My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36362 Flats St
Zephyrhills
>
Building Department
>
Building Plans
>
36362 Flats St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 1:45:13 PM
Creation date
2/19/2025 8:14:42 AM
Metadata
Fields
Template:
Building Plans
Street #
36362
Location
Flats St
Contractor
Lennar Homes
Building Plans - Permit #
6297
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br />_ <br />C� <br />Q <br />v <br />M <br />t�D <br />J <br />LO <br />CD <br />0 <br />rI <br />0 <br />Cro <br />0 <br />to <br />J <br />LO <br />0 <br />I <br />N <br />0 <br />d- <br />L <br />Cl�Y <br />L <br />a <br />N <br />N <br />0 <br />E <br />V <br />E <br />0 <br />_ <br />i <br />0 <br />v <br />0 <br />J <br />LZ <br />N <br />N <br />a <br />0 <br />a_ <br />to <br />O <br />i <br />a <br />a <br />0 <br />U <br />o. <br />Q <br />9 <br />0 <br />THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT AT <br />4) SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />`' MASONRY <br />WINDOW BUCK2) <br />c <br />SEALANT JOINT <br />5) SEALANT FROM <br />NSIDE EDGE OF <br />WINDOW FRAME <br />WINDOW BUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />ATTACHED <br />PER CODE <br />6) TOOLED SEALANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME TI <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL, <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />SCS 06_02 WINDOW FIN INTERFACE WITH <br />EXTRUDED SHOULDER <br />WEATHER <br />`RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTI( <br />1. Cut, fold up & temporarily secure 1 <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NITS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING y <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL O <br />COMPATIBILITY <br />SELF -ADHERED FLASHING <br />'"I WEATHER <br />JE BARRIER & <br />ZARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHING <br />SHEATHING BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI; <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />YL SELF -ADHERED FLASHING <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID <br />NAIL BRAND OR EQUAL WEATHER <br />y O PROOF CAULKING <br />SELF -ADHERED FLASHING <br />OR <br />1 <br />SUBFLC <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING , <br />SECTION -A (SEE DETAIL <br />NAILING FLANGE SELF -ADHERED FLASHING- <br />1 <br />DO NOT FLASH OVER 2 SEAL TOPS OF JOISTS <br />BOTTOM NAILING UNDER DECKING <br />(SEE DETAIL WP07) <br />FLANGE <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING <br />HALF ROUND WINDOW I EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as( in each detail that corresponds to the <br />numbered items in the list o instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />2x FRAMEWALL <br />TILE FINISH- <br />1/2" DUROCK- <br />8" CMU <br />4"OR8"CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD BED - <br />VINYL SHOWER PAN <br />v <br />2 <br />1'4' PER PLAN <br />SHOWER SEAT <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />:LF-ADHERED FLASHING <br />TCH <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />tia <br />PLASTER STOP - <br />CONTINUOUS BACKER - <br />ROD & SEALANT <br />A <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />SLOPE <br />0.3 in: 12.0 in <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />(0.6 cm: 30.5 cm) <br />include flashing as described in Section R703.4. <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />CEMT. FIN. <br />water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />BUILDING PAPER <br />of draining to the exterior water that penetrates the exterior cladding. <br />WIRE LATH <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied <br />-i <br />4 <br />horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />- -= <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions, The <br />/ <br />No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />O <br />D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />Lim <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />substantially nonwater-absorbing layer or designed drainage space. <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RUBBERIZED <br />NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />THROUGH SELF -ADHERED <br />R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />FLASHING SELF -ADHERED FLASHING <br />applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />SCORED <br />prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />(BEFORE FOLDING SCORE <br />the buildingwall with a sealant complyingwith AAMA 800 or ASTM C920 Class 25 Grade NS rester for proper joint expansion and <br />or g p p p <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />shall be installed at the following locations: <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />2 <br />following. <br />5 <br />1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />6 <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />7 <br />subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />SELF -ADHERED FLASHING <br />1.3 1.3. In accordance with other approved methods. <br />INSIDE CORNER �' <br />1.4 In accordance with FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6.6.At wall and roof intersections. <br />Water Resistant Barrier <br />7.7.At built-in putters. <br />a <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS <br />NATU <br />DO NI <br />DRIP <br />ACCE <br />SOFFIT/CANTILEVER <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) o <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING, 'OSB% PLYWOOD, DENSGLASS <br />FRAMING <br />SHEATHING <br />ANE WRB <br />WRB <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />t" <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Metal <br />.. <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 112"to 2" <br />Above Roof <br />Sheathing <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />_Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />CM <br />0 <br />' <br />�. <br />' o <br />� <br />- a 04 <br />WCCD <br />C <br />�.� 2® <br />o <br />v <br />w <br />M <br />O <br />CV <br />O <br />o <br />`l <br />vl <br />- l <br />z � <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal, <br />W <br />a <br />o cq <br />V 00 <br />0 N N 0 <br />N m G # <br />0 <br />0 <br />_ °° <br />coM0� u. <br />M <br />13 Q <br />o- a <br />-U i z <br />Z <br />r q X <br />� <br />y o <br />� @n m m � m <br />Z <br />LW <br />0�� o X o <br />n Nz <br />;n <br />a rJ = <br />N CO Q 6 0 F <br />Z <br />O U ❑0� <br />W <br />V M � <br />z M- <br />0 00 <br />z N <br />z o� <br />� <br />Z <br />(Do <br />0 <br />W <br />� <br />- <br />W <br />0 <br />V) <br />�N <br />= <br />) <br />Bigw <br />� <br />T- L <br />I <br />i <br />U ) <br />m <br />Q m 0 <br />N O <br />i <br />to <br />o <br />C.0 <br />J <br />w <br />M <br />y ¢ <br />2 <br />Z <br />4 <br />L- <br />Q E <br />E: O <br />z o <br />o0 <br />w z <br />Z o <br />QN <br />Z0 <br />0 <br />CU <br />00 <br />E <br />a Z <br />tc'p <br />!� <br />ao <br />az <br />�o <br />W z <br />�I <br />,� <br />r <br /><0 <br />�¢ <br />a�Z� <br />m� <br />0 <br />w <br />Z <br />0 <br />Z <br />8 <br />O <br />�z <br />Q0 <br />Z <br />o� <br />�w <br />0 <br />m <br />r� <br />0~ <br />J <br />o <br />w <br />>0 <br />v <br />oQ <br />E <br />o� <br />c Q <br />0 <br />� <br />(�o <br />or_ <br />LO <br />L0 <br />m <br />.--. <br />cc <br />Fes- <br />M <br />CD <br />T <br />,- <br />U <br />m <br />W <br />N/� <br />W <br />Li J <br />� <br />U) <br />QI <br />rn M <br />0) <br />o No <br />0 <br />� <br />N <br />� <br />N Li <br />Ln <br />r <br />a <br />N <br />r <br />CD <br />ui <br />E <br />2 <br />E M <br />co <br />o <br />Z <br />Z <br />E 10 <br />co <br />2 <br />m <br />E <br />c <br />n <br />U J <br />Q p <br />J <br />JOB <br />NO: <br />23-03656 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />WP <br />
The URL can be used to link to this page
Your browser does not support the video tag.