q <br />a <br />it <br />f <br />DESIGN CRITERIA <br />BASIS OF DESIGN: <br />ALL CONSTRUCTION IS DESIGNED AS FOLLOWS: <br />FLORIDA BUILDING CODE 6TH EDITION 2017 <br />DEAD LOADS <br />ROOF 15 PSF <br />LIVE LOADS <br />FLOOR 40 PSF <br />ROOF 20 PSF <br />WIND LOADS <br />ASCE 7-10, 146 MPH WIND (ULTIMATE), 113 MPH (NOMINAL) <br />BUILDINGS OF ALL HEIGHTS ANALYTICAL METHOD <br />RISK CATEGORY II <br />EXPOSURE CATEGORY "B" <br />ROOF SLOPE: 0.25:12 <br />INTERNAL PRESSURE COEFFICIENTS: <br />GCpi = +/- .18, ENCLOSED STRUCTURE <br />BASIC WIND PRESSURE: q= 32.5 P.S.F. (C&C) <br />EDGE DISTANCE: a= 10 FT <br />STRENGTH OF MATERIALS: <br />REINFORCING STEEL ----- ------------ ------------ ------- ------ fy = 60,000 psi <br />CONCRETE SLAB, BEAMS AND FOOTINGS ----------------- fo = 3,000 psi <br />REINFORCED MASONRY ------- --- ---------- ------------- - f� = 1,500 psi <br />MASONRY GROUT -------- ----- ---------------------------------- -- f� = 3,000 psi <br />SOIL BEARING (ASSUMED, TO BE VERIFIED) ----- ------------- Sb = 2,000 psf <br />STRUCTURAL STEEL SHAPES ------------------------------- fy = 36,000 psi <br />STRUCTURAL STEEL SHAPES (HSS)----- -------------- - --- --- fy = 46,000 psi <br />STRUCTURAL STEEL SHAPES (W)--- ------- ---- ---- --------- - fy = 50,000 psi <br />LIGHT GAUGE STEEL SHAPES (18 ga. OR LESS) ------ fy = 33,000 psi <br />LIGHT GAUGE STEEL SHAPES (16 ga. AND UP) --- ------------ -- fy = 50,000 psi <br />BOLTS FOR WOOD AND STEEL CONNECTIONS (U.N.O.) --- A307 <br />GENERAL NOTES: <br />1. THE FOLLOWING SPECIFICATIONS ARE AN OUTLINE OF MINIMUM MATERIAL REQUIREMENTS AND THEIR <br />APPLICATION. MANUFACTURER SPECIFICATION AND LOCAL CODE REQUIREMENTS, WHEN IN EXCESS OF <br />MINIMUM SPECIFICATION SHALL CONTROL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW AND <br />SUBMIT ALL SHOP DRAWINGS AND REPORT ALL DOCUMENT DISCREPANCIES TO THE STRUCTURAL <br />ENGINEER PRIOR TO FABRICATION OR ERECTION. <br />2. AT CONSTRUCTION ISSUE, THESE DRAWINGS REPRESENT STRUCTURAL COMPONENTS IN THEIR FINAL AND <br />FINISHED STATE. CONSTRUCTION PROCEDURES, BRACING, METHODS SAFETY PRECAUTIONS OR <br />MECHANICAL REQUIREMENTS USED TO ERECT THEM ARE THE SOLE RESPONSIBILITY OF THE GENERAL <br />CONTRACTOR OR SUBCONTRACTOR DOING THE WORK. <br />3. VERIFY ALL DETAILS AND DIMENSIONS WITH EXISTING CONDITIONS, ARCHITECTURAL DOCUMENTS AND <br />PROPERLY COORDINATED, APPROVED SHOP DRAWINGS. <br />4. NO COMMENT, NOTE OR DETAIL IN THESE STRUCTURAL DOCUMENTS SHOULD BE MISCONSTRUED AS A <br />DESIGN FOR WATERPROOFING OR DAMPPROOFING. SPECIFIC DESIGN FOR MOISTURE CONTROL AND <br />PERMANENT PROTECTION OF STRUCTURAL MATERIALS FROM THE ELEMENTS IS TO BE COMPLETED BY <br />OTHERS AND COORDINATED WITH THE STRUCTURAL DOCUMENTS. <br />FOUNDATION NOTES: <br />1. FOOTINGS SHALL BEAR ON SOIL SUITABLE FOR SUPPORTING 2000 P.S. NET ALLOWABLE BEARING. IF <br />QUESTIONABLE SOIL IS ENCOUNTERED, THE STRUCTURAL ENGINEER SHALL BE NOTIFIED IMMEDIATELY. <br />2. FOOTINGS SHALL BE POURED IMMEDIATELY AFTER EXCAVATION. <br />3. EXPANSION AND CONTROL JOINTS ARE TO BE PLACED PER A.C.I. RECOMMENDATIONS. PREPARE A CRACK <br />CONTROL PLAN BASED ON CONSTRUCTION SEQUENCING AND PROPOSED ACTUAL FLOOR AND WALL <br />FINISHES, AND SUBMIT TO THE ARCHITECT/ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. <br />3.1 NO CONTROL JOIN SHALL INTERSECT AN ADJACENT CONTROL JOINT AT AN ANGLE <90°. <br />3.2 CONTROL JOINTS SHALL ONLY INTERSECT A CURB OR OTHER STRUCTURAL MEMBER AT ANGLE OF <br />901. <br />4. ALL REINFORCING STEEL MARKED "CONTINUOUS" SHALL BE LAPPED PER "REINFORCING STEEL SPLICE <br />NOTES". <br />5. LAP TOP BARS AT CENTER OF SPAN; LAP BOTTOM BARS AT SUPPORTS, U.N.O. <br />6. THERE SHALL BE NO PLUMBING LINES RUNNING PARALLEL TO, WITHIN OR UNDER ANY FOUNDATION BEAM. <br />7. PLACE A 10 MIL VAPOR RETARDER OF POLYETHYLENE UNDER ALL CONCRETE SLABS, U.N.O. <br />8. ALL FOOTING BOTTOMS MUST BE PLACED A MINIMUM OF 12" BELOW FINISH GRADE. <br />11 <br />SITE WORK NOTES: <br />1. PERFORM EXCAVATION, ACCORDING TO GOOD COMMON CONSTRUCTION PRACTICES, TO THE LINES, <br />GRADES, ELEVATIONS INDICATED ON THE DRAWINGS AND ACCORDING TO RECOMMENDATIONS FOUND IN <br />SUB SURFACE REPORT BY GEOTECHNICAL ENGINEER. <br />2. ALL FILL UNDER SLABS AND FOUNDATIONS SHALL BE COMPACTED TO 98% OF MAXIMUM DENSITY <br />(MODIFIED PROCTOR TEST) AT OPTIMUM MOISTURE CONTENT. A COMPACTION REPORT FROM QUALIFIED <br />SOILS ENGINEER SHALL BE TAKEN AND SUBMITTED TO ENGINEER OF RECORD. <br />3. PROVIDE SOIL POISONING TO CONTROL TERMITES AS REQUIRED BY GOVERNING CODES. <br />MASONRY NOTES: <br />1. VERIFY ALL DETAILS AND DIMENSIONS WITH EXISTING CONDITIONS, ARCHITECTURAL DOCUMENTS AND <br />PROPERLY COORDINATED APPROVED SHOP DRAWINGS. <br />2. EXPANSION AND CONTROL JOINTS ARE TO BE PLACED PER A.C.I. RECOMMENDATIONS. PREPARE A CRACK <br />CONTROL PLAN BASED ON CONSTRUCTION SEQUENCING AND PROPOSED ACTUAL FLOOR AND WALL <br />FINISHES, AND SUBMIT TO THE ARCHITECT/ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. <br />3. THE MASONRY CONTRACTOR MUST EMPLOY A CERTIFIED STRUCTURAL MASONRY INSPECTOR. THE <br />INSPECTOR MUST BE IN ATTENDANCE AND MONITOR ALL REINFORCED MASONRY OPERATIONS INCLUDING <br />DOWEL PLACEMENT. PROVIDE DAILY REPORTS TO THE ENGINEER OF RECORD. <br />4. PROVIDE 48 BAR DIAMETER MINIMUM LAP. <br />5. PROVIDE CONTINUOUS TRUSS TYPE OR LADDER TYPE #9 GAUGE GALVANIZED HORIZONTAL JOINT <br />REINFORCEMENT AT 16 O.C. <br />CONCRETE FOUNDATION NOTES AND SPECIFICATIONS: <br />1. ALL CONCRETE WORK SHALL CONFORM TO THE "A.C.I. BUILDING CODE", ACI 318 AND ACI 301, LATEST <br />EDITION. <br />2. DETAILING, FABRICATION AND PLACING OF REINFORCING STEEL SHALL BE IN ACCORDANCE WiTH ACI <br />315-99, "ACI DETAILING MANUAL - 1999." <br />3. UNLESS OTHERWISE NOTED, ALL REINFORCING BARS SHALL CONFORM TO ASTM A-615 GRADE 60 (60,000 <br />PSI YIELD). REINFORCING SHALL BE FREE FROM OIL, DIRT AND OTHER MATERIALS THAT WOULD REDUCE <br />THE BOND WITH THE CONCRETE. <br />4. WELDED WIRE REINFORCING (WWR) SHALL CONFORM TO ASTM A-185. WELDING WIRE REINFORCING SHALL <br />BE CHAIRED TO MAINTAIN THE REINFORCING AT ONE-THIRD THE DEPTH BELOW THE TOP SURFACE DURING <br />CONCRETE PLACEMENT. SUPPORTS SHALL BE AT 2'-O" O.C. EACH WAY. LAP WELDED WIRE MESH ONE FULL <br />MESH AT SIDE AND END LAPS. <br />5. UNLESS OTHERWISE NOTED, CONCRETE PROTECTION FOR REINFORCING SHALL BE AS SPECIFIED IN THE <br />"A.C.I. BUILDING CODE", (ACI 318 LATEST EDITION). <br />6. CONCRETE STRENGTH AND PROTECTION FOR REINFORCEMENT OF POURED -IN -PLACE MEMBERS; SEE <br />SECTION 7.7 ACI 318 LATEST EDITION. <br />CONCRETE <br />COVER, IN. <br />A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH ................ 3 <br />B. CONCRETE EXPOSED TO EARTH OR WEATHER: <br />B.1. NO. 6 THROUGH NO. 18 BARS........................................................................... 2 <br />B.2. NO. 5 BAR, W31 OR D31 WIRE, AND SMALLER ................................................ 11 <br />C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: <br />C.1. SLABS, WALLS, JOISTS: <br />C.1.1. NO. 14 AND NO. 18 BARS......................................................................... 1 <br />C.1.2. NO. 11 BAR AND SMALLER...................................................................... a <br />C.2. BEAMS, COLUMNS: <br />C.2.1. PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS .................... 12 <br />C.3. SHELLS, FOLDED PLATE MEMBERS: <br />3 <br />C.3.1. NO, 6 BAR AND LARGER .................. ........................................................ q <br />C.3.2. NO. 5 BAR, W31 OR D31 WIRE, AND SMALLER .................................... 2 <br />7. NO WATER SHALL BE ADDED TO THE CONCRETE AT THE JOBSITE. IT SHALL BE THE RESPONSIBILITY OF THE <br />CONTRACTOR TO COORDINATE WITH THE CONCRETE SUPPLIER TO ENSURE A PUMPABLE AND WORKABLE <br />MIX WITHOUT THE ADDITION OF WATER AT THE JOBSITE. THE USE OF PLASTICIZERS, RETARDANTS AND <br />OTHER ADDITIVES SHALL BE AT THE OPTION OF THE CONTRACTOR SUBJECT TO THE APPROVAL OF THE <br />STRUCTURAL ENGINEER. FOLLOW THE RECOMMENDATIONS OF THE MANUFACTURER FOR THE PROPER <br />USE OF ADDITIVES. THE USE OF CALCIUM CHLORIDE OR OTHER CHLORIDE BEARING SALTS SHALL NOT BE <br />PERMITTED. <br />8. CONCRETE SLUMP TESTS SHALL BE MADE BEFORE AND AFTER THE ADDITION OF ADMIXTURES AND MAY BE <br />TAKEN AT THE BACK OF THE TRUCK. CONCRETE FOR THE PREPARATION OF TEST CYLINDERS SHALL BE <br />TAKEN FROM THE HOSE END FOR CONCRETE PLACED BY PUMP. <br />9. REINFORCING STEEL SPLICE NOTES: <br />9.1. ALL REINFORCING STEEL SHALL BE SPLICED AS NOTED BELOW AND AS REQUIRED IN THE A.C.I. <br />BUILDING CODE (LATEST EDITION). <br />9.1.1. LID NOTED IN THE DETAILS AND TABLES BELOW IS THE STRAIGHT BAR DEVELOPMENT LENGTH PER <br />ACI-318. <br />9.1.2. CLASS B LAP SPLICE TABLE SHALL BE USED FOR ALL LAP SPLICES AND BAR DEVELOPMENT <br />UNLESS NOTED OTHERWISE. <br />9.1.3. ALL REINFORCING STEEL MARKED "CONTINUOUS" SHALL BE LAPPED WITH A CLASS B LAP SPLICE <br />AND AROUND CORNERS OR INTERSECTIONS WITH A STANDARD 90 DEGREE HOOK. <br />9.1.4. SPLICE TOP BARS AT CENTER OF SPAN, SPLICE BOTTOM BARS AT SUPPORTS WITH CLASS B LAP <br />SPLICE. <br />9.1.5. SPLICE ALL VERTICAL BARS IN COLUMNS AND VERTICAL AND HORIZONTAL BARS IN SHEAR WALLS <br />WITH A CLASS B LAP SPLICE UNLESS NOTED OTHERWISE. <br />9.1.6. LAP SPLICES FOR #14 AND LARGER BARS SHALL BE MADE WITH MECHANICAL COUPLERS TO <br />DEVELOP 125% OF THE BARS CAPACITY. <br />9.1.7. INCREASE DEVELOPMENT LENGTH SHOWN IN TABLES BELOW BY 1.25 FOR 75 KSI STEEL. <br />9.1.8. INCREASE DEVELOPMENT LENGTH SHOWN IN TABLES BELOW BY 1.50 FOR EPDXY COATED BARS. <br />9.1.9. INCREASE DEVELOPMENT LENGTH SHOWN IN TABLES BELOW BY 1.30 IF BAR IS TO BE USED AS A <br />TOP BAR IN A BEAM OR SLAB WITH 12" OF FRESH CONCRETE BELOW THE BAR. <br />9.1.10. THE FOLLOWING TABLES ASSUME ONE OF THE BELOW CONDITIONS, PER ACI, ARE MET: <br />9.1.10.1. CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED IS NOT LESS THAN db, CLEAR <br />COVER NOT LESS THAN db AND STIRRUPS OR TIES THROUGHOUT Ld NOT LESS THAN CODE <br />MINIMUM. <br />9.1.10.2. CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED NOT LESS THAN 2 db AND CLEAR <br />COVER NOT LESS THAN db. <br />9.2. ALL HOOKED REINFORCING STEEL SHALL BE AS NOTED BELOW AND AS REQUIRED IN THE A.C.I. <br />BUILDING CODE (LATEST EDITION). <br />9.2.1. Lhb NOTED IN THE SCHEDULE BELOW IS THE BASIC TENSION DEVELOPMENT LENGTH FOR <br />STANDARD A.C.I. HOOKS, MEASURED FROM THE CRITICAL SECTION TO THE END OF THE HOOK. <br />9.2.2. Ldh = 1.25*Lhb FOR 75 KSI STEEL. <br />9.2.3. Ldh = 1.2*Lhb FOR EPDXY COATED REINFORCING BARS. <br />9.2.4. Ldh = Lhb UNLESS CONDITIONS NOTED IN B. OR C. ARE NEEDED AND SHALL NOT BE LESS THAN 6" <br />OR 8 BAR DIAMETERS. <br />10. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ANY OTHER <br />ADDITIONAL SLEEVES, ANCHORS, VENT OPENINGS, ETC., NOT SHOWN ON STRUCTURAL PLANS THAT MIGHT <br />BE REQUIRED. <br />11. PLACE CONCRETE IN A MANNER SO AS TO PREVENT SEGREGATION OF THE MIX. DELAY FLOATING AND <br />TROWELING OPERATIONS UNTIL CONCRETE HAS LOST SURFACE WATER SHEEN OR ALL FREE WATER. DO <br />NOT SPRINKLE FREE CEMENT ON THE SLAB SURFACE. FINISHING OF SLAB SURFACES SHALL COMPLY WITH <br />THE RECOMMENDATIONS OF ACI 302.1 AND 304. <br />12. PROVIDE 7 DAY CURING OF SLAB IMMEDIATELY AFTER FINISHING. <br />13. PROTECT THE CONCRETE SURFACE BETWEEN FINISHING OPERATIONS ON HOT, DRY DAYS OR ANY OTHER <br />TIME THAT PLASTIC SHRINKAGE CRACKS COULD DEVELOP BY USING WET BURLAP, PLASTIC MEMBRANE OR <br />FOGGING. PROTECT CONCRETE SLAB AT ALL TIMES FROM RAIN, HAIL OR OTHER INJURIOUS EFFECT. ANY <br />AND ALL MATERIALS USED FOR CONCRETE PROTECTION SHALL BE CHECKED FOR COMPLIANCE WITH <br />FINISH FLOOR MATERIALS. <br />14. RESHORING WHEN REQUIRED, TO EXTEND AT LEAST TWO FLOORS BELOW FLOOR SUPPORTING <br />PROCEDURE TO BE SUBMITTED TO STRUCTURAL ENGINEER FOR APPROVAL. <br />15. AN INDEPENDENT CERTIFIED TESTING LAB SHALL VERIFY AND PROVIDE REPORTS CERTIFYING THE <br />FOLLOWING: <br />15.0.1. CONCRETE PLANT BATCH TICKETS FOR EACH TRUCK VERIFY THAT THE CONCRETE MATCHES THE <br />APPROVED DESIGN MIX. <br />15.0.2. CONCRETE SLUMP IS IN ACCORDANCE WITH APPROVED DESIGN MIX. <br />15.0.3. CONCRETE PLACEMENT OPERATIONS ARE IN ACCORDANCE WITH ACI SPECIFICATIONS. <br />15.0.4. CONTROL JOINTS ARE INSTALLED WITHIN THE ACI TIME ALLOWANCE. <br />15.0.5. FALSEWORK (OR GROUND FLOOR), LAYOUT AND PROPER CURING METHODS ARE BEING UTILIZED. <br />16. NO CONCRETE SHALL BE PLACED OUTSIDE OF THESE SPECIFICATIONS WITHOUT THE OWNER'S PRIOR <br />APPROVAL. DISCREPANCIES WITH THE OUTLINED SPECIFICATION SHALL BE REPORTED TO THE OWNER <br />AND STRUCTURAL ENGINEER WITHIN 24 HOURS. <br />POST -INSTALLED ANCHOR NOTES <br />1. POST -INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION <br />DOCUMENTS. <br />2. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO <br />INSTALLING POST -INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. <br />3. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW SHALL BE SUBMITTED <br />BY THE CONTRACTOR TO THE ENGINEER -OF -RECORD ALONG WITH CALCULATIONS THAT ARE PREPARED & <br />SEALED BY A REGISTERED PROFESSIONAL ENGINEER.THE CALCULATIONS SHALL DEMONSTRATE THAT <br />THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERTINENT EQUIVALENT PERFORMANCE <br />VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR <br />STANDARD(S) AS REQUIRED BY THE BUILDING CODE. <br />4. CARE SHALL BE TAKEN IN PLACING POST -INSTALLED ANCHORS TO AVOID CONFLICTS WITH EXISTING <br />REBAR. <br />5. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN <br />INSTRUCTIONS. <br />6. PROVIDE CONTINUOUS SPECIAL INSPECTION FOR ALL MECHANICAL AND ADHESIVE ANCHORS PER THE <br />APPLICABLE EVALUATION REPORT. <br />7. CONTACT MANUFACTURER'S REPRESENTATIVE FOR THE INITIAL TRAINING AND INSTALLATION OF <br />ANCHORS AND FOR PRODUCT RELATED QUESTIONS AND AVAILABILITY. <br />STRUCTURALSTEEL: <br />1. ALL STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING ASTM SPECIFICATIONS, UNLESS NOTES <br />OTHERWISE ON PLAN: <br />ROLLED W SHAPES ASTM A992, GRADE 50 <br />ROLLED C & MC SHAPES ASTM A36 <br />ANGLES ASTM A36 <br />ROUND HSS ASTM A500, GR B (Fy=42 KSI) <br />RECTANGULAR HSS ASTM A500, GR B (Fy=46 KSI) <br />2. ALL SHOP AND FIELD WELDING SHALL CONFORM TO AWS STRUCTURAL WELDING CODE, ANSI/AWS D1.1. <br />3. DESIGN CONNECTIONS FOR ALL BEAMS TO SUPPORT HALF OF THE UNIFORM CAPACITY SHOWN IN AISC <br />"TABLES FOR ALLOWABLE LOADS ON BEAMS" FOR THE GIVEN SECTION AND SPAN UNLESS OTHERWISE <br />SHOWN ON PLANS. <br />4. GROUT BELOW BASE PLATES SHALL BE NON -SHRINK, NON-METALLIC GROUT WITH A MINIMUM <br />COMPRESSIVE STRENGTH OF 6000 PSI. <br />5. HOT -DIP GALVANIZE ALL STRUCTURAL STEEL ITEMS AND THEIR CONNECTIONS PERMANENTLY EXPOSED TO <br />WEATHER AFTER FABRICATION. <br />OPEN WEB STEEL JOISTS: <br />1. ALL STEEL JOISTS SHALL CONFORM TO THE STANDARDS OF THE STEEL JOIST INSTITUTE. <br />2. THE JOISTS SHOWN IN THE DRAWINGS ARE THE MINIMUM SIZE REQUIRED. <br />3. ALL JOISTS ARE TO BE CAMBERED PER SJI STANDARDS. <br />4. PROVIDE A MINIMUM END BEARING ON STEEL SUPPORTS AS REQUIRED BY SJI. STAGGER THE ENDS OF <br />JOISTS IF NECESSARY. <br />5. PROVIDE HORIZONTAL OR DIAGONAL TYPE BRIDGING FOR ALL JOISTS PER SJI SPECIFICATIONS. ANCHOR <br />ALL ENDS OF BRIDGING LINES THAT TERMINATE AT WALLS OR BEAMS. <br />6. PROVIDE ALL JOISTS AND ACCESSORIES WITH ONE SHOP -COAT OF PAINT AS SPECIFIED IN SJI STANDARDS <br />7. JOIST SEATS SHALL BE A UNIFORM DEPTH OF 2-1/2" AND BE WELDED TO ALL SUPPORTS WITH A MINIMUM <br />OF TWO 6' BY 2" LONG FILLET WELDS, OR AS REQUIRED FOR UPLIFT. <br />8. ALL ITEMS SUCH AS MECHANICAL EQUIPMENT, DUCT WORK, PIPES, CEILING SUPPORTS, FIXTURES, <br />DISPLAYS, ETC., WHICH ARE TO BE SUPPORTED BY, OR HUNG FROM, STEEL JOISTS SHALL BE FRAMED <br />WITH AUXILIARY FRAMING TO THE PANEL POINTS OF THE STEEL JOIST OR GIRDER WHEN THE <br />CONCENTRATED LOAD EXCEEDS 50 LBS. METHODS OF FRAMING THAT INDUCE BENDING IN THE STEEL <br />JOIST CHORDS OR WEB MEMBERS WILL NOT BE PERMITTED. <br />9. ADDITIONAL DESIGN LOADS FROM ARCHITECTURAL FEATURES, ROOFTOP EQUIPMENT, OR ANY OTHER <br />CONCENTRATED LOADS SHOWN ON THE DRAWINGS, SHALL BE CONSIDERED AS ADDITIONAL COLLATERAL <br />LOADS. <br />METAL DECKS: <br />1. THE METAL DECK AND INSTALLATION ARE TO COMPLY WITH THE REQUIREMENTS OF THE STEEL DECK <br />INSTITUTE (SDI). <br />2. REFERENCE CONSTRUCTION DOCUMENTS FOR TYPE, SIZE, GAUGE AND FINISH OF METAL DECK. <br />3. DECK SHALL BE PLACED IN A MINIMUM TWO SPAN CONDITION. SINGLE SPANS ARE NOT PERMITTED UNLESS <br />SPECIFICALLY SHOWN IN THE DOCUMENTS. <br />4. PROVIDE A MINIMUM BEARING AT 2" AT ALL SUPPORTS. <br />5. WELDING OF DECK SHALL BE IN ACCORDANCE WITH ANSI/AWS D1.3 "STRUCTURAL WELDING CODE - SHEET <br />STEEL." <br />6. STEEL DECK SHALL BE STORED OFF THE GROUND WITH ONE END ELEVATED TO PROVIDE DRAINAGE. <br />7. DO NOT ATTACH ANY ITEMS SUCH AS LIGHT FIXTURES, DUCTS, HANGING SOFFITS AND PIPING TO THE <br />METAL ROOF DECK WITHOUT WRITTEN APPROVAL BY THE ENGINEER. <br />SUBMITTALS: <br />1. THE GENERAL CONTRACTOR SHALL SUBMIT FOR ENGINEER REVIEW SHOP DRAWINGS FOR THE FOLLOWING <br />ITEMS: <br />1, 1. REINFORCING STEEL <br />1.2. CONCRETE MIX DESIGN <br />1.3. STRUCTURAL STEEL <br />1.4. METAL DECKS <br />1.5. OPEN WEB STEEL JOISTS (*) <br />1.6. MASONRY PRODUCTS INCLUDING VERIFICATION OF fm AND CERTIFICATES FOR ALL OTHER MATERIALS <br />USED IN MASONRY CONSTRUCTION INDICATING THE COMPLIANCE WITH THE CONTRACT DOCUMENTS. <br />1.7. EMBEDDED ITEMS (PLATES, ANGLES, BOLTS, ETC.) <br />1.8. PRE-ENGINEERED ALUMINUM CANOPY (*) <br />ALL ITEMS MARKED (*) SHALL HAVE SHOP DRAWINGS SIGNED, SEALED, AND DATED BY A REGISTERED <br />ENGINEER IN THE STATE OF FLORIDA. <br />2. ALL SHOP DRAWINGS MUST BE REVIEWED AND STAMPED BY THE GENERAL CONTRACTOR PRIOR TO <br />SUBMITTAL. <br />3. SUBMIT ALL MANUFACTURERS LITERATURE FOR ALL MATERIALS AND PRODUCTS USED IN CONSTRUCTION <br />ON THE PROJECT. <br />CLASS A SPLICE (USE ONLY IF NOTED ON DRAWINGS) <br />A.C.I. REINFORCING DEVELOPMENT LENGTH SCHEDULE (Ld) <br />CONCRETE STRENGTH (PSI) <br />REINF. SIZE <br />3000 <br />4000 <br />5000 <br />6000 <br />7000 <br />8000 <br />10000 <br />12000 <br />#3 - <br />17" <br />15" <br />13" <br />12" <br />12" <br />12" <br />12" <br />12" <br />#4 <br />22" <br />19" <br />17" <br />16" <br />15" <br />14" <br />12" <br />12" <br />#5 <br />28" <br />24" <br />22" <br />20" <br />18" <br />17" <br />12" <br />12" <br />#6 <br />33" <br />29" <br />26" <br />24" <br />22" <br />21" <br />15" <br />15" <br />47 <br />48" <br />42" <br />38" <br />34" <br />32" <br />30" <br />27" <br />27" <br />98 <br />55" <br />48" <br />43" <br />39" <br />36" <br />34" <br />30" <br />30" <br />#9 <br />52" <br />54" <br />48" <br />44" <br />41" <br />38" <br />34" <br />34" <br />#10 <br />70" <br />61" <br />54" <br />50" <br />46" <br />43" <br />39' <br />39" <br />#11 <br />78" <br />67" <br />60" <br />55" <br />51" <br />48" <br />43" <br />43" <br />CLASS B SPLICE (TO BE USED U.N.O.) <br />A.C.I. REINFORCING DEVELOPMENT LENGTH SCHEDULE (1.3 Ld) <br />CONCRETE STRENGTH (PSI) <br />REINF. SIZE <br />3000 <br />4000 <br />5000 <br />6000 <br />7000 <br />8000 <br />10000 <br />12000 <br />#3 <br />23" <br />20" <br />17" <br />16" <br />16" <br />16" <br />16" <br />16" <br />#4 <br />29" <br />25" <br />23" <br />21" <br />20" <br />19" <br />16" <br />16" <br />#5 <br />37" <br />32" <br />29" <br />26" <br />24" <br />23" <br />16" <br />16" <br />#6 <br />43" <br />38" <br />34" <br />32" <br />29" <br />28" <br />20" <br />20" <br />97 <br />63" <br />55" <br />50" <br />45" <br />42" <br />39" <br />36" <br />36" <br />98 <br />72" <br />63" <br />56" <br />51" <br />47" <br />45" <br />39" <br />39" <br />#9 <br />Bill <br />71" <br />63" <br />5F <br />54" <br />50" <br />45" <br />45" <br />#10 <br />91" <br />80" <br />71" <br />66' <br />60" <br />56" <br />51" <br />51" <br />#11 <br />j 102" <br />1 88" <br />1 78" <br />1 72' <br />1 67" <br />63" <br />56" <br />W <br />A.C.I. STANDARD HOOK REINFORCING DEVELOPMENT LENGTH SCHEDULE (Lhb) <br />CONCRETE STRENGTH (PSI) <br />REINF. SIZE <br />3000 <br />4000 <br />5000 <br />6000 <br />7000 <br />8000 <br />9000 <br />10000 <br />#3 <br />9" <br />8" <br />7" <br />6' <br />fill <br />fill <br />6" <br />fill <br />#4 <br />11" <br />10" <br />9" <br />8" <br />8" <br />7" <br />7" <br />6, <br />#5 <br />14" <br />12" <br />11" <br />10" <br />9" <br />9" <br />F. <br />8" <br />#6 <br />17" <br />16. <br />13" <br />12" <br />11" <br />11" <br />10" <br />9" <br />#7 <br />20" <br />IT <br />15" <br />14" <br />131, <br />IT <br />12" <br />11° <br />#8 <br />22" <br />19" <br />17" <br />16" <br />15" <br />14" <br />13" <br />12" <br />#9 <br />25" <br />22" <br />20" <br />18" <br />17" <br />16" <br />15" <br />14" <br />#10 <br />28" <br />25" <br />22" <br />20" <br />19" <br />18" <br />17" <br />16" <br />#11 <br />31" <br />27" <br />24" <br />22" <br />21" <br />19" <br />18" <br />17" <br />Ldh <br />CRITICAL <br />SECTION <br />Ldh --I <br />CRITICAL <br />SECTION <br />SYMBOLS AND ABBREVIATIONS: <br />HSS = HOLLOW STRUCTURAL SECTION <br />SJI = STEEL JOIST INSTITUTE <br />ADUL = ADDITIONAL <br />K.O. = KNOCKOUT <br />SL = STEEL LINE <br />ARCH. = ARCHITECTURAL <br />LBS = POUNDS <br />SYP = SOUTHERN YELLOW PINE <br />BL = BUILDING LINE <br />LLH = LONG LEG HORIZONTAL <br />T&B = TOP AND BOTTOM <br />B.O.B. = BOTTOM OF BEAM <br />LLV = LONG LEG VERTICAL <br />T.O.B. = TOP OF BEAM <br />B.O.C.P. = BOTTOM OF CAP PLATE <br />MAX = MAXIMUM <br />T.O.S.O.G. - TOP OF SLAB ON GRADE <br />C.I.P. = CAST IN PLACE <br />M.C.J. = MASONRY CONTROL JOINT <br />T.O.C. = TOP OF COLUMN <br />cj = CONTROL JOINT <br />MEP = MECHANICAL, ELECTRICALAND PLUMBING T.O.C.P. = TOP OF CAP PLATE <br />CL = CENTER LINE <br />MIN = MINIMUM <br />T.O.F. = TOP OF FOOTING <br />CFS = COLD FORMED STEEL <br />N.T.S. = NOT TO SCALE <br />T.O.J.B = TOP OF JOIST BEARING <br />CMU = CONCRETE MASONRY UNIT <br />O.C. = ON CENTER <br />T.O.M. = TOP OF MASONRY <br />CONC. = CONCRETE <br />PL = PLATE <br />TS = TUBE STEEL <br />CONT. = CONTINUOUS <br />PLF = POUNDS PER LINEAR FOOT <br />U.N.O. = UNLESS NOTED OTHERWISE <br />E.F. = EACH FACE <br />PSF = POUNDS PER SQUARE FEET <br />VERT. = VERTICAL <br />E.W. = EACH WAY <br />PSI = POUNDS PER SQUARE INCH <br />V.I.F. = VERIFY IN FIELD <br />EXP. = EXPANSION <br />P.T. = PRESERVATIVE TREATED <br />WWR = WELDED WIRE REINFORCEMENT <br />F.F. = FINISH FLOOR <br />REINF. = REINFORCEMENT <br />W/ = WITH <br />FT = FEET <br />REQ'D = REQUIRED <br />& = AND <br />GA. = GAUGE <br />0 = DIAMETER <br />GALV = GALVANIZED <br />° = DEGREES <br />HORZ = HORIZONTAL <br />COMPONENTS AND CLADDING WIND PRESSURE CHART <br />COMPONENTS AND CLADDING <br />COMPONENTS AND CLADDING <br />ULTIMATE PRESSURE SCHEDULE <br />ULTIMATE PRESSURE SCHEDULE <br />WALLS, DOORS AND WINDOWS <br />ROOFS <br />ENCLOSED BUILDING <br />ENCLOSED BUILDING <br />GCp +/- 0.18 <br />GCPI=+/- 0.18 <br />(+) INDICATES INWARD; (-) INDICATES OUTWARD <br />(+) INDICATES INWARD; (-) INDICATES OUTWARD <br />NOT WITHIN a' OF <br />EFFECTIVE AREA OF <br />WITHIN a' OF <br />NOT WITHIN a' OF <br />EFFECTIVE AREA OF <br />WITHIN a' OF <br />CORNER BUT <br />NOT WITHIN a' OF <br />CORNER, EAVE OR <br />COMPONENT <br />CORNER <br />CORNER <br />COMPONENT <br />CORNER <br />WITHIN a' OF EAVE <br />OR TRANSITION <br />TRANSITION <br />0 S.F. < "AREA" < 10 S.F. <br />+35.1 -46.8 <br />+35.1 -38.0 <br />0 S.F. < "AREA" < 10 S.F. <br />+15.6 -96.9 <br />+15.6 -64.4 <br />+15.6 -38.4 <br />20 S.F. < "AREA" < 50 S.F. <br />+33.5 -43.6 <br />+33.5 -36.4 <br />20 S.F. < "AREA" < 50 S.F. <br />+14.6 -80.0 <br />+14.6 -57.5 <br />+14.6 -37.4 <br />50 S.F. < "AREA" < 100 S.F. <br />+31.5 -39.7 <br />+31.5 -34.5 <br />50 S.F. < "AREA" < 100 S.F. <br />+13.3 -58.2 <br />+13.3 -48.4 <br />+13.3 -36.1 <br />100 S.F. < "AREA" < 500 S.F. <br />+28.3 33.5 <br />+28.3 -31.2 <br />> 100 S.F. <br />+12.4 -41.6 <br />+12.4 -41.6 <br />+12.4 -35.1 <br />> 500 S.F. <br />1 +26.3 -29.3 <br />1 +26.3 -29.3 <br />NOTES: ALL BUILDING ELEMENTS EXPOSED TO WIND SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS TO RESIST <br />THE WIND PRESSURES INDICATED AND TO MEET OTHER CODE REQUIREMENTS FOR AIR AND WATER INTRUSION. <br />WIND LOADS ABOVE ARE ULTIMATE LOADS. USE ULTIMATE WIND PRESSURE W/ ASCE7-10 LOAD COMBINATIONS, <br />MULTIPLY LOADS BY 0.6 TO OBTAIN NOMINAL LOADS. <br />SHEET INDEX <br />SHEET DESIGNATION <br />DESCRIPTION <br />S0.0 <br />DESIGN CRITERIA <br />S1.0 <br />FOUNDATION AND SLAB PLAN <br />S1.1 <br />LOW FRAMING PLAN <br />S1.2 <br />HIGH FRAMING PLAN <br />S2.0 <br />SECTION <br />S2.1 <br />SECTION <br />S2.2 <br />SECTION <br />S2.3 <br />SECTION <br />S3.0 <br />STRUCTURAL DETAILS <br />SM <br />STRUCTURAL DETAILS <br />S3.2 <br />STRUCTURAL DETAILS <br />S3.3 <br />STRUCTURAL DETAILS <br />S4.0 <br />STRUCTURAL FABRICATION DETAILS <br />S4.1 <br />STRUCTURAL FABRICATION DETAILS <br />S4.2 <br />STRUCTURAL FABRICATION DETAILS <br />r <br />w <br />O <br />w <br />- LL <br />i-aU_ <br />NJ <br />L1 <br />joa <br />w <br />= fA <br />'.L d <br />00) <br />UQ <br />Q <br />cn w <br />00 <br />�a <br />J <br />LL <br />QZ <br />uo <br />M <br />rn rn m <br />M_ M o) <br />CV <br />a. u- U <br />2 <br />O <br />15, � U <br />m OZ 2 w <br />U) N Z <br />=)co Z <br />C? <br />co W <br />w <br />QQm <br />�0. <br />LL o _j En U Z Lu <br />J <br />W <br />LL W 0 Z Q Z< u) 0 <br />Lu <br />m1lw�ww-rw=m <br />ww_j m 2 D 6 -F-w <br />W O m c V w W <br />H Z Q U- Q U Q Z - W" <br />OQww=Z"OJgW <br />~wH WWRF=�w0 <br />1--(5-M 0❑z-1 <br />}_j 5 -wi,-wwm <br />U u �o=) wm(°-'(n<n <br />1=Z=z�z=o�QO <br />0.YH-QUO~O W 0. <br />V}�- w7U1=-- w <br />-�O O O w <br />w <br />Q <br />10 <br />Z <br />0 <br />0 <br />W <br />fy <br />ERNI E <br />c 0 <br />J <br />U <br />< <br />J <br />LL <br />J <br />J <br />m <br />Q <br />Q <br />J <br />CL <br />Y= <br />tl d <br />W <br />W <br />JOB NO. <br />E1�9-208 `` " _ <br />DATE <br />08/27/201 ''y <br />DRAWN <br />AG <br />DESIGN <br />AG <br />FOUNDATION AND SLAB <br />PLAN <br />FOR REVIEW AND PERMIT. NOT FOR CONSTRUCTION UNTIL APPROVED BY THE OWNER AND THE BUILDING OFFICIAL. THEN MUST BE MARKED "APPROVED FOR CONSTRUCTION" BY THE ENGINEER. <br />81.0 <br />