GENERAL STRUCTURAL NOTES: <br />1. ALL WORK SHALL CONFORM TO THE 2023 SM EDITION OF THE FLORIDA (INTERNATIONAL) <br />RESIDENTIAL CODE AND APPLICABLE COUNTY CODE AMENDMENTS. STANDARDS LISTED IN <br />STRUCTURAL NOTE SECTIONS REFER TO THE VERSION AND EFFECTIVE DATE IDENTIFIED IN THE <br />REFERENCED STANDARDS CHAPTER IN THE GOVERNING BUILDING CODE NOTED ABOVE. <br />2. THE STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS. SHOULD CONFUCTS <br />EXIST BETWEEN THE DRAWINGS AND THE STRUCTURAL NOTES, THE STRICTEST PROVISION <br />SHALL GOVERN. <br />3. THE STRUCTURAL DRAWINGS FORM AN INTEGRAL PART OF CONTRACT DOCUMENTS, WHICH <br />• INCLUDE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND CMUSITE DRAWINGS. <br />COORDINATE THE STRUCTURAL DRAWINGS WITH THE REQUIREMENTS SHOWN IN THE OTHER <br />COMPONENTS OF THE CONTRACT DOCUMENTS. <br />4. TYPICAL DETAILS AND OTHER SECnONS/DETAILS APPLY TO CONDITIONS THAT ARE SIMILAR TO <br />THE CONDITIONS DESCRIBED IN THE SECTIONS/DETAILS, EVEN IF THEY ARE NOT SPECIFICALLY <br />- REFERENCED ON THE PLANS. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS, METHODS SEQUENCES AND <br />PROCEDURES OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO TEMPORARY SHORING AND <br />BRACING. <br />S. DO NOT SCALE STRUCTURAL DRAWING& IF DIMENSIONS ARE OMITTED OR NOT CLEAR, <br />CONTACT THE ENGINEER. <br />7. CONSTRUCTION SHALL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF OSHA AND THE <br />LOCAL GOVERNING CODES, CURRENT EDITION, AND ALL REQUIREMENTS SPECIFIED IN THE <br />CODES SMALL BE ADHERED TO AS IF THEY WERE CALLED FOR OR SHOWN ON THE DRAWINGS. <br />THIS SHALL NOT BE CONSTRUED TO MEAN THAT REQUIREMENTS SET FORTH ON THE DRAWING <br />MAY BE MODIFIED BECAUSE THEY ARE MORE STRINGENT THAN THE CODE REQUIREMENTS OR <br />BECAUSE THEY ARE NOT SPECIFICALLY REQUIRED BY CODE <br />S. THE ENGINEER'S SEAL APPLIES ONLY TO THE STRUCTURAL COMPONENTS ON THIS DOCUMENT. <br />ALL DIMENSIONS ARE TO BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS. ANY DEVIATIONS <br />OR DISCREPANCIES ON THESE PLANS MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF <br />THE ENGINEER OF RECORD. BACK CHARGES WALL NOT BE ACCEPTED, REGARDLESS OF FAULT, <br />WITHOUT PRIOR NOTIFICATION BY BUILDER WITHIN 46-HOURS AND INVESTIGATION BY <br />FIELDSTONE. <br />9. THE TERMS'CONCRETE SCREW AND'MASONRY SCREW SHALL BE USED INTERCHANGEABLY <br />WITHIN THESE DRAWINGS. CONCRETEWM3NRY SCREWS AS GENERICALLY SPECIFIED WITHIN <br />THESE DRAWINGS SHALL REFER TO ONE OF THE FOLLOWING ACCEPTED MANUFACTURER <br />PRODUCTS: SIMPSON STRONG TIE T1TEN TURBO, GENUINE TAPCON, OR HILT! KWIK-CON IL <br />10. CONTENT LINKED WITHIN OR CODES THAT MAY BE SHOWN WITH THE DRAWING SET ARE FOR <br />INFORMATIONAL PURPOSES ONLY AND THE PROFESSIONAL SEAL ON THIS DRAWING DOES NOT <br />APPLY TO CONTENT CONTAINED WITHIN ANY OR CODES. <br />11. POST INSTALLED EPDXY ANCHORAGE GENERICALLY NOTED WITHIN THESE DRAWINGS SHALL BE <br />EITHER SIMPSON STRONG TIE SET-30, OR HILT] HIT-HY-150 <br />DESIGN CRITERIA: <br />BUILDING RISK CATEGORY <br />-II <br />VERTICAL LOADING: <br />ROOF TOP CHORD LIVE LOAD <br />-20 PSF (REDUCIBLE) <br />ROOF TOP CHORD DEAD LOAD <br />-7 PSF <br />ROOF TOP CHORD DEAD LOAD (TILE) <br />=15 PSF <br />ROOF BOTTOM CHORD LIVE LOAD (w/ STORAGE) _ <br />20 PSF <br />ROOF BOTTOM CHORD LIVE LOAD (w/o STORAGE) <br />_ 10 PSF <br />ROOF BOTTOM CHORD DEAD LOAD <br />-10 PSF <br />FLOOR LIVE LOAD <br />-40 PSF <br />FLOOR LIVE LOAD (SLEEPING ROOMS) <br />-30 PSF <br />FLOOR DEAD LOAD <br />-15 PSF <br />DECKGALCONY LIVE LOAD <br />-40 PSF <br />NOTE TO TRUSS & IJOIST MANUFACTURERS - ROOF & FLOOR SYSTEM DELEGATED DESIGN <br />SHALL CONFORM TO THE FOLLOWING DESIGN STANDARDS: <br />LOCATION <br />TOTAL LOAD <br />LIVE LOAD <br />MAX TOTAL <br />DEFLECTION <br />ROOF TRUSSES <br />I U240 <br />I L/240 <br />1 1° <br />FLOOR JOISTSRRUSS <br />I LI380 <br />L/480 <br />1 1/2' <br />NOTES: <br />1. MAXIMUM TOTAL LOAD DIFFERENTIAL DEFLECTION BETWEEN ADJACENT PARALLEL <br />MEMBERS SHALL BE 58' <br />2. ANY MEMBER SUPPORTING BRICKIMASONRY SHALL BE LIMITED TO A TOTAL LOAD <br />DEFLECTION OF USDA <br />3. FIELDSTONE AE CANNOT BE HELD RESPONSIBLE FOR ANY STRUCTURAL ISSUES RELATED <br />TO ANY BUILDING COMPONENT IF COMPONENT SHOP DRAWINGS ARE NOT SUBMITTED TO <br />FAE FOR REVIEW PRIOR TO FABRICATION, DELIVERY, OR INSTALLATION <br />3. LATERAL LOADING <br />WIND CRITERIA: <br />BASIC WIND SPEED -140 MPH <br />EXPOSURE CATEGORY =C <br />INTERNAL PRESSURE COEFFICIENT - +/- 0.18 (ENCLOSED) <br />SEISMIC CRITERIA <br />SITE CLASS -D <br />SEISMIC DESIGN CATEGORY -A <br />4. EARTH PRESSURE LOADING: <br />ALLOWABLE SOIL BEARING CAPACITY <br />TOTAL LOADS (INCLUDING NAND & SEISMIC) -2000 PSF <br />LATERAL EARTH EQUIVALENT FLUID PRESSURE <br />WALLS UNBRACED AT TOP -40 PCF <br />WALL BRACED AT TOP 755 PCF <br />S. GUARDRAILMANDRAIL LOADING: <br />ALL GUARDRAILMANDRAILS SHALL MEET 200 LBS (MINIMUM) CONCENTRATED FORCE APPLIED <br />IN ANY DIRECTION. IN -FILL COMPONENTS OF GUARDRAIL SHALL MEET 50 PSF. THESE LOADS <br />ARE TO BE EVALUATED INDEPENDENTLY AND ARE NOT TO ACT CONCURRENTLY WITH ANY <br />OTHER LIVE LOAD. DEFLECTION OF GUARDRAIL SHALL MEET THE CRITERIA SET FORTH BY THE <br />INTERNATIONAL CODE COUNCIL EVALUATION SERVICES #CC -ES) AC 273 -'ACCEPTANCE <br />CRITERIA FOR HANDRAILS AND WARDS.' <br />CONCRETE NOTES: <br />1. STRUCTURAL CONCRETE HAS BEEN DESIGNED IN ACCORDANCE PER ACI 332'RESIDENTIAL <br />CODE REQUIREMENTS FOR STRUCTURAL. CONCRETE'. <br />2. CONCRETE PRODUCTION AND PLACEMENT SMALL CONFORM TO THE REQUIREMENTS OF ACI 332 <br />'RESIDENTIAL CODE REQUIREMENTS FOR STRUCTURAL CONCRETE' EXCEPT AS MODIFIED BY <br />STRUCTURAL REQUIREMENTS NOTED ON THE DRAWINGS. <br />3. CEMENT SHALL CONFORM TO ASTM C1 50 'SPECIFICATION FOR PORTLAND CEMENT.' CONCRETE <br />SHALL BE NORMAL WEIGHT, UNLESS INDICATED OTHERWISE. <br />4. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C33'SPECIFICATION FOR CONCRETE <br />AGGREGATES.' <br />5. REINFORCING SHALL CONFORM TO ASTM A-615 GRADE SM <br />S. REINFORCEMENT SHALL BE FABRICATED AND ERECTED ACCORDING TO THE ACI STANDARDS: <br />'DETAILS AND DETAILING OF CONCRETE REINFORCEMENT, ACI 315 - AND UMUAL OF <br />ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES', AC1315FL <br />7. REINFORCING STEEL AND WELDED WIRE FABRIC SHALL BE PLACED WITH MINIMUM CONCRETE <br />COVER AND TOLERANCES AS FOLLOWS: <br />BLM ONdITADE WITHIN UPPER 2/3 OF SLAB AND 3/4' MINIMUM COVER AT INTERIOR <br />CONDITIONS; 1-1/Y MINIMUM COVER AT EXTERIOR CONDITIONS <br />OONC E BOUNDATIONABABNTSUM 3' <br />PDP� OONgETM 1-1W (#5 REBAR OR SMALLER) r (#6 FEW OR LARGER) <br />TOLERANCE +I.3w <br />S. REINFORCING STEEL SMALL NOT BE CUT, BENT OR STRAIGHTENED IN THE FIELD UNLESS <br />APPROVED BY THE STRUCTURAL ENGINEER OR AS INDICATED ON THE DRAWINGS. <br />9. WELDING OF REINFORCING STEEL IS PROHIBITED UNLESS SPECIFICALLY DETAILED. WELDING <br />WHERE DETAILED SHALL CONFORM TO AWS DI A SPECIFICATION. <br />CONCRETE NOTES (CONTINUED): <br />10. CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH AS FOLLOWS: <br />FOUNDATIONS & FOUNDATION WALLS: 2600 PSI <br />SLAB -ON -GRADE & CONCRETE BEAMS: 25W PSI <br />11. CONTRACTOR SHALL TIE REINFORCING STEEL SECURELY IN PLACE PRIOR TO PLACING <br />CONCRETE AND PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THEIR POSITION WITHIN <br />SPECIFIED TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES. INSERTING DOWELS INTO <br />WET CONCRETE IS NOT PERMITTED. ANCHOR RODS AND STEEL INSERTS SHALL BE SET BY <br />TEMPLATE TO WITHIN A 1/8' TOLERANCE IN ANY DIRECTION WITH MINIMUM EMBEDMENT AND <br />EXACT PROJECTION INDICATED ON THE DRAWINGS, PRIOR TO PLACING CONCRETE. <br />12. HOOKED BARS SHALL BE STANDARD 90 DEGREE HOOKS PER ACI UNLESS NOTED OTHERWISE ON <br />THE DRAWINGS. MINIMUM LAP SPLICE SHALL BE CLASS B PER ACI 31 S. LOCATION OF LAP <br />SPLICES SHALL BE AS INDICATED ON CONSTRUCTION DOCUMENTS, <br />13. DOWELS INTO FOUNDATION SHALL MATCH SIZE AND SPACING OF VERTICAL REINFORCEMENT AT <br />ALL COLUMNS, PIERS AND WALLS, UNLESS OTHERWISE NOTED. <br />14. CONTRACTOR SHALL OBTAIN APPROVAL PRIOR TO PLACING OPENINGS OR SLEEVES NOT SHOWN <br />ON THE DRAWINGS, THROUGH ANY STRUCTURAL MEMBER. <br />I S. ONE OF THE FOLLOWING CONCRETE SLAB ON GRADE CRACK CONTROL METHODS SHALL BE <br />USED (CONTRACTOR PREFERENCE): <br />• CONTROL JOINTS: SHALL BE FORMED, SAWED, OR TOOLED TO A 1' MINIMUM DEPTH WITHIN <br />24 HOURS OF CONCRETE PLACEMENT. MAXIMUM JOINT SPACING FOR UNREINFORCED SLAB <br />IS AS FOLLOWS: <br />3.1/2" SLAB: 8 FEET O.C. EACH DIRECTION <br />4' SLAB: 10 FEET O.C. EACH DIRECTION <br />• WELDED WIRE FABRIC (W.WF) 8X6-W1.4XW1.4. WELDED WIRE FABRIC SHALL BE FURNISHED IN <br />FLAT SHEETS (ROLLS NOT PERMITTED) AND SHALL CONFORM TO ASTM A-1004 AND HAVE A <br />MINIMUM SIDE AND END LAP OF 8 INCHES. <br />• MICRO- OR MACRO- SYNTHETIC FIBER REINFORCEMENT <br />FIBER LENGTHS SHALL BE 1/7 TO 2.1/4" IN LENGTH. DOSAGE AMOUNT SHALL BE FROM 314 TO <br />3.0 POUNDS IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. SYNTHETIC <br />FIBERS SHALL COMPLY WITH ASTM CI118. THE MANUFACTURER/SUPPLIER SHALL PROVIDE <br />CERTIFICATION OF COMPLIANCE WITH ASTM C1116 WHEN REQUESTED BY THE BUILDING <br />OFFICIAL- <br />1 & CONTROL JOINTS SHALL BE FURNISHED WITH A FULL-LENGTH KEYWAY CENTERED ON MEMBERS. <br />WHERE THE SIZE OF KEY IS NOT SHOWN ON THE DRAWINGS, THE KEY SHALL BE 25% OF THE <br />CROSS-SECTION DIMENSION OF THE MEMBER AND MINIMUM 1-112 INCHES INTO THE FIRST POUR <br />OF CONCRETE <br />17. PROVIDE POCKETS OR RECESSES IN CONCRETE WORK FOR COLUMNS AND BEAMS AS REQUIRED <br />EVEN IF NOT SHOWN ON THE DRAWINGS. PROVIDE CONCRETE FILL AFTER BEAM ERECTION. <br />1 & CURING OF CONCRETE SURFACES SHALL CONFORM TO ACI 308.1 'STANDARD SPECIFICATION <br />FOR CONCRETE CURING' AND ACI 30SR'GUIDE TO CURING CONCRETE'. <br />FOUNDATION NOTES: <br />1. CONTRACTOR SMALL VERIFY ALL CONDITIONS, INCLUDING UNDERGROUND UTILITIES AND FIELD <br />MEASUREMENTS AT JOB SITE AND REPORT ANY DISCREPANCIES TO OWNER'S REPRESENTATIVE <br />2. TOP OF SPREAD FOOTING ELEVATIONS NOTED ON PLAN ARE MINIMUM ELEVATIONS. IN ALL CASES <br />FOOTINGS ARE TO BEAR ON UNDISTURBED NATURAL SOILS OR ENGINEERED FILL HAVING A <br />MINIMUM NET ALLOWABLE BEARING CAPACITY OF 2WO PSF. <br />3. SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING <br />FOUNDATIONS POURED AGAINST THE EARTH REQUIRED THE FOLLOWING PRECAUTIONS: SLOPE <br />SIDES OF EXCAVATIONS AS APPROVED BY GEOTECHNICAL ENGINEER AND CLEAN UP SLOUGHING <br />BEFORE AND DURING CONCRETE PLACEMENT. PROVIDE POLYETHYLENE VAPOR RETARDER <br />COMPLYING WITH GOVERNING BUILDING CODE LISTED ON THIS SHEET AGAINST SOILS WHERE <br />CONCRETE IS TO BE PLACED; LAP ALL EDGES B INCH (MINIMUM) AND SEAL WITH ADHESIVE <br />4. WHERE FOOTING STEPS ARE NECESSARY, THEY SHALL BE NO STEEPER THAN ONE VERTICAL TO <br />TWO HORIZONTAL U.N.O. <br />5. FOOTINGS SHALL BE CENTERED UNDER COLUMNS AND WALLS UNLESS SPECIFICALLY DETAILED <br />OTHERWISE ON THE DRAWINGS. <br />S. NO FOOTINGS OR SLABS SHALL BE PLACED ON OR AGAINST SUB -GRADE CONTAINING FREE <br />WATER, FROST OR ICE. SHOULD WATER OR FROST, HOWEVER SLIGHT, ENTER A FOOTING <br />EXCAVATION AFTER SUB -GRADE APPROVAL, THE SUB -GRADE SHALL BE RE INSPECTED BY THE <br />GEOTECHNICAL ENGINEER/ TESTING LABORATORY AFTER REMOVAL OF WATER OR FROST. <br />7. CONTRACTOR SHALL FURNISH ALL REQUIRED DE -WATERING EQUIPMENT TO MAINTAIN A DRY <br />EXCAVATION UNTIL BACKFILL IS COMPLETE. <br />S. A GEOTECHNICAL ENGINEER REGISTERED IN THE STATE OF WORK PERFORMED SHALL INSPECT <br />THE CONDITION AND ASSURE THE ADEQUACY OF ALL SITE PREPARATION, SUBGRADES, FILLS, <br />BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS AND WALLS. HE SHALL <br />SUBMIT REPORT TO THE ARCHITECT/ENGINEER DESCRIBING HIS INVESTIGATIONS OF ANY <br />NON -CONFORMING WORK <br />BACIFILLING: <br />1. DO NOT PLACE BACKFILL AGAINST FOUNDATION WALLS - DESIGNED AS SUPPORTED AT TOP AND <br />BOTTOM - UNTIL BASEMENT LEVEL AND FIRST FLOOR SYSTEM ARE IN PLACE. SHORE AND/OR <br />BRACE WALLS AS REQUIRED IF RACKFILLING OPERATIONS ARE TO BE CARRIED OUT PRIOR TO <br />PLACEMENT OF FLOOR SYSTEM. <br />2. WHERE BACKFILL IS TO BE PLACED ON BOTH SIDES OF FOUNDATION WALLS, PROVIDE A <br />BALANCED BACKFILL AGAINST FOUNDATION WALLS TO ELIMINATE LATERAL LOAD EFFECTS, OR <br />PROVIDE NECESSARY TEMPORARY LATERAL SUPPORT TO THE TOP OF THE WALL UNTIL <br />PERMANENT SUPPORT IS INSTALLED. <br />3. BACKFILL MATERIAL SHALL CONSIST OF CLEAN, WELL GRADE GRANULAR SOILS, FREE OF <br />ORGANIC MATERIAL AND BE COMPACTED TO 95% OF MAXIMUM DENSITY, AS DETERMINED BY <br />THE MODIFIED PROCTOR METHOD (ASTM D1557), IN LIFTS NOT EXCEEDING 8INCHES. <br />MASONRY NOTES: <br />1. CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 530, "BUILDING CODE <br />REQUIREMENTS FOR MASONRY STRUCTURES" AND SHALL BE CONSTRUCTED IN ACCORDANCE <br />WITH ACI SMA. "SPECIFICATIONS FOR MASONRY STRUCTURES" <br />2. CONCRETE MASONRY SHALL CONFORM TO ASTM COD AND HAVE A MINIMUM COMPRESSIVE <br />STRENGTH FWn - 1,500 PSI U.O.N. MASONRY SHALL HAVE A TEXTURE SUITABLE FOR STUCCO <br />APPLICATIONS WHERE ARCHITECTURAL DRAWINGS INDICATE STUCCO APPLICATION. <br />3. CONCRETE MASONRY UNITS SHALL BE W D IN RUNNING BOND. <br />4. MORTAR FOR ALL MASONRY SHALL CONFORM TO ASTM C270 WITH MINIMUM COMPRESSIVE <br />STRENGTH OF 2,000 PSI. MORTAR BELOW GRADE SHALL BE TYPE M. ELSEWHERE MORTAR MAY <br />BE EITHER TYPE M OR S UNLESS SPECIFICALLY INDICATED OTHERWISE. USE EITHER PORTLAND <br />CEMENTNME OR MASONRY CEMENT FOR MORTAR. <br />5. GROUT SHALL CONFORM TO ASTM C478 WITH MINIMUM 28-DAY COMPRESSIVE STRENGTH OF <br />2,500 PSI. <br />8. STEEL BAR REINFORCEMENT SHALL CONFORM TO ASTM A815, GRADE 6& <br />7. VERTICAL CELLS CONTAINING REINFORCING AND GROUT SHALL FORM A CONTINUOUS CAVITY, <br />FREE OF MORTAR DROPPINGS. <br />& VERTICAL CMU WALL REINFORCING SHALL BE AS NOTED ON THE DRAWINGS. DOWELS TO <br />CONCRETE FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL REINFORCING UNLESS <br />NOTED OTHERWISE. REINFORCE CMU CORE AT CORNERS, EACH SIDE OF CONTROL JOINTS AND <br />EACH SIDE OF WALL OPENINGS WITH (1)45 CONTINUOUS VERTICAL REINFORCING BARS.. <br />9. HORIZONTAL BOND BEAM AND VERTICAL REINFORCING SHALL BE CONTINUOUS U.O.N. LAP <br />SPLICE REINFORCING PER THE SCHEDULE OR USE MECHANICAL SPLICES ADEQUATE FOR 125% <br />OF SPECIFIED YIELD STRENGTH OF THE BAR. LAP VERTICAL REINFORCEMENT WITH MINIMUM <br />DOWELS OF SAME SIZE AND SPACING THAT HAVE BEEN PREVIOUSLY INSTALLED IN THE <br />FOUNDATIONS. DOWEL EMBEDMENT IN CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF <br />THE CONCRETE NOTES, <br />BARSIZE <br />LAP SPLICE LENGTH <br />BEND DIAMETER <br />ACI HOOK <br />#4 <br />20' <br />3' <br />1 w <br />#5 <br />2S <br />"r <br />Ur <br />#6 <br />34' <br />4.1/r <br />11" <br />MASONRY NOTES (CONTINUED): <br />10. REINFORCING BARS SHALL BE HELD IN POSITION BY WIRE TIES OR OTHER APPROVED MEANS TO <br />ENSURE DESIGN LOCATION AND LAP. PLACE BARS AND LAP PRIOR TO GROUTING. <br />11. GROUTING OF MASONRY WALLS SHALL CONFORM TO RECOMMENDED PROCEDURE FOR 'LOW <br />LIFT GROUTING" OR'HIGH LIFT GROUTING" AS OUTLINED IN THE NC"TEK 3.2A - GROUTING <br />FOR CONCRETE MASONRY WALLS AND ACI 530/ASCE 5 SPECIFICATION FOR MASONRY <br />STRUCTURES. GROUT LIFTS SHALL NOT EXCEED 5 FEET WITHOUT MECHANICALLY <br />CONSOLIDATED (VIBRATED) GROUT POURS. <br />M � <br />12. LIFTS OF GROUT SHALL BE KEYED 41NCHES INTO THE PREVIOUS COURSE OF MASONRY BELOW. <br />13. MASONRY BELOW GRADE SHALL BE GROUTED SOLID. <br />14. CONTRACTOR SHALL BRACE MASONRY WALLS TO RESIST NAND LOADS UNTIL FLOORS AND <br />ROOFS ARE IN PLACE, AND THE MASONRY HAS REACHED 75% OF THE REQUIRED STRENGTH FM. <br />BRACING SHALL BE PROVIDED IN ACCORDANCE WITH OSHA - CONSTRUCTION SAFETY <br />STANDARDS FOR MASONRY WALL BRACING AND NCMA TEK 3-48 -'BRACING CONCRETE <br />MASONRY WALLS DURING CONSTRUCTION. - <br />WOOD FRAMING NOTES: <br />1. STRUCTURAL SAWN LUMBER, STRUCTURAL COMPOSITE LUMBER, AND CONNECTIONS HAVE <br />BEEN DESIGNED IN ACCORDANCE WITH THE'NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION." (NDS) <br />2. PLYWOOD HAS BEEN DESIGNED IN ACCORDANCE WITH "PANEL DESIGN SPECIFICATION.* AND <br />SHALL CONFORM TO'VOLUNTARY PRODUCT STANDARD PSI CONSTRUCTION AND INDUSTRIAL <br />PLYWOOD.' <br />3. ORIENTED STRAND BOARD (OSB) SHALL CONFORM TO "VOLUNTARY PRODUCT STANDARD PS2 <br />PERFORMANCE STANDARD FOR WOOD -BASED STRUCTURAL -USE PANELS'. <br />4. ALL BEAMS AND HEADERS SHALL BE M-PLY IldLO. <br />5. WOOD SILL PLATES AND WOOD WALLS SUPPORTED ON CONTINUOUS CONCRETE OR MASONRY <br />SHALL BE ANCHORED WITH 11r DIAMETER CAST -IN -PLACE ANCHOR BOLTS WITH T EMBEDMENT, <br />4- (MINIMUM) AND 12- (MAXIMUM) FROM END OF SILL PLATE(S), LOCATED WITHIN THE MIDDLE <br />THIRD OF THE SILL PLATE, WITH NUT AND 3'x3'x0229' WASHERS AT THE ANCHOR SPACING <br />BELOW: <br />MAXIMUM ANCHOR BOLT SPACING = 7-0' O.C. <br />REFER TO "PRE -APPROVED FIELD REPAIR NOTES' SECTION FOR ALTERNATE ANCHORAGE <br />APPROVALS. FOR OTHER ANCHORS NOT LISTED, SUBMIT TO ENGINEER OR RECORD FOR <br />REVIEW. <br />S. ALL LUMBER IN CONTACT WITH EARTH, CONCRETE, OR MASONRY - AND WOOD BEAMS <br />POCKETING INTO CONCRETE OR MASONRY WALLS HAVING CLEARANCES LESS THAN i/7ON <br />TOP, SIDES, AND END(S) SHALL BE PRESSURE TREATED OR SEPARATED WITH AN IMPERVIOUS <br />MOISTURE BARRIER <br />7. STRUCTURAL SAWN LUMBER SHALL BE SPRUCE -PINE -FIR NOA /NO.2 OR BETTER U.N.O. WITH <br />BASE DESIGN VALUES: <br />Fe- 875 PSI F� - 425 PSI FT - 45O PSI Fo- 1150 PSI FV- 135 PSI E- 1400 KSI <br />WITH THE MOISTURE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%. <br />S. BEARING AND EXTERIOR WALL STUDS SHALL BE CAPPED WITH DOUBLE (2X) TOP PLATES <br />INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT INTERSECTIONS. END JOINTS IN <br />DOUBLE (2)) TOP PLATES SHALL BE OFFSET AT LEAST 24 INCHES AND SHALL BE NAILED WITH <br />NOT LESS THAN (8)-0.18252.1/Y FACE NAILS ON EACH SIDE THE JOINT. DOUBLE (M TOP PLATES <br />OF EXTERIOR WALLS AND INTERIOR LOAD BEARING WALLS SHOWN ON DRAWINGS SHALL BE <br />SOUTHERN YELLOW PINE NO.2 OR BETTER WITH BASE DESIGN VALUES: <br />Fe- 1100 PSI F - 565 PSI FT= 875 PSI FO- 145O PSI FV- 175 PSI E- 140O KSI <br />WITH THE MOISTUA CONTENT OF THE WOOD IN SERVICE WALL NOT EXCEED 19%. <br />9. STRUCTURAL COMPOSITE LUMBER SHALL CONFORM TO ASTM D 5456 WITH THE FOLLOWING <br />ALLOWABLE DESIGN STRESSES <br />MICROLlA1M LVL PARALLAM Fill. MI 7*AN9WFRAIW L8L <br />E - 2000 KSI E - 1800 KSI E - 1300 KSI <br />Fe - 26M PSI Fe - 2400 PSI Fe - 1700 PSI <br />(h -'BOOZER BEAM 2.1 E' ARE AN ACCEPTED ALTERNATE TO PSL COLUMNS SPECIFIED <br />ON PLANS PROVIDED THE'SOOZER BEAM 2.1 E IS OF EQUAL OR GREATER SECTION <br />DIMENSION TO THE PSL COLUMN AND OF EQUAL OR LESSER HEIGHT <br />10. FLOOR SHEATHING SHALL BE 23A32 INCH, APA RATED SHEATHING, 4OV24 MIN., EXPOSURE 1. <br />INSTALL WITH THE LONG DIMENSION OR STRENGTH AXIS OF THE PANEL ACROSS SUPPORTS <br />AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPARS. PANEL EDGES SHALL BE <br />TONGUE -AND -GROOVE. FLOOR SHEATHING SHALL BE GLUED AND NAILED TO SUPPORTING <br />MEMBERS. ADHESIVE SHALL MEET APA SPECIFICATION AFG.01, APPLIED IN ACCORDANCE WITH <br />THE MANUFACTURERS RECOMMENDATIONS, PROVIDE 0.131"2-1/2' COMMON NAILS AT 6INCH <br />O.0 ALONG SUPPORTED PANEL EDGES AND 12 INCH O.0 AT INTERMEDIATE SUPPORTS. <br />11. FOR INTERIOR WALL HEADERS PROVIDE (1)-2X JACK STUD AND (1)-2X KING STUD U.N.O.ON <br />DRAWINGS. <br />12. FOR EXTERIOR WALL HEADERS PROVIDE (1)-2x JACK STUD AND (1)-2x KING STUD, MINIMUM, <br />REFER TO CHART BELOW U.N.O ON DRAWINGS: <br />WINDSPEED OF <br /><- 140 EXP. C <br />WALL HEIGHT <br />OFT <br />OFT <br />10FT <br />STUD <br />SIZE <br />HEADER SPAN <br />(FT) <br />4 <br />1JAK <br />1JAK <br />IJAK <br />8 <br />1J/1K <br />1J/1K <br />1JA2K <br />8 <br />1J/1K <br />IJ/2K <br />1J/3K <br />10 <br />1J/2K <br />1J12K <br />1JAK <br />2x4 <br />12 <br />1J/2K <br />IIJAK <br />1J/IK <br />14 <br />1J/2K <br />1J14K <br />I END <br />16 <br />IJ13K <br />1J14K <br />ENO <br />18 <br />1J/SK <br />ENO <br />ENO <br />WINDSPEED OF <br /><- 140 EXP. C <br />WALL HEIGHT <br />8FT <br />SIFT <br />1 OFT <br />STUD <br />SIZE <br />HEADER SPAN <br />(Fn <br />4 <br />1JAK <br />1JAK <br />1JAK <br />6 <br />1IJ/1K <br />1J/1K <br />1J/1K <br />8 <br />1JA1K <br />1JAiK <br />1J/1K <br />10 <br />IJ/1K <br />1J/1K <br />1J/1K <br />2x8 <br />12 <br />IJA1K <br />IJ/1K <br />1JA1K <br />14 <br />1JA1K <br />1J11K <br />1JA1K <br />16 <br />1J/1K <br />1J/1K <br />1J/1K <br />18 <br />1JAK <br />1JA1K <br />1J/1K <br />13. WALLS SHOWN ON THE FRAMING PLANS ARE LOAD BEARING WALLS; WALLS NOT SHOWN ON <br />STRUCTURAL FRAMING PLANS ARE INTERIOR NON -LOADING BEARING PARTITION WALLS, <br />14.LOAD BEARING WALLS SHALL BE CONSTRUCTED WITH 2X STUDS AT I W O.C. MAXIMUM U.N.O. <br />NON -LOAD BEARING PARTITION WALLS SHALL BE CONSTRUCTED WITH 2X OR METAL STUDS (18 <br />GA MIN.) ® 24- O.C. MAXIMUM. <br />15. STUD COLUMNS UNDER LOAD BEARING POINTS OF GIRDERSA3EAMS SHALL MATCH THE <br />GIRDER/BEAM PLY COUNT WITHIN 1/r TOLERANCE 12-PLY STUD COLUMN MINIMUM). SOLID <br />BLOCK ALL GIRDER/BEAMS THRU FLOOR SYSTEMS AND TO THE FOUNDATION. <br />i 8. WHEN NOT SHOWN ON DRAWINGS OR DETAILS, THE NAILING SCHEDULE FOR WOOD FRAMING <br />ELEMENTS SHALL COMPLY WITH THE IRC TABLE RMU(1). <br />17. FLOOR SYSTEMS ARE DESIGNED BY THE TRUSS AND/OR WOOD I- JOIST MANUFACTURERS <br />DELEGATED ENGINEER AND BE IN CONFORMANCE WITH THE LOADS & DEFLECTIONS IDENTIFIED <br />IN THE DESIGN CRITERIA NOTES SECTION. INSTALL PER MANUFACTURERS RECOMMENDATIONS, <br />NOTES, AND DETAILS. FLOOR FRAMING CONCEPT LAYOUTS SHOWN WITHIN THE DRAWINGS ARE <br />FOR ILLUSTRATIVE PURPOSES ONLY TO DEPICT FLOOR SYSTEM -TO -WALL CONNECTIONS. <br />CHANGES TO THE CONCEPTUAL FLOOR LAYOUT SHOWN IS NOT PERMITTED WITHOUT A LETTER <br />AND REVIEW FROM THE ENGINEER OF RECORD. PREFABRICATED WOOD WOIST SHALL <br />CONFORM TO ASTM D WW <br />JURISDICTION SPECIFIC NOTES: <br />1. FOR PARTIALLY ENCLOSED AREAS, INCLUDING BUT NOT LIMITED TO LANAIS, PORCHES, AND <br />BALCONIES A 1/r (MINIMUM) EXTERIOR GRADE SOFFIT BOARD WITH A CEMENTRIOUS <br />KNOCKDOWN FINISH S ACCEPTABLE PROVIDED THAT IT IS PAINTED MEETING THE <br />REQUIREMENTS OF ASTM CM TO GIVE THE CEILING WATER RESISTANCE. THE SOFFIT BOARD <br />PRODUCT SHALL BE ATTACHED PER MANUFACTURER SPECIFICATIONS TO BE IN COMPLIANCE <br />WITH R703.1. <br />2. THE SOFFIT DESIGN PRESSURE S AS NOTED IN THESE DOCUMENTS. WITH KAYCAN VINYL SOFFIT <br />INSTALLED IN ACCORDANCE WITH MANUFACTURERS REOUIRIMEHTS AND ICC-ES EVALUATION <br />REPORT ESR-1495 THE SOFFIT WILL COMPLY WITH R703.1. <br />PRE-ENGINEERED ROOF TRUSS NOTES: <br />1. ROOF TRUSS SHOWN ON STRUCTURAL DRAWINGS IN CONCEPTUAL ONLY TO ILLUSTRATE <br />TRUSS -TO WALL CONNECTIONS AND DOES NOT SERVE AS A ROOF TRUSS DESIGN. ROOF <br />TRUSSES SHALL BE DESIGNED AND MANUFACTURED IN CONFORMANCE FOR THE INDICATED <br />LOADS WITH ANSI/TPI 1 "NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD <br />TRUSS CONSTRUCTION.' FINAL PRE-ENGINEERED ROOF TRUSS FRAMING LAYOUT AND DESIGNS <br />TO BE BY ROOF MANUFACTURERS DELEGATED ENGINEER. <br />2. ROOF TRUSSES SHALL BE DESIGNED FOR THE SUPERIMPOSED LOADS IDENTIFIED IN THE <br />DESIGN CRITERIA NOTES SECTION. <br />3. THIS PLAN IS DEVELOPED FROM THE REVIEW OF MASTER TRUSS FILES. ANY LOT THAT DEVIATES <br />S <br />FROM THE MASTER TRUSS FILE ON RECORD,OR FOR PLANS FIELDSTONE AE IS NOT <br />CONTRACTED TO PERFORM TRUSS REVIEW ON, THE CONTRACTOR IS RESPONSIBLE TO ASSURE <br />THE DIRECT COMPLIANCE OF TRUSS MANUFACTURER LAYOUT TO THESE DRAWINGS & VERIFY <br />ALL TRUSS CONNECTORS ARE SUFFICIENT TO WITHSTAND THE UPLIFTMTERAL LOADS IMPOSED <br />4. TRUSS MANUFACTURER SHALL PROVIDE HANGERS AND CONNECTIONS ADEQUATE FOR LOADS <br />AT ALL TRUSS -TO -TRUSS, TRUSS -TO -BEAM, AND BEAM -TO -TRUSS CONNECTIONS. <br />S. REFER TO ARCHITECTURAL DRAWINGS FOR TRUSS SHAPE, OVERHANG, DIMENSIONS, SLOPES, <br />SPANS, DRAINAGE, BEARING WALL HEIGHTS, ETC. <br />S. THE POSITIONS, WEIGHTS, AND METHODS OF ATTACHMENTS OF ALL MECHANICAL UNITS, <br />ELECTRICAL FIXTURES, PLUMBING, FIRE SPRINKLERS, ETC SHALL BE INCLUDED IN THE DESIGN <br />OF THE TRUSSES BY THE TRUSS MANUFACTURER. SEE ARCHITECTURAL DRAWINGS FOR ATTIC <br />ACCESS SIZE AND LOCATIONS. <br />7. SUPERIMPOSED LOADS FROM SECONDARY FRAMING (LE. SOFFITS, PARAPETS, VALLEY FRAMING, <br />UPPER TRUSSES, ETC) SHALL BE INCLUDED IN THE DESIGN OF SUPPORTING TRUSSES. <br />S. CONTRACTOR TO PROVIDE TRUSS BRACING PER BCSI.83IN ADDITION TO PERMANENT BRACING <br />SHOWN ON THE TRUSS DESIGN PROVIDED BY THE DELEGATED TRUSS ENGINEER. <br />PRE APPROVED FIELD REPAIR NOTES: <br />i. MISPLACED DOWEL REPAIR: THIS NOTE DESCRIBES ALTERNATES TO MITIGATE THE CASTING OF <br />REBAR VERTICAL REINFORCEMENT AT AN INCORRECT LOCATION. <br />IF THE WALL HAS NOT BEEN BUILT: DRILL AND EPDXY #5 REBAR (36" LG.) INTO THE THICKENED <br />EDGE OF SLAB AT THE CORRECT LOCATION. AS WALL IN CONSTRUCTED, LAP REBAR IN <br />ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 12- LAP AT <br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAM/BOND BEAM. COMPLETE <br />GROUTING OF WALL. <br />IF THE WALL HAS ALREADY BEEN BUILT: PRIOR TO GROUT PLACEMENT, OPEN THE WALL AT THE <br />CORRECT LOCATION APPROXIMATELY 1S" (H) x 4' (W) AT FLOOR LEVEL DRILL AND EPDXY #5 <br />REBAR (32' LG.) INTO THE THICKENED EDGE OF SLAB. LAP VERTICAL REINFORCEMENT IN <br />ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR NTH 12' LAP AT <br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAMBOND BEAM. COMPLETE <br />GROUTING OF WALL. <br />2. MISSING/MISPLACED ANCHOR BOLT: ALTERNATE SILL PLATE ANCHORAGE SOLUTIONS <br />KIO CONCIEIIE: <br />A 1/2'A' T1TEN HO WITH 1.3/4" MINIMUM EDGE DISTANCE AND W MINIMUM END DISTANCE IS A <br />DIRECT 1:1 REPLACEMENT FOR A 1/2" DIAMETER ANCHOR BOLT WITH 7' EMBEDMENT INTO <br />CONCRETE <br />A 1 /r THREADED ROD SETJG EPDXY T EMBEDMENT WITH 1-W4- MINIMUM EDGE DISTANCE AND <br />7-1/2- MINIMUM END DISTANCE IS A DIRECT 1:1 REPLACEMENT FOR A 1 /2' DIAMETER ANCHOR <br />BOLT WITH 7" EMBEDMENT INTO CONCRETE. <br />MITO 611101IT FLL® MABCN Y MOM: <br />A 1 /2'A' TITEN HD WITH 1.3/4" MINIMUM EDGE DISTANCE AND 8' MINIMUM END DISTANCE AT 4'-8' <br />O.C. REPLACES A 1/2" DIAMETER ANCHOR BOLT WITH T EMBEDMENT AT 6-0' O.C.; UKEWISE A <br />112-A- TITEN HD WITH I-W4- MINIMUM EDGE DISTANCE AND 8' MINIMUM END DISTANCE AT 2-W <br />O.C. REPLACES A 1/2' DIAMETER ANCHOR BOLT WITH T EMBEDMENT AT 4'-W O.C.. <br />3. SIMPSON MASH SILL ANCHORS MAY BE USED AS AN ALTERNATE TO THE ANCHOR BOLTS AND <br />SPACING NOTED HERE -IN ACCORDING TO THE FOLLOWING TABLE: <br />BASIC WIND <br />SPEED (MPH) <br />MAXIMUM <br />SPACING <br /><140 <br />6A' <br />140 <br />V4r <br />ISO <br />1'-3' <br />NOTES: <br />1. MASA SPACING BASED ON NO MORE THAN ONE IN THREE INSTALLED WITH ONE LEG <br />INSTALLED VERTICALLY ATTACHED TO STUD <br />4. MISSING/MISPLACED TRUSS STRAP ANCHOR: REFER TO'MISSED TRUSS STRAP REPAIR" DETAIL <br />WITHIN DRAWINGS. <br />FOR MISLOCATED TRUSS ANCHORS WHICH ARE GREATER THAN 11W BUT LESS THAN 1-1/2" FROM <br />THE FACE OF THE TRUSS, A SHIM SHALL BE PROVIDED AND NAIL LENGTH INCREASED TO <br />PENETRATE THROUGH BOTH PLYS OF MATERIAL Q.E. 3- LG. NAILS). WHEN GAP IS GREATER THAN <br />1-1/2", INSTALL NEW ANCHORS. <br />S. MASONRY WALL OVERHANGING SLAB <br />KMOVERHOR FE <br />< 5A8' NO REPAIR REOD <br />5/8' < OVERHANG < 1.1/2' GROUT SOLID BOTTOM 3 COURSES OF AFFECTED WALL LENGTH <br />>I-I/Y CONTACT ENGINEER OF RECORD FOR REPAIR <br />S. NOTCHED TOP PLATES & STUDS REQUIRING REPAIR <br />AT STUDS: STRUCTURAL REPAIR IS REQUIRED AT STUDS WHEN A STUD IS NOTCHED TO A DEPTH <br />GREATER THAN 25% OF THE WIDTH IN BEARING WALLS, OR 40% IN NON -LOAD BEARING WALLS; <br />OR WHEN A HOLE IS DRILLED/BORED TO A DIAMETER EXCEEDING 40% OF THE STUD WIDTH IN <br />BEARING WALLS, OR 60%OF THE STUD WIDTH IN NON -BEARING WALLS. IF THE MAXIMUM <br />MOLENOTCH SPECIFICATIONS ARE EXCEEDED THEN A STUD SHOE MUST BE INSTALLED. STUD <br />SHOE REPAIRS ARE AS FOLLOWS: FOR 2X STUD USE HS324081.5 WITH (I2)-tµ'X1-1/Y BIDS <br />SCREWS. FOR MULTI -PLY 2X STUDS USE HSS2-'#--SDS3 WITH (12)-1/4'XS' BOB SCREWS, WHERE <br />#• CORRESPONDS TO THE NUMBER OF STUDS IN THE MULTI -PLY. <br />AT TOP PLA7m: A HOLE, CUT, OR NOTCH THAT IS GREATER THAN 60% OF THE PLATE WIDTH IS <br />REMOVED FOR PIPING (EXCEPT WHEN THE SIDE OF THE WALL WITH THE NOTCH OR CUT S <br />COVERED BY WOOD STRUCTURAL PANEL SHEATHING), OR THE PLATES ARE CUT THROUGH. THE <br />REQUIRED REPAIR IS A GALVANIZED i&GAUGE METAL TIE THAT IS AT LEAST 1-1W WIDE AND <br />MUST BE FASTENED WITH (8)-1 SO NAILS ON EACH SIDE OF THE OPENING <br />Fieldstone ����� gyp"!' . �I►j / t/�i <br />C.O•A.# ARCHITECURE: ����:!• ' F <br />AA26002802 <br />C.O.E.# ENGINEERING: No. _ <br />29349 - - <br />D IBRAHEM ELAYEB, PE <br />P.E.# 91476 '• �� <br />■ BENJAMIN NIESE, PE <br />P.E.# 86025 <br />02/12/2024 <br />O FAI rE OF <br />C <br />111ill111100 <br />Michigan <br />3400 Auburn Rd <br />Suite 200 <br />Auburn Hills, MI 48326 <br />+1 248.622.4035 <br />Florida <br />12906 Tampa Oaks Blvd. <br />Suke 150 <br />Tampa, FL 33637 <br />+1 813.466.3310 <br />www.fteldstoneae.com <br />C'0 <br />0 <br />O <br />v <br />J <br />Y <br />W Z � <br />5a <br />Z <br />JCC <br />'6 <br />W <br />O <br />CD <br />Q UIL <br />O <br />� <br />`O <br />U <br />W <br />'*_ <br />CO <br />I <br />} <br />-� <br />L0 <br />Lr) <br />r(L <br />M N <br />O <br />Cc <br />H <br />DRAWN BY: FAE <br />VERSION: 5.0 <br />SHEET NAME <br />COVER SHEET <br />SHEET LP <br />SO. 1 -1 40 <br />