />AS AN ALTERNATE TO THE 1/150 RATIO LISTED, THE NET <br />NET FREE VENTILATION OF THE VENT <br />FREE CROSS -VENTILATION AREA MAY BE REDUCED TO 1/300 <br />PRODUCT SELECTED BY OWNER. VERIFY WITH <br />WHENA VAPOR BARRIERSHAVINGATRANSMISSION RATE <br />MANUFACTURER OF HIGH AND LOW VENTS TO <br />NOT EXCEEDING 1-PERM INSTALLED ON THE WARM4N• <br />BE USED FOR MINIMUM CALCULATED VENTS <br />WINTER SIDE OF THE CEILING. <br />REQUIRED. THE REQUIRED VENTILATION SHALL <br />8E MAINTAINED. PROVIDE INSULATION STOP <br />GENERAL CONTRACTOR SHALL VERIFY THE NET FREE <br />SUCH THAT INSULATION DOES NOT OBSTRUCT <br />VENTILATION OF THE VENT PRODUCT SELECTED BY <br />FREE AIR MOVEMENT AS REQUIRED BY THE <br />OWNER. VERIFY WITH MANUFACTURER � HIGH AND LOW <br />BUILDING OFFICIAL. <br />VENTS TO BE USED FOR MINIMUM CALCULATED VENTS <br />REQUIRED. THE REQUIRED VENTILATION SHALL BE <br />ALL OVERLAP FRAMED ROOF AREAS SHALL <br />MAINTAINED. PROVIDE INSULATION STOP SUCH THAT <br />HAVE OPENINGS BETWEEN THE ADJACENT <br />INSULATION DOES NOT OBSTRUCT FREE AIR MOVEMENT AS <br />ATTICS IN THE ROOF SHEATHING (AS ALLOWED <br />REQUIRED BY THE BUILDING OFFICIAL. <br />BY THE STRUCTURAL ENGINEER) TO ALLOW <br />PASSAGE AND ATTIC VENTILATION BETWEEN <br />ALL OVERLAP FOAMED ROOF AREAS SHALL HAVE OPENINGS <br />THE TWO OR ISOLATED ATTIC SPACES SHALL <br />BETWEEN THE ADJACENT ATTICS IN THE ROOF SHEATHING <br />BE VENTED INDEPENDENTLY TO MEET 2020 <br />(AS ALLOWED BY THE STRUCTURAL ENGINEER) TO ALLOW <br />FLORIDA BUILDING CODE. <br />PASSAGE AND ATTIC VENTILATON BETWEEN THE TWO OR <br />ISOLATED ATTIC SPACES SHALL BE VENTED <br />PER DEVELOPER AT ALL CANTILEVERED <br />INDEPENDENTLY TO MEET 2020 FLORIDA BUILDING CODE. <br />FLOORS, CANTILEVERED DECORATIVE <br />PROJECTIONS, AND ANY DOUBLE FRAMING <br />PER DEVELOPER, AT ALL CANTILEVERED FLOORS, <br />PROJECTIONS THAT ARE SEPARATED FROM <br />CANTILEVERED DECORATIVE PROJECTIONS, AND ANY <br />THE VENTING CALCULATIONS SHOWN ABOVE. <br />DOUBLE FRAMING PROJECTIONS THAT ARE SEPARATED <br />PROVIDE A CONTINUOUS 2" CORROSION <br />FROM THE VENTING CALCULATIONS SHOWN ABOVE, <br />RESISTANT SOFFIT VENT AT UNDERSIDE OF <br />PROVIDE A CONTINUOUS 2" CORROSION RESISTANT SOFFIT <br />FRAMED ELEMENT. <br />VENT AT UNDERSIDE OF FRAMED ELEMENT. <br />NOTES: <br />e ALL ROOF DRAINAGE SHALL BE PIPED TO 0 TRUSS MANUFACTURER SHALL SUBMIT STRUCTURAL CALCS <br />STREET OR APPROVED DRAINAGE AND STOP DRAWING TO THE BUILDERS GENERAL <br />FACILITY. CONTRACTOR AND BUILDING DEPARTMENT FOR REVIEW <br />� DASHED LINES INDICATE WALL BELOW. PRIOR TO FABRICATIONS. <br />0 LOCATE GUTTER AND DOWNSPOUTS PER 0 ALL PLUMBING VENTS SHALL BE COMBINED INTO A MINIMUM <br />BUILDER. AMOUNT OF ROOF PENETRATIONS. ALL ROOF PENETRATIONS <br />0 PITCHED ROOFS AS NOTED. SHALL OCCUR TO THE REAR OF THE MAW RIDGE. <br />
The URL can be used to link to this page
Your browser does not support the video tag.