GENERAL STRUCTURAL NOTES: <br />1. ALL WORK SHALL CONFORM TO THE 2020 EDITION OF THE FLORIDA (INTERNATIONAL) <br />RESIDENTIAL CODE, 71h EDITION, AND APPLICABLE COUNTY CODE AMENDMENTS. STANDARDS <br />LISTED IN STRUCTURAL NOTE SECTIONS REFER TO THE VERSION AND EFFECTIVE DATE <br />IDENTIFIED IN THE REFERENCED STANDARDS CHAPTER IN THE GOVERNING BUILDING CODE <br />NOTED ABOVE. <br />2. THE STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS. SHOULD CONFLICTS <br />EXIST BETWEEN THE DRAWINGS AND THE STRUCTURAL NOTES, THE STRICTEST PROVISION <br />SHALL GOVERN. <br />3. THE 97RUCTURAL DRAWINGS FORM AN INTEGRAL PART OF CONTRACT DOCUMENTS, WINCH <br />INCLUDE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND CML/81TE DRAWINGS. <br />COORDINATE THE STRUCTURAL DRAWINGS WITH THE REIXUREMENTS SHOWN IN THE OTHER <br />COMPONENTS OF THE CONTRACT DOCUMENTS. <br />4. TYPICAL DETAILS AND OTHER SECTIONS/DETAILS APPLY TO CONDITIONS THAT ARE SIMILAR TO <br />THE CONDITIONS DESCRIBED IN THE SECTION84DETALLS, EVEN IF THEY ARE NOT SPECIFICALLY <br />REFERENCED ON THE PLANS. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS, METHODS SEQUENCES AND <br />PROCEDURES OF CONSTRUCTION, INCLUDING BUT NOT LMBTED TO TEMPORARY SHORING AND <br />BRACING. <br />6. DO NOT SCALE STRUCTURAL DRAWINGS. IF DIMENSIONS ARE OMITTED OR NOT CLEAR, <br />CONTACT THE ENGINEER. <br />7. CONSTRUCTION SHALL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF OSHA AND THE <br />LOCAL GOVERNING CODES, CURRENT EDITION, AND ALL REOUIIEMENTS SPECIFIED IN THE <br />CODES SHALL 13E ADHERED TO AS IF THEY WERE CALLED FOR OR SHOWN ON THE DRAWINGS, <br />THIS SHAD. NOT BE CONSTRUED TO MEAN THAT REQUIREMENTS SET FORTH ON THE DRAWING <br />MAY BE MODIFIED BECAUSE THEY ARE MORE STRINGENT THAN THE CODE REQUIREMENTS OR <br />BECAUSE THEY ARE NOT SPECIFICALLY REQUIRED BY CODE <br />S. THE ENGINEER'S SEAL APPLIES ONLY TO THE STRUCTURAL COMPONENTS ON THIS DOCUMENT. <br />ALL DIMENSIONS ARE TO BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS. ANY DEVIATIONS <br />OR DISCREPANCIES ON THESE PLANS MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF <br />THE ENGINEER OF RECORD. BACK CHARGES WILL NOT BE ACCEPTED, REGARDLESS OF FAULT, <br />WITHOUT PRIOR NOTIFICATION BY BUILDER WITHIN 4S•HOUR1I AND INVESTIGATION BY <br />FIELDSTONE <br />9. THE TERMS `CONCRETE SCREW AND UASONRY SCREW SHALL BE USED INTERCHANGEABLY <br />WITHIN THESE DRAWINGS. CONCIETEIMASONRY SCREWS AS GENERICALLY SPECIFIED WITHIN <br />THESE DRAWINGS SHALL REFER TO ONE OF THE FOLLOWING ACCEPTED MANUFACTURER <br />PRODUCTS. SIMPSON STRONG TIE MEN TURBO, GENUINE TAPCON, OR HLTI QUIK CON N. <br />1�C�1`► [�1�111_�1LT <br />1. BUILDING RISK CATEGORY <br />=I <br />2. VERTICAL LOADING <br />ROOF TOP CHORD LIVE LOAD <br />-20 PSF (REDUCIBLE) <br />ROOF TOP CHORD DEAD LOAD <br />-10 PSF <br />ROOF TOP CHORD DEAD LOAD (TILE) <br />=15 PSF <br />ROOF BOTTOM CHORD LIVE LOAD (w/ STORAGE) <br />20 PSF <br />ROOF BOTTOM CHORD LIVE LOAD (w/o STORAGE) <br />_-10 PSF <br />ROOF BOTTOM CHORD DEAD LOAD <br />-10 PSF <br />FLOOR LIVE LOAD <br />-40PSF <br />FLOOR LIVE LOAD (SLEEPING ROOMS) <br />-30 PSF <br />FLOOR DEAD LOAD <br />-15 PSF <br />DECKIBIILCONY LIVE LOAD <br />-40 PSF <br />EXTERIOR FRAME WAILS <br />w/OSB <br />=10 PSF <br />w/STUCCO <br />-15 PSF <br />W/SRICK <br />-45 PSF <br />INTERIOR WOOD WALL <br />-7 PSF <br />STARSAANDINGS <br />-40 PSF <br />SNOW CRITERIA: <br />GROUND SNOW LOAD ft <br />-0 PSF <br />SLOPED ROOF SNOW LOAD (Ps) <br />-0 PSF <br />EXPOSURE FACTOR (Ce) <br />-1.0 <br />IMPORTANCE FACTOR 09) <br />-1.0 <br />THERMAL FACTOR (Cq <br />-1.0 <br />ROOF SLOPE FACTOR (Cs) <br />-1.0 <br />SNOW LOADS ADJACENT VERTICAL PROJECTIONS & LOW ROOFS ADJACENT TO HIGH <br />ROOF ARE INCREASED FOR THE EFFECT OF DRIFTING <br />3. LATERAL LOADING <br />WIND CRITERIA: <br />BASIC WIND SPEED <br />-140 MPH <br />EXPOSURE CATEGORY <br />-C <br />INTERNAL PRESSURE COEFFICIENT <br />= +/• 0.18 (ENCLOSED) <br />SEISMIC CRITERIA <br />SITE CLASS <br />-D <br />SEISMIC DESIGN CATEGORY <br />-A <br />4. EARTH PRESSURE LOADING <br />ALLOWABLE SOIL BEARING CAPACITY <br />TOTAL LOADS (INCLUDING WIND 6 SEISMIC) <br />=2000 PSF <br />LATERAL EARTH EQUIVALENT FLUID PRESSURE <br />WALLS UNBRACED AT TOP <br />-40 PCF <br />WALL BRACED AT TOP <br />-55 PCF <br />5. GIARDRNLMANORNL LOADING: <br />ALL OUARDRAINANDRAILS SHALL MEET 200 USS (MINIMUM) CONCENTRATED FORCE APPLIED <br />IN ANY DIRECTION. IN -FILL COMPONENTS OF GUARDRAIL SHALL <br />MEET 50 PSF. THESE LOADS <br />ARE TO BE EVALUATED INDEPENDENTLY AND ARE NOT TO ACT CONCURRENTLY WITH ANY <br />OTHER LIVE LOAD. DEFLECTION OF GUARDRAIL SHALL MEET THE CRITERIA SET FORTH SYTHE <br />INTERNATIONAL CODE COUNCIL EVALUATION SERVICES nOC•ES) <br />AC 273 -'ACCEPTANCE <br />CRITERIA FOR HANDRAILS AND WARDS.' <br />FOUNDATION NOTES: <br />1. CONTRACTOR SHALL VERIFY ALL CONDITIONS, INCLUDING UNDERGROUND UTILITIES AND FIELD <br />MEASUREMENTS AT JOB SITE AND REPORT ANY DISCREPANCIES TO OWNERS REPRESENTATIVE <br />2. TOP OF SPREAD FOOTING ELEVATIONS NOTED ON PLAN ARE MINIMUM ELEVATIONS. IN ALL <br />CASES FOOTINGS ARE TO BEAR ON UNDISTURBED NATURAL SOILS OR ENGINEERED FILL HAVING <br />A MINIMUM NET ALLOWABLE BEARING CAPACITY OF 2000 PSF. <br />3. SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING. <br />FOUNDATIONS POURED AGAINST THE EARTH REQUIRED THE FOLLOWING PRECAUTIONS- SLOPE <br />SIDES OF EXCAVATIONS AS APPROVED BY GEOTEC HNICAL ENGINEER AND CLEAN UP <br />SLOUGHING BEFORE AND DURING CONCRETE PLANT. PROVIDE 6 MD. (MINIMUM) <br />POLYETHYLENE VAPOR RETARDER AGAINST SOILS WHERE CONCRETE IS TO BE PLACED; LAP ALL <br />EDON 61NCH (MNIMUMq AND SEA. WITH AOHESIVE. <br />4. WHERE FOOTING STEPS ARE NECESSARY, THEY SNAIL BE NO STEEPER THAN ONE VERTICAL TO <br />TWO HORIZONTAL U.N.O. <br />5. FOOTINGS SHALL BE CENTERED UNDER COLUMNS AND WALLS UNLESS SPECIFICALLY DETAIED <br />OTHERWISE ON THE DRAWINGS. <br />a. NO FOOTINGS OR SLABS SHALL BE PLACED ON OR AGAINST SUB -GRADE CONTAINING FREE <br />WATER, FROST OR ICE. SHOULD WATER OR FROST, HOWEVER SLIGHT, ENTER A FOOTING <br />EXCAVATION AFTER 8UB•G BADE APPROVAL, THE SUB-0RADE SHALL BE FIEEINSPECTED BYTHE <br />OEOTECHNIGAL ENGINEERTESTNO LABORATDRYAFTER RBmALof WATER OR FROST. <br />7. CONTRACTOR SHALL FURNISH ALL REQUIRED DE -WATERING EQUIPMENT NT TO MAINTAIN A DRY <br />EXCAVATION UNTIL BACKFILL IS COMPLETE <br />8. A GEDTECHNICJIL ENGINEER REGISTERED IN THE STATE OF WORK PERFORMED SHALL INSPECT <br />THE CONDInON AND ASSURE THE ADEOUACY OF ALL SITE PREPARATION, SUBORADES, FILLS, <br />BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS AND WAL& HE SHALL <br />SLOW REPORT TO THE ARCHITECT/ENGINEER DESCRIBING HIS INVESTIGATIONS OF ANY <br />NON -CONFORMING WORK <br />BACIFILUNG: <br />1. DO NOT PLACE BACKFILL AGAINST FOUNDATION WALLS - DESIGNED AS SUPPORTED AT TOP AND <br />BOTTOM - UNTIL BASEMENT LEVEL AND FIRST FLOOR SYSTEM ARE IN PLACE. SHORE AND/OR <br />BRACE WALLS AS REQUIRED IF BACKFILUNG OPERATIONS ARE TO BE CARRIED OUT PRIOR TO <br />PLACEMENT OF FLOOR SYSTEM. <br />2. WHERE BACKFILL 18 TO BE PLACED ON BOTH SIDES OF FOUNDATION WALLS, PROVIDE A <br />BALANCED BACKFILL AGAINST FOUNDATION WALLS TO EUMINATE LATERAL LOAD EFFECTS, OR <br />PROVIDE NECESSARY TEMPORARY LATERAL SUPPORT TO THE TOP OF THE WALL UNTIL <br />PERMANENT SUPPORT IS INSTALLED. <br />3. BACKFILL MATERIAL SHALL CONSIST OF CLEAN, WELL GRADE GRANULAR SOILS, FREE OF <br />ORGANIC MATERIAL AND BE COMPACTED TO 95%OF MAXIMUM DENSITY, AS DETERMINED BY <br />THE MODIFIED PROCTOR METHOD (ASTM 131557), IN LIFTS NOT EXCEEDING 8INCCHES. <br />CONCRETE NOTES: <br />1. STRUCTURAL CONCRETE HAS BEEN DESIGNED IN ACCORDANCE PER ACI 332'RESIDENTIAL <br />CODE REQUIREMENTS FOR STRUCTURAL CONCRETE'. <br />2. CONCRETE PRODUCTION AND PLACEMENT SHALL CONFORM TO THE REQUIREMENTS OF ACI 332 <br />'RESIDENTIAL CODE REQUIREMENTS FOR STRUCTURAL. CONCRETE' EXCEPT AS MODIFIED BY <br />STRUCTURAL REQUIREMENTS NOTED ON THE DRAWINGS. <br />3. CEMENT SHALL CONFORM TO AMU C160 *SPECIFICATION FOR PORTLAND CEMENT.' CONCRETE <br />SHALL BE NORMAL WEIGHT, UNLESS INDICATED OTHERWISE. <br />4. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C33 "SPECIFICATION FOR CONCRETE <br />AGGREGATES.' <br />5. REINFORCING SHALL CONFORM TO ASTM "15 GRADE 60. <br />S. REINFORCEMENT SHALL BE FABRICATED AND ERECTED ACCORDING TO THE ACI STANDARDS: <br />'DETAILS AND DETAUNG OF CONCRETE REINFORCEMENT', ACI 315 - AND 'MM UAL OF <br />ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES', ACI 315R <br />7. REINFORCING STEEL AND WELDED WIRE FABRIC SHALL BE PLACED WITH MINIMUM CONCRETE <br />COVER AND TOLERANCES AS FOLLOWS: <br />ILASMO NBa WITHIN UPPER 2/3 OF SLAB AND 314' MINIMUM COVER AT INTERIOR <br />CONDITIONS; 1-1/P MINIMUM COVER AT EXTERIOR CONDITIONS <br />OONCNM VVJNDATIOIB ASOW 5NM 3' <br />FOlBlm C� 1.1/2' (#5 REELAR OR SMALLER) 2' (#6 FEW OR LARGER) <br />TOt9M11C! +/-3/Y <br />S REINFORCING STEEL SMALL NOT BE CUT, BENT OR STRAIGHTENED IN THE FIELD UNLESS <br />APPROVED BY THE STRUCTURAL ENGINEER OR AS INDICATED ON THE DRAWINGS. <br />9. WELDING OF REINFORCING STEEL IS PROHIBITED (UNLESS SPECIFICALY DETAILED. WELDING <br />WHERE DETAILED SHALL CONFORM TO AWS DI A SPECIFICATION. <br />10. CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH AS FOLLOWS: <br />FOUNDATIONS & FOUNDATION WALLS: 2500 PSI <br />SLAB -ON -GRADE a CONCRETE BEAMS: 2500 PSI <br />11. CONTRACTOR SHALL TIE REINFORCING STEEL SECURELY IN PLACE PRIOR TO PLACING <br />CONCRETE AND PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THEIR POSITION WITHIN <br />SPECIFIED TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES. INSERTING DOWELS INTO <br />WET CONCRETE S NOT PERMITTED. ANCHOR RODS AND STEEL INSERTS SHALL BE SET BY <br />TEMPLATE TO WITHIN A U6' TOLERANCE IN ANY DIRECTION WITH MINIMUM EMBEDMENT AND <br />EXACT PROJECTION INDICATED ON THE DRAWINGS, PRIOR TO PLACING CONCRETE <br />I I HOOKED BARS SHALL BE STANDARD 90 DEGREE HOOKS PER ACI UNLESS NOTED OTHERWISE ON <br />THE DRAWINGS. MINIMUM LAP SPLICE SHALL BE CLASS B PER ACI 31S. LOCATION OF LAP <br />SPLICES SMALL BE AS INDICATED ON CONSTRUCTION DOCUMENTS, <br />13. DOWELS INTO FOUNDATION SHALL MATCH SIZE AND SPACING OF VERTICAL REINFORCEMENT AT <br />ALL COLUMNS, PIERS AND WALLS, UNLESS OTHERWISE NOTED. <br />14.CONTRACTOR SHALL OBTAIN APPROVAL PRIOR TO PLACING OPENINGS OR SLEEVES NOT SHOWN <br />ON THE DRAWINGS, THROUGH ANY STRUCTURAL MEMBER <br />15. ONE OF THE FOLLOWING CONCRETE SLAB ON GRADE CRACK CONTROL METHODS SHALL BE <br />USED (CONTRACTOR PREFERENCE): <br />• CONTROL JOINTS: SHALL BE FORMED, SAWED, OR TOOLED TO A 1' MINIMUM DEPTH WITHIN <br />24 HOURS OF CONCRETE PLACEMENT. MAXIMUM JOINT SPACING FOR UNREINFORCED SLAB <br />IS AS FOLLOWS: <br />3-IM SLAB: 8 FEET O.C. EACH DIRECTION <br />4' SLAB: 10 FEET O.C. EACH DIRECTION <br />• WELDED WIRE FABRIC (W.W.F) 8X6-WI AXWI A. WELDED WIRE FABRIC SHALL BE FURNISHED IN <br />FLAT SHEETS (ROLLS NOT PERMITTED) AND SHALL CONFORM TO ASTM M1064 AND HAVE A <br />MINIMUM SIDE AND END LAP OF 8INCHES. <br />• MICRO- OR MACRO. SYNTHETIC FIBER REINFORCEMENT <br />FIBER LENGTHS SHALL BE 1/2 TO 2.1/4' IN LENGTH. DOSAGE AMOUNT SHALL BE FROM 3/4 TO <br />3.0 POUNDS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SYNTHETIC <br />FIBERS SHALL. COMPLY WITH ASTM C1118. THE MANUFACTIURER/SUPPUER SMALL PROVIDE <br />CERTIFICATION OF COMPLIANCE WITH ASTM CI I16 WHEN REQUESTED BY THE BUILDING <br />OFFICIAL. <br />1&CONTROL JOINTS SHALL BE FURNISHED WITH A FULL-LENGTH KEYWAY CENTERED ON MEMBERS. <br />WHERE THE SIZE OF KEY IS NOT SHOWN ON THE DRAWINGS, THE KEY SHALL BE 25% OF THE <br />CROSS-SECTION DIMENSION OF THE MEMBER AND MINIMUM MITI! INCHES INTO THE FIRST POUR <br />OF CONCRETE. <br />17. PROVIDE POCKETS OR RECESSES IN CONCRETE WORK FOR COLUMNS AND BEAMS AS REQUIRED <br />EVEN IF NOT SHOWN ON THE DRAWINGS. PROVIDE CONCRETE FILL AFTER BEAM ERECTION. <br />1 S CURING OF CONCRETE SURFACES SMALL CONFORM TO ACI 306.1 'STANDARD SPECIFICATION <br />FOR CONCRETE DURING' AND ACI 308R'GUIDE TO CURING CONCRETE'. <br />MASONRY NOTES: <br />i. CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 530. 'BUILDING CODE <br />REQUIREMENTS FOR MASONRY 8TRJCTUEW AND SHALL BE CONSTRUCTED IN ACCORDANCE <br />WITH ACI 530.1, -SPECIFICATIONS FOR MASONRY STRUCTURES.- <br />2. CONCRETE MASONRY SHALL CONFORM TO ASTM COO AND HAVE A MINIMUM COMPRESSIVE <br />STRENGTH PM - 1,500 PSI U.O.N. MASONRY SHALL HAVE A TEXTURE SUITABLE FOR STUCCO <br />APPLICATIONS WHERE ARCHITECTURAL DRAWINGS INDICATE STUCCO APPLICATION. <br />3. CONCRETE MASONRY UNITS SHALL BE LAD IN RUNNING BOND. <br />4. MORTAR FOR ALL MASONRY SHALL CONFORM TO ASTM C270 WITH MINIMUM COMPRESSIVE <br />STRENGTH OF 21000 PSI. MORTAR BELOW GRADE SHALL BE TYPE M. ELSEWHERE MORTAR MAY <br />BE EITHER TYPE M OR 8 UNLESS SPECIFICALLY INDICATED OTHERWISE USE EITHER PORT AND <br />CEMENTAIME OR MASONRY CEMENT FOR MORTAL <br />5. GROUT SHALL CONFORM TO ASTM C476 WITH MINIMUM 28-DAY COMPRESSIVE STRENGTH OF <br />2,5W PSI. <br />& STEEL BAR REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE OD. <br />7. VERTICAL CELLS CONTAINING REINFORCING AND GROUT SHALL FORM A CONTINUOUS CAVITY, <br />FREE OF MORTAR DROPPINGS, <br />S. VERTICAL CMU WALL REINFORCING SHALL BE AS NOTED ON THE DRAWINGS. DOWELS TO <br />CONCRETE FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL REINFORCING UNLESS <br />NOTED OTHERWISE. REINFORCE CMU CORE AT CORNERS, EACH SIDE OF CONTROL JOINTS AND <br />EACH SIDE OF WALL OPENINGS WITH (1)45 CONTINUOUS VERTICAL REINFORCING BOLA <br />MASONRY NOTES (CONTINUED): <br />9. HORIZONTAL BOND BEAM AND VERTICAL REINFORCING SHALL BE CONTINUOUS U.O.N. LAP <br />SPLICE REINFORCING PER THE SCHEDULE OR USE MECHANICAL SPLICES ADEQUATE FOR 125% <br />OF SPECIFIED YIELD STRENGTH OF THE BAR LAP VERTICAL REINFORCEMENT WITH MINIMUM <br />DOWELS OF SAME SIZE AND SPACING THAT HAVE BEEN PREVIOUSLY INSTALLED IN THE <br />FOUNDATIONS. DOWEL EMBEDMENT IN CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF <br />THE CONCRETE NOTES. <br />BAR SIZE <br />LAP SPICE LENGTH <br />BEND DIAMETER <br />ACI HOOK <br />04 <br />2W <br />3' <br />10• <br />#5 <br />2S <br />3-3/4' <br />10' <br />#6 <br />34' <br />4.1/7 <br />11' <br />#7 <br />47 <br />S•1/4' <br />I <br />10. REINFORCING BARS SHALL BE HELD IN POSITION BY WIRE TIES OR OTHER APPROVED MEANS TO <br />ENSUE DESIGN LOCATION AND LAP. PLACE BARS AND LAP PRIOR TO GROUTING, <br />11. GRDUUTNG OF MASONRY WALLS SHALL CONFORM TO RECOMMENDED PROCEDURE FOR'LOW <br />LIFT GROUTING' OR'HIOH LIFT GROUTING' AS OUTLINED IN THE NCMA-TEK 3.2A - GROUTING <br />FOR CONCRETE MASONRY WALLS AND ACI 53WASCE 5 SPECIFICATION FOR MASONRY <br />STRUCTURES. GROUT LIFTS SHALL NOT EXCEED 5 FEET WITHOUT MECHANICALLY <br />CONSOLIDATED (VIBRATED) GROUT POURS. <br />12. LIFTS OF GROUT SHALL BE KEYED 4 INCHES INTO THE PREVIOUS COURSE OF MASONRY BELOW. <br />13. MASONRY BELOW GRACE SHALL BE GROUTED SOLID. <br />14. CONTRACTOR SHALL BRACE MASONRY WALLS TO RESIST WIND LOADS UNTIL FLOORS AND <br />ROOFS ARE IN RACE, AND THE MASONRY HAS REACHED 75% OF THE REQUIRED STRENGTH FM. <br />BRACING SMALL BE PROVIDED IN ACCORDANCE WITH OSHA- CONSTRUCTION SAFETY <br />STANDARDS FOR MASONRY WALL BRACING AND NCMA TEK 3­48 -'BRACING CONCRETE <br />MASONRY WALLS DURING CONSTRUCTION.' <br />WOOD FRAMING NOTES: <br />1. STRUCTURAL SAWN LUMBER, STRUCTURAL COMPOSITE LUMBER, AND CONNECTIONS HAVE <br />BEEN DESIGNED IN ACCORDANCE WITH THE'NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION.* (ND% <br />2. PLYWOOD HAS BEEN DESIGNED IN ACCORDANCE WITH 'PANEL DESIGN SPECIFICATION.' AND <br />SHALL CONFORM TO 'VOLUNTARY PRODUCT STANDARD PSI CONSTRUCTION AND INDUSTRIAL <br />PLYWYOOD.- <br />3. ORIENTED STRAND BOARD (OSB) SHALL CONFORM TO VOLUNTARY PRODUCT STANDARD P82 <br />PERFORMANCE STANDARD FOR WOOD -BASED STRUCTURAL -USE PANELS'. <br />4. ALL BEAMS AND HEADERS SHALL aE 0)-PLY U,N.D. <br />G. WOOD BILL PLATES AND WOOD WALLS SUPPORTED ON CONTINUOUS CONCRETE OR MASONRY <br />SHALL BE ANCHORED WITH 1/7 DIAMETER CAST -IN -PLACE ANCHOR BOLTS WITH T EMBEDMENT, <br />4- (MINIMUM) AND 12- WA IMUM) FROM Elm OF SILL PLATE(S), LOCATED WITHIN THE MIDDLE <br />THIRD OF THE SILL PLATE, WITH NUT AND 3WXII22H' WASHERS AT THE ANCHOR SPACING <br />BELOW. <br />MAXIMUM ANCHOR BOLT SPACING - V-W O.C. <br />REFER TO'PRE-APPROVED FIELD REPAIR NOTES' BECKON FOR ALTERNATE ANCHORAGE <br />APPROVALS. FOR OTHER ANCHORS NOT USTED, SUBMIT TO ENGINEER OR REOOID FOR <br />REVIEW. <br />S. ALL LUMBER IN CONTACT WITH EARTH, CONCRETE, OR MASONRY -AND WOOD BEAMS <br />POCKETING INTO CONCRETE OR MASONRY WALLS HAVING CLEARANCES LESS THAN 1/7 ON <br />TOP, SIDES, AND END(S) SHALL BE PRESSURE TREATED OR SEPARATED WITH AN IMPERVIOUS <br />MOISTURE BARRIER <br />7. STRUCTURAL SAWN LUMBER SHALL BE SPRUCE -PINE -FIR NO.1 UN0.2 OR BETTER U.N.O. WITH <br />BASE DESIGN VALUES: <br />F.- 875 PS�II�� �Fff���� 425 PSI FT - 450 PSI FC- 115O PSI FV- 135 PSI E- 14W KSI <br />WITH THE MDISTUli'E CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED im <br />S. BEARING AND EXTERIOR WALL STUDS SHALL BE CAPPED WITH DOUBLE (2X) TOP PLATES <br />INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT INTERSECTIONS. END JOINTS IN <br />DOUBLE MO TOP RATES SHALL BE OFFSET AT LEAST 24 INCHES AND SHALL BE NAILED WITH <br />NOT LESS THAN (6)4L162'X24/2- FACE NAILS ON EACH SIDE THE JOINT. DOUBLE (2X) TOP PLATES <br />OF EXTERIOR WALE AND INTERIOR LOAD BEARING WALLS SHOWN ON DRAWINGS SHALL BE <br />SOUTHERN YELLOW PINE NO.2 OR BETTER WITH BASE DESIGN VALUES: <br />Fe= 1100 PSI Frri�- 565 PSI FT- 675 PSI FC= 1450 PSI FV= 175 PSI E= 1400 K81 <br />WITH THE MOISTUA CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%, <br />9. STRUCTURAL COMPOSITE LUMBER SHALL CONFORM TO ASTM D 5458 WITH THE FOLLOWING <br />ALLOWABLE DESIGN STRESSES <br />NCR0111M LOLL PARALLAM FOL TRINwanym L>L <br />E - 2000 KSI E - IBM KSI E - 1300 KSI <br />Fe = 2600 PSI Fs = 2400 PSI Fe - 1700 PSI <br />I& FLOORR SHEATHING SHALL BE 2021NC H, APA RATED SHEATHING, 441N MIN., EXPOSURE 1. <br />INSTAL WITH THE LONG DIMENSION OR STRENGTH AXIS OF THE PANEL ACROSS SUPPORTS <br />AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. PANEL EDGES SHALL BE <br />TONGUE -AND -GROOVE. FLOOR SHEATHING SHALL BE GLUED AND NAILED TO SUPPORTING <br />MEMBERS. ADHESIVE SHALL MEET APA SPECIFICATION AFG.01, APPLIED IN ACCORDANCE WITH <br />THE MANUFACTURER'S RECOMMENDATIONS. PROVIDE 0.1 31N24/2"COMMON NAILS AT 61NCH <br />O.0 ALONG SUPPORTED PANEL EDGES AND 12 INCH O.0 AT INTERMEDIATE SUPPORTS. <br />11. FOR INTERIOR WALL HEADERS PROVIDE (1)-2X JACK STUD AND (I}2X KING STUD U.N.O. ON <br />DRAWINGS, <br />12. FOR EXTERIOR WALL HEADERS PROVIDE JACK STUD AND KING STUD PER CHART BELOW U.N.O <br />ON DRAWINGS: <br />WINDSPEED OF <br /><- 140 EXP. C <br />WALL HEIGHT <br />SIFT <br />OFT <br />IOFT <br />STUD <br />SIZE <br />HEADER SPAN <br />lFn <br />4 <br />IJ/IK <br />1J/IK <br />1JAK <br />a <br />INIK <br />1J/1K <br />1J/dt <br />a <br />IJ/1K <br />1J/1K <br />1J/3K <br />10 <br />14/2K <br />1J/2K <br />2*4 <br />12 <br />I.M <br />1J/3K <br />14 <br />1J/2K <br />1J/4K <br />q1J/4K <br />16 <br />1J13K <br />1J/4K <br />18 <br />IJ/3K <br />ENO <br />WINDSPEED OF <br /><- 140 EXP. C <br />WALL HEIGHT <br />OFT <br />9FT <br />10FT <br />STUD <br />SIZE <br />HEADER SPAN <br />4 <br />1J/1K <br />1JViK <br />1J/1K <br />6 <br />IJVIK <br />1JAK <br />IJ/1K <br />a <br />IJMK <br />1JAK <br />1J/IK <br />2xE <br />10 <br />IJ/1K <br />1J/1K <br />IJ/1K <br />12 <br />IJ/1K <br />1J/1K <br />1J/1K <br />14 <br />!NIK <br />1J/1K <br />1J11K <br />I', <br />1J/1K <br />1J/1K <br />1JIK <br />1s <br />K <br />1J/1K <br />1J/IK <br />13. WALLS SHOWN ON THE FRAMING PLANS ARE LOAD BEARING WALLS; WALLS NOT SHOWN ON <br />STRUCTURAL FRAMING PLANS ARE INTERIOR NON -LOADING BEARING PARTITION WALLS <br />14. LOAD BEARING WALLS SHALL BE CONSTRUCTED WITH 2X STUDS AT IV O.C. MAXIMUM UHO. <br />NON -LOAD BEARING PARTITION WALLS SHALL BE CONSTRICTED WITH 2X OR METAL STUDS (10 <br />GAL MIN.) ® 24. O.C. MAXOMIM. <br />15. STUD COLUMNS UNDER LOAD BEARING POINTS OF OIRDERSIBEAMS SHALL MATCH THE <br />GI1DER9EAMM PLY COUNT WTHN 1/2 TOLERANCE (2-PLY STUD) COLUMN MINIMUM). SOLID <br />BLOCK ALL ODDEP40EAMS THRU FLOOR SYSTEMS AND TO THE FOUNDATION. <br />16. WHEN NOT SHOWN ON DRAWINGS OR DETAILS, THE NAILING 804:MILE FOR WOOD FRAMING <br />ELEMENTS SHALL COMPLY WITH THE IRC TABLE R802.3(1). <br />17. FLOOR SYSTEMS ARE DESIGNED BY THE TRUSS ANOIOR WOOD 1-JOIST MANUFACTURER. <br />INSTALL PER MANUFACTURERS RECOMMENDATIONS, NOTES, AND DETAILS, FLOOR FRAMING <br />CONCEPT LAYOUTS SHOWN WITHIN THE DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY TO <br />DEPICT FLOOR SYSTEM -TO -WALL CONNECTIONS. CHANGES TO THE CONCEPTUAL FLOOR <br />LAYOUT SHOWN IS NOT PERMITTED WITHOUT A LETTER AND REVIEW FROM THE ENGINEER OF <br />RECORD. PREFABRICATED WOOD I- JOIST SHALL CONFORM TO ASTM D 51166, <br />PRE-ENGINEERED ROOF TRUSS NOTES: <br />1. ROOF TRUSS SHOWN ON STRUCTURAL DRAWINGS IN CONCEPTUAL ONLY TO ILLUSTRATE <br />TRUSS -TO WALL CONNECTIONS AND DOES NOT SERVE AS A ROOF TRUSS DESIGN. ROOF <br />TRUSSES SHALL BE DESIGNED AND MANUFACTURED IN CONFORMANCE FOR THE INDICATED <br />LOADS WITH ANSI/TPI 1 'NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD <br />TRUSS CONSTRUCTION.' FINAL PRE-ENGINEERED ROOF TRUSS FRAMING LAYOUT AND DESIGNS <br />TO BE BY ROOF MANUFACTURERS DELEGATED ENGINEER <br />2. ROOF TRUSSES SHALL BE DESIGNED FOR THE SUPERIMPOSED LOADS IDENTIFIED IN THE <br />DESIGN CRITERIA NOTES SECTION. <br />3. FOR PLANS FIELDSTONE AE S NOT CONTRACTED TO PERFORM TRUSS REVIEW ON, THE <br />CONTRACTOR IS RESPONSIBLE TO ASSURE THE DIRECT COMPLIANCE OF TRUSS <br />MANUFACTURER LAYOUT TO THESE DRAWINGS a VERIFY ALL TRUSS CONNECTORS ARE <br />SUFFICIENT TO WITHSTAND THE UPLIFT/LATERAL LOADS IMPOSED <br />4. TRUSS MANUFACTURER SHALL PROVIDE HANGERS AND CONNECTIONS ADEQUATE FOR LOADS <br />AT ALL TRUSS -TO -TRUSS, TRUSS -TO -BEAM, AND BEAM -TO -TRUSS CONNECTIONS. IF ANY TRUSS <br />CONNECTOR SHOWN IN THESE DRAWINGS CAPACITY HAS BEEN EXCEEDED, THE TRUSS <br />MANUFACTURER SHALL NOTIFY THE ENGINEER OF RECORD IMMEDIATELY. <br />5. REFER TO ARCHITECTURAL DRAWINGS FOR TRUSS SHAPE, OVERHANG, DIMENSIONS, SLOPES, <br />SPANS, DRAINAGE, BEARING WALL HEIGHTS, ETC. <br />S. THE POSITIONS, WEIGHTS, AND METHODS OF ATTACHMENTS OF ALL MECHANICAL UNITS, <br />ELECTRICAL FIXTURES, PLUMBING, FIRE SPRINN ER8, ETC SHALL BE INCLUDED IN THE DESIGN <br />OF THE TRUSSES BY THE TRUSS MANUFACTURER. SEE ARCHITECTURAL DRAWINGS FOR ATTIC <br />ACCESS SIZE AND LOCATIONS. <br />7. SUPERIMPOSED LOADS FROM SECONDARY FRAMING P.E. SOFFITS, PARAPETS, VALLEY FRAMING, <br />UPPER TRUSSES, ETC) SHALL BE INCLUDED IN THE DESIGN OF SUPPORTING TRUSSES. <br />S. CONTRACTOR TO PROVIDE TRUSS BRACING PER BC84B31N ADDITION TO PERMANENT BRACING <br />SHOWN ON THE TAM DESIGN PROVIDED BY THE DELEGATED TRUSS ENGINEER <br />PRE -APPROVED FIELD REPAIR NOTES: <br />1. MISPLACED DOWEL REPAIR THIS NOTE DESCRIBES ALTERNATES TO MITIGATE THE CASTING OF <br />REBAR VERTICAL REINFORCMENT AT AN INCORRECT LOCATION. <br />IF THE WALL HAS NOT BEEN BUILT: DRILL AND EPDXY #5 RESAR (36' LO.) INTO THE THICKENED <br />EDGE OF SLAB AT THE CORRECT LOCATION. A8 WALL IN CONSTRUCTED, LAP REBAR IN <br />ACCORDANCE NTH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 17 LAP AT <br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THEME BEAMISONO BEAM. COMPLETE <br />GROUTING OF WAIL <br />IF THE WALL HAS ALREADY BEEN BUILT: PRIOR TO GROUT PLACEMENT, OPEN THE WALL AT THE <br />CORRECT LOCATION APPROXIMATELY 16' M) x 4 (W) AT FLOOR LEVEL DRILL AND EPDXY #5 <br />REBAR (32- LO.) INTO THE THICKENED EDGE OF SLAB. LAP VERTICAL REINFORCEMENT IN <br />ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 12- LAP AT <br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAMBOND BEAM. COMPLETE <br />GROUTING OF WALL. <br />2. MISSING MSPLACED ANCHOR BOLT: SILL PLATE ANCHORAGE SOLUTIONS <br />INTO COICI <br />A 10x6' TITEN HO WITH 13/4• MINIMUM EDGE DISTANCE AND W MINIMUM END DISTANCE IS A <br />DIRECT 1:1 REPLACEMENT FORA 1/Y DIAMETER ANCHOR BOLT WITH T EMBEDMENT INTO <br />CONCRETE <br />A 1/7 THREADED ROD SET-XP EPDXY T EMBEDMENT WITH 13V4' MINIMUM EDGE DISTANCE AND <br />7-1/7 MINIMUM END DISTANCE IS A DIRECT 1:1 REPLACEMENT FOR A 112' DIAMETER ANCHOR <br />BOLT WITH T EMBEDMENT INTO CONCRETE <br />IMIOGIDUTRUAI0KOMMI Aft <br />A IM"" TITEN HO MTN 1.W V MINIMUM EDGE DISTANCE AND Y MINIMUM END DISTANCE AT W r <br />O.C. REPLACES A IIr DIAMETER ANCHOR BOLT WITH T EMBEDMENT AT e4Y O.C.; LIKEWISE A <br />1/27VS' TITEN HD WITH I V4- MINIMUM EDGE DISTANCE AND 8' MINIMUM END DISTANCE AT 2-8- <br />O.C. REPLACES A 1/2' DIAMETER ANCHOR BOLT WITH T EMBEDMENT AT W-W O.C.. <br />3. MLSSINGIMISPLACED TRUSS STRAP ANCHOR: REFER TO 'MISSED TRUSS STRAP REPAIR' DETAIL <br />WITHIN DRAWINGS. <br />FOR MISLOCATED TRUSS ANCHORS WHICH ARE GREATER THAN 1/8' BUT LESS THAN I41r FROM <br />THE FACE OF THE TRUSS, A SHIM SHALL BE PROVIDED AND NAIL LENGTH INCREASED TO <br />PENETRATE THROUGH BOTH PLYS OF MATERIAL (I.E. 3- LO. NAILS). WHEN GAP IS GREATER THAN <br />1-1/2', INSTALL NEW ANCHORS. <br />4. MASONRY WALL OVERHANGING SLAB <br />BLCCKQAIeBNIq iIORAp <br />< 5/8- NO REPAIR REO'D <br />5/8' < OVERHANG < 1-1/2' GROUT SOLID BOTTOM 3 COURSES OF AFFECTED WALL LENGTH <br />>1.1/Y CONTACT ENGINEER OF RECORD FOR REPAIR <br />5. NOTCHED TOP PLATES & STUDS REQUIRING REPAIR <br />AT 9PJM STRUCTURAL REPAIR IS REQUIRED AT STUDS WHEN A STUD IS NOTCHED TO A DEPTH <br />GREATER THAN 25% OF THE WIDTH IN BEARING WALLS, OR 40% IN NON -LOAD BEARING WALLS; <br />OR WHEN A HOLE 18 DRILLEDIBORED TO A DIAMETER EXCEEDING 40%OF THE STUD WIDTH IN <br />BEARING WALLS, OR 60% OF THE STUD WIDTH IN NON -BEARING WALLS. IF THE MAXIMUM <br />HOLEMOTCH SPECIFICATIONS ARE EXCEEDED THEN A STUD SHOE MUST BE INSTALLED. STUD <br />SHOE REPAIRS ARE AS FOLLOWS: FOR 2X STUD USE H892-SD81.5 WITH (I*1/4'X1.1/7 BOB <br />SCREWS. FOR MULTI -PLY 2X STUDS USE H882-'#'-SD83 WITH (12)-1/4W' SDS SCREWS, WHERE <br />#' CORRESPONDS TO THE NUMBER OF STUDS IN THE MULTI -PLY. <br />ATTOP RXM'. A HOLE, CUT, OR NOTCH THAT IS GREATER THAN 50% OF THE PLATE WIDTH IS <br />REMOVED FOR PIPING (EXCEPT WHEN THE SIDE OF THE WALL WITH THE NOTCH OR CUT IS <br />COVERED BY WOOD STRUCTURAL PANEL SHEATHING), OR THE PLATES ARE CUT THROUGH. THE <br />REQUIRED REPAIR IS A GALVANIZED 16-GAUGE METAL TIE THAT IS AT LEAST MA" WIDE AND <br />MUST BE FASTENED WITH (0)•1 SD NAILS ON EACH SIDE OF THE OPENING. <br />JURISDICTION SPECIFIC NOTES: <br />1. FOR PARTIALLY ENCLOSED AREAS, INCLUDING BUT NOT LIMITED TO LANAIS, PORCHES, AND <br />BALCONIES A 117 (MINIMUM) EXTERIOR GRADE SOFFIT BOARD WITH A CEMENTITIOU8 <br />KNOCKDOWN FINISH IS ACCEPTABLE PROVIDED THAT IT IS PAINTED MEETING THE <br />REQUIREMENTS OF ASTM COM TO GIVE THE CEILING WATER RESISTANCE THE SOFFIT BOARD <br />PRODUCT SHALL BE ATTACHED PER MANUFACTURER SPECIFICATIONS TO BE IN COMPLIANCE <br />WITH R70&1. <br />2. THE SOFFIT DESIGN PRESSURE IS AS NOTED IN THESE DOCUMENTS. WITH KAYCAN VINYL SOFFIT <br />INSTALLED IN ACCORDANCE WITH MANUFACTURERS REOUIRMENTS AND ICC-ES EVALUATION <br />REPORT ESR-1405 THE SOFFIT WILL COMPLY WITH R703.1. <br />C.O.A.# ARCHITECURE: <br />AA26002802 <br />C.O.E.# ENGINEERING: <br />29349 <br />0 IBRAHEM ELAYEB, PE <br />; of <br />P.E.# 91476 <br />■ BENJAMIN NIESE, PE <br />P.E.# 86025 <br />• <br />STATE���► ' , OREDI'.•'•• <br />i �� <br />02/ 2 aDATE <br />MIA goon <br />3400 Aubum Rd <br />Sufte 200 <br />Auburn Hits, MI 48326 <br />+1 248.622.4035 <br />FWdde <br />12906 Tampa Oaks Blvd. <br />Suite 150 <br />Tampa, FL 33637 <br />+1 81&48&3310 <br />www.flekhtonsee.aom <br />m <br />Zcl) <br />I Q <br />W G <br />GCC <br />Q l�L <br />2 <br />CL <br />Lc•) N <br />DRAWN BY: I FAE <br />VERSION: 5.0 <br />SHEET NAME <br />COVER SHEET <br />SHEET # <br />SO.1-1401 <br />