My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3621 Copeland Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3621 Copeland Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:00:40 AM
Creation date
2/19/2025 8:13:57 AM
Metadata
Fields
Template:
Building Plans
Street #
3621
Location
Copeland Dr
Contractor
Stine Construction
Building Plans - Permit #
16516
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I _ I II 1! I' I' 111 I!1 <br />MOJEGT DATA: <br />OWNER: MORROA STEEL, ING. <br />CONTACT: BILL MORROW <br />OWNER PHONE: 513-115-0404 <br />ADDRE55: 3620 COPELAND DRIVE, ZEPHYRHILL5, FL 55542 <br />BUILDING DATA: <br />SEE SHEET AO.4 FOR CODE DATA <br />FBG OGGUPANGY CLASSIFICATION: BUSINESS <br />NFPA OCCUPANCY GLA551FIGATION: BUSINESS <br />BUILDING TYPE - TYPE VB, NOT SPRINKLED <br />APPLICABLE 6005: <br />FLORIDA BUILDING CODE, 2010 EDITION (FBG). <br />FLORIDA FIRE PREVENTION CODE, 2010 EDITION (FFPC)/ <br />NFPA 101, LIFE SAFETY CODE, 200cl EDITION (NFPA). <br />FLORIDA BUILDING CODE, AGGE55151LTY, 2010 EDITION, <br />FLORIDA BUILDING CODE, EXI57IN5 BUILDING, 2010 EDITION. <br />(LEVEL 1 8 2 ALTERATIONS AND ADDITION). <br />GENERAL NOTES <br />I. A GENERAL CONTRACTOR (G.G.) OR CONSTRUCTION MANAGER (G.M.) SHALL NOTE THAT THE <br />ARCHITECTURAL DRAWING5 ARE ESTABLISHING A MINIMUM MATERIAL OR GON5TRUGTION METHOD <br />STANDARD. THE G.G.IG.M. SHALL PROVIDE A 'BID' PRICE BASED ON THE SPECIFIC MATERIALS <br />5HOWN AND NOTED. <br />2. THERE SHALL BE NO DEVIATION BY THE G.G. /G.M. FROM THE CONSTRUCTION <br />DOCUMENTS UNLESS APPROVED IN WRITING BY THE ARGHITECT. <br />3. PLAN DIMENSIONS ARE GIVEN TO FACE OF STUDS OR BLOCK WALL5 WHEN NOT <br />DIMENSIONED TO THE CENTERLINE OF STUDS. "CLEAR" <br />DIMENSIONS ARE GIVEN TO THE FACE OF FINISHED MATERIALS. <br />4. LARGER DE7AIL5 TAKE PRECEDENCE OVER SMALLER DETAILS. <br />5. HARD COPY PAPER DRAWING5 TAKE PRECEDENCE OVER ALL ELECTRONIC FILES. <br />6. N.I.G. MEANS THAT IT WILL BE PURCHASED AND INSTALLED BY OWNER. <br />P.B.O. MEANS THAT IT WILL BE PURCHASED AND BROUGHT TO THE SITE BY OWNER <br />AND INSTALLED BY G.G. <br />1. "SIMILAR" MEANS COMPARABLE TO ANOTHER DETAIL WITH MINOR DEVIATION. <br />5. THE OWNER WILL A55UME ALL LIA51LITY AND SHALL TAKE PER50NAL <br />RESPONSIBILITY FOR ANY DECISIONS THAT THEY MAKE TO GHANGE OR <br />ALTER THE CONSTRUCTION DOCUMENTS WITHOUT THE ARCHITECT'S <br />WRITTEN APPROVAL. <br />q. G.G.IG.M. SHALL FURNISH TO THE J05517E FOR THE INSPECTOR, COPIES OF THE <br />PRODUCT 7E5TIN6 AND EVALUATION REPORTS (INCLUDING PRODUCT INSTALLATION <br />REQUIREMENT5 THAT MEET OR EXCEED THE GODE REQUIRED WIND RESISTANCE <br />PERFORMANCE CRITERIA) FOR EACH MATERIAL USED IN THE PRODUCT APPROVAL <br />CHART TO RIGHT. <br />10. TERMITE TREATMENT: (IF REQUIRED) <br />A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED <br />FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE <br />516N SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL. FBG 105.11 <br />A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY A <br />LICENSED PE5T CONTROL COMPANY BEFORE A CERTIFICATE OF OGGUPANGY WILL BE <br />ISSUED. <br />11. NO INTERIOR 516NA6E PROVISIONS ARE INCLUDED IN THESE DOCUMENTS (SIGNAGE BY OWNER <br />4 ARGHITECTURAL FIRM). G.G. TO PROVIDE AN ALLOAANGE <br />12. FLOOR FIN15H MATERIALS TO BE GLA55 I OR II IN AGGORDANGE W/ FBG 504 AND NFPA 253. <br />INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED IN ACCORDANCE A/ <br />ASTM E 54 PER F.B.G. 505 AND MEET THE REQUIREMENT5 PER OCCUPANCY OF FBG TABLE 503.5. <br />ALL OTHER FINISH MATERIALS TO BE CLASS "A". <br />15. DE516N INTENT 15 TO HAVE 3 1/2" MIN. R-11 SOUND BATT. INSULATION IN ALL INTERIOR WALLS. <br />14. FINISH MATERIAL5/GOLOR5: ANY MATERIAL WITH A FF, 5F, GF, AND P KEYNOTE NUMBER CAN <br />BE FOUND IN A SEPERATE 5-1/2X11 MATERIALS MANUAL <br />15. SHOP DRAWIN65 (5 COPIES MAX.) TO BE PROVIDED TO ARCHITECT FOR REVIEW AFTER THEY HAVE BEEN <br />REVIEWED AND 516NED/1")ATED BY THE G.G./G.M,, AND SHALL INCLUDE BUT NOT BE LIMITED TO THE <br />FOLLOWING ITEMS: (ELECTRONIG FILES AT THE DI5CRE5510N OF THE ARCHITECT WILL BE PROVIDED <br />THRU THE G.G./ G.M. TO THE SUB-GONTRAGTOR FOR USE IN DRAWING ANY SHOP DAG5). <br />- M15O. ALUMINUM - ALUMINUM STOREFRONT AND <br />CURTAIN WAL <br />- MISG. STEEL L SYSTEM <br />- STRUCTURAL 57EEL, BEAMS, - ACOUSTICAL GLG. t GRID <br />COLUMNS s JOISTS. - EXTERIOR PAINT <br />- CABINETRY MILLWORK - HVAG EQUIP. <br />- EXTERIOR GLADDING - KITCHEN EQUIPMENT <br />- EXTERIOR WATERPROOFING - PLUMBING FIXTURES <br />- MEMBRANE ROOFING 8 INSULATION - ELEGTRIGAL EQUIP. 4 FIXTURES <br />- METAL WALL PANELS - 5EGURI7Y/GOMMUNICATION5 <br />- ALL DOOR5, FRAMES @ HARDWARE <br />- ALL WINDOWS, FRAMES $ HARDWARE <br />NO CONSTRUCTION SHALL OCCUR ON ANY OF THE ABV. WITHOUT SHOP DRAWING APPROVAL. <br />NORTH ARROW <br />DETAIL <br />ELEVATION TARGET <br />REVISION <br />DOOR / KEYNOTE <br />WINDOW <br />WALL TYPE <br />FLR./ GLG. FINISHES <br />FOUNDATION TYPE <br />ROOM NUMBER <br />, , LOCATION <br />`r ELEVATION <br />AU <br />NUM <br />F-NU F-NU <br />X <br />EARTH, FILL <br />CONCRETE <br />5TEEL <br />GONGRETE COLUMN <br />8" GMU. WALL -GROUT <br />ALL CELLS SOLID <br />DENOTES FILLED CELL <br />A/ 1-#5 VERT. BAR <br />NON -LOAD BEARING 3 5/5" 25 GA. <br />MTL. STUD WALL ® 24" O.G. (U.N.O.) <br />GORE -FILL INSULATION <br />WOOD SHIM <br />DECORATIVE TRIM <br />% % <br />(NON-5TRUGTURAL) <br />I <br />PLYWOOD <br />DENS-6LA5 GOLD <br />0 <br />GYPSUM <br />STUCCO <br />FRO 03 R__ <br />MATERIAL/WALL LEGEND <br />SECTION 1 1/2" RIGID INSULATION ® 5EG7ION <br />SECTION, PLAN 3" (RII) SOUND BATT. IN5UL. SECTION, PLAN <br />SECTION HVAG SUPPLY HVAG RETURN <br />METALAIR MODEL #5500-6 z z <br />PLAN <br />PLAN <br />SECTION, PLAN <br />SECTION <br />SECTION <br />SECTION <br />SECTION <br />SECTION <br />5EGTION, PLAN <br />SECTION, PLAN <br />EXI75 SEE ELEG. DRA65. FOR ACTUAL <br />EXIT 51GN5 <br />EXHAUST FAN O <br />EXIT 516N <br />SUSPENDED LIGHT <br />WALL MTV. LIGHT FIXTURE/5GONCE <br />FLUORESCENT STYLE LIGHTING <br />2X2 2X4 <br />JUNCTION BOX <br />5TATE OF: FLORIDA <br />APPROVAL NUMBER <br />I I I - <br />• Ir <br />• I . - <br />• 11 - 11 <br />• <br />I I •I- I <br />- I I I <br />�e5TOREFRONT <br />5"r5TEM• <br />s <br />I I <br />I I I <br />:• <br />:I I <br />I I <br />• : <br />11 - <br />• <br />• I I <br />�- <br />'•• <br />•- <br />•III <br />/ <br />/ <br />I • I <br />- <br />GI <br />_ <br />I -I I I <br />• <br />I I I <br />• <br />I I <br />r <br />e. - <br />_ <br />I I - <br />I I <br />-r <br />- -I I <br />-.I r1 <br />♦ �.� ♦ � <br />�' I <br />-I <br />-I I •I- I <br />11 11 <br />I I <br />- i <br />- 11- 11 • <br />.I I <br />/ <br />I I I <br />1100111 <br />Nal <br />• <br />� <br />;' \ \ \ \ ' \\ \ <br />\ sue\ <br />. \ <br />.. ...,. \ <br />\ <br />' <br />_ <br />\ <br />:< . <br />\ :: \\ ... \: <br />.�... <br />\\ \\\ \ . <br />\� \ \\ <br />_ <br />........\ >a��\ \\\ <br />\\ <br />'\NN- <br />\ <br />.. \ \\\ \\\\ <br />\\\\,,\ <br />RON\\\._ <br />ROOM NAME <br />SCHEDULE <br />ROOM <br />NO. <br />ROOM NAME <br />101 <br />ENTRY/RECEPTION <br />102 <br />HALLWAY <br />102A <br />WEST HALLWAY <br />1025 <br />EAST HALLWAY <br />105 <br />PURCHASING OFFICE <br />104 <br />PURCHASING ASSISTANCE OFFICE <br />105 <br />PLOT ROOM <br />106 <br />PROJECT MANAGEMENT OFFICE <br />101 <br />ERIC'S OFFICE <br />105 <br />GHAD'S OFFICE <br />IOq <br />SALES $ ESTIMATING OFFICE <br />110 <br />FILE STORAGE <br />III <br />WOMEN'S RE5TROOM <br />112 <br />YENS RE5TROOM <br />115 <br />BREAK ROOM <br />1 A <br />SERVER CLOSET <br />115 <br />CONTROLLER'S OFFICE <br />116 <br />BILLS OFFICE <br />Ill <br />PRIVATE RE5TROOM <br />115 <br />CLOSET <br />IIq <br />PAYROLL/HR OFFICE <br />120 <br />FILE 5TORA6E <br />121 <br />AGGOUNTING OFFICE <br />122 <br />CONFERENCE ROOM <br />0 revision by <br />0 <br />0 <br />klar and klar <br />architects inc. <br />28473 u.s. 19 n. <br />clearwater, fl 33761 <br />JU <br />kj <br />® <br />SIC <br />LU <br />American Institute of Architects <br />member firm <br />❑ Roberta S. Klar <br />® Steven L. Klar <br />U0000- <br />AA 0002321 <br />❑ Preliminary <br />® Permitting Set <br />[$I Construction Set <br />Date: <br />OE.06.15 <br />Drawn: <br />5K/HE/KN <br />Sheet: <br />Of: <br />
The URL can be used to link to this page
Your browser does not support the video tag.