My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36812 Yesler Dr
Zephyrhills
>
Building Department
>
Building Plans
>
36812 Yesler Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 10:04:03 AM
Creation date
2/19/2025 8:15:59 AM
Metadata
Fields
Template:
Building Plans
Street #
36812
Location
Yesler Dr
Contractor
K Hovnanian, LLC
Building Plans - Permit #
3291
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEE <br />SOFFIT AT RAKE (BEYOND) <br />REFER TO PLANS <br />FINISH PER PLAN <br />7/8 STUCCO OVER LATH <br />W/ 60 MIN. GRADE D PAPER BACKED <br />LATH OVER BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />BENT METAL FLASHING <br />REFER TO "L" FLASHING DETAIL <br />2X LEDGER BOARD <br />7/8 STUCCO OVER LATH <br />W/ 60 MIN. GRADE D PAPER <br />BACKED LATH OVER <br />BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />HURRICANE STRAP EACH <br />END OF TRUSS - REFER TO <br />STRUCTURAL. <br />MID -WALL WEEP SCREED/ <br />EXPANSION JOINT <br />(REFER TO ELEV.) � / � ; Y(REFER TO ELEV.) <br />INSULATION AS Lj 2X ALUM WRAPPED FASCIA INSULATION AS _ <br />BD. w/ALUM DRIP EDGE <br />PER SPECS. �� PER SPECS. 2X ALUM WRAPPED FASCIA <br />1/2" (MIN.) CLG. BD. ' SOFFIT INSTALLED PER 1/2" (MIN.) CLG. BD. BD. WALUM DRIP EDGE <br />MANUF. SPECS PRE-ENGINEERED SOFFIT AS PER SPECS. <br />PRE-ENGINEERED 2X PT BLOCKING <br />GABLE END ROOF HURRICANE STRAP - REFER TO GABLE END ROOF <br />TRUSS -REFER TO MASONRY LINTEL, SEE <br />TRUSS - REFER TOSTRUCTURALS <br />STRUCTURALS I-, LSTRUCTURALS STRUCTURALS <br />—9 <br />TYP. PENT ROOF DETAIL TYP. GABLE END DETAIL <br />SCALE: 1/2" = 1'-0" 2-STORY - FRAMED WALL SCALE: 1/2" = 1'-0" 1-STORY - MASONRY WALL <br />ROOF SHINGLES OVER ROOF SHINGLES OVER ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR TWO LAYERS OF ASTM D226 TYPE II OR TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING SYNTHETIC UNDERLAYMENT COMPLYING SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER WITH ASTM D226 TYPE II INSTALLED PER WITH ASTM D226 TYPE II INSTALLED PER <br />R905.1.1.1 (SEE SHEET CS2) R905.1.1.1 (SEE SHEET CS2) R905.1.1.1 (SEE SHEET CS2) <br />ROOF SHINGLES OVER OR OR OR <br />TWO LAYERS OF ASTM D226 TYPE II OR CONCRETE TILE W/ SELF ADHERED CONCRETE TILE W/ SELF ADHERED CONCRETE TILE W/ SELF ADHERED <br />SYNTHETIC UNDERLAYMENT COMPLYING MEMBRANE UNDERLAYMENT MEMBRANE UNDERLAYMENT MEMBRANE UNDERLAYMENT <br />WITH ASTM D226 TYPE II INSTALLED PER 12 60 MIL. OR EQUAL 12 60 MIL. OR EQUAL 12 60 MIL. OR EQUAL <br />R905.1.1.1 (SEE SHEET CS2) I SEE ROOF SEE ROOF SEE ROOF <br />OR PLAN PRE-ENGINEERED ROOF PLAN PRE-ENGINEERED ROOF , PLAN PRE-ENGINEERED ROOF <br />7 TRUSSES AT TYP. 24" O.C. TRUSSES H TYP. 24" O.C. <br />CONCRETE TILE W/ SELF ADHERED TRUSSES AT TYP. 24" O.C. <br />�....4 � ` 7 BOTTOM CHORD VARIES. REFER <br />MEMBRANE UNDERLAYMENT , BOTTOM CHORD VARIES. REFER \� BOTTOM CHORD VARIES. REFER <br />60 MIL. OR EQUAL TO TRUSS MFGR. DRAWINGS. TO TRUSS MFGR. DRAWINGS. TO TRUSS MFGR. DRAWINGS. <br />12 HURRICANE STRAP EACH END , HURRICANE STRAP EACH END HURRICANE STRAP EACH END <br />SEE ROOF RE -ENGINEERED ROOF - - - A� , OF TRUSS - REFER TO ��� OF TRUSS - REFER TO OF TRUSS - REFER TO <br />PLAN TRUSSES AT TYP. 24 O.C. _ _ _Z STRUCTURAL. STRUCTURAL. _ _ . ` - 7 STRUCTURAL. <br />BOTTOM CHORD VARIES. REFER --., TOP OF C.M.U. TOP OF C.M.U. _ --- - _ - _ > TOP OF C.M.U. <br />TO TRUSS MFGR. DRAWINGS. - (REFER TO ELEV.) -- - (REFER TO ELEV.) `` ..� (REFER TO ELEV.) <br />HURRICANE STRAP EACH END INSULATION PER I 2x6 ALUM WRAPPED FASCIA 2x6 ALUM WRAPPED FASCIA 2x6 ALUM WRAPPED FASCIA <br />e OF TRUSS - REFER TO COMMUNITY SPEC. <br />-_-- EE BD. w/ALUM DRIP EDGE - - -- ---_ 1/2" EXTERIOR SOFFIT EE BD. w/ALUM DRIP EDGE <br />STRUCTURAL. SEE ENERGY CALCS. - EE BD. w/ALUM DRIP EDGE <br />" - _ BD. W/ KNOCKDOWNOL E V. <br />Z ` 1/2" (MIN.) - - E V. PLASTER FINISH - <br />TOP OF WALL 1/2" (MIN.) CLG. BD. SOFFIT INSTALLED PER CLG. BD. SOFFIT INSTALLED PER SOFFIT INSTALLED PER <br />- - (REFER TO ELEV.) SEE STRUCTURAL <br />MANUF. SPECS ' TYPE'X' GYP. BD. MANUF. SPECS MANUF. SPECS <br />INSULATION PER r, 1x PT DRAPE BLKG (�' PLANS <br />COMMUNITY SPEC. ABOVE WINDOWS 1/2" TO BE PROVIDED 2X PT BLOCKING <br />SEE ENERGY CALCS. S E 2X ALUM WRAPPED FASCIA G.W.B. 2X PT BLOCKING WHEN LIVING SPACE 2X PT BLOCKING <br />BD. w/ALUM DRIP EDGE SEE STRUCTURAL IS ABOVE GARAGE) SEE STRUCTURAL <br />EL <br />1/2 (MIN.) CLG. BD. SOFFIT INSTALLED PER WINDOW PER PLAN PLAN PLAN <br />MANUF. SPECS <br />le 2X PT BLOCKING <br />SOLID SURFACE <br />WINDOW PER PLAN HEADER PER STRUCTURALS CAULKED @ WINDOW 8" CMU BLOCK <br />W/ CEMENTITIOUS FINISH <br />1/2" GYP. BD. OVER RADIANT <br />PROVIDE BATT INSUL. —EXTERIOR FRAMED WALL BARRIER INSULATION (R-4.1) PRECAST WIN. SILL <br />PER ENERGY CALCS. THICKNESS PER PLAN ATTACHED TO 1x2 PT. <br />FURRING @ 24" O.C. SLOPE GRADE AWAY EXPANSION JOINT SLOPE GRADE AWAY <br />PRE-ENGINEERED BASE BOARD FROM HOUSE GARAGE SLAB, 4" SPECS <br />PER COMMUNITY <br />FROM HOUSE <br />FLOOR TRUSSES 7/8 STUCCO OVER LATH SEE STRUCTURAL <br />w/ 3/4" SUBFLOOR W/ 60 MIN. GRADE D PAPER BACKED 0'-0" PLANS 0'-01, 0'-0" <br />SCREWED AND GLUEA LATH OVER BARRICADE PLUS WRB FIN. FL. SLOPE SLOPE SLOPEREFER TO STRUCTU(OR APPROVED EQUAL)- FIN. FL. FIN. FL. <br />DRAWINGS FOR SIZE <br />ORIENTATION WALL SHEATHING PER <br />STRUCTURAL PLANS . FOUNDATION <br />� FOUNDATION �r FOUNDATION <br />OL TOP OF FLOOR <br />PER STRUCTURAL DRAWINGS ci PER STRUCTURAL DRAWINGS PER STRUCTURAL DRAWINGS <br />(REFER TO ELEV.) <br />SCREE /EXPAN TYP. 1-STORY WALL P WINDOW WALL SECTION C GARAGE DOOR- TYP. CMU COLUMN C@ LANAI/PORCH <br />SCREED/EXPANSION JOINT <br />rc' TOP OF CMU SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" <br />_ <br />(REFER TO ELEV.) <br />1/2" (MIN.) CLG. BD. <br />DRAFTSTOPPING AS <br />PER R302.12 WHEN <br />CONCEALED SPACE <br />EXCEEDS 1,000SF <br />1 x6 PT DRAPE BLKG <br />ABOVE WINDOWS <br />WINDOW PER PLAN <br />SOLID SURFACE <br />CAULKED @ WINDOW <br />1/2" GYP. BD. OVER RADIANT <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO 1x2 PT. <br />FURRING @ 24" O.C. <br />BASE BOARD <br />OL TOP OF WINDOW <br />(REFER TO ELEV.) <br />SEE STRUCTURAL <br />DRAWINGS <br />PRECAST WIN. SILL <br />$" CMU BLOCK <br />w/ CEMENTITIOUS <br />FINISH <br />-SLOPE GRADE AWAY <br />FROM HOUSE <br />" <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 2-STORY WALL SECTION - <br />SCALE: 1/2" =1'-0" <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4 <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />"' GYPSUM <br />BOARD <br />ELECTRIC METER---_______, <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD <br />STUCCO <br />FINISH <br />EXTERIOR <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />GYPSUM - <br />GYPSUM <br />BOARD <br />BOARD Z <br />g <br />�3 1/2" <br />j" GYPSUM <br />Er <br />w <br />GARAGE n. <br />BOARD <br />NICHE FOI <br />ELECTRIC <br />PANEL & <br />WIRING <br />cV <br />ELECTRICAL M <br />PANEL ELECTRIC <br />PANEL <br />N <br />co c° EXTERIOP <br />CMU BLO( <br />WALL <br />CONCRETE CONCRET <br />CURB REFER CURB REF <br />TO PLANS TO PLANS <br />DIMENSIONS PRIOR TO x�?� 4?��t},}s�`svr a SLAB ON <br />CONSTRUCTION. GRADE _ GRADE AT <br />---- GARAGE <br />%L <br />NL <br />ATTIC <br />FLOOR <br />REFER <br />OR SECOND <br />LIVING SPACE <br />TO PLANS <br />T.O. M <br />z <br />g <br />a <br />� <br />w <br />a <br />4. <br />I i <br />i I <br />I <br />I <br />� I <br />I i <br />I <br />� I <br />L------ I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />cV <br />io <br />N <br />N <br />1 6 <br />ER <br />FLOOD <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" =1'-0" <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />!� ti <br />7 824 <br />3 % S TE OFAl <br />' <br />r <br />,Nf�: <br />Iz <br />W <br />Wz0= <br />O } P <br />WOC¢O <br />0 F- <br />Q ? W <br />W <br />W W <br />J cc cr. <br />zZ�W , <br />U) <br />W <br />_ — <br />a a <br />U WO 0 <br />�I=—Qz25 <br />rczn <br />r- <br />�� Q o <br />O <br />�¢ <br />Q <br />0 <br />I <br />z <br />U <br />0 <br />0 <br />M..1 <br />U U <br />w <br />LL <br />a cn <br />i� <br />0 <br />w <br />0 <br />z <br />r�r <br />O_ <br />R <br />tz <br />W <br />0 <br />N <br />oa <br />� <br />[a <br />1z <br />Z. <br />a <br />a <br />a! <br />a <br />OV 0 5 2021 <br />COMMUNITY: <br />UI K ALUA SPRINGS <br />PLAN # 6103 <br />RELEASED: 10/2S/21 <br />SHEET <br />Av.2 <br />11; <br />
The URL can be used to link to this page
Your browser does not support the video tag.