OWNER'S BATHROOM <br />SCALE: 3/8" =1'-0" <br />BATHROOM 2 <br />SCALE: 3/8" = V-0" <br />STAIR DATA: <br />18 RISERS @ 7.153" <br />17 TREADS @ 10" <br />TOTAL RISE = 10'-8 3/4" <br />TOTAL RUN = 14'-2" <br />42" KNEE WALL <br />\\ <br />WITH 1x8 CAP & <br />3/4" PLYWOOD <br />CASING (AT2nd <br />DECKING \\ <br />FLOOR ONLY) <br />\ <br />\ <br />C0 <br />\ <br />\ <br />F. FL. <br />_ ----- <br />\ <br />--------a-- -. <br />18 <br />\ <br />;- <br />17 <br />\ \ <br />16 <br />\� <br />15 <br />\ <br />14 <br />\\ <br />13 <br />\\ <br />12 <br />11 <br />CONT. <br />10 <br />HAND RAIL <br />2x STRINGERS <br />4 <br />F. FL. JU � I J - � LJ -21 <br />TYP. STAIR SECTION. <br />HEADER SCHEDULE <br />MARK HEADER SIZE REMARKS <br />H1 (2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 (2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 (2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 (2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 (2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 (2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 (2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 (2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />RAG FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />R.O. CMU R.O. FRAME <br />SIZE (Flange) (Fin) TYPE <br />12 20 X 26 18 J X 25 i S.H. <br />13 20 X 381 18 J X 3711 S.H. <br />14 20X501 182'X50 S.H. <br />15 20X63 18JX62i S.H. <br />16 20X72 1817X71 S.H. <br />1 H2 27 1/4 X 26 26 X 25 S.H. <br />1H3 271/4X381 26x37�q S.H. <br />1 H4 27 a X 50 1 26 x 50 S.H. <br />1H5 27JX63 26X621/2 S.H. <br />1H6 27,X72 26X711/2 S.H. <br />22 37JX26 36JX251/2 S.H. <br />23 37 J X 38 i 36 J X 37 3/4 S.H. <br />24 37 J X 501 36 71 X 50 S.H. <br />25 37 J X 63 36 J X 62 1/2 S.H. <br />26 37 J X 72 36 4 X 71 1/2 S.H. <br />DOUBLE 2 WIDE 75" TALL 73 J WIDE S.H. <br />32 54 X 26 52 J X 25 i S.H. <br />33 54 X 38 J 52 J X 37 i S.H. <br />34 54 X 50 J 52 4 X 50 S.H. <br />35 54 X 63 52 J X 62 J S.H. <br />36 54 X 72 52 J X 714 S.H. <br />39X59 40 X 59 N/A S.H. <br />DOUBLE 39X59 79 X 59 N/A S.H. <br />(2) 2X8 w/ 1/2" <br />FLITCH HEADER <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL. _ <br />DRYWALL <br />1 1/2" MIN. CLEARANCE <br />1 1/4" TO 2" DIA <br />HANDRAIL NO <br />LESS THAN 34 <br />NOR MORE <br />THAN 38" ABV. <br />TREAD NOSING <br />METAL <br />HANDRAIL <br />BRACKET <br />BLOCKING AS <br />REQUIRED <br />Q <br />U Q <br />:- <br />w U <br />Z <br />W <br />J <br />0 <br />� <br />w <br />x <br />z <br />F. FL. HANDRAIL DETAIL <br />2x4 #2 SYP. P.T. THRUST SCALE: 3" =1'-0" <br />BLOCK W/(2)-14x 31/2" <br />TAPCONS @ 16"o.c. AND <br />3" FROM EA. END. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the waikline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '/2 inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 318 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />13'-4" 3'-8" <br />10 <br />VERIFY <br />[ACC PAD LOCATION OF <br />A/C PAD <br />HB <br />A OUTDOOR LIVING <br />S3 9'-4" CLG. A.F.F. <br />CONCRETE <br />6068 SGD <br />7'-11" <br />M © � <br />M <br />DINING <br />9'4' FLAT CLG. <br />® TILE <br />00 <br />o - <br />Y <br />i0 <br />LO <br />FLRG. LINE <br />8,-0„ <br />® czn <br />10 N <br />C9 <br />a; - ED1 <br />0 M <br />. TYP. U. <br />_. O <br />co <br />(V <br />in <br />STONE <br />VENEER <br />d 16" SQUARE- <br />CMU COLUMN <br />I <br />3068 <br />5-SH NJ <br />2468 REF <br />I <br />6'-7" ' <br />o I <br />O <br />O <br />I <br />cw7 110 <br />KITCHEN Q ' <br />9'-4" FLAT CLG, m I <br />TILE <br />t <br />SINK w/ <br />D/W DISPOSAL <br />1 I oo r._ J <br />T) 16" CNTR. AT 42" <br />A.F.F. <br />3'-8" <br />0 <br />10 <br />1/2 WALL <br />CAPPED <br />f <br />II UP <br /><V <br />GREAT ROOM <br />9'-4" FLAT CLG. <br />CARPET <br />2'-4" 4'-8" <br />-. <br />EN Y <br />9'-4" FLG. A.F.F. <br />CONCRETE <br />co O <br />f � <br />o - <br />in <br />00 <br />f <br />00 <br />HB <br />00 0 <br />EO <br />ir) <br />0 <br />CV <br />V-4" 5'-8" 111-81, <br />GG <br />S3 <br />4'-4" <br />' • T <br />1 <br />!r �® 1 <br />i G <br />® Y <br />Cp, <br />`~I W.H <br />BUILDER TO <br />PROVIDE <br />APPLIANCE <br />PROTECTION <br />WHEN <br />REQUIRED PER <br />FBC <br />1-CAR ARAGE <br />9'4" FLAT CLG. <br />r- - - - - - - - - - ------i <br />I I <br />I I <br />I I <br />LINE OF 2nd STRY. ABV. <br />-*NOTE` I <br />BLK. WALLS ARE 8'-8" <br />TALL FOR "A" NIT 5-8" <br />FROM FRO14T OF <br />GARA E <br />K TYP. @ I <br />I S4 GARAG <br />8'x7' GARAGE OOR <br />111 All <br />1ST FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y"=f'-0" <br />D1 <br />STONE <br />V-8" VENEER <br />8'-8" 18'-8" _ <br />I <br />in <br />I <br />v <br />FILLED CELL LEGEND. <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />F_ - - - - - � <br />2ND FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y4'=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />+29.7 ! -32.2 © +29.7 / -39.7 <br />© +28.3 / -30.8 O +28.3 / -37.0 <br />�E +26.6 / -29.1 +26.6 / -33.5 <br />GO SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />[SOFFIT DESIGN PRESSURE +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed, or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14, <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME.WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />A G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />o <br />N <br />�; <br />d CV Y <br />3 '- <br />ao co W <br />v <br />':0 CD <br />0 <br />M <br />0 <br />N <br />�. N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />��n��+t <br />o R 8 "o - <br />y <br />0 <br />0 +�+ C J # <br />_ J <br />�° u; W <br />B1i �M� 3 w a a <br />a J LD. Z <br />L LL <br />zZ Z <br />Z �oIL Y.fl <br />W 15 00NCD m W <br />' m Z <br />W <br />N m Z O <br />Z OU ❑❑❑ <br />ui <br />N M <br />10 <br />o g <br />< N <br />� o � <br />U) V) <br />M <br />� o <br />4 <br />O�, o <br />�L41)LU <br />� in <br />EOf <br />z� <br />< r <br />N Ol <br />o W <br />w <br />z <br />M 20 Q <br />u- E <br />�o <� <br />ECo <br />® oa <br />H rCS xo -O <br />&¢ S< <br />® E �z ,Z <br />h <br />o <br />'� a. m� <br />`! CC: U Oco <br />Z OF <br />Z <br />to 'S go <br />a� d <br />ZU <br />o <br />o w< 0 <br />zk <br />I a <br />d 3 <br />c <br />r <br />> 00 <br />CN <br />rn <br />CV N <br />M CO r r- <br />L CV NT <br />�_ o r <br />O0 m T <br />•- N <br />p � <br />S.� M � <br />Co O <br />C-9 OO r <br />aS N d <br />W 3 <br />c E 1"- c <br />E <br />ll U J Q Q J <br />JOB NO: 23-12160-12165 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />WINDOW SCHEDULE <br />R.O. CMU R.O. FRAME <br />SIZE (Flange) (Fin) TYPE <br />12 20 X 26 18 J X 25 i S.H. <br />13 20 X 381 18 J X 3711 S.H. <br />14 20X501 182'X50 S.H. <br />15 20X63 18JX62i S.H. <br />16 20X72 1817X71 S.H. <br />1 H2 27 1/4 X 26 26 X 25 S.H. <br />1H3 271/4X381 26x37�q S.H. <br />1 H4 27 a X 50 1 26 x 50 S.H. <br />1H5 27JX63 26X621/2 S.H. <br />1H6 27,X72 26X711/2 S.H. <br />22 37JX26 36JX251/2 S.H. <br />23 37 J X 38 i 36 J X 37 3/4 S.H. <br />24 37 J X 501 36 71 X 50 S.H. <br />25 37 J X 63 36 J X 62 1/2 S.H. <br />26 37 J X 72 36 4 X 71 1/2 S.H. <br />DOUBLE 2 WIDE 75" TALL 73 J WIDE S.H. <br />32 54 X 26 52 J X 25 i S.H. <br />33 54 X 38 J 52 J X 37 i S.H. <br />34 54 X 50 J 52 4 X 50 S.H. <br />35 54 X 63 52 J X 62 J S.H. <br />36 54 X 72 52 J X 714 S.H. <br />39X59 40 X 59 N/A S.H. <br />DOUBLE 39X59 79 X 59 N/A S.H. <br />(2) 2X8 w/ 1/2" <br />FLITCH HEADER <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL. _ <br />DRYWALL <br />1 1/2" MIN. CLEARANCE <br />1 1/4" TO 2" DIA <br />HANDRAIL NO <br />LESS THAN 34 <br />NOR MORE <br />THAN 38" ABV. <br />TREAD NOSING <br />METAL <br />HANDRAIL <br />BRACKET <br />BLOCKING AS <br />REQUIRED <br />Q <br />U Q <br />:- <br />w U <br />Z <br />W <br />J <br />0 <br />� <br />w <br />x <br />z <br />F. FL. HANDRAIL DETAIL <br />2x4 #2 SYP. P.T. THRUST SCALE: 3" =1'-0" <br />BLOCK W/(2)-14x 31/2" <br />TAPCONS @ 16"o.c. AND <br />3" FROM EA. END. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the waikline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '/2 inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 318 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />13'-4" 3'-8" <br />10 <br />VERIFY <br />[ACC PAD LOCATION OF <br />A/C PAD <br />HB <br />A OUTDOOR LIVING <br />S3 9'-4" CLG. A.F.F. <br />CONCRETE <br />6068 SGD <br />7'-11" <br />M © � <br />M <br />DINING <br />9'4' FLAT CLG. <br />® TILE <br />00 <br />o - <br />Y <br />i0 <br />LO <br />FLRG. LINE <br />8,-0„ <br />® czn <br />10 N <br />C9 <br />a; - ED1 <br />0 M <br />. TYP. U. <br />_. O <br />co <br />(V <br />in <br />STONE <br />VENEER <br />d 16" SQUARE- <br />CMU COLUMN <br />I <br />3068 <br />5-SH NJ <br />2468 REF <br />I <br />6'-7" ' <br />o I <br />O <br />O <br />I <br />cw7 110 <br />KITCHEN Q ' <br />9'-4" FLAT CLG, m I <br />TILE <br />t <br />SINK w/ <br />D/W DISPOSAL <br />1 I oo r._ J <br />T) 16" CNTR. AT 42" <br />A.F.F. <br />3'-8" <br />0 <br />10 <br />1/2 WALL <br />CAPPED <br />f <br />II UP <br /><V <br />GREAT ROOM <br />9'-4" FLAT CLG. <br />CARPET <br />2'-4" 4'-8" <br />-. <br />EN Y <br />9'-4" FLG. A.F.F. <br />CONCRETE <br />co O <br />f � <br />o - <br />in <br />00 <br />f <br />00 <br />HB <br />00 0 <br />EO <br />ir) <br />0 <br />CV <br />V-4" 5'-8" 111-81, <br />GG <br />S3 <br />4'-4" <br />' • T <br />1 <br />!r �® 1 <br />i G <br />® Y <br />Cp, <br />`~I W.H <br />BUILDER TO <br />PROVIDE <br />APPLIANCE <br />PROTECTION <br />WHEN <br />REQUIRED PER <br />FBC <br />1-CAR ARAGE <br />9'4" FLAT CLG. <br />r- - - - - - - - - - ------i <br />I I <br />I I <br />I I <br />LINE OF 2nd STRY. ABV. <br />-*NOTE` I <br />BLK. WALLS ARE 8'-8" <br />TALL FOR "A" NIT 5-8" <br />FROM FRO14T OF <br />GARA E <br />K TYP. @ I <br />I S4 GARAG <br />8'x7' GARAGE OOR <br />111 All <br />1ST FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y"=f'-0" <br />D1 <br />STONE <br />V-8" VENEER <br />8'-8" 18'-8" _ <br />I <br />in <br />I <br />v <br />FILLED CELL LEGEND. <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />F_ - - - - - � <br />2ND FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y4'=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />+29.7 ! -32.2 © +29.7 / -39.7 <br />© +28.3 / -30.8 O +28.3 / -37.0 <br />�E +26.6 / -29.1 +26.6 / -33.5 <br />GO SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />[SOFFIT DESIGN PRESSURE +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed, or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14, <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME.WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />A G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />o <br />N <br />�; <br />d CV Y <br />3 '- <br />ao co W <br />v <br />':0 CD <br />0 <br />M <br />0 <br />N <br />�. N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />��n��+t <br />o R 8 "o - <br />y <br />0 <br />0 +�+ C J # <br />_ J <br />�° u; W <br />B1i �M� 3 w a a <br />a J LD. Z <br />L LL <br />zZ Z <br />Z �oIL Y.fl <br />W 15 00NCD m W <br />' m Z <br />W <br />N m Z O <br />Z OU ❑❑❑ <br />ui <br />N M <br />10 <br />o g <br />< N <br />� o � <br />U) V) <br />M <br />� o <br />4 <br />O�, o <br />�L41)LU <br />� in <br />EOf <br />z� <br />< r <br />N Ol <br />o W <br />w <br />z <br />M 20 Q <br />u- E <br />�o <� <br />ECo <br />® oa <br />H rCS xo -O <br />&¢ S< <br />® E �z ,Z <br />h <br />o <br />'� a. m� <br />`! CC: U Oco <br />Z OF <br />Z <br />to 'S go <br />a� d <br />ZU <br />o <br />o w< 0 <br />zk <br />I a <br />d 3 <br />c <br />r <br />> 00 <br />CN <br />rn <br />CV N <br />M CO r r- <br />L CV NT <br />�_ o r <br />O0 m T <br />•- N <br />p � <br />S.� M � <br />Co O <br />C-9 OO r <br />aS N d <br />W 3 <br />c E 1"- c <br />E <br />ll U J Q Q J <br />JOB NO: 23-12160-12165 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />(2) 2X8 w/ 1/2" <br />FLITCH HEADER <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL. _ <br />DRYWALL <br />1 1/2" MIN. CLEARANCE <br />1 1/4" TO 2" DIA <br />HANDRAIL NO <br />LESS THAN 34 <br />NOR MORE <br />THAN 38" ABV. <br />TREAD NOSING <br />METAL <br />HANDRAIL <br />BRACKET <br />BLOCKING AS <br />REQUIRED <br />Q <br />U Q <br />:- <br />w U <br />Z <br />W <br />J <br />0 <br />� <br />w <br />x <br />z <br />F. FL. HANDRAIL DETAIL <br />2x4 #2 SYP. P.T. THRUST SCALE: 3" =1'-0" <br />BLOCK W/(2)-14x 31/2" <br />TAPCONS @ 16"o.c. AND <br />3" FROM EA. END. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the waikline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '/2 inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 318 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />13'-4" 3'-8" <br />10 <br />VERIFY <br />[ACC PAD LOCATION OF <br />A/C PAD <br />HB <br />A OUTDOOR LIVING <br />S3 9'-4" CLG. A.F.F. <br />CONCRETE <br />6068 SGD <br />7'-11" <br />M © � <br />M <br />DINING <br />9'4' FLAT CLG. <br />® TILE <br />00 <br />o - <br />Y <br />i0 <br />LO <br />FLRG. LINE <br />8,-0„ <br />® czn <br />10 N <br />C9 <br />a; - ED1 <br />0 M <br />. TYP. U. <br />_. O <br />co <br />(V <br />in <br />STONE <br />VENEER <br />d 16" SQUARE- <br />CMU COLUMN <br />I <br />3068 <br />5-SH NJ <br />2468 REF <br />I <br />6'-7" ' <br />o I <br />O <br />O <br />I <br />cw7 110 <br />KITCHEN Q ' <br />9'-4" FLAT CLG, m I <br />TILE <br />t <br />SINK w/ <br />D/W DISPOSAL <br />1 I oo r._ J <br />T) 16" CNTR. AT 42" <br />A.F.F. <br />3'-8" <br />0 <br />10 <br />1/2 WALL <br />CAPPED <br />f <br />II UP <br /><V <br />GREAT ROOM <br />9'-4" FLAT CLG. <br />CARPET <br />2'-4" 4'-8" <br />-. <br />EN Y <br />9'-4" FLG. A.F.F. <br />CONCRETE <br />co O <br />f � <br />o - <br />in <br />00 <br />f <br />00 <br />HB <br />00 0 <br />EO <br />ir) <br />0 <br />CV <br />V-4" 5'-8" 111-81, <br />GG <br />S3 <br />4'-4" <br />' • T <br />1 <br />!r �® 1 <br />i G <br />® Y <br />Cp, <br />`~I W.H <br />BUILDER TO <br />PROVIDE <br />APPLIANCE <br />PROTECTION <br />WHEN <br />REQUIRED PER <br />FBC <br />1-CAR ARAGE <br />9'4" FLAT CLG. <br />r- - - - - - - - - - ------i <br />I I <br />I I <br />I I <br />LINE OF 2nd STRY. ABV. <br />-*NOTE` I <br />BLK. WALLS ARE 8'-8" <br />TALL FOR "A" NIT 5-8" <br />FROM FRO14T OF <br />GARA E <br />K TYP. @ I <br />I S4 GARAG <br />8'x7' GARAGE OOR <br />111 All <br />1ST FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y"=f'-0" <br />D1 <br />STONE <br />V-8" VENEER <br />8'-8" 18'-8" _ <br />I <br />in <br />I <br />v <br />FILLED CELL LEGEND. <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />F_ - - - - - � <br />2ND FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y4'=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />+29.7 ! -32.2 © +29.7 / -39.7 <br />© +28.3 / -30.8 O +28.3 / -37.0 <br />�E +26.6 / -29.1 +26.6 / -33.5 <br />GO SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />[SOFFIT DESIGN PRESSURE +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed, or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14, <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME.WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />A G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />o <br />N <br />�; <br />d CV Y <br />3 '- <br />ao co W <br />v <br />':0 CD <br />0 <br />M <br />0 <br />N <br />�. N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />��n��+t <br />o R 8 "o - <br />y <br />0 <br />0 +�+ C J # <br />_ J <br />�° u; W <br />B1i �M� 3 w a a <br />a J LD. Z <br />L LL <br />zZ Z <br />Z �oIL Y.fl <br />W 15 00NCD m W <br />' m Z <br />W <br />N m Z O <br />Z OU ❑❑❑ <br />ui <br />N M <br />10 <br />o g <br />< N <br />� o � <br />U) V) <br />M <br />� o <br />4 <br />O�, o <br />�L41)LU <br />� in <br />EOf <br />z� <br />< r <br />N Ol <br />o W <br />w <br />z <br />M 20 Q <br />u- E <br />�o <� <br />ECo <br />® oa <br />H rCS xo -O <br />&¢ S< <br />® E �z ,Z <br />h <br />o <br />'� a. m� <br />`! CC: U Oco <br />Z OF <br />Z <br />to 'S go <br />a� d <br />ZU <br />o <br />o w< 0 <br />zk <br />I a <br />d 3 <br />c <br />r <br />> 00 <br />CN <br />rn <br />CV N <br />M CO r r- <br />L CV NT <br />�_ o r <br />O0 m T <br />•- N <br />p � <br />S.� M � <br />Co O <br />C-9 OO r <br />aS N d <br />W 3 <br />c E 1"- c <br />E <br />ll U J Q Q J <br />JOB NO: 23-12160-12165 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />2x4 #2 SYP. P.T. THRUST SCALE: 3" =1'-0" <br />BLOCK W/(2)-14x 31/2" <br />TAPCONS @ 16"o.c. AND <br />3" FROM EA. END. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the waikline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '/2 inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 318 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />13'-4" 3'-8" <br />10 <br />VERIFY <br />[ACC PAD LOCATION OF <br />A/C PAD <br />HB <br />A OUTDOOR LIVING <br />S3 9'-4" CLG. A.F.F. <br />CONCRETE <br />6068 SGD <br />7'-11" <br />M © � <br />M <br />DINING <br />9'4' FLAT CLG. <br />® TILE <br />00 <br />o - <br />Y <br />i0 <br />LO <br />FLRG. LINE <br />8,-0„ <br />® czn <br />10 N <br />C9 <br />a; - ED1 <br />0 M <br />. TYP. U. <br />_. O <br />co <br />(V <br />in <br />STONE <br />VENEER <br />d 16" SQUARE- <br />CMU COLUMN <br />I <br />3068 <br />5-SH NJ <br />2468 REF <br />I <br />6'-7" ' <br />o I <br />O <br />O <br />I <br />cw7 110 <br />KITCHEN Q ' <br />9'-4" FLAT CLG, m I <br />TILE <br />t <br />SINK w/ <br />D/W DISPOSAL <br />1 I oo r._ J <br />T) 16" CNTR. AT 42" <br />A.F.F. <br />3'-8" <br />0 <br />10 <br />1/2 WALL <br />CAPPED <br />f <br />II UP <br /><V <br />GREAT ROOM <br />9'-4" FLAT CLG. <br />CARPET <br />2'-4" 4'-8" <br />-. <br />EN Y <br />9'-4" FLG. A.F.F. <br />CONCRETE <br />co O <br />f � <br />o - <br />in <br />00 <br />f <br />00 <br />HB <br />00 0 <br />EO <br />ir) <br />0 <br />CV <br />V-4" 5'-8" 111-81, <br />GG <br />S3 <br />4'-4" <br />' • T <br />1 <br />!r �® 1 <br />i G <br />® Y <br />Cp, <br />`~I W.H <br />BUILDER TO <br />PROVIDE <br />APPLIANCE <br />PROTECTION <br />WHEN <br />REQUIRED PER <br />FBC <br />1-CAR ARAGE <br />9'4" FLAT CLG. <br />r- - - - - - - - - - ------i <br />I I <br />I I <br />I I <br />LINE OF 2nd STRY. ABV. <br />-*NOTE` I <br />BLK. WALLS ARE 8'-8" <br />TALL FOR "A" NIT 5-8" <br />FROM FRO14T OF <br />GARA E <br />K TYP. @ I <br />I S4 GARAG <br />8'x7' GARAGE OOR <br />111 All <br />1ST FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y"=f'-0" <br />D1 <br />STONE <br />V-8" VENEER <br />8'-8" 18'-8" _ <br />I <br />in <br />I <br />v <br />FILLED CELL LEGEND. <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />F_ - - - - - � <br />2ND FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y4'=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />+29.7 ! -32.2 © +29.7 / -39.7 <br />© +28.3 / -30.8 O +28.3 / -37.0 <br />�E +26.6 / -29.1 +26.6 / -33.5 <br />GO SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />[SOFFIT DESIGN PRESSURE +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed, or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14, <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME.WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />A G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />o <br />N <br />�; <br />d CV Y <br />3 '- <br />ao co W <br />v <br />':0 CD <br />0 <br />M <br />0 <br />N <br />�. N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />��n��+t <br />o R 8 "o - <br />y <br />0 <br />0 +�+ C J # <br />_ J <br />�° u; W <br />B1i �M� 3 w a a <br />a J LD. Z <br />L LL <br />zZ Z <br />Z �oIL Y.fl <br />W 15 00NCD m W <br />' m Z <br />W <br />N m Z O <br />Z OU ❑❑❑ <br />ui <br />N M <br />10 <br />o g <br />< N <br />� o � <br />U) V) <br />M <br />� o <br />4 <br />O�, o <br />�L41)LU <br />� in <br />EOf <br />z� <br />< r <br />N Ol <br />o W <br />w <br />z <br />M 20 Q <br />u- E <br />�o <� <br />ECo <br />® oa <br />H rCS xo -O <br />&¢ S< <br />® E �z ,Z <br />h <br />o <br />'� a. m� <br />`! CC: U Oco <br />Z OF <br />Z <br />to 'S go <br />a� d <br />ZU <br />o <br />o w< 0 <br />zk <br />I a <br />d 3 <br />c <br />r <br />> 00 <br />CN <br />rn <br />CV N <br />M CO r r- <br />L CV NT <br />�_ o r <br />O0 m T <br />•- N <br />p � <br />S.� M � <br />Co O <br />C-9 OO r <br />aS N d <br />W 3 <br />c E 1"- c <br />E <br />ll U J Q Q J <br />JOB NO: 23-12160-12165 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />T) 16" CNTR. AT 42" <br />A.F.F. <br />3'-8" <br />0 <br />10 <br />1/2 WALL <br />CAPPED <br />f <br />II UP <br /><V <br />GREAT ROOM <br />9'-4" FLAT CLG. <br />CARPET <br />2'-4" 4'-8" <br />-. <br />EN Y <br />9'-4" FLG. A.F.F. <br />CONCRETE <br />co O <br />f � <br />o - <br />in <br />00 <br />f <br />00 <br />HB <br />00 0 <br />EO <br />ir) <br />0 <br />CV <br />V-4" 5'-8" 111-81, <br />GG <br />S3 <br />4'-4" <br />' • T <br />1 <br />!r �® 1 <br />i G <br />® Y <br />Cp, <br />`~I W.H <br />BUILDER TO <br />PROVIDE <br />APPLIANCE <br />PROTECTION <br />WHEN <br />REQUIRED PER <br />FBC <br />1-CAR ARAGE <br />9'4" FLAT CLG. <br />r- - - - - - - - - - ------i <br />I I <br />I I <br />I I <br />LINE OF 2nd STRY. ABV. <br />-*NOTE` I <br />BLK. WALLS ARE 8'-8" <br />TALL FOR "A" NIT 5-8" <br />FROM FRO14T OF <br />GARA E <br />K TYP. @ I <br />I S4 GARAG <br />8'x7' GARAGE OOR <br />111 All <br />1ST FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y"=f'-0" <br />D1 <br />STONE <br />V-8" VENEER <br />8'-8" 18'-8" _ <br />I <br />in <br />I <br />v <br />FILLED CELL LEGEND. <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />F_ - - - - - � <br />2ND FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y4'=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />+29.7 ! -32.2 © +29.7 / -39.7 <br />© +28.3 / -30.8 O +28.3 / -37.0 <br />�E +26.6 / -29.1 +26.6 / -33.5 <br />GO SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />[SOFFIT DESIGN PRESSURE +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed, or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14, <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME.WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />A G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />o <br />N <br />�; <br />d CV Y <br />3 '- <br />ao co W <br />v <br />':0 CD <br />0 <br />M <br />0 <br />N <br />�. N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />��n��+t <br />o R 8 "o - <br />y <br />0 <br />0 +�+ C J # <br />_ J <br />�° u; W <br />B1i �M� 3 w a a <br />a J LD. Z <br />L LL <br />zZ Z <br />Z �oIL Y.fl <br />W 15 00NCD m W <br />' m Z <br />W <br />N m Z O <br />Z OU ❑❑❑ <br />ui <br />N M <br />10 <br />o g <br />< N <br />� o � <br />U) V) <br />M <br />� o <br />4 <br />O�, o <br />�L41)LU <br />� in <br />EOf <br />z� <br />< r <br />N Ol <br />o W <br />w <br />z <br />M 20 Q <br />u- E <br />�o <� <br />ECo <br />® oa <br />H rCS xo -O <br />&¢ S< <br />® E �z ,Z <br />h <br />o <br />'� a. m� <br />`! CC: U Oco <br />Z OF <br />Z <br />to 'S go <br />a� d <br />ZU <br />o <br />o w< 0 <br />zk <br />I a <br />d 3 <br />c <br />r <br />> 00 <br />CN <br />rn <br />CV N <br />M CO r r- <br />L CV NT <br />�_ o r <br />O0 m T <br />•- N <br />p � <br />S.� M � <br />Co O <br />C-9 OO r <br />aS N d <br />W 3 <br />c E 1"- c <br />E <br />ll U J Q Q J <br />JOB NO: 23-12160-12165 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />GG <br />S3 <br />4'-4" <br />' • T <br />1 <br />!r �® 1 <br />i G <br />® Y <br />Cp, <br />`~I W.H <br />BUILDER TO <br />PROVIDE <br />APPLIANCE <br />PROTECTION <br />WHEN <br />REQUIRED PER <br />FBC <br />1-CAR ARAGE <br />9'4" FLAT CLG. <br />r- - - - - - - - - - ------i <br />I I <br />I I <br />I I <br />LINE OF 2nd STRY. ABV. <br />-*NOTE` I <br />BLK. WALLS ARE 8'-8" <br />TALL FOR "A" NIT 5-8" <br />FROM FRO14T OF <br />GARA E <br />K TYP. @ I <br />I S4 GARAG <br />8'x7' GARAGE OOR <br />111 All <br />1ST FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y"=f'-0" <br />D1 <br />STONE <br />V-8" VENEER <br />8'-8" 18'-8" _ <br />I <br />in <br />I <br />v <br />FILLED CELL LEGEND. <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />F_ - - - - - � <br />2ND FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y4'=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />+29.7 ! -32.2 © +29.7 / -39.7 <br />© +28.3 / -30.8 O +28.3 / -37.0 <br />�E +26.6 / -29.1 +26.6 / -33.5 <br />GO SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />[SOFFIT DESIGN PRESSURE +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed, or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14, <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME.WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />A G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />o <br />N <br />�; <br />d CV Y <br />3 '- <br />ao co W <br />v <br />':0 CD <br />0 <br />M <br />0 <br />N <br />�. N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />��n��+t <br />o R 8 "o - <br />y <br />0 <br />0 +�+ C J # <br />_ J <br />�° u; W <br />B1i �M� 3 w a a <br />a J LD. Z <br />L LL <br />zZ Z <br />Z �oIL Y.fl <br />W 15 00NCD m W <br />' m Z <br />W <br />N m Z O <br />Z OU ❑❑❑ <br />ui <br />N M <br />10 <br />o g <br />< N <br />� o � <br />U) V) <br />M <br />� o <br />4 <br />O�, o <br />�L41)LU <br />� in <br />EOf <br />z� <br />< r <br />N Ol <br />o W <br />w <br />z <br />M 20 Q <br />u- E <br />�o <� <br />ECo <br />® oa <br />H rCS xo -O <br />&¢ S< <br />® E �z ,Z <br />h <br />o <br />'� a. m� <br />`! CC: U Oco <br />Z OF <br />Z <br />to 'S go <br />a� d <br />ZU <br />o <br />o w< 0 <br />zk <br />I a <br />d 3 <br />c <br />r <br />> 00 <br />CN <br />rn <br />CV N <br />M CO r r- <br />L CV NT <br />�_ o r <br />O0 m T <br />•- N <br />p � <br />S.� M � <br />Co O <br />C-9 OO r <br />aS N d <br />W 3 <br />c E 1"- c <br />E <br />ll U J Q Q J <br />JOB NO: 23-12160-12165 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />`~I W.H <br />BUILDER TO <br />PROVIDE <br />APPLIANCE <br />PROTECTION <br />WHEN <br />REQUIRED PER <br />FBC <br />1-CAR ARAGE <br />9'4" FLAT CLG. <br />r- - - - - - - - - - ------i <br />I I <br />I I <br />I I <br />LINE OF 2nd STRY. ABV. <br />-*NOTE` I <br />BLK. WALLS ARE 8'-8" <br />TALL FOR "A" NIT 5-8" <br />FROM FRO14T OF <br />GARA E <br />K TYP. @ I <br />I S4 GARAG <br />8'x7' GARAGE OOR <br />111 All <br />1ST FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y"=f'-0" <br />D1 <br />STONE <br />V-8" VENEER <br />8'-8" 18'-8" _ <br />I <br />in <br />I <br />v <br />FILLED CELL LEGEND. <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />F_ - - - - - � <br />2ND FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y4'=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />+29.7 ! -32.2 © +29.7 / -39.7 <br />© +28.3 / -30.8 O +28.3 / -37.0 <br />�E +26.6 / -29.1 +26.6 / -33.5 <br />GO SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />[SOFFIT DESIGN PRESSURE +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed, or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14, <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME.WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />A G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />o <br />N <br />�; <br />d CV Y <br />3 '- <br />ao co W <br />v <br />':0 CD <br />0 <br />M <br />0 <br />N <br />�. N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />��n��+t <br />o R 8 "o - <br />y <br />0 <br />0 +�+ C J # <br />_ J <br />�° u; W <br />B1i �M� 3 w a a <br />a J LD. Z <br />L LL <br />zZ Z <br />Z �oIL Y.fl <br />W 15 00NCD m W <br />' m Z <br />W <br />N m Z O <br />Z OU ❑❑❑ <br />ui <br />N M <br />10 <br />o g <br />< N <br />� o � <br />U) V) <br />M <br />� o <br />4 <br />O�, o <br />�L41)LU <br />� in <br />EOf <br />z� <br />< r <br />N Ol <br />o W <br />w <br />z <br />M 20 Q <br />u- E <br />�o <� <br />ECo <br />® oa <br />H rCS xo -O <br />&¢ S< <br />® E �z ,Z <br />h <br />o <br />'� a. m� <br />`! CC: U Oco <br />Z OF <br />Z <br />to 'S go <br />a� d <br />ZU <br />o <br />o w< 0 <br />zk <br />I a <br />d 3 <br />c <br />r <br />> 00 <br />CN <br />rn <br />CV N <br />M CO r r- <br />L CV NT <br />�_ o r <br />O0 m T <br />•- N <br />p � <br />S.� M � <br />Co O <br />C-9 OO r <br />aS N d <br />W 3 <br />c E 1"- c <br />E <br />ll U J Q Q J <br />JOB NO: 23-12160-12165 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />1ST FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y"=f'-0" <br />D1 <br />STONE <br />V-8" VENEER <br />8'-8" 18'-8" _ <br />I <br />in <br />I <br />v <br />FILLED CELL LEGEND. <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />F_ - - - - - � <br />2ND FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y4'=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />+29.7 ! -32.2 © +29.7 / -39.7 <br />© +28.3 / -30.8 O +28.3 / -37.0 <br />�E +26.6 / -29.1 +26.6 / -33.5 <br />GO SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />[SOFFIT DESIGN PRESSURE +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed, or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14, <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME.WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />A G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />o <br />N <br />�; <br />d CV Y <br />3 '- <br />ao co W <br />v <br />':0 CD <br />0 <br />M <br />0 <br />N <br />�. N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />��n��+t <br />o R 8 "o - <br />y <br />0 <br />0 +�+ C J # <br />_ J <br />�° u; W <br />B1i �M� 3 w a a <br />a J LD. Z <br />L LL <br />zZ Z <br />Z �oIL Y.fl <br />W 15 00NCD m W <br />' m Z <br />W <br />N m Z O <br />Z OU ❑❑❑ <br />ui <br />N M <br />10 <br />o g <br />< N <br />� o � <br />U) V) <br />M <br />� o <br />4 <br />O�, o <br />�L41)LU <br />� in <br />EOf <br />z� <br />< r <br />N Ol <br />o W <br />w <br />z <br />M 20 Q <br />u- E <br />�o <� <br />ECo <br />® oa <br />H rCS xo -O <br />&¢ S< <br />® E �z ,Z <br />h <br />o <br />'� a. m� <br />`! CC: U Oco <br />Z OF <br />Z <br />to 'S go <br />a� d <br />ZU <br />o <br />o w< 0 <br />zk <br />I a <br />d 3 <br />c <br />r <br />> 00 <br />CN <br />rn <br />CV N <br />M CO r r- <br />L CV NT <br />�_ o r <br />O0 m T <br />•- N <br />p � <br />S.� M � <br />Co O <br />C-9 OO r <br />aS N d <br />W 3 <br />c E 1"- c <br />E <br />ll U J Q Q J <br />JOB NO: 23-12160-12165 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed, or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14, <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME.WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />A G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />o <br />N <br />�; <br />d CV Y <br />3 '- <br />ao co W <br />v <br />':0 CD <br />0 <br />M <br />0 <br />N <br />�. N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />��n��+t <br />o R 8 "o - <br />y <br />0 <br />0 +�+ C J # <br />_ J <br />�° u; W <br />B1i �M� 3 w a a <br />a J LD. Z <br />L LL <br />zZ Z <br />Z �oIL Y.fl <br />W 15 00NCD m W <br />' m Z <br />W <br />N m Z O <br />Z OU ❑❑❑ <br />ui <br />N M <br />10 <br />o g <br />< N <br />� o � <br />U) V) <br />M <br />� o <br />4 <br />O�, o <br />�L41)LU <br />� in <br />EOf <br />z� <br />< r <br />N Ol <br />o W <br />w <br />z <br />M 20 Q <br />u- E <br />�o <� <br />ECo <br />® oa <br />H rCS xo -O <br />&¢ S< <br />® E �z ,Z <br />h <br />o <br />'� a. m� <br />`! CC: U Oco <br />Z OF <br />Z <br />to 'S go <br />a� d <br />ZU <br />o <br />o w< 0 <br />zk <br />I a <br />d 3 <br />c <br />r <br />> 00 <br />CN <br />rn <br />CV N <br />M CO r r- <br />L CV NT <br />�_ o r <br />O0 m T <br />•- N <br />p � <br />S.� M � <br />Co O <br />C-9 OO r <br />aS N d <br />W 3 <br />c E 1"- c <br />E <br />ll U J Q Q J <br />JOB NO: 23-12160-12165 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />