} <br />BUILDING DATA: <br />CONDITIONED OFFICE SPACE 3500 /100 = 35 PEOPLE <br />HAZARDOUS <br />WAREHOUSE SPACE 6500 / 500 = 13 PEOPLE <br />HAZARDOUS <br />CONDITION MEZZANINE <br />STORAGE SPACE <br />NON HAZARDOUS <br />CONDITION MEZZANINE <br />STORAGE SPACE <br />COVERED ENTRY <br />TOTAL AREA <br />TOTAL OCCUPANCY <br />3100 / 500 = 6 PEOPLE <br />3500 / 500 = 7 PEOPLE <br />208 N/A <br />16808 SQ. FT. <br />61 PEOPLE <br />OCCUPANCY CLASSIFICATION: MIXED BUSINESS OFFICE GROUP B <br />HIGH HAZARD GROUP H-3 <br />CONSTRUCTION TYPE: VB <br />FIRE PROTECTION: SPINKLED BUILDING <br />OWNER TO PROVIDE MSD SHEETS FOR FIRE SPRINKLER CO <br />PLUMBING FIXTURES EXCEED REQUIREMENT PER TABLE <br />403.1 FLORIDA BUILDING CODE 2017 6TH EDITION PLUMBING <br />GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2017 FLORIDA BUILDING CODE <br />6TH EDITION AND THE 2014 FLORIDA BUILDING CODE <br />ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY; HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN <br />OF THIS STRUCTURE. <br />THE BUILDING ( INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS: <br />FLOORS: SLAB: <br />LIVE LOAD - 40 P.S.F. LIVE LOAD - 50 P.S.F. <br />DEAD LOAD - 10 P.S.F. DEAD LOAD - 10 P.S.F. <br />ROOF: <br />LIVE LOAD - 20 P.S.F. <br />DEAD LOAD - 10 P.S.F. <br />WIND: <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 7-10, CHAPTERS 26 THRU 31; PER 2017 FLORIDA <br />BUILDING CODE 6TH EDITION SECTION 1609.1.1. <br />WIND DESIGN ASSUMPTIONS: <br />BUILDING EXPOSURE - B <br />BUILDING RISK CATEGORY - II <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT & EXPOSURE ADJUSTMENT <br />COEFFICIENT = 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT = +/- 0.18 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />ALL STRUCTURAL ELEMENTS, EXTERIOR <br />WALLS AND INTERIOR WALLS SHALL BE <br />TYPE V CONSTRUCTION PER FBC 602.5 <br />SOIL BEARING & COMPACTION: <br />COMPONENT & CLADDING WIND LOADS <br />ALL OTHERCOMPONENT <br />BUILDING <br />ROOF OVERHANG <br />ZONE <br />LOADS <br />LOADS <br />1 <br />N/A <br />+32.3/-35.3 <br />2 <br />-65.7 <br />+32.3/56.2 <br />3 <br />-110.6 <br />+32.3/-89.0 <br />4 <br />N/A <br />+35.3/-36.2 <br />5 <br />N/A <br />+35.3/-47.2 <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F. <br />(MINIMUM . THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED & COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. <br />FOUNDATION LOADING. <br />ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY; DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />NOR PERFORMING ANY SOIL TESTING_ <br />ARKAY ENGINEERING, INC. SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT <br />THE BUILDING LOADS. <br />FOUNDATIONS & SLAB -ON -GRADE: <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY <br />COMPACTED AND TERMITE POISONED SOIL. <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 26 DAY <br />COMPRESSIVE STRENGTH OF 2,500 P.S.I. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR #5 REBAR, 30" FOR #6 REBAR & 35" FOR #7 REBAR. <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES ( AFTER <br />FINAL SITE GRADING) . THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS <br />MASONRY WALLS: <br />CONCRETE MASONRY UNITS SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-90 <br />AND SHALL HAVE A MINIMUM PM OF 1,500 P.S.I. <br />MORTAR SHALL CONFORM TO ASTM C-270 AND SHALL BE EITHER TYPE M OR S. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR #5 REBAR, 30" FOR #6 REBAR & 35" FOR #7 REBAR. <br />GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE <br />OF 3W, PLACED AT AN 6 TO 11 INCH SLUMP AND HAVE A MINIMUM 26 DAY COMPRESSIVE STRENGTH <br />OF 2,500 P.S.I. ( WHEN TESTED PERASTM C-1019) . <br />PROVIDE CLEAN -OUT OPENINGS (12 SQ. IN) N CELLS CONTAINING SPLICED REINFORCEMENT, WHEN <br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT. <br />SOIL TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE <br />SHALL STATE <br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." <br />IF A REGISTERED TERMi T ICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />ABOVE DO NOT APPLY. A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE <br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR 10 THE SLAB POUR. THE SYSTEM <br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL_ <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />BACKFILLING & COMPACTION ARE COMPLETE <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE %-TREAI ED <br />( INCLUDING ANY BOXED OR FORMED AREAS) - <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE & DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT. <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />SHALL BE REQUIRED <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TC EXTERIOR SOIL TREATMENT <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) . ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE TREATED. <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />BUILDING SIDEWALLS <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5/6 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />SAFETY GLAZING: <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL- SECTION R306: <br />(1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR <br />ASSEMBLIES. <br />(Z GLAZING INDOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN 60 INCHES ABOVE THE DRAIN INLET. <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT. <br />B) BOTTOM EDGE LESS THAN 16 INCHES ABOVE THE FLOOR. <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />PLANE OF THE GLAZING. <br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308 FOR ADDITIONAL AREAS <br />THAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING. <br />PACKAGING FACILITY FOR <br />PROFESSIONAL HAIR LAB <br />CORNER OF TRUMP PLACE AND CORREIA DR. <br />ZEPHYRHILLS, FLORIDA <br />LOCATION MAP <br />PLAN TO COMPLY WITH FLORIDA FIRE PREVENTION CODE 6TH EDITION <br />CONTRACTOR PROVIDE SIGN DESIGNATING IF FRAME CONSTRUCTION ROOF <br />CONTRACTOR TO PROVIDE TACTILE SIGNS AS REQUIRED <br />INTERIOR FINISHES <br />TABLE 803.11 <br />INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY" <br />SPRtNKLERED' <br />NONSPRINKLERED <br />GROUP <br />Interior exit stairways and ramps <br />Corridors and <br />enclosure for exit <br />Rooms and <br />Interior it stairways and <br />Corridors and <br />enclosure for exit <br />Rooms and <br />and exit passageways' <br />access stairways <br />enclosed <br />spaces` <br />ramps and exit <br />passageways" <br />access stairways <br />enclosed <br />spaces` <br />and ramps <br />and ramps <br />4 I& .4 2 <br />_ B <br />B <br />C <br />A <br />Ad <br />B` <br />B.FMRI <br />B <br />C <br />C <br />q........... <br />B <br />! C <br />--- <br />— <br />H <br />B <br />P <br />C- <br />A <br />A <br />B <br />_ <br />S- <br />I2 <br />B <br />B <br />Bh' <br />A <br />A <br />B <br />I-3 <br />A <br />A' <br />C <br />A <br />A <br />B <br />I-4 <br />B <br />B <br />B- <br />A <br />A <br />B <br />C <br />R-3 <br />C <br />C <br />C <br />C <br />C <br />C <br />_ <br />S <br />.w <br />C C C <br />..._ <br />B B C <br />C:= <br />No restrictions <br />N(� restrictions <br />For SI: I inch = : 5.4 ntm, 1 square foot = 0.0929mz, <br />a. glass C interior finish materials shall be permitted for wainscotting ur paneling of not more than 1,000 square feet of applied surface area in the grade lobby <br />where applied directly to a noncombustible base or over furring strips applied to a noncombustible b ase and fireblocked as required by Section 803.13.1. <br />b. In other than Group I-3 occupancies in buildings less than three stories above grade plane, Class B interior 5ni h for nonsprinklered buildings and Class C <br />interior finish for sprinklered buildings shalt be permitted in imenor exit st,,urways and ramps, <br />c. Requirements for rooms and enclosed spaces shall be based upon spaces enclosed by partitions. Where a fire -resistance rating is required for structural <br />elements, the enclosing pau-dtions shall extend from the floor to the ceiling. Partitions that do not comply with this shall be considered enclosing spaces and the <br />rooms or spaces on both sides shall be cons4cied one. In determining the applicable requirements for rooms and enclosed spaces, the specific occupancy <br />thereof shall be the governing factor regardless of the group classification of the building or structure. <br />d. Lobbv areas in Group A- 1, A-2 and A-3 occupancies shall not be less than Class B materials. <br />e. Class C interior finish materials shall be permitter) in places of assembly with an occupant load of +00 persons or less. <br />f. For places of religious worship, mood used for ornamental purposes, trusses, paneling of Chancel furnishing shall be pec'4titted. <br />g. Class B material is required where the building exceeds two stories. <br />h. Class C interior finish materials shall be perritted in administrative spaces. <br />i. Class C interior finish materia's shall he permitted in rooms with a capacity of four persons or less. <br />j. Class B materials shall be permitted as wainscotting extending not more lion 48 inches above the finished flour in corridors and exit access stairways and <br />ramps. <br />k. Finish materials as provided for in other sections of this code. <br />i. Applies when protected by an antom2tic sprinkler system insfnfled in accordance with Section 9t)33.1. i or 903.31.2. <br />RESTROOM FINISH NOTE: <br />WALLS: TO HAVE A SMOOTH NON ABSORBENT MATERIAL <br />MINIMUM 46" ABOVE FINISH FLOOR <br />FLOORS: TO HAVE A SMOOTH NON ABSORBENT MATERIAL <br />w <br />SITE LOCATION <br />>Fi 11.D11Nia Q Y� L <br />PLAN INDEX: <br />SITE PLAN BY OTHERS <br />FIRE SPRINKLER PLAN BY OTHERS <br />SHEET B 1: MAIN LEVEL FLOOR PLAN <br />EXTERIOR DOOR AND WINDOW SCHEDULE <br />INTERIOR DOOR AND WINDOW SCHEDULE <br />INTERIOR BOX BEAM DETAIL <br />INTERIOR STEEL STUD WALL DETAIL <br />SHEET B 2: MEZZANINE FLOOR PLAN <br />SHEET B 3: EXTERIOR ELEVATIONS <br />SHEET B 4: BUILDING CUT SECTION "A" <br />BUILDING CUT SECTION "B" <br />SHEET B 5: FOUNDATION PLAN <br />FOOTING AND PAD DETAIL <br />SHEET B 6: ENGINEERED FLOOR TRUSS PLAN <br />WAREHOUSE STAIR DETAIL SECTION <br />ENTRY S-1 DETAIL <br />SHEET B 7: FIRE WALL DETAIL <br />SHEET M 1: MAIN LEVEL HVAC PLAN <br />MEZZANINE HVAC PLAN <br />SHEET M 2: HVAC SPECIFICATIONS <br />HVAC DETAILS <br />SHEET E 1: ELECTRICAL DRAWINGS <br />SHEET E 2: ELECTRICAL DRAWINGS <br />SHEET E 3: ELECTRICAL DRAWINGS <br />SHEET E 4: ELECTRICAL DRAWINGS <br />SHEET LS: LIFE SAFETY PLAN <br />SHEET P 1: PLUMBING FIXTURE LOCATION PLAN <br />SANITARY DRAIN LINE PLAN <br />SHEET P 2: COLD WATER RISER DIAGRAM <br />HOT WATER RISER DIAGRAM <br />SANITARY RISER DIAGRAM <br />ADA FIXTURE DETAILS <br />PLUMBING SCHEDULE <br />HANSON & HEADLEY <br />PROFESSIONAL ENGINEERS <br />ENGINEERING BUSINESS NO. EB6450 ARKAY ENGINEERING INC. <br />structural en ineere <br />PO BOX 1728 5290 S. ROMANS AVE. g <br />DADE CITY, FL 33526 INVERNESS, FL 34452 1958 E. Edgewood Drive, Lakeland FI 33803 <br />(352) 521-5848 (352) 726-2332 <br />r phone 863-688-6500 Fax 863-ASS-fo��Z <br />State of Florida Certificate of Authorization M EB6341 <br />Richard L Kiddey P.E. - Florida Licenee • 31296 <br />ARKAYO 17915 <br />