Laserfiche WebLink
II' LI a_ 1' 'I I _ <br />*DIAGONAL SPACED <br />�U <br />AT 15'-0" O.C. MAX <br />SEE ROOF <br />PROVIDE 2X4 MIN. BLOCKING AT <br />PLAN <br />SHEATHING <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />BLOCKING <br />END TO TRUSS TOP CHORD <br />TYP. <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />TRUSS <br />A <br />SECT. A -A <br />A <br />G.T. <br />CONTINUOUS LATERAL <br />ADD 2X4 ALONGSIDE <br />BRACING- NAIL OVER <br />TOP CHORD WHEN REQ'D <br />X-BRACE AS SHOWN- <br />TO PREVENT PLYWOOD <br />INSTALL BLKG. AT TRUSS <br />X-BRACING - 2x4 SPF OR <br />SPAN FROM EXCEEDING <br />A CK <br />WEBS FOR NAILING <br />SYP w/2-16d @EACH TRUSS <br />MAX 24" SPAN (EITHER <br />USSES <br />HIP <br />NNG.T <br />WEB <br />SIDE OR BOTH IF REQ'D) <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: 1/2" = V-0" <br />(2) 12D NAILS <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL r2 <br />SCALE: 1 /2"=1'-0" <br />TRUSS NOTES: <br />TYP. HAND FRAMING ABOVE TRUSS <br />FRAMED RIDGE 2X4 STUDS & PLATES AT 2.O.O.C. <br />1. <br />WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014CON <br />MAY B <br />M <br />MAYBE NAILED EACH DIRECTION TYP. U.N.O. <br />( TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER <br />w/MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE <br />IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS 2x8 BLKING. NAILED @EACH <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />WH <br />WH <br />SIDE w/ (3) 12d NAILS WHEN <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />REQUIRED w/ (2)NAILS <br />SIMPSON HTS20 <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />W/ (14) - 10d X 1 1/2" EACH <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />�C <br />2. <br />ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTURER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. <br />ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />Cg <br />4. <br />ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />TB <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. <br />pg g <br />5. <br />PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />PRE-ENG. TRUSS <br />2X4 BLOCKING <br />2X4 DIAGONAL AT 8'-0" O.C. BETWEEN EA. TRUSS <br />CONT. ROOF SHEATHING AT TRUSS TOP <br />MAX &EACH END ALTERNATE <br />DIRECTION TYP. A <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" O.C. <br />W/ (4) 10d TOP & <br />BOTTOM OR SIMPSON H2.5A <br />W/ (10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR SIMPSON H2.5A @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />DIAGONAL 2x8 #2 SPF RIDGE BEAM <br />AT 8'-0" WOOD <br />MAX TRUSS * * 2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. AT--/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL aC� INTERIOR BEARING r3 <br />WOOD TRUSS SCALE: 1/2" = 1'-0" <br />J A PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />TYP WOOD TRUSS BLOCKING DETAIL STANDARD HEEL HEIGHT <br />SCALE: 1 /2"=V-0" <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN277 <br />(2) SIMPSON SDWC15600 SCREWS @ <br />EACH TRUSS TO LEDGER — <br />ROVIDE 25" LAP <br />SPLICE @ F.C. REBAR <br />1/2" GYP. WB <br />OR 3/8" PLYWOOD/ TYPE 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/8d <br />TOP -CHORD BEARING <br />COMMON @ 6" O/C TO ONE SIDE OF THE <br />FLOOR TRUSSES @ <br />FLOOR TRUSS FOR AN <br />24" O.C. <br />AREA 5 1000 SQ. FT. OF <br />FLOOR AREA & SEALED <br />PENETRATION AREA W/ <br />FOAM. DRAFTSTOPPING �j i <br />SHALL DIVIDE THE \ <br />CONCEALED SPACE INTO / <br />APPROX. EQUAL AREAS. <br />2) 2x8 SYP #2 P.T. <br />LEDGER ATTACHED TO <br />MASONRY w/ (2) ROWS <br />1/2" SIMPSON TITEN HD, <br />MIN. 5" EMBEDMENT PER <br />54/D1 SPACING. <br />DOUBLE KNOCK -OUT <br />BLOCK w/ (1) #5 CONT. <br />IN EACH COURSE. <br />FLOOR CONNECTION EXTERIOR WALL <br />SCALE: 3/4" = V-0" <br />2'-0" MIN. <br />LAP SPLICE <br />1'-0" 6" 6" 1'-0" 6" 6" <br />TYP. <br />O O 1 O O <br />I SPLICE <br />O I O O <br />2-4- SPLICE BEYOND <br />PART. ELEV. VIEW <br />1 A" n r, <br />DBL. KO. BLOCK MIN. <br />MIN. TYP. <br />1:1 <br />E� <br />F1 <br />24" MIN. <br />(2)2x8 P.T. <br />ATTACHED <br />C <br />(2) 2x8 SYP #2 P.T. CONT. <br />LEDGER w/ (2) ROWS OF 1/2" <br />TITEN HD STAGGERED @ 24" <br />O.C. w/ 5" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE & <br />EACH END. <br />LEDGER <br />LAP SPLICE TOGETHER w/ <br />PART. PLAN VIEW (2) ROWS OF 10d @ 6" O.C. <br />LEDGER SPLICE DETAIL 54 <br />SCALE: 5/4" = V-0" <br />- PROVIDE 30" LAP SPLICE <br />@ F.C. REBAR. <br />(2) ROWS OF 10d NAILS @ 4" O.C. <br />FLOOR TRUSSES <br />—@ 24" O.C. <br />1!� <br />DOUBLE KNOCK -OUT <br />BLOCK W/ (1) #5 ALTERNATE: <br />CONT. IN EACH (2)2x8 SYP #2 P.T. <br />COURSE LEDGER ATTACHED TO MASONRY W/ <br />(2)-1/2" DIA. TITEN HD MIN. 5" <br />EMBEDMENT PER 54/D1 SPACING <br />SIMPSON HGAM10 @ <br />4'-0" O.C. T & B <br />FLOOR ATTACHMENT 50 <br />SCALE: 3/4" = V-0" <br />WOOD TRUSS <br />DETAIL - ADJACENT TO TRUSSES <br />OPTIONAL 6" WIDE BOARD <br />BATTEN STRIPS TO <br />ELIMINATE 3/4" AIR SPACE. <br />SEE MANUFACT. SPECS. <br />FOR INSTALLATION. <br />PRE-ENGINEERED ROOF --\ <br />TRUSSES AT 24" O.C. MAX <br />(2) LAYERS 1"X24" PROPRIETARY TYPE <br />"X" GYP. PANELS INSERTED BETWEEN <br />2" FLOOR & CLG. RUNNERS W/ 2" <br />STEEL H STUDS BETWEEN ADJACENT <br />PAIRS OF GYP. PANELS. <br />2" FLOOR RUNNER <br />W/ 3/16" DIA. x 1 3/4" <br />TITEN2 @ 16" O.C. <br />FIRE CAULK <br />RUNNER TO BLOCK <br />WALL EACH SIDE <br />NOTES: <br />1. SEPARATION WALL IN THE <br />ROOF SYSTEM PROVIDES <br />2-HRS. PROTECTION PER <br />GA FILE ASW 1002. <br />6" WIDE 1/2" DENSARMOR PLUS FIREGUARD-C OR <br />TOUGHROCK FIREGUARD-C GYPSUM BOARD <br />MASONRY <br />SEE PLAN <br />GA FILE ASW 0810 SCALE: 3/4"=V-0" <br />M\_1OA-MC:KIA'LS <br />2X6 P.T. CONT. <br />-EDGER T&B W/ (2) <br />1/4" X 3" TITEN2 @ 24" <br />D.C. T&B <br />TRUSS <br />(6) .162" x 3 1/2" NAILS <br />TRUSS TO LEDGER & <br />(4) .148" x 1 1/2" <br />LEDGER DETAIL <br />SCALE: 3/4" = V-0" <br />NO MINIMUM AIR SPACE <br />W/ BATTEN STRIPS <br />1" DENSGLASS ULTRA <br />SHAFT LINER <br />2X4 BLOCKING @ 48" O.C. MAX. W/ 0 LB FELT (SHINGLES) <br />(2) 16d TOE NAILS @ EACH END FIRE RESISTANT OSB 7/16" <br />2" CLG. RUNNER FIRE CAULK SHEATHING 4' ON EA. SIDE <br />RUNNER TO SHEATHING OF WALL NOT STAGGERED CEILING BOARD <br />ABOVE AT EACH SIDE-? OVER PARTY WALL <br />STD 902 HOOK <br />2. MASONRY WALL PROVIDES (1) #5 VERT. IN FILL CELLS <br />2-HRS PROTECTION PER (SEE FILL CELL PLAN FOR <br />UL-U905 (see sht 9) LOCATIONS) <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 <br />(2) SIMPSON SDWC15600 SCREWS @ EACH <br />TRUSS TO LEDGER <br />SEE 53/D1 <br />3/4" PLYWOOD DECKING GLUED AND <br />NAILED W/ 8d COMMON AT 6" O.C. <br />EDGES AND 12" O.C. FIELD <br />1/2" GYP. WB. OR 3/8" PLYWOOD/TYP 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/ , <br />8d COMMON AT 6" O.C. TO ONE SIDE OF TOP CHV <br />1 <br />FLOOR TRUSS FOR AN AREA < 1000 S.F. 00 I <br />AND SEALED PENETRATION AREAS W/ <br />FOAM. DRAFTSTOPPING SHALL DIVIDE <br />THE CONCEALED SPACE INTO APPROX. <br />EQUALAREAS <br />(1) LAYER 1/2" HIGH STRENGTH OR 5/8" GYP.—// <br />(OR 5/8" GYP. TYPE "X" @ GARAGE W/ A <br />HABITABLE ROOM ABOVE) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" <br />O.C. CEILING, 8" O.C. WALLS & 4" O.C. <br />EDGES <br />(1) #5 VERT. IN FILL CELLS (SEE <br />FOUNDATION PLAN FOR LOCATIONS) <br />MASONRY WALL <br />SEE FLOOR <br />PLAN FOR MORE <br />INFO. <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />MIN. 2x4 #2 SPF P.T. <br />CONT. W/ (2) 21r'x3" <br />TITEN2 SCREWS @ <br />16" O.C. <br />TRUSS OR <br />/ ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL 52 <br />SCALE: 3/4" = 1'-0" <br />PROVIDE 2x BLOCKING W/ (2) 12d NAILS EA. END BETWEEN <br />TRUSSES 4'-0" FROM SEPARATION WALL. SOLID BLOCKING <br />12 BETWEEN TRUSSES TO BOTTOM SIDE OF PLYWOOD. BLOCK <br />SEE MUST BE "PITCH CUT" (SEE ELEVATIONS) TO PROVIDE AS <br />a ELEV. MUCH CONTACT AS POSSIBLE TO UNDER SIDE OF ROOF <br />DECK. ALL JOINTS AROUND BLOCKING MUST BE CAULKED <br />WITH APPROVED FIRE CAULKING. <br />2x4 LEDGER @ 48" O.C. SEE ROOF PLAN <br />MAX VERTICALLY NAILED FOR STRAP INFO. <br />TO TRUSS WEBS W/ (2) 8d BASE BOARD PER SPECS. <br />(TYP.) <br />EXTEND BURN CLIPS AS PER 2 x P.T. BLOCKING BY FRAMER <br />FIRE WALL MFG. FOR PLYWOOD EDGE NAILING <br />R30 INSUL. MIN. SPECIFICATIONS NAILED INTO W/ (2) 1/4"x3" TITEN2 <br />2X4 LEDGER ONLY AT EACH <br />SIDE OF STEEL "H" STUD. <br />(2) SIMPSON SDWC15600 <br />(1) LAYER 1/2" HIGH STRENGTH SCREWS @EACH TRUSS TO <br />OR 5/8" GYP. WB. W/ 1 3/8" LEDGER <br />DRYWALL NAILS OR DRYWALL <br />SCREWS 7" O.C. EDGES. <br />SIMPSON RBC @ 36" O.C. W/(6) 10d X 1 1/2" NAILS 3/4" FLOOR <br />INTO TRUSS BOTTOM CHORD/SCAB & (3) 1/4" X 2-3/4" SHEATHING <br />TITEN SCREWS INTO MASONRY. NOTE: RBC CLIPS <br />TO BE INSTALLED PRIOR TO FURRING STRIPS <br />INSTALLATION (TYP. ON BOTH FACES OF WALL) <br />1x P.T. NAILER INSTALLED <br />AFTER INSTALLING RBC'S 1/2" GYP. WB OR 3/8" <br />8"x8"x16" CONC. KNOCKOUT PLYWOOD/ <br />BLK. W/ 1 #5 ROD CONT. TYPE 2-M-W OSB <br />FILLED W/ GROUT (DRAFTSTOPPING) j <br />4"x4" INSPECTION PORT AT 0 BE NAILED W/8d <br />EACH FILLED CELL (TYP.) COMMON @ 6" O/C TO <br />i1x P.T. BASE NAILER ONE SIDE OF THE <br />—STD. 902 HOOK FLOOR TRUSS FOR AN <br />(SEE DETAIL) AREA 5 1000 SQ. FT. OF <br />NAIL FLOOR TRUSS TO LEDGER W/ FLOOR AREA & SEALED <br />(4) 10d TOENAILS (TYP.) EA. SIDE PENETRATION AREA W/ <br />77=FOAM. DRAFTSTOPPING <br />(2) SIMPSON SDWC15600 SCREWS SHALL DIVIDE THE <br />@ CONCEALED SPACE INTO <br />\� EACH TRUSS TO LEDGER APPROX EQUAL AREAS <br />DOUBLE KNOCKOUT BLOCK W/ (1) #5 ROD <br />CONT. IN EA. COURSE FILLED W/ GROUT <br />1" P.T. NAILER <br />R-3 MIN. INSUL. PER. FBC. <br />1/2" GYP. WB. <br />TYP. "S" MORTAR (TYP.) <br />8" CONC. BLOCK (TYP.) PER UL905 ? =I <br />�a <br />1x P.T. BASE NAILER N a <br />6x6 W1.4xW1.4 WWF. J 4"x4" INSPECTION PORT. AT <br />EACH FILLED CELL (TYP.) <br />0 <br />(4) #5 CONT. STD. 902 HOOK <br />ON 3" CHAIR 8" 2'-0" 8" (SEE DETAIL) <br />2-STORY PARTY WALL SECTION (PWO <br />SCALE: 3/4"= V-0" <br />PRE-ENGINEERE <br />FLOOR TRUSS' AT <br />24" O.C. <br />GYP. BOARD CLG. <br />SEE 53/D1 FOR <br />LEDGER CONNECTIONS <br />1/2" GYP. BD. <br />(2)-1 X 4 P.T. BASE —� <br />NAILER <br />BASE BOARD <br />PER SPECS. —� <br />CONC. SLAB <br />SEE FOUND. PLAN-- <br />6 MIL VISQUEEN —� <br />SEE PLAN <br />TOP OF PLATE <br />TOP COURSE W/ <br />LINTEL SEE <br />PLAN <br />rk SEE PLAN <br />P OF WINDOW - <br />WINDOW PER PLAN <br />8" C.M.U. WALL <br />1 U-8" <br />DOUBLE KNOCK -OUT <br />W/ (1) #5 CONT. IN. <br />EACH COURSE <br />REINFORCING W/ MATCHING <br />#5 DOWELS IN SOLID <br />GROUTED CELL W/ MIN. 25" <br />LAP SPLICE MIN. <br />8" C.M.U. WALL <br />TOP OF SLAB 0'-0" <br />F.F. <br />80 VARIES WITH <br />o SITE GRADES <br />TREATED SOIL SEE PLAN <br />CV <br />r <br />0 <br />3 #5 CONT. 20" <br />TYP. 2 STORY WALL SECTION 55 <br />SCALE: 3/4" = V-0" <br />REV. 08.20.21 <br />N <br />N <br />C1 <br />N <br />� W <br />= �tmc <br />N_ co O <br />N C C= Cc <br />do�a <br />a <br />► d A T <br />e <br />m o <br />f1.• u <br />.\� iirliolalrf <br />�: +: • r, 0 W r <br />61 <br />OFES �O <br />d <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />4 <br />-or <br />O M 8 <br />CM 50) <br />w �Q <br />C <br />m <br />�� <br />rn <br />a <br />NO # u_ <br />U. <br />caU_IL W <br />a <br />0 <br />z <br />`° _ °' a <br />L;°9 <br />w �•@Nt0 0 O <br />cp Q. m <br />= <br />LLW05 <br />� NZQJ <br />N OU v <br />z <br />W <br />❑ ❑ <br />CD M � <br />O <br />z <br />a) <br />z o � <br />Q <br />0- N <br />M <br />c� <br />� <br />(D <br />o <br />LL <br />- <br />4., <br />(awC <br />a <br />V <br />O <br />V) <br />w o <br />t,•d <br />w <br />E <br />I� ... <br />... <br />� � <br />—G <br />U <br />c W Y <br />Q <br />N W <br />IIY <br />o <br />Cl) <br />w <br />Z <br />a� <br />U_ <br />E E <br />1a <br />oz <br />>� <br />Z® <br />4 <br />QE <br />CU @ <br />a <br />Rg' <br />�¢�z <br />_° <br />Z <br />o <br />N <br />�= <br />o <br />Q <br />wZ <br />L <br />. p <br />�N � <br />p <br />,rs <br />m E <br />O <br />rr <br />OZ <br />�a <br />z <br />MJ <br />zZ <br />y <br />Q > <br />og <br />w <br />o <br />a <br />nw <br />W <br />o <br />Jz <br />w <br />>° <br />a, <br />z< <br />°� <br />2O <br />0 <br />> CO <br />o� <br />CN <br />CV <br />CO <br />M <br />N <br />LO <br />CV <br />T <br />Cr <br />N <br />60 <br />U) m <br />N <br />LO <br />C <br />o <br />O <br />C37 <br />Qh <br />N <br />Ci <br />O <br />CN <br />T <br />E <br />E <br />(fl <br />o <br />z <br />m <br />Z <br />� <br />N <br />FL <br />E <br />c� <br />¢ o <br />uj <br />JOB <br />NO : 22-06559-06554 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />D 1 <br />