Laserfiche WebLink
_ I 1 _1111 <br />v+ <br />v <br />v- <br />N <br />0 <br />Q <br />0 <br />04 <br />N <br />1 <br />N <br />1`M <br />CV <br />0 <br />rn <br />LO <br />co <br />O <br />I <br />L0 <br />co <br />0 <br />I <br />O <br />v- <br />N <br />Q <br />0 <br />CV <br />I <br />_N <br />I'M <br />CV <br />O <br />J <br />Cr) <br />co <br />0 <br />LO <br />LO <br />L <br />ca <br />0 <br />I <br />v <br />cn� <br />0 <br />3 <br />N <br />0 <br />i <br />a <br />y <br />E <br />O <br />2 <br />0 <br />c <br />c <br />J <br />ti <br />0 <br />U <br />-9 <br />c <br />0 <br />UI <br />y <br />U <br />0 <br />i <br />a <br />c <br />0 <br />a <br />v <br />0 <br />J <br />N <br />N <br />0 <br />v <br />0 <br />O <br />a <br />O <br />cp <br />v <br />0 <br />m <br />v <br />cn <br />THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />II II II <br />Ilk { I[I <br />II {{ II <br />16GAx1-1\2' LONG (3/4'-1 CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN L I. . ►... <br />.. l I I 1 1 .. 16GAxl-1/2" LONG (3/4%1" <br />STUDS (NOTED THUS:-) - OFFSET I I I I I I CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:-) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF I I <br />HOME H C G <br />GARAGE SIDE 0 0 0 <br />6-0" < - <br />STUB -OUT FOR 1'-0" 0 � 9 <br />GAS METER 0 o <br />U <br />O � <br />N = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.811.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8"or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />FILL CELL STD. 900 HOOK BOND BEAM <br />cn <br />w CONT. #5 <br />a STD.90° <br />BAR —� > I HOOK �CONT. #5(�� BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />SIMPSC <br />wl (22) <br />NAILS T <br />5/8"D <br />THRU <br />BOLT <br />R TRUSS <br />'OP PLATE <br />2 X B.U.0 <br />BOND BEAM STEP <br />SCALE: N.T.S. SIMPSON MGT <br />w/(22)10d <br />2nd FLOOR NAILS TYP. <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE SIMPSON META12 / META12 TSS <br />BEARING COLUMN / PLYWOOD FLOOR TYPICAL SIMPSON MGT TO <br />SEE PLAN FORREQ'D SHEATHING PER PLAN BUILT-UP COLUMN DETAIL INSTALLATION @ MID SPAN <br />COLUMN AND <br />CONNECTION %J / TJI TO BE CUT TO ALLOW NOTE: <br />-. FOR BLOCKING/TJI <br />UPLIFT VALUE <br />MASONRY WALL OR <br />IS BASED ON <br />INTERIOR BRG. WALL S.P.F. <br />TJI PER PLAN <br />OTHERWISE SOLID •`:_:' <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR` <br />STUDS LOCATION OF <br />above to bearing below. SECOND H10A <br />° (WHEN <br />DOUBLE JOIST CONSTRUCTION SECTION @ INT. BRG. WALL SIMPSON H10A ) <br />REQUIRED <br />(Not required if both loaded equally from above) N.T.S. ` = w/ (18)10d x 1 1/2" <br />NAILS <br />UPLIFT = 1015# <br />Filler blocking + 1/8" min. ) Small gap ?min. <br />max. -_ - <br />1/8" gap Web Stiffener Fastener Schedule __ <br />max. 4 <br />TYPICAL SIMPSON LUS/HUS/HUC TYPICAL SIMPSON H10A <br />Joist Bearing Location _ <br />f r _ _Series 9 Depth End Intermediate <br />- 9 - _2-8d --i <br />epth _ 2=sd INSTALLATION INSTALLATION <br />t i 1ti / R' <br />Clinch nails / BCI 5000s0 1114/8' I. 2 8d 5-8d <br />R 9-1/2 2-8d 2-8d _ <br />when \ BCI 6000s01-1-7/8"} 2 8_-_ 3-8d 4" MIN. EMBEDMENT <br />possible /✓/ BCI 6500s® 14" -_2-8� 5-8d SEE SCHEDULE FOR <br />1) Support back of web during nailing to prevent damage to - 16 2-8d _ _ 6-8d °o SIZE AND QUANTITY <br />11 7/8 1 2 8d 3-8d <br />-'4 1 - BCI 60s 1,V i 2 8d _ 5-8d o OF FASTENERS <br />web -flange connection. / O - <br />2) Block solid between joists for full length of span. Tight fit - 16 2-8d 6-8d__ o <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 3-16d 3-16d <br />2x4/PI od/OSB web stiffener 2" min. o <br />4) Place joists together and nail from each side with 2 rows of 10d nails 0 4" max BCI 90s 1114" 5-16d 5-16d /- o <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when Indicated or - I 16 6-16d 6-16d <br />OF THE JOIST ASA REQUIRED LEAVING y" GAP TOP sides b 6". - Hangers with side nailing. <br />�° y -Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouth cuts• N.T.S. <br />--- - Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />1/16 <br />details in <br />One 10d box <br />areas=20 of high <br />or-20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) —/ <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES -� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br /><�> Load bearing walls <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 pff max. along bearing wall <br />Required on interior walls: - for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or J <br />ream below Load bearing wall must stack over <br />blocking and wall or beam below.* - - - <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />�= <br />Provide adequate bearing Use 10dx3" nails at 6"o.c. for all joist <br />for each lapped joist. <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />10d nails SECTION @INT. BRG. WALL— <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />tit UU I ANYwFitKt IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN 1Y" <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1%" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE, <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />77. <br />i <br />00 <br />FINISH GRADE <br />Backer block (12" wide min.) III -III -I I I -I I- <br />< Nail with 10-10d nails. =1 11=1 I -�� <br />� �� tall tight t top flange. SLEEVE THRU STEM <br />_4 SEE PLAN FOR °. • .. ; . • <br />Joist hanger / r a ° <br />FOUNDATION INFO <br />STEM FOUNDATION <br />GRADE <br />Filler block. REINF. SEE PLAN <br />Nail with <br />10-10d nails. <br />Backer block required where top a d <br />mount hanger load exceeds 250 lbs.— <br />Install tight to top flange. °Illl <br />1/4"-2" gap - <br />f ✓� <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1l4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6XJoist <br />depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />i-vu unmoC 4 rvt✓ <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />]- a <br />a <br />I-III—1 151 Nd. <br />111 �lllllil1 <br />—12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />1=111=11 I, , <br />d M ME111- <br />•.. i�llll;li <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4' 0" <br />CENTERED @PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />/ r- PLUMBING LINE <br />z •a � <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />a <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />d,. <br />d f do G <br />n d <br />a d j <br />a <br />Q <br />SEE FND. PLN. <br />SIZE & REINF. <br />C <br />C <br />C' <br />C 4 <br />_o <br />-o <br />=o <br />cv <br />Lcc <br />yi <br />fl m X <br />y f9 O <br />y O N t <br />� N Y <br />67 � <br />daY� <br />E = c <br />CU <br />� 3 � <br />to -W <br />r <br />y G <br />E <br />cco <br />® W <br />O <br />r,C7 <br />f <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />WV EQ <br />V N O C O 8 <br />Y W N <br />. <br />M M v # LL <br />Q F-2 LL W <br />U <br />cc LL a <br />d <br />Y <br />Z � C � <br />5 g f 0 <br />1% CO <br />W n rn m <br />60 W <br />Z In co z° a <br />LL <br />a N O U cd U <br />U U) <br />W <br />❑❑ <br />M .2 <br />z N M <br />z <br />n J <br />a <br />z <br />U o <br />W <br />o p <br />U <br />� w S <br />Ln c w <br />c <br />ULU <br />s <br />I <br />U o' as <br />• <br />Q 0 <br />N ODD <br />o <br />co <br />w <br />co <br />a <br />Z <br />Z <br />< <br />� <br />C6 E <br />�o <br />sF <br />wzO� <br />>� <br />a <br />Q O <br />Eu <br />z® <br />om <br />CL <br />00 <br />aZ <br />O <br />N � <br />azz <br />e <br />W�w <br />C <br />Q <br />NU <br />mo <br />~Oz <br />= <br />z <br />J <br />O <br />Q W <br />�I <br />rb <br />gp <br />ZO <br />Q U <br />a <br />W <br />Q <br />LL <br />Nw <br />co <br />a r <br />v <br />zIa <br />° 3 <br />c O <br />0 <br />_rn <br />CV <br />-4Co <br />O <br />ch <br />M <br />N <br />N <br />' <br />. <br />0o <br />in m <br />T <br />N <br />O <br />LO <br />+-� <br />N <br />LO <br />O <br />M <br />c� <br />Q O N <br />U--) <br />0 <br />E <br />E <br />w CO <br />CV <br />o <br />Z <br />Z <br />E T N <br />c <br />o- <br />E v w <br />U � Q p <br />c <br />JOB <br />NO: 22-06559-06554 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />