THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4"-1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />16GAx1-1/2" LONG (3/4"-1" <br />CROWN) STAPLES @ 6" <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />O O 0 <br />5'-0" Q01 <br />- <br />STUB -OUT FOR 1 '_0'- o o <br />GAS METER 0 O <br />_ � U <br />O � <br />N oz <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />1 T-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />L** NACONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />TOESOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1l8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />2.0 <br />--F90 <br />2 x _lumber <br />Double 2 x _lumber <br />FILL CELL STD. 90° HOOK BOND BEAM <br />Cn <br />7HK <br />CONT. #5 <br />CONT.> BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQA'DPLYWOOD FLOOR <br />COLUMN ANDSHEATHING PER PLAN <br />CONNECTIONTJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. } Small gap 2,' min. <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB we stiffener 2" min. <br />required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than 1Fnnln <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 pif max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />1/16 <br />details in <br />One 10d box <br />areas=20 of high <br />or.=20 sinker <br />lateral load. <br />1 <br />T nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />x j <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" n.c. <br />Provide adequate bearing <br />for each lapped joist. <br />Odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />6,1 A 1/" ROUND HOLE MAY 61 <br />i 6„ DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT 7 ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y2" <br />VA" <br />1-2" <br />1, 2• <br />11'-3' <br />V-3 <br />1'-7 <br />1'-1I <br />2'4' <br />2-9' <br />3-7 <br />3 7' <br />Any 16'joist <br />1'—U' <br />1 1'" <br />1- ' <br />1 2'" <br />1'-3' <br />1' <br />2'-4' <br />2-11° <br />3-7' <br />4-2' <br />4'-9" <br />S'-4.' <br />._ --12 <br />-- � _. --... <br />16 <br />1'-i)" <br />1'-1"" <br />1- 2 <br />1-0 <br />1 _7," <br />- ' <br />3'-2"" <br />3'-10" <br />4-7 <br />9, 7' <br />�„ <br />7 . <br />1' : <br />1' Z" <br />I 2'-a, <br />3-W <br />4-9' <br />4' IY' <br />6-11," <br />6-11" <br />7' 11" <br />&-11," <br />24 <br />1'-U' <br />T-1" <br />1- " <br />1'-3"' <br />2'-6 ° <br />3-7"4'-9',5'-1Q'. <br />7-2* <br />$` 4" <br />1{l' ° <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Web Stiffener Fastener Schedule I <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BC15000s <br />9-V2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BC] 6000s� <br />BC16500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s@ <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90se <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/(22)- <br />NAILS 1 <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />Ice <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />\Install tight to top flange. <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />" depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM) ° <br />° <br />SEE PLAN FOR--'°. ° . • <br />FOUNDATION INFO ` a d' <br />STEM FOUNDATION <br />GRADE <br />0 <br />r—REINF, SEE PLAN <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE PLUMBING LINE <br />PENETRATION <br />--2r- : I <br />O d <br />d <br />G <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />Y 1 7 2023 <br />Virtual Review Assist, Inc. roiled <br />plans Review completed and app <br />for compliance with the lah� px23DD Edi <br />by Debra Anne K <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />4 ° i na G <br />° . <br />a 4 <br />A C G <br />4 <br />q <br />SEE FND. PLN. <br />SIZE & REINF. <br />M <br />CV <br />0 <br />CV <br />0 <br />M <br />0 <br />�344444699kt,+pye <br />rr <br />R '`� . ` ��. � � • t\J to f , �l �` <br />G' No F,17' <br />, 5 <br />s <br />R <br />�a3 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />Em <br />Wp <br />(It E N <br />co <br />` <br />� N <br />N N <br />C <br />COO,) 10, <br />0 <br />N <br />UJ r- r�:12 LJL uu Ll <br />N� v a a <br />a <br />- <br />oU_ a C, <br />t9 <br />11 <br />0�/ <br />0 <br />� o <br />—� zzo. <br />Z <br />2 N� O Y 0 <br />9 <br />tfi <br />w + p <br />� m � V2 m J g <br />Win26'O' <br />J w <br />Z <br />Co 0 O <br />M z <br />N U F <br />U <br />Z <br />O ❑�❑ <br />W <br />N <br />Z N t7 <br />� � <br />Q <br />� <br />V I <br />V) <br />- N <br />M <br />o` <br />L <br />y <br />(n <br />— <br />0Ln <br />�N <br />� <br />cn <br />C6 <br />r— <br />L.LU.L <br />U <br />OJ 0 <br />N <br />-ion <br />o <br />w <br />� <br />M <br />M <br />Z <br />2 <br />Z <br />Z <br />Q <br />W <br />ao <br />� <br />4 0 <br />o- p <br />E <br />w z <br />z <br />6 <br />CL <br />o E <br />�o <br />XU <br />a� <br />00 <br />0) <br />&a <br />Cc>w- <br />t <br />S <br />H <br />W <br />�� <br />a C <br /><om� <br />0 <br />H <br />Z <br />�z <br />� <br />< <br />d <br />ggsT <br />c") <br />� <br />m� <br />� <br />� F <br />a� <br />ter_ <br />�3 <br />o <br />llllllllllll� <br />M <br />zl¢ <br />d IX�' <br />� 3 <br />0� <br />>C.0 <br />J <br />LO <br />LO <br />0 rn <br />m <br />�1 <br />Q <br />Co <br />It <br />U <br />N_ <br />` <br />im <br />C° <br />L0 <br />r <br />; <br />0 <br />Q <br />"' <br />0 <br />cn M <br />M <br />I <br />^ <br />o <br />CD <br />N <br />ai <br />o <br />a. <br />LO o <br />LO <br />M <br />Q <br />M <br />r <br />CD CM <br />w <br />E <br />M <br />o <br />r <br />N <br />z <br />z <br />E 10cn <br />CU <br />c <br />U _J <br />Q ❑ <br />c <br />_I <br />JOB <br />NO: <br />23-02469 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S N 1 <br />