My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Elby Ln
Zephyrhills
>
Building Department
>
Building Plans
>
Elby Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:44:47 PM
Creation date
2/19/2025 7:55:12 AM
Metadata
Fields
Template:
Building Plans
Location
Elby Ln
Contractor
Starlight Homes
Description
Tyson 7 Plex
Building Plans - Permit #
6502-6506
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
x <br />C� <br />* N <br />J � <br />Q <br />Q <br />o <br />F-. <br />o <br />ISSUE DATE: <br />LOT 271 PAT-1- NP/GFl. <br />A!C COND. o <br />Alc <br />_ <br />He i <br />WP/GFI '.( <br />_ •._� a -- <br />05.25.2022 FOR <br />REVIEW <br />REVISIONS: <br />WI - '- <br />gg <br />E \ � <br />FAMILY RM 6 <br />1,0 <br />B E i) <br />.*TV I <br />'j <br />Q- - ANAS <br />@ <br />d <br />p= <br />,,GG,, / • REQUIRED PER <br />0,-'C A STATE AND <br />•/ - LOCAL BUILDING lens <br />_ -'' ' CODE <br />i <br />F,f <br />These drawings are the <br />property of Starlight <br />Homes and are not to be <br />v <br />j <br />DISHWASHER <br />DISPOSAL KIf1}'a �; <br />\ <br />utilized for construction, or <br />copied in part or in whole <br />w <br />without permission from <br />+ <br />the builder. @ 2022 <br />a= <br />a <br />6F1 _ _ 7( <br />VP � <br />E € <br />+ HVAC <br />MICROWAVE <br />GFI - €' <br />SERVICE ®{, <br />PANEL ' o s <br />Starlight Homes <br />g <br />LAST REVISION <br />STANDARD ELECTRICAL BOX HEIGHTS <br />CF"i •s' ) + '.i <br />1{` <br />trl s + €TOLIGHT/ <br />SWITCH <br />LESS j B QW i <br />i72-0' -LLU' REC.IFREQ/ "„ © SWITCHTO ! <br />( ABOVE <br />F \ WATER HEATER -' 'O SERVICE PANEL <br />@@ `� I- - SIZE AND LOCATION <br />m� <br />LAST SAVED BY: <br />S ; <br />€ <br />�y ;-y% 1 = / PERBUILDERS <br />c <br />ZIGHTIN <br />K: <br />SPECIFICATIONS <br />AND LOCAL CODES 7 <br />ELECTRIC METER <br />`_ <br />SION <br />TELEVISION <br />KEYLESS <br />(� <br />B 3:, <br />N SERVICE 80% <br />Js t (J� <br />BED 2 <br />/GFI DOOR <br />OPENER <br />3P NGHVANRY T ° 8/SE C.BBiET '+ <br />CARNET <br />i <br />�71W-P]/GFI' <br />I <br />CM <br />`•�/ <br />In <br />3 s <br />5 <br />- -----------4HB - <br />C <br />a <br />SWITCH AND RECEPTACLE BOXES SWITCH AND RECEPTACLE BOXES <br />NOTE: EXTERIOR W-P.OUTLET REWIRED NEAR AIG CONDENSER (NOT SHOWN) <br />ti <br />OVER BATH CABINETS OVER KITCHEN CABINETS <br />SECOND FLOOR PLAN 1OL-0" <br />FIRST FLOOR PLAN 1O1 <br />2 <br />1'AT ;;X.- LAYOUT = V-0' AT 11' X 17' LAYOUT <br />1 <br />114". V 0' AT 22"%34' LAYOUT =1'-0" AT 11" X 1 T LAYOUT <br />NOTES: <br />LEGEND: <br />- PROVIDE GROUNDING ELECTRICAL ROD PER LOCH. CODES. <br />- PROVIDE AND INSTALL ARC FAULT CIRCUIT-INTERRUPTERS(AFCp AS REWIRED BY NATIONAL ELECTRICAL <br />CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. <br />D+rtE —T <br />{�'"'"'°° WEATHERPROOF OR DIwIEzounET <br />tB clw.Es <br />�zz+O NOUNIE(1 Bf,ANDESCFNi <br />Lzurt wxruAE PusHBunaN svmcN <br />(FnovQE ADEOLMIE suPPORn <br />G cEzva FAN <br />• ALL EXHAUST FANS SHALL HAVE SACKDRAFT DAMPERS. <br />a ffl DROUNDiAULT cll€culr-mTEflwm€En <br />h ea ++sv 9401� °ETEcreN <br />WALLYOLNTED NCANOES(.FNT CT HMDNANED AND MiEP, <br />- FAWUGHTS IN WET/DAMP LOCATIONS SHALL BE LABLED 'SU ITABLE FOR WET OR DAMP LOCATIONS.* <br />DUPIE%OUTIET <br />r`' f Lzarr FDcrulet coNNEcrED xv BATTERr <br />BACKUP <br />LqM CWRN NlCANDESCENT <br />FAIND FANFIXTURE <br />- ELECTRICAL SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE <br />IP HUF.swrtcHEDDuttEz ouTler <br />y AMSSE°wcANDEscENruprt FumwE oDp pETECTOR <br />{} oR CEBAVO NODN1eDIED FucruRE eWRDwMEDAND erER. <br />/ \ (PROVIDE ADE° Ws n" <br />V V <br />CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND PLACEMENT. <br />' za�va.TamET <br />(vw.v.Fofl PRooF ® eAOa w EO W BATtERY <br />- PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AND CO2 DETECTORS AS REWIRED BY <br />NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. <br />- PROVIDE AND INSTALL GROUND FAULT GRCUIT-INTERRUPTERS (GFII AS REQUIRED BY NATIONAL ELECTRICAL <br />'� I�zsoRCE°.zlNCTzm Box <br />0 Ex WTF.n M—oEZTEPoOR) 1HEPo.OSfAt <br />I-$ Lus suPPLv wrm vuvE <br />CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. <br /># W.usWrw <br />ds EIOW�Si FNIhWHT GOM&NAl%MI ® WLEPONE <br />T� NosEe66 <br />- ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS/CUTOFFS. <br />l� (AENr TO ExIERIOR€ tE gpry <br />- HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. <br />- ALL ELECTRICAL <br />#a THREEW'AYSWRCH <br />8 <br />v +H• WATER stusouT <br />SHEETNO: <br />AND MECHANICAL EQUIPMENT (FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, ++ FWORESCENi LMd(T F1%NflE ELECTRIC I.ETER <br />DRAINTILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. f A FODR-WAY swrtcN <br />0 ELECTflN: PANEL <br />- PROVIDE POWER. LIGHT AND SWITCH AS REQUIRED FOR ATTIC FURNACE PER CODE AND MANUFACTURER'S , tow VOLrADE ouTLEr li DlscoNNECTsw+rcH -il wut scoNCE <br />WPo NINSTRUCTIONS. TECH HUB SYSTEM <br />- PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AND CO2 DETECTORS. UNITS MST BE <br />F L 6.12 <br />HARDWIRED, INTERCONNECTED AND PROVIDE BATTERY BACKUP. <br />
The URL can be used to link to this page
Your browser does not support the video tag.