LOT 119 - PULSAR'OR'
<br />FL0.1.11
<br />SLAB PLAN'
<br />FL 1.12
<br />FLOOR PLAN'0'
<br />FL 1.12.1
<br />FLOOR PLAN OPTIONS
<br />FL 4.12
<br />SECTIONS
<br />FL 5.12
<br />ELEVATIONS'O'
<br />FL5.13.11
<br />ROOF PLAN'O'
<br />FL 6.12
<br />UTILITY PLANS'G'
<br />LOT 120 - PULSAR'LR'
<br />FL 0.1.8
<br />SLAB PLAN'L'
<br />FL 1.9
<br />FLOOR PLAN'L'
<br />FL 1.9.1
<br />FLOOR PLAN OPTIONS
<br />FL 4.9
<br />SECTIONS
<br />FL 5.9
<br />ELEVATIONS'L'
<br />FL 5J3.8
<br />ROOF PLAN'L'
<br />FL 6.9
<br />UTILITY PLANS'L'
<br />LOT 121 - PULSAR 'KR'
<br />FL0.1.7
<br />SLAB PLAN'IC
<br />FL 1.8
<br />FLOOR PLAN'IC
<br />FL 1.8.1
<br />FLOOR PLAN OPTIONS
<br />FL4.8
<br />SECTIONS
<br />FL 5.8
<br />ELEVATIONS'IC
<br />FL 5.13.7
<br />ROOF PLAN'IC
<br />FL 6.8
<br />UTILITY PLANS W
<br />LOT 1222 - PULSAR W
<br />SLA13 PLAN
<br />FL 1.1
<br />FLOOR PLAN'A'
<br />FL 1.1.1
<br />FLOOR PLAN OPTIONS
<br />FL 4.1
<br />SECTIONS
<br />FL5.1
<br />ELEVATIONS'A'
<br />FL5.13
<br />ROOF PLAN'A'
<br />FL 6.1
<br />UTILITY PLANS'A'
<br />LOT 123 - PULSAR 'MR'
<br />FL 0.1.9
<br />SLAB PLAN'M'
<br />FL 1.10
<br />FLOOR PLAN'M'
<br />FL 1.10.1
<br />FLOOR PLAN OPTIONS
<br />FL 4.10
<br />SECTIONS
<br />FL 5.10
<br />ELEVATIONS'M'
<br />FL 5./3.9
<br />ROOF PLAN'M'
<br />FL6.10
<br />UTILITY PLANS'M'
<br />LOT 124 - PULSAR 'B'
<br />FL0.1.1
<br />SLAB PLAN'B'
<br />FL 1.2
<br />FLOOR PLAN'B'
<br />FL 1.2.1
<br />FLOOR PLAN OPTIONS
<br />FL 4.2
<br />SECTIONS
<br />FL 5.2
<br />ELEVATIONS'B'
<br />FL 5.13.1
<br />ROOF PLAN'B'
<br />FL 6.2
<br />UTILITY PLANS'B'
<br />LOT 125 - PULSAR 'N'
<br />FL0.1.10
<br />SLAB PLAN'N'
<br />FL 1.11
<br />FLOOR PLAN Nr
<br />FL 1.11.1
<br />FLOOR PLAN OPTIONS
<br />FL4.11
<br />SECTIONS
<br />FL 5.11
<br />ELEVATIONS'N'
<br />FL 5.13.10
<br />ROOF PLAN'N'
<br />FL 6.11
<br />UTILITY PLANS'N'
<br />7-PLEX BUILDING - A
<br />A 0.1
<br />SLAB PERIMETER PLAN 7-PLEX
<br />0.11
<br />AO. 1 1
<br />SLAB PERIMETER PLAN 7-PLEX
<br />A 1.1
<br />FIRST FLOOR PLAN 7-PLEX
<br />A 1.1.1
<br />FIRST FLOOR PLAN 7-PLEX
<br />A 2.1
<br />SECOND FLOOR PLAN 7-PLEX
<br />A 2.1.1
<br />SECOND FLOOR PLAN 7-PLEX
<br />A 5.1
<br />ELEVATIONS 7-PLEX
<br />A 5.1.1
<br />ELEVATIONS 7-PLEX
<br />A 5.1.2
<br />ELEVATIONS 7-PLEX
<br />A 5.1.3
<br />ELEVATIONS 7-PLEX
<br />A 5.1.4
<br />ELEVATIONS 7-PLEX
<br />A 5.1.5
<br />ROOF PLAN 7-PLEX
<br />A 5.1.6
<br />ROOF PLAN 7-PLEX
<br />DETAIL SHEETS
<br />D-1
<br />DETAILS
<br />D-2
<br />DETAILS
<br />D-3
<br />DETAILS
<br />04
<br />DETAILS
<br />0-5
<br />DETAILS
<br />GENERAL NOTES:
<br />1. CONTRACTORS SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT SITE BEFORE CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE BUILDER FOR
<br />JUSTIFICATION AND/OR CORRECTION BEFORE CONTINUING WITH WORK. CONTRACTORS SHALL ASSUME RESPONSIBILITY FOR ERRORS THAT ARE NOT REPORTED TO
<br />THE BUILDER.
<br />2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES, REGULATIONS, AND FHANA MPS.
<br />3. ALL DIMENSIONS SHOULD BE READ OR CALCULATED AND NEVER SCALED.
<br />4. ALL FOOTINGS TO BE BELOW FROST LINE (SEE LOCAL CODE) AND MUST REST ON UNDISTURBED SOIL CAPABLE OF HANDLING THE BUILDING LOAD. CONSULT LOCAL
<br />ENGINEER FOR PROPER FOOTING AND REINFORCING SIZES.
<br />5. CONTRACTOR SHALL INSURE COMPATIBILITY OF THE BUILDING WITH ALL SITE REQUIREMENTS.
<br />6. IF BACKFILL EXCEEDS 4' AGAINST ANY FOUNDATION WALL, REINFORCE AS PER CODE.
<br />7. ALL WOOD, CONCRETE, AND STEEL STRUCTURAL MEMBERS SHALL BE OF A GOOD GRADE AND QUALITY AND MEET ALL NATIONAL, STATE, AND LOCAL BUILDING CODES
<br />WHERE APPLICABLE.
<br />8. ALL FOUNDATION AND STRUCTURAL MEMBERS SHOULD BE VERIFIED AND STAMPED BY AN ENGINEER IN THE STATE WHERE CONSTRUCTION IS OCCURRING DUE TO A
<br />WIDE VARIANCE IN LOCAL CODES, SOIL BEARING CONDITIONS, FROST LINE DEPTH, GEOLOGICAL AND WEATHER CONDITIONS, ETC.
<br />9. THE CONTRACTOR IS RESPONSIBLE FOR ADJUSTING AND VERIFYING ALL STRUCTURAL DETAILS AND CONDITIONS TO MEET ALL LOCAL CODES TO INSURE A QUALITY
<br />AND SAFE STRUCTURE.
<br />10. EXTERIOR FINISHES: INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C.R. -7TH EDITION (2020) RESIDENTIAL AND
<br />STM C 1063. ALL LATH AND RESISTANT MATERIAL, EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 1 1/2 INCH 11 GAUGE NAILS HAVING A 7/16 INCH
<br />HEAD, OR 7/8 INCH LONG 16 GAUGE STAPLES SPACED NO MORE THAN 6 INCHES, OR AS OTHERWISE APPROVED. THICKNESS OF TEXTURED FINISH OVER FRAME
<br />APPLICATION TO FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL AND ASTM C 926. WEEP SCREEDS SHALL BE A MINIMUM OF NO.26 GALVANIZED SHEET
<br />GAUGE CORROSION -RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES SHALL BE PROVIDED
<br />AT OR BELOW THE PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C 926. THE WEEP SCREED SHALL BE PLACED A MINIMUM OF 4 INCHES ABOVE
<br />THE EARTH OR 2 INCHES ABOVE PAVED AREAS. THE WEATHER RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. STUCCO APPLICATION AND CURING PER
<br />FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL OR IN ACCORDANCE WITH ASTM C 926.
<br />11. CHAPTER AND SECTIONS REFER TO F.B.C.R. - 7TH EDITION (2020). NOTE: ANY DIMENSION AND/OR CALLOUTS WITHIN THIS SET OF DRAWINGS REFERENCING LUMBER
<br />SIZES OR WALL THICKNESS ARE TO BE CONSIDERED "NOMINAL DIMENSIONS". ALL DIMENSIONS ARE TO ROUGH FRAMING UNLESS OTHERWISE NOTED.
<br />12. IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO ENSURE THAT ALL ELECTRICAL WORK IS IN FULL COMPLIANCE WITH N.F.P.A. 70, N.E.C. 2017, F.B.C.R. -
<br />7TH EDITION (2020), AND ALL APPLICABLE LOCAL STANDARDS, CODES, AND ORDINANCES.
<br />13. EGRESS: EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS TO EXTERIOR THROUGH A DOOR THE WINDOW
<br />MUST HAVE A MAXIMUM CLEAR OPENING HEIGHT OF 44" ABOVE FINISH FLOOR LINE OF THAT PARTICULAR ROOM.
<br />14. ASPHALT SHINGLES (IF APPLICABLE):
<br />WIND RESISTANCE OF ASPHALT SHINGLES - ASPHALT SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION R90?.
<br />ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR GREATER FOR ROOF SLOPES FROM TWO
<br />UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND LESS THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), TWO LAYERS OF UNDERLAYMENT COMPLYING
<br />WITH ASTM D 226, TYPE I OR TYPE II, ASTM D 4869, TYPE 11 OR TYPE IV OR ASTM D 6757 IS REQUIRED IN ACCORDANCE WITH SECTION R905.11. FOR ROOF SLOPES
<br />FROM FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12) AND GREATER, ONE LAYER OF UNDERLAYMENT COMPLYING WITH ASTM D 226, TYPE 11, ASTM D 4869, TYPE
<br />IV OR ASTM D 67571S REQUIRED IN ACCORDANCE WITH SECTION R905.11.
<br />15. TERMITE TREATMENT WILL BE DONE USING SENTRICON TERMITE BAITING STATIONS AND AND SHALL BE IN ACCORDANCE WITH FBC(R), SECTION R318 AND ALL
<br />RELATED SUB SECTIONS.
<br />16. UTILITY EASEMENT: USE OF THE SUBDIVISION FOR UTILITIES, INCLUDING BUT NOT LIMITED TO UTILITY EASEMENTS AS SHOWN ON PLAT, SHALL BE IN ACCORDANCE
<br />WITH THE APPLICABLE PROVISIONS OF THIS DECLARATION. THE DECLARANT AND ITS AFFILIATES AND ITS AND THEIR DESIGNEES SHALL HAVE A PERPETUAL
<br />EASEMENT OVER, UPON AND UNDER THE LOTS (INCLUDING BUT NOT LIMITED TO THE UNITS) AND THE COMMON AREAS (EXCLUDING THE CONSERVATION AREAS) FOR
<br />THE INSTALLATION, OPERATION AND MAINTENANCE OF UTILITY IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO ELECTRIC LINES, WATER AND SEWER PIPES,
<br />TELEPHONE LINES, COMMUNITY AND / OR CABLE TELEVISION AND SECURITY AND OTHER COMMUNICATION LINES, EQUIPMENT AND MATERIALS AND OTHER SIMILAR
<br />TELEVISION, RADIO AND SECURITY CABLES AND ALL FUTURE TECHNOLOGICAL ADVANCES NOT NOW KNOWN), FOR SERVICE TO THE LOTS AND OTHER PORTIONS
<br />OF THE SUBDIVISION, PROVIDED THAT NO OWNER'S NORMAL RESIDENTIAL USE OF SUCH OWNER'S UNIT SHALL BE INTERFERED WITH IN ANY UNREASONABLE
<br />MANNER.
<br />17. EXTERIOR WALL ENVELOPE: BUILDER IS RESPONSIBLE FOR PROVIDING AND MEETING ALL REQUIREMENTS OF SECTION 107.2.4 OF THE F.B.C. BUILDING BY PROVIDING
<br />ALL DETAILS LISTED UNDER THIS SECTION, INCLUDING BUT NOT LIMITED TO, THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ALL SUPPORTING
<br />DOCUMENTATION TO ENSURE THE WEATHER RESISTANCE OF THE EXTERIOR WALL ENVELOPE IS MAINTAINED.
<br />18. STUCCO CONTROL JOINTS TO BE INSTALLED PER ASTM C 1063-06 (7.11.4.1 THRU 7.11.4.4) AT FRAMED WALLS TO DELINEATE AREAS NOT MORE THAN 144 S.F. AND
<br />DELINEATE AREAS NOT MORE THAN 100 S.F. FOR HORIZONTAL APPLICATIONS. DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18 FT. IN EITHER DIRECTION
<br />OR A LENGTH -TO -WIDTH RATIO OF 2 1/2 TO 1. A CONTROL JOINT SHALL BE INSTALLED WHERE CEILING FRAMING OR FURRING CHANGE DIRECTION, AND WHERE
<br />EXPANSION JOINT OCCURS IN BASE EXTERIOR WALL. WALL OR PARTITION HEIGHT DOOR FRAMES SHALL BE CONSIDERED AS CONTROL JOINTS.
<br />19. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR
<br />DIRECTIONS, AND AROUND ROOF OPENINGS.
<br />APPROVE CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY
<br />D I I
<br />OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SH ALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL
<br />FINISH. APPROVED CORROSION -RESISTANT FLASHING SHALL BE INSTALLED AT ALL REQUIRED LOCATIONS PER R703.8.
<br />20. WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION
<br />INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW.
<br />21. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE GENERAL CONTRACTOR AS AN ATTACHMENT TO THIS PLAN SET AT
<br />THE TIME OF APPLICATION FOR PERMIT.
<br />NSPREPLACEMENT W HOUT MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR, AND IT REMOVING PERMANENT CONSTRUCTION
<br />OTHER APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED, OR REPLACED. A LEVEL
<br />WORKING SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES (762 MM) WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE.
<br />DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED A MIN. #26
<br />GAUGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE.
<br />FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3 INCHES (76 MM) ABOVE THE FINISHED GRADE AND SHALL ALSO
<br />CONFORM TO THE MANUFACTURERS INSTALLATION INSTRUCTIONS.
<br />AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDING
<br />COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE
<br />APPLICABLE PROVISIONS OF SECTIONS M1411.3.
<br />THIS PROJECT MUST COMPLY WITH: 2020 FLORIDA BUILDING CODE RESIDENTIAL - 7TH EDITION, FLORIDA FIRE
<br />PREVENTION CODE 7TH EDITION (THIS INCLUDES THE FLORIDA SPECIFIC EDITION OF 2018 NFPA 1 UNIFORM FIRE CODE,
<br />AND 2018 NFPA 101 LIFE SAFETY CODE). NFPA 10, 2018 EDITION, STANDARD FOR PORTABLE FIRE EXTINGUISHERS. NFPA
<br />13D, 2016 EDITION, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS IN ONE- AND TWO-FAMILY DWELLINGS
<br />AND MANUFACTURED HOMES. NFPA 70, 2017 EDITION, NATIONAL ELECTRICAL CODE. NFPA 72, 2016 EDITION, NATIONAL
<br />FIRE ALARM AND SIGNALING CODE. NFPA 90A, 2018 EDITION, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING
<br />AND VENTILATING SYSTEMS. 2020 FLORIDA BUILDING CODE ENERGY CONSERVATION, 7TH EDITION. 2020 FLORIDA
<br />BUILDING CODE MECHANICAL, 7TH EDITION. 2020 FLORIDA BUIDDING CODE PLUMBING, 7TH EDITION. 2020 FLORIDA
<br />j BUILDING CODE FUEL GAS, 7TH EDITION.
<br />i OCCUPANCY: RESIDENTIAL - R3 CONSTRUCTION TYPE: VB-PROTECTED, SPRINKLED
<br />\/^1 + C
<br />l J 0
<br />O
<br />G= 'I
<br />Q
<br />H
<br />V�
<br />ISSUE DATE:
<br />06.01.2023 FOR
<br />REVIEW
<br />REVISIONS:
<br />TYSON
<br />7-PLEX A
<br />LOTS 119-125
<br />PLAN 1386 PULSAR SF
<br />TOTAL BUILDING SF
<br />NAME
<br />AREA
<br />NAME
<br />AREA
<br />FIRST FLOOR
<br />588 SF
<br />FIRST FLOOR
<br />4858 SF
<br />SECOND FLOOR
<br />798 SF
<br />SECOND FLOOR
<br />6525 SF
<br />HEATED 1386 SF
<br />HEATED 11383 SF
<br />GARAGE
<br />226 SF
<br />GARAGE
<br />1771 SF
<br />PORCH
<br />32 SF
<br />PORCH
<br />249 SF
<br />PATIO / COV. PORCH
<br />1 80 SF
<br />PATIO / COV. PORCH
<br />640 SF
<br />UNHEATED 338 SF
<br />UNHEATED 2660 SF
<br />f
<br />These drawings are the
<br />property of Starlight
<br />Homes and are not to be
<br />utilized for construction, or
<br />copied in part or in whole
<br />without permission from
<br />the builder. © 2023
<br />Starlight Homes
<br />LAST REVISION
<br />%®%Zjs1k,..
<br />'t
<br />.ALL WORK SHALL COMPLY '�(d�•• o _ w
<br />CODES FLORIDA BUILDING WITH PREVAILING >C O� 1:
<br />NATIONAL ELECTRIC CODE CODE' W r N
<br />AND THE CITY OF ZEPHYR HILLS J r cc ORDINANCES p
<br />O
<br />.J
<br />4
<br />REVIEW DATE 'JUL 2 6 2023
<br />CITY OF ZEPHYRHIL
<br />PLAN F�71JLINER
<br />SHEETNO:
<br />T-1
<br />i