Laserfiche WebLink
GENERAL STRUCTURAL NOTES: <br />1. ALL WORK SHALL CONFORM TO THE 2020 EDITION OF THE FLORIDA (INTERNATIONAL) <br />RESIDENTIAL CODE AND APPLICABLE COUNTY CODE AMENDMENTS. STANDARDS LISTED IN <br />STRUCTURAL NOTE SECTIONS REFER TO THE VERSION AND EFFECTIVE DATE IDENTIFIED IN THE <br />REFERENCED STANDARDS CHAPTER IN THE GOVERNING BUILDING CODE NOTED ABOVE. <br />2. THE STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS. SHOULD CONFLICTS <br />EXIST BETWEEN THE DRAWINGS AND THE STRUCTURAL NOTES, THE STRICTEST PROVISION <br />SHALL GOVERN. <br />3. THE STRUCTURAL DRAWINGS FORM AN INTEGRAL PART OF CONTRACT DOCUMENTS, WHICH <br />• INCLUDE ARCHITECTURAL, STRUCTURAL. MECHANICAL, ELECTRICAL, AND CML/SITE DRAWINGS. <br />COORDINATE THE STRUCTURAL DRAWINGS WITH THE REQUIREMENTS SHOWN IN THE OTHER <br />COMPONENTS OF THE CONTRACT DOCUMENTS. <br />4. TYPICAL DETAILS AND OTHER SECTIONSNETNLS APPLY TO CONDITIONS THAT ARE SIMILAR TO <br />THE CONDITIONS DESCRIBED IN THE SECTIONS/DETAILS, EVEN IF THEY ARE NOT SPECIFICALLY <br />REFERENCED ON THE PLANS. <br />S. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS, METHODS SEQUENCES AND <br />PROCEDURES OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO TEMPORARY SHORING AND <br />BRACING. <br />6. DO NOT SCALE STRUCTURAL DRAWINGS. IF DIMENSIONS ARE OMITTED OR NOT CLEAR, <br />CONTACT THE ENGINEER. <br />7. CONSTRUCTION SHALL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF OSHA AND THE <br />LOCAL GOVERNING CODES, CURRENT EDITION, AND ALL REQUIREMENTS SPECIFIED IN THE <br />CODES SHALL BE ADHERED TO AS IF THEY WERE CALLED FOR OR SHOWN ON THE DRAWINGS. <br />THIS SHALL NOT BE CONSTRUED TO MEAN THAT REQUIREMENTS SET FORTH ON THE DRAWING <br />MAY BE MODIFIED BECAUSE THEY ARE MORE STRINGENT THAN THE CODE REQUIREMENTS OR <br />BECAUSE THEY ARE NOT SPECIFICALLY REQUIRED BY CODE. <br />8. THE ENGINEER'S SEAL APPLIES ONLY TO THE STRUCTURAL COMPONENTS ON THIS DOCUMENT. <br />ALL DIMENSIONS ARE TO BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS, ANY DEVIATIONS <br />OR DISCREPANCIES ON THESE PLANS MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF <br />THE ENGINEER OF RECORD. BACK CHARGES WILL NOT BE ACCEPTED, REGARDLESS OF FAULT, <br />WITHOUT PRIOR NOTIFICATION BY BUILDER WITHIN 48-H0URS AND INVESTIGATION BY <br />FIELDSTONE. <br />9. THE TERMS'CONCRETE SCREW AND MASONRY SCREW SHALL BE USED INTERCHANGEABLY <br />WITHIN THESE DRAWINGS. CONCRETE/MASONRY SCREWS AS GENERICALLY SPECIFIED WITHIN <br />THESE DRAWINGS SHALL REFER TO ONE OF THE FOLLOWING ACCEPTED MANUFACTURER <br />PRODUCTS: SIMPSON STRONG TIE TITEN TURBO, GENUINE TAPCON, OR HILTI OUIK CON II. <br />DESIGN CRITERIA: <br />1. BUILDING RISK CATEGORY =II <br />2. VERTICAL LOADING: <br />ROOF TOP CHOIR LIVE LOAD =20 PSF (REDUCIBLE) <br />ROOF TOP CHORD DEAD LOAD =10 PSF <br />ROOF TOP CHORD DEAD LOAD (TILE) =15 PSF <br />ROOF BOTTOM CHORD LIVE LOAD (w/ STORAGE)= 20 PSF <br />ROOF BOTTOM CHORD LIVE LOAD (W/o STORAGE)= 10 PSF <br />ROOF BOTTOM CHORD DEAD LOAD =10 PSF <br />FLOOR LINE LOAD -40 PSF <br />FLOOR UVE LOAD (SLEEPING ROOMS) =30 PSF <br />FLOOR DEAD LOAD =15 PSF <br />DECK(BALCONY LIVE LOAD =40 PSF <br />EXTERIOR FRAME WALLS <br />w/OSB =10 PSF <br />W/STUCCO -15 PSF <br />w/BRICK -45 PSF <br />INTERIOR WOOD WALL =7 PSF <br />STAIRSAANDINGS -40 PSF <br />SNOW CRITERIA: <br />GROUND SNOW LOAD (PO) =0 PSF <br />SLOPED ROOF SNOW LOAD (Ps) =0 PSF <br />EXPOSURE FACTOR (Cal =1.0 <br />IMPORTANCE FACTOR (4) =1.0 <br />THERMAL FACTOR <br />ROOF SLOPE FACTOR <br />SNOW LOADS ADJACENT VERTICAL PROJECTIONS 8 LOW ROOFS ADJACENT TO HIGH <br />ROOF ARE INCREASED FOR THE EFFECT OF DRIFTING <br />3. LATERAL LOADING <br />WIND CRITERIA: <br />BASIC WIND SPEED =140 MPH <br />EXPOSURE CATEGORY =C <br />INTERNAL PRESSURE COEFFICIENT = +/- 0.18 (ENCLOSED) <br />SEISMIC CRITERIA <br />SITE CLASS -D <br />SEISMIC DESIGN CATEGORY =A <br />4. EARTH PRESSURE LOADING: <br />ALLOWABLE SOIL BEARING CAPACITY <br />TOTAL LOADS (INCLUDING WIND S, SEISMIC) =20DO PSF <br />LATERAL EARTH EQUIVALENT FLUID PRESSURE <br />WALLS UNBRACED AT TOP =40 PCF <br />WALL BRACED AT TOP -55 PCF <br />S. GUARDRAILMMDRAIL LOADING: <br />ALL GUARDRAIUHANDRAILS SHALL MEET 200 LBS (MINIMUM) CONCENTRATED FORCE APPLIED <br />IN ANY DIRECTION. IN -FILL COMPONENTS OF GUARDRAIL SHALL MEET 50 PSF. THESE LOADS <br />ARE TO BE EVALUATED INDEPENDENTLY AND ARE NOT TO ACT CONCURRENTLY WITH ANY <br />OTHER LIVE LOAD. DEFLECTION OF GUARDRAIL SHALL MEET THE CRITERIA SET FORTH BY THE <br />INTERNATIONAL CODE COUNCIL EVALUATION SERVICES (CC -ES) AC 273 -'ACCEPTANCE <br />CRITERIA FOR HANDRAILS AND GUARDS.' <br />FOUNDATION NOTES: <br />I. CONTRACTOR SHALL VERIFY ALL CONDITIONS, INCLUDING UNDERGROUND UTILITIES AND FIELD <br />MEASUREMENTS AT JOB SITE AND REPORT ANY DISCREPANCIES TO OWNER'S REPRESENTATIVE. <br />2. TOP OF SPREAD FOOTING ELEVATIONS NOTED ON PLAN ARE MINIMUM ELEVATIONS. IN ALL <br />-CASES FOOTINGS ARE TO BEAR ON UNDISTURBED NATURAL SOILS OR ENGINEERED FILL HAVING <br />A MINIMUM NET ALLOWABLE BEARING CAPACITY OF 2000 PSF. <br />3. SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING. <br />FOUNDATIONS POURED AGAINST THE EARTH REQUIRED THE FOLLOWING PRECAUTIONS: SLOPE <br />SIDES OF EXCAVATIONS AS APPROVED BY GEOTECHNICAL ENGINEER AND CLEAN UP <br />SLOUGHING BEFORE AND DURING CONCRETE PLACEMENT. PROVIDE 6 MIL (MINIMUM) <br />POLYETHYLENE VAPOR RETARDER AGAINST SOILS WHERE CONCRETE IS TO BE PLACED; LAP ALL <br />EDGES B INCH (MINIMUM) AND SEAL WITH ADHESIVE <br />4. WHERE FOOTING STEPS ARE NECESSARY, THEY SHALL BE NO STEEPER THAN ONE VERTICAL TO <br />TWO HORIZONTAL U.N.O. <br />S. FOOTINGS SHALL BE CENTERED UNDER COLUMNS AND WALLS UNLESS SPECIFICALLY DETAILED <br />OTHERWISE ON THE DRAWINGS. <br />S. NO FOOTINGS OR SLABS SHALL BE PLACED ON OR AGAINST SUB -GRADE CONTAINING FREE <br />WATER, FROST OR ICE. SHOULD WATER OR FROST, HOWEVER SLIGHT, ENTER A FOOTNG <br />EXCAVATION AFTER SU"RADE APPROVAL, THE SU"RADE SHALL BE REINSPECTED BY THE <br />GEOTECHNICAL ENGINEER# TESTING LABORATORY AFTER REMOVAL OF WATER OR FROST. <br />7. CONTRACTOR SHALL FURNISH ALL REQUIRED DE -WATERING EQUIPMENT TO MAINTAIN A DRY <br />EXCAVATION UNTIL BACKFILL IS COMPLETE <br />FOUNDATION NOTES (CONTINUED): <br />8. A GEOTECHNICAL ENGINEER REGISTERED IN THE STATE OF WORK PERFORMED SHALL INSPECT <br />THE CONDITION AND ASSURE THE ADEQUACY OF ALL SITE PREPARATION, SUBGRADES, FILLS, <br />BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS AND WALLS. HE SHALL <br />SUBMIT REPORT TO THE ARCHITECT/ENGINEER DESCRIBING HIS INVESTIGATIONS OF ANY <br />NON -CONFORMING WORK. <br />BACKFILLING: <br />1. DO NOT PLACE BACKFILL AGAINST FOUNDATION WALLS - DESIGNED AS SUPPORTED AT TOP AND <br />BOTTOM - UNTIL BASEMENT LEVEL AND FIRST FLOOR SYSTEM ARE IN PLACE SHORE AND/OR <br />BRACE WALLS AS REQUIRED IF BACKFIWING OPERATIONS ARE TO BE CARRIED OUT PRIOR TO <br />PLACEMENT OF FLOOR SYSTEM. <br />2. WHERE BACKFlLL IS TO BE PLACED ON BOTH SIDES OF FOUNDATION WALLS, PROVIDE A <br />BALANCED BACKFILL AGAINST FOUNDATION WALLS TO ELIMINATE LATERAL LOAD EFFECTS, OR <br />PROVIDE NECESSARY TEMPORARY LATERAL SUPPORT TO THE TOP OF THE WALL UNTIL <br />PERMANENT SUPPORT IS INSTALLED. <br />3. BACKFILL MATERIAL SHALL CONSIST OF CLEAN, WELL GRADE GRANULAR SOILS, FREE OF <br />ORGANIC MATERIAL AND BE COMPACTED TO 95% OF MAXIMUM DENSITY, AS DETERMINED BY <br />THE MODIFIED PROCTOR METHOD (ASTM D1557), IN LIFTS NOT EXCEEDING 8 INCHES. <br />CONCRETE NOTES: <br />1. STRUCTURAL CONCRETE HAS BEEN DESIGNED IN ACCORDANCE PER ACT 332'RESIDENTIAL <br />CODE REQUIREMENTS FOR STRUCTURAL CONCRETE'. <br />2. CONCRETE PRODUCTION AND PLACEMENT SHALL CONFORM TO THE REQUIREMENTS OF ACI 332 <br />'RESIDENTIAL CODE REQUIREMENTS FOR STRUCTURAL CONCRETE' EXCEPT AS MODIFIED BY <br />STRUCTURAL REQUIREMENTS NOTED ON THE DRAWINGS. <br />3. CEMENT SHALL CONFORM TO ASTM CI SO'SPECIFICATION FOR PORTLAND CEMENT.' CONCRETE <br />SHALL BE NORMAL WEIGHT, UNLESS INDICATED OTHERWISE. <br />4. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C33'SPECIFICATION FOR CONCRETE <br />AGGREGATES.' <br />5, REINFORCING SHALL CONFORM TO ASTM A-815 GRADE 80. <br />6. REINFORCEMENT SHALL BE FABRICATED AND ERECTED ACCORDING TO THE ACT STANDARDS: <br />'DETAILS AND DETAILING OF CONCRETE REINFORCEMENT, ACI 315 - AND WAMIAL OF <br />ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES', ACI 315R. <br />7. REINFORCING STEEL AND WELDED WIRE FABRIC SHALL BE PLACED WITH MINIMUM CONCRETE <br />COVER AND TOLERANCES AS FOLLOWS: <br />SLAB -ON -GRADE: WITHIN UPPER 2/3 OF SLAB AND 3/4' MNIMUM COVER AT INTERIOR <br />CONDITIONS; 1-1/2• MINIMUM COVER AT EXTERIOR CONDITIONS <br />CONCRETE (FOUNDATION) AGAINST EARTH: 3' <br />FORMED CONCRETE 1-1/2' (#5 REBAR OR SMALLER) Y (#6 REBAR OR LARGE;) <br />TOLERANCE: +/- 3/8' <br />8. REINFORCING STEEL SHALL NOT BE CUT, BENT OR STRAIGHTENED IN THE FIELD UNLESS <br />APPROVED BY THE STRUCTURAL ENGINEER OR AS INDICATED ON THE DRAWINGS. <br />9. WELDING OF REINFORCING STEEL IS PROHIBITED UNLESS SPECIFICALLY DETAILED. WELDING <br />WHERE DETAILED SHALL CONFORM TO AWS DI A SPECIFICATION. <br />10. CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH AS FOLLOWS: <br />FOUNDATIONS 8, FOUNDATION WALLS: 2500 PSI <br />SLAB -ON -GRADE S CONCRETE BEAMS: 25M PSI <br />I1.CONTRACTOR SHALL TIE REINFORCING STEEL SECURELY IN PUKE PRIOR TO PLACING <br />CONCRETE AND PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THEIR POSITION WITHIN <br />SPECIFIED TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES. INSERTING DOWELS INTO <br />WET CONCRETE IS NOT PERMITTED. ANCHOR RODS AND STEEL INSERTS SHALL BE SET BY <br />TEMPLATE TO WITHIN A 1/8' TOLERANCE IN ANY DIRECTION WITH MINIMUM EMBEDMENT AND <br />EXACT PROJECTION INDICATED ON THE DRAWINGS, PRIOR TO PLACING CONCRETE. <br />12.HOOKED BARS SHALL BE STANDARD 90 DEGREE HOOKS PER ACI UNLESS NOTED OTHERWISE ON <br />THE DRAWINGS. MINIMUM LAP SPLICE SHALL BE CLASS B PER ACI 31 S. LOCATION OF LAP <br />SPLICES SHALL BE AS INDICATED ON CONSTRUCTION DOCUMENTS. <br />13.130WELS INTO FOUNDATION SHALL MATCH SIZE AND SPACING OF VERTICAL REINFORCEMENT AT <br />ALL COLUMNS, PIERS AND WALLS, UNLESS OTHERWISE NOTED. <br />14-CONTRACTOR SHALL OBTAIN APPROVAL PRIOR TO PLACING OPENINGS OR SLEEVES NOT SHOWN <br />ON THE DRAWINGS, THROUGH ANY STRUCTURAL MEMBER. <br />15.ONE OF THE FOLLOWING CONCRETE SLAB ON GRADE CRACK CONTROL METHODS SHALL BE <br />USED (CONTRACTOR PREFERENCE): <br />• CONTROL JOINTS: SHALL BE FORMED, SAWED, OR TOOLED TO A 1' MINIMUM DEPTH WITHIN <br />24 HOURS OF CONCRETE PLACEMENT. MAXIMUM JOINT SPACING FOR UNREINFORCED SLAB <br />IS AS FOLLOWS: <br />3-1/2' SLAB: 8 FEET O.C. EACH DIRECTION <br />4' SLAB: 10 FEET O.C. EACH DIRECTION <br />• WELDED WIRE FABRIC (W.W.F.) 6XS.W1.4XW1.4. WELDED WIRE FABRIC SHALL BE FURNISHED IN <br />FLAT SHEETS (ROLLS NOT PERMITTED) AND SHALL CONFORM TO ASTM A-1054 AND HAVE A <br />MINIMUM SIDE AND END LAP OF 8 INCHES. <br />• MICRO- OR MACRO- SYNTHETIC FIBER REINFORCEMENT <br />FIBER LENGTHS SHALL BE 1 /2' TO 2-1/4" IN LENGTH. DOSAGE AMOUNT SHALL BE FROM 3/4 TO <br />3.0 POUNDS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SYNTHETIC <br />FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER/SUPPUER SHALL PROVIDE <br />CERTIFICATION OF COMPLIANCE WITH ASTM C1116 WHEN REQUESTED BY THE BUILDING <br />OFFICIAL <br />1S. CONTROL JOINTS SHALL BE FURNISHED WITH A FULL-LENGTH KEYWAY CENTERED ON MEMBERS. <br />WHERE THE SIZE OF KEY IS NOT SHOWN ON THE DRAWINGS, THE KEY SHALL BE 25% OF THE <br />CROSS-SECTION DIMENSION OF THE MEMBER AND MINIMUM 1.1/2INCHES INTO THE FIRST POUR <br />OF CONCRETE <br />17. PROVIDE POCKETS OR RECESSES IN CONCRETE WORK FOR COLUMNS AND BEAMS AS REQUIRED <br />EVEN IF NOT SHOWN ON THE DRAWINGS. PROVIDE CONCRETE FILL AFTER BEAM ERECTION. <br />18. CURING OF CONCRETE SURFACES SHALL CONFORM TO AC 308.1 'STANDARD SPECIFICATION <br />FOR CONCRETE CURING' AND ACI 30OR *GUIDE TO CURING CONCRETE'. <br />MASONRY NOTES: <br />1. CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 530,'BUILDING CODE <br />REQUIREMENTS FOR MASONRY STRUCTURES' AND SHALL BE CONSTRUCTED IN ACCORDANCE <br />WITH ACI 530.1, *SPECIFICATIONS FOR MASONRY STRUCTURES.' <br />2. CONCRETE MASONRY SHALL CONFORM TO ASTM C90 AND HAVE A MINIMUM COMPRESSIVE <br />STRENGTH PM - 1,15W PSI U.O.N. MASONRY SHALL HAVE A TEXTURE SUITABLE FOR STUCCO <br />APPLICATIONS WHERE ARCHITECTURAL DRAWINGS INDICATE STUCCO APPLICATION. <br />3. CONCRETE MASONRY UNITS SHALL BE LAID IN RUNNING BOND. <br />4. MORTAR FOR ALL MASONRY SHALL CONFORM TO ASTM C270 WITH MINIMUM COMPRESSIVE <br />STRENGTH OF 2,000 PSI. MORTAR BELOW GRADE SHALL BE TYPE M. ELSEWHERE MORTAR MAY <br />BE ETHER TYPE M OR S UNLESS SPECIFICALLY INDICATED OTHERWISE USE EITHER PORTLAND <br />CEMENTNME OR MASONRY CEMENT FOR MORTAR. <br />S. GROUT SHALL CONFORM TO ASTM 0476 WITH MINIMUM 28-DAY COMPRESSIVE STRENGTH OF <br />2.500 PSI. <br />6. STEEL BAR REINFORCEMENT SHALL CONFORM TO ASTM AST 5, GRADE S0. <br />7. VERTICAL CELLS CONTAINING REINFORCING AND GROUT SHALL FORM A CONTINUOUS CAVITY, <br />FREE OF MORTAR DROPPINGS. <br />S. VERTICAL CMU WALL REINFORCING SHALL BE AS NOTED ON THE DRAWINGS. DOWELS TO <br />CONCRETE FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL REINFORCING UNLESS <br />NOTED OTHERWISE. REINFORCE CMU CORE AT CORNERS, EACH SIDE OF CONTROL JOINTS AND <br />EACH SIDE OF WALL OPENINGS WITH (1)-" CONTINUOUS VERTICAL REINFORCING BARS. <br />MASONRY NOTES (CONTINUED): <br />9. HORIZONTAL BOND BEAM AND VERTICAL REINFORCING SHALL BE CONTINUOUS U.O.N. LAP <br />SPLICE REINFORCING PER THE SCHEDULE OR USE MECHANICAL SPLICES ADEQUATE FOR 125% <br />OF SPECIFIED YIELD STRENGTH OF THE BAR. LAP VERTICAL REINFORCEMENT WITH MINIMUM <br />DOWELS OF SAME SIZE AND SPACING THAT HAVE BEEN PREVIOUSLY INSTALLED IN THE <br />FOUNDATIONS. DOWEL EMBEDMENT IN CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF <br />THE CONCRETE NOTES. <br />BAR SIZE <br />LAP SPICE LENGTH <br />BEND DIAMETER <br />ACI HOOK <br />04 <br />2W <br />3' <br />1w <br />#5 <br />25' <br />33/4' <br />Ur <br />#6 <br />34• <br />4-1/2' <br />11' <br />#7 <br />5 <br />13' <br />10.REINFORCING BARS SHALL BE HELD IN POSITION BY WIRE TIES OR OTHER APPROVED MEANS TO <br />ENSURE DESIGN LOCATION AND LAP. PLACE BARS AND LAP PRIOR TO GROUTING. <br />11. GROUTING OF MASONRY WALLS SHALL CONFORM TO RECOMMENDED PROCEDURE FOR YAW <br />UFT GROUTING' OR "HIGH LIFT GROUTING' AS OUTLINED IN THE NCMA-TEK 3-2A - GROUTING <br />FOR CONCRETE MASONRY WALLS AND ACT 530/ASCE 5 SPECIFICATION FOR MASONRY <br />STRUCTURES. GROUT LIFTS SHALL NOT EXCEED 5 FEET WITHOUT MECHANICALLY <br />CONSOUDATED (VIBRATED) GROUT POURS. <br />I ZUFTS OF GROUT SHALL L BE KEYED 4 INCHES INTO THE PREVIOUS COURSE OF MASONRY BELOW. <br />13.MASONRY BELOW GRADE SHALL BE GROUTED SOUD. <br />14. CONTRACTOR SHALL BRACE MASONRY WALLS TO RESIST WIND LOADS UNTIL FLOORS AND <br />ROOFS ARE IN PLACE, AND THE MASONRY HAS REACHED 75% OF THE REQUIRED STRENGTH PM. <br />BRACING SHALL BE PROVIDED IN ACCORDANCE WITH OSHA - CONSTRUCTION SAFETY <br />STANDARDS FOR MASONRY WALL BRACING AND NCMA TEK 3-48 -'BRACING CONCRETE <br />MASONRY WALLS DURING CONSTRUCTION.' <br />WOOD FRAMING NOTES: <br />1. STRUCTURAL SAWN LUMBER, STRUCTURAL COMPOSITE LUMBER, AND CONNECTIONS HAVE <br />BEEN DESIGNED IN ACCORDANCE WITH THE'NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION.- (NDS) <br />2. PLYWOOD HAS BEEN DESIGNED IN ACCORDANCE WITH 'PANEL DESIGN SPECIFICATION.' AND <br />SHALL CONFORM TO'VOLUNTARY PRODUCT STANDARD PSI CONSTRUCTION AND INDUSTRIAL <br />PLYWOOD.' <br />3. ORIENTED STRAND BOARD (OSB) SHALL CONFORM TO 'VOLUNTARY PRODUCT STANDARD P82 <br />PERFORMANCE STANDARD FOR WOOD -BASED STRUCTURAL -USE PANELS'. <br />4. ALL BEAMS AND HEADERS SHALL BE (2) PLY U.N.O. <br />5. WOOD SILL PLATES AND WOOD WADS SUPPORTED ON CONTINUOUS CONCRETE OR MASONRY <br />SHALL BE ANCHORED WITH 1/2' DIAMETER CAST4N-PLACE ANCHOR BOLTS WITH 7' EMBEDMENT, <br />4- (MINIMUM) AND 12- (MINIMUM) FROM END OF SILL PLATE(S), LOCATED WITHIN THE MIDDLE <br />THIRD OF THE SILL PLATE, WITH NUT AND 3•x3'A.229- WASHERS AT THE ANCHOR SPACING <br />BELOW: <br />MAXIMUM ANCHOR BOLT SPACING = 2-0.O.C. <br />REFER TO'PRE-APPROVED FIELD REPAIR NOTES' SECTION FOR ALTERNATE ANCHORAGE <br />APPROVALS. FOR OTHER ANCHORS NOT LISTED, SUBMIT TO ENGINEER OR RECORD FOR <br />RENEW. <br />S. ALL LUMBER IN CONTACT WITH EARTH, CONCRETE, OR MASONRY - AND WOOD BEAMS <br />POCKETING INTO CONCRETE OR MASONRY WALLS HAVING CLEARANCES LESS THAN 1/2' ON <br />TOP, SIDES, AND END(S) SHALL BE PRESSURE TREATED OR SEPARATED WITH AN IMPERVIOUS <br />MOISTURE BARRIER. <br />7. STRUCTURAL SAWN LUMBER SHALL BE SPRUCE -PINE -FIR 140.1 /NO.2 OR BETTER U.N.O. WITH <br />BASE DESIGN VALUES: <br />N- 875 PSI F- 425 PSI FT = 45O PSI FC- 1150 PSI FV- 135 PSI E= 140O KSI <br />WITH THE MOISTIdRE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%. <br />S. BEARING AND EXTERIOR WALL STUDS SHALL BE CAPPED WITH DOUBLE (2X) TOP PLATES <br />INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT INTERSECTIONS. END JOINTS IN <br />DOUBLE (2X) TOP PLATES SHALL BE OFFSET AT LEAST 24 INCHES AND SHALL BE NAILED WITH <br />NOT LESS THAN (8)-0.162-x2.1/2' FACE NAILS ON EACH SIDE THE JOINT. DOUBLE (2)) TOP PLATES <br />OF EXTERIOR WADS AND INTERIOR LOAD BEARING WALLS SHOWN ON DRAWINGS SHALL BE <br />SOUTHERN YELLOW PINE NO.2 OR BETTER WITH BASE DESIGN VALUES: <br />FB= 110D PSI F = 565 PSI FT= 675 PSI FC= 1450 PSI Fy= 175 PSI E= 1400 KSI <br />WITH THE MOISTUR% CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%. <br />9. STRUCTURAL COMPOSITE LUMBER SHALL CONFORM TO ASTM D 5456 WITH THE FOLLOWING <br />ALLOWABLE DESIGN STRESSES <br />MICROLAM LVL PARALLAM PSL TIMBERST RAND LSL <br />E - 2000 KSI E = 1 SW KSI E 1300 KSI <br />Fa = 2000 PSI N = 2400 PSI Fe = 1700 PSI <br />10. FLOOR SHEATHING SHALL BE 23/32 INCH, APA RATED SHEATHING, 48/24 MIN., EXPOSURE 1. <br />INSTALL WITH THE LONG DIMENSION OR STRENGTH AXIS OF THE PANEL ACROSS SUPPORTS <br />AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. PANEL EDGES SHALL BE <br />TONGUE -AND -GROOVE. FLOOR SHEATHING SHALL BE GLUED AND NAILED TO SUPPORTING <br />MEMBERS. ADHESIVE SHALL MEET APA SPECIFICATION AFG.01, APPLIED IN ACCORDANCE WITH <br />THE MANUFACTURERS RECOMMENDATIONS. PROVIDE 0.1 31'x2-1/2'COMMON NAILS AT 6 INCH <br />O.0 ALONG SUPPORTED PANEL EDGES AND 12 INCH O.0 AT INTERMEDIATE SUPPORTS. <br />11.FOR INTERIOR WALL HEADERS PROVIDE (1)-2X JACK STUD AND (1)-2X KING STUD U.N.O. ON <br />DRAWINGS. <br />12.FOR EXTERIOR WALL HEADERS PROVIDE JACK STUD AND KING STUD PER CHART BELOW U.N.O <br />ON DRAWINGS: <br />WINDSPEED OF <br /><- 140 EXP. C <br />WAIL HEIGHT <br />SIFT <br />9FT <br />LOFT <br />STUD <br />SIZE <br />HEADER SPAN <br />(FT) <br />4 <br />1J/1K <br />1J/1K <br />1J/1K <br />6 <br />1J/IK <br />1J/1K <br />1J/2K <br />8 <br />11J/1K <br />1J/2K <br />1J/3K <br />2x4 <br />10 <br />1J/2K <br />1J/2K <br />1JAK <br />12 <br />1J/2K <br />1J/3K <br />1J/4K <br />14 <br />1J/2K <br />1JAK <br />ENG <br />16 <br />1J/3K <br />1J/4K <br />ENG <br />18 <br />1J/31( <br />ENG <br />ENG <br />WNDSPEED OF <br /><- 140 EXP. C <br />WAIL HEIGHT <br />SIFT <br />OFT <br />10FT <br />STUD <br />SIZE <br />HEADER SPIN <br />iFn <br />4 <br />1J/IK <br />1J/1K <br />INIK <br />6 <br />IJ/1K <br />1J/1K <br />INIK <br />8 <br />1J/1K <br />1JfIK <br />INIK <br />10 <br />1J/1K <br />1JAK <br />INIK <br />2x6 <br />12 <br />INIK <br />1J/1K <br />1J1IK <br />14 <br />1J/1K <br />1J/1K <br />1J1IK <br />16 <br />1J/1K <br />1J/1K <br />1J/Z <br />18 <br />111K <br />1JMK <br />T~ <br />I & WALLS SHOWN ON THE FRAMING PLANS ARE LOAD BEARING WALLS; WALLS NOT SHOWN ON <br />STRUCTURAL FRAMING PLANS ARE INTERIOR NON -LOADING BEARING PARTITION WALLS. <br />14.LOAD BEARING WALLS SHALL BE CONSTRUCTED WITH 2X STUDS AT IW O.C. MAXIMUM U.N.O. <br />NON -LOAD BEARING PARTITION WALLS SHALL BE CONSTRUCTED WITH 2X OR METAL STUDS (18 <br />GA MIN.) ® 24- O.C. MAXIMUM. <br />IS. STUD COLUMNS UNDER LOAD BEARING POINTS OF GIRDERSSEAMS SHALL MATCH THE <br />GIRDER/BEAM PLY COUNT WITHIN 1/2' TOLERANCE P-PLY STUD COLUMN MINIMUM). SOLD <br />BLOCK ALL GIRDERIBEAMS THRU FLOOR SYSTEMS AND TO THE FOUNDATION. <br />16. WHEN NOT SHOWN ON DRAWINGS OR DETAILS, THE NAILING SCHEDULE FOR WOOD FRAMING <br />ELEMENTS SHALL COMPLY WITH THE IRC TABLE R802.3(i). <br />17.FLOOR SYSTEMS ARE DESIGNED BY THE TRUSS AND/OR WOOD I- JOIST MANUFACTURER. <br />INSTALL PER MANUFACTURER'S RECOMMENDATIONS, NOTES, AND DETAILS. FLOOR FRAMING <br />CONCEPT LAYOUTS SHOWN WITHIN THE DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY TO <br />DEPICT FLOOR SYSTEM -TO -WALL CONNECTIONS. CHANGES TO THE CONCEPTUAL FLOOR <br />LAYOUT SHOWN IS NOT PERMITTED WITHOUT A LETTER AND REVIEW FROM THE ENGINEER OF <br />RECORD. PREFABRICATED WOOD hIOIST SHALL CONFORM TO ASTM D 5055. <br />PRE-ENGINEERED ROOF TRUSS NOTES: <br />1. ROOF TRUSS SHOWN ON STRUCTURAL DRAWINGS IN CONCEPTUAL ONLY TO ILLUSTRATE <br />TRUSS -TO WALL CONNECTIONS AND DOES NOT SERVE AS A ROOF TRUSS DESIGN. ROOF <br />TRUSSES SHALL BE DESIGNED AND MANUFACTURED IN CONFORMANCE FOR THE INDICATED <br />LOADS WITH ANSI/TP11 'NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD <br />TRUSS CONSTRUCTION.' FINAL PRE-ENGINEERED ROOF TRUSS FRAMING LAYOUT AND DESIGNS <br />TO BE BY ROOF MANUFACTURERS DELEGATED ENGINEER. <br />2. ROOF TRUSSES SHALL BE DESIGNED FOR THE SUPERIMPOSED LOADS IDENTIFIED IN THE <br />DESIGN CRITERIA NOTES SECTION. <br />3. FOR PLANS FIELDSTONE AE IS NOT CONTRACTED TO PERFORM TRUSS REVIEW ON, THE <br />CONTRACTOR IS RESPONSIBLE TO ASSURE THE DIRECT COMPUANCE OF TRUSS <br />MANUFACTURER LAYOUT TO THESE DRAWINGS S, VERIFY ALL TRUSS CONNECTORS ARE <br />SUFFICIENT TO WITHSTAND THE UPUFTAATERAL LOADS IMPOSED <br />4. TRUSS MANUFACTURER SHALL PROVIDE HANGERS AND CONNECTIONS ADEQUATE FOR LOADS <br />AT ALL TRUSS -TO -TRUSS, TRUSS -TO -BEAM, AND BEAM -TO -TRUSS CONNECTIONS. IF ANY TRUSS <br />CONNECTOR SHOWN IN THESE DRAWINGS CAPACITY HAS BEEN EXCEEDED, THE TRUSS <br />MANUFACTURER SHALL NOTIFY THE ENGINEER OF RECORD IMMEDIATELY. <br />5. REFER TO ARCHITECTURAL DRAWINGS FOR TRUSS SHAPE, OVERHANG, DIMENSIONS, SLOPES, <br />SPANS, DRAINAGE, BEARING WALL HEIGHTS, ETC. <br />S. THE POSITIONS, WEIGHTS, AND METHODS OF ATTACHMENTS OF ALL MECHANICAL UNITS, <br />ELECTRICAL FIXTURES, PLUMBING, FIRE SPRINKLERS, ETC SHALL BE INCLUDED IN THE DESIGN <br />OF THE TRUSSES BY THE TRUSS MANUFACTURER. SEE ARCHITECTURAL DRAWINGS FOR ATTIC <br />ACCESS SI2E AND LOCATIONS. <br />7. SUPERIMPOSED LOADS FROM SECONDARY FRAMING Q.E. SOFFITS, PARAPETS, VALLEY FRAMING, <br />UPPER TRUSSES, ETC) SHALL BE INCLUDED IN THE DESIGN OF SUPPORTING TRUSSES. <br />S. CONTRACTOR TO PROVIDE TRUSS BRACING PER SCSI.83IN ADDITION TO PERMANENT BRACING <br />SHOWN ON THE TRUSS DESIGN PROVIDED BY THE DELEGATED TRUSS ENGINEER. <br />PRE -APPROVED FIELD REPAIR NOTES: <br />1. MISPLACED DOWEL REPAIR: THIS NOTE DESCRIBES ALTERNATES TO MITIGATE THE CASTING OF <br />REBAR VERTICAL REINFORCMENT AT AN INCORRECT LOCATION. <br />IF THE WALL HAS NOT BEEN BUILT: DRILL AND EPDXY #5 REBAR (36- LG.) INTO THE THICKENED <br />EDGE OF SLAB AT THE CORRECT LOCATION. AS WALL IN CONSTRUCTED, LAP REBAR N <br />ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 12- LAP AT <br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAMIBONO BEAM. COMPLETE <br />GROUTING OF WALL <br />IF THE WALL HAS ALREADY BEEN BUILT: PRIOR TO GROUT PLACEMENT, OPEN THE WALL AT THE <br />CORRECT LOCATION APPROXIMATELY 16• IN) x 4' (W) AT FLOOR LEVEL DRILL AND EPDXY #5 <br />REBAR (32- LG.) INTO THE THICKENED EDGE OF SLAB. LAP VERTICAL REINFORCEMENT IN <br />ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 12• LAP AT <br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAWBOND BEAM. COMPLETE <br />GROUTING OF WALL <br />2. MISSING/MISPLACED ANCHOR SOLT: SILL PLATE ANCHORAGE SOLUTIONS <br />INTO CONCRETE: <br />A 1r2PxS' TITEN HD WITH 13/4' MINIMUM EDGE DISTANCE AND 8' MINIMUM END DISTANCE IS A <br />DIRECT 1:1 REPLACEMENT FOR A 1/2' DIAMETER ANCHOR BOLT WITH T EMBEDMENT INTO <br />CONCRETE <br />A 1/Y THREADED ROD SET-XP EPDXY T EMBEDMENT WITH 13/4' MINIMUM EDGE DISTANCE AND <br />7-1/Y MINIMUM END DISTANCE IS A DIRECT 1:1 REPLACEMENT FOR A 1/2' DIAMETER ANCHOR <br />BOLT WITH T EMBEDMENT INTO CONCRETE <br />INTO GROUT FILLED MASONRY (GFCMU): <br />A 1/Yh8' TITEN HO WITH 13/4• MINIMUM EDGE DISTANCE AND 8' MINIMUM END DISTANCE AT W-S" <br />O.C. REPLACES A 1/2' DIAMETER ANCHOR BOLT WITH 7' EMBEDMENT AT V-0' O.C.; LIKEWISE A <br />1/2'x8' TITEN HD WITH 13/4' MINIMUM EDGE DISTANCE AND 8' MINIMUM END DISTANCE AT 2'3' <br />O.C. REPLACES A I Ir DIAMETER ANCHOR BOLT WITH 7- EMBEDMENT ATV-0- O.C.. <br />3. MISSING/MISPLACED TRUSS STRAP ANCHOR: REFER TO 'MISSED TRUSS STRAP REPAIR' DETAIL <br />WITHIN DRAWINGS. <br />FOR MISLOCATED TRUSS ANCHORS WHICH ARE GREATER THAN 1/8' BUT LESS THAN 1-1/2' FROM <br />THE FACE OF THE TRUSS, A SHIM SHALL BE PROVIDED AND NAIL LENGTH INCREASED TO <br />PENETRATE THROUGH BOTH PLYS OF MATERIAL (I.E. 3- LG. NAILS). WHEN GAP IS GREATER THAN <br />1-1/2', INSTALL NEW ANCHORS. <br />4. MASONRY WALL OVERHANGING SLAB <br />BLOCK OVERHANG REPAIR <br />< 5/9' NO REPAIR REO'D <br />5/8' < OVERHANG < 1-1/2' GROUT SOLID BOTTOM 3 COURSES OF AFFECTED WALL LENGTH <br />>1.1/2' CONTACT ENGINEER OF RECORD FOR REPAIR <br />S. NOTCHED TOP PLATES 8 STUDS REQUIRING REPAIR <br />AT STUDS: STRUCTURAL REPAIR IS REQUIRED AT STUDS WHEN A STUD IS NOTCHED TO A DEPTH <br />GREATER THAN 25% OF THE WIDTH IN BEARING WALLS, OR 40% IN NON -LOAD BEARING WALLS; <br />OR WHEN A HOLE IS DRILLED/BORED TO A DIAMETER EXCEEDING 40% OF THE STUD WIDTH IN <br />BEARING WALLS, OR SD%OF THE STUD WIDTH IN NON -BEARING WALLS. IF THE MAXIMUM <br />HOLEINOTCH SPECIFICATIONS ARE EXCEEDED THEN A STUD SHOE MUST BE INSTALLED. STUD <br />SHOE REPAIRS ARE AS FOLLOWS: FOR 2X STUD USE HSS2-SDS1.5 WITH (12)-1/4'Xt-1/2" SDS <br />SCREWS. FOR MULTI -PLY 2X STUDS USE HSS2--#'-SOS3 WITH (12)-1 /4')W BOB SCREWS, WHERE <br />'#' CORRESPONDS TO THE NUMBER OF STUDS IN THE MULTI -PLY. <br />AT TOP PLATES. A HOLE, CUT, OR NOTCH THAT IS GREATER THAN 50% OF THE PLATE WIDTH IS <br />REMOVED FOR PIPING (EXCEPT WHEN THE SIDE OF THE WALL WITH THE NOTCH OR CUT IS <br />COVERED BY WOOD STRUCTURAL PANEL SHEATHING), OR THE PLATES ARE CUT THROUGH. THE <br />REQUIRED REPAIR IS A GALVANIZED 16-GAUGE METAL TIE THAT IS AT LEAST 1-1/2' WIDE AND <br />MUST BE FASTENED WITH (8)-1 SO NAILS ON EACH SIDE OF THE OPENING. <br />JURISDICTION SPECIFIC NOTES: <br />1. FOR PARTIALLY ENCLOSED AREAS, INCLUDING BUT NOT LIMITED TO LANAIS, PORCHES, AND <br />BALCONIES A 1/Y (MINIMUM) EXTERIOR GRADE SOFFIT BOARD WITH A CEMEWM04JS <br />KNOCKDOWN FINISH IS ACCEPTABLE PROVIDED THAT IT IS PAINTED MEETING THE <br />REQUIREMENTS OF ASTM C932 TO GIVE THE CEILING WATER RESISTANCE THE SOFFIT BOARD <br />PRODUCT SHALL BE ATTACHED PER MANUFACTURER SPECIFICATIONS TO BE IN COMPLIANCE <br />WITH R703.1. <br />2. THE SOFFIT DESIGN PRESSURE IS AS NOTED IN THESE DOCUMENTS. WITH KAYCAR VINYL SOFFIT <br />INSTALLED IN ACCORDANCE WITH MANUFACTURERS REQURRMENTS AND ]CC -ES EVALUATION <br />REPORT ESR-1495 THE SOFFIT WILL COMPLY WITH R703.1. <br />� <br />`�111111111/// <br />Fieldstone �pMIOf <br />C.O.A.# ARCHITECURE: <br />AA26002802 <br />C.O.E.# ENGINEERING: No. <br />29349- <br />O IBRAHEM ELAYEB, PE <br />P.E.# 91476 <br />■ BENJAMIN NIESE, PE % O STATE OF <br />P.E.# 86025 i����� '•��OR1D0! • <br />02/12/2024 <br />DATE ���11111111��` <br />:. <br />1�jE `ih- <br />ia <br />e2yts <br />�oyEB�"sg�8��aa <br />a551frr,E i$5505 <br />�Qh! P; <br />Michigan <br />3400 Auburn Rd <br />Suite 200 <br />Auburn Hills, MI 48326 <br />+1 248.622.4035 <br />Florida <br />12906 Tampa Oaks Blvd. <br />Suite 150 <br />Tampa, FL 33637 <br />+1 813.466.3310 <br />www. fieldstonese. corn <br />N <br />W U) <br />Z <br />go <br />CC <br />-I <br />Q O <br />y� QQ <br />r J <br />�2 <br />} <br />2 <br />a, a <br />V) N <br />DRAWN BY: I FAE <br />VERSION, 5.0 <br />SHEET NAME <br />COVER SHEET <br />SHEET # <br />SO. 1 -1 40 <br />