2" PVC CONDUIT <br />2-2/0 COPPER <br />1-1/0 COPPER <br />O OR <br />2-4/0 ALUMINUM 150 AMP 42 <br />METER 1-3/0 ALUMINUM CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. BREAKER <br />PVC 1/2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />iI <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />a <br />a <br />ELECTRICAL <br />METER (V.I.F.) <br />FIRST FLOOR ELECTRICAL PLAN <br />ELECTRICAL KEY <br />i DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />USB COMBO OUTLET <br />WALL SWITCH <br />s THREE-WAY SWITCH <br />4 FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />VAPOR PROOF LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />f� EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />oM COMBINATION SMOKE / CO2 DETECTOR <br />so SMOKE DETECTOR <br />f4 TELEPHONE (OPTIONAL) <br />R TELEVISION (OPTIONAL) <br />o7 ELECTRIC METER <br />._. ELECTRIC PANEL <br />DISCONNECT SWITCH <br />aD JUNCTION BOX <br />/I'-- STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2017 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED; INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ........ A 4" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O17 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2017 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH _ <br />NEC 110.26. <br />:O <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN'-,, <br />r <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE <br />O= <br />O >-LLJ I— <br />>oWCaO <br />WoI­- <br />< <br />F_ <br />_F;-J <br />��crcr <br />ozOOW <br />ItnQ2-1 <br />W 0-2Era <br />Z)=zLLu) <br />H Q zcz O <br />0 <br />r <br />0 N <br />O � <br />a <br />a <br />0 <br />o (L <br />Lo <br />0 <br />J <br />LL. U <br />0 <br />= <br />i <br />w <br />w <br />U <br />mmom <br />a <br />� w <br />U) <br />wi <br />w <br />z <br />0 <br />C <br />:3 <br />ol <br />O_ <br />U) <br />W <br />U� <br />Z <br />O� <br />,, <br />d <br />r <br />�QQ <br />o <br />G �E fv' <br />- i <br />r� <br />77824 e <br />TE p F <br />SCALE: 1 /4"=1'-0" <br />