Laserfiche WebLink
OF VENT CALL. ELEV. 'O' <br />Name Area 1/300 RATIO AT HIGH & LOW 11150 RATIO AT HIGH & LOW <br />AREA 1 846 SF 1202.96 it? 1405.92 in2 <br />1 /150 RATIO: <br />1 /300 RATIO: <br />GENERAL CONTRACTOR SHALL VERIFY THE <br />AS AN ALTERNATE TO THE 1/150 RATIO LISTED, THE NET <br />NET FREE VENTILATION OF THE VENT <br />FREE CROSS -VENTILATION AREA MAY BE REDUCED TO 1/300 <br />PRODUCT SELECTED BY OWNER. VERIFY WITH <br />WHEN A VAPOR BARRIER IS HAVING A TRANSMISSION RATE <br />MANUFACTURER OF HIGH AND LOW VENTS TO <br />NOT EXCEEDING I -PERM INSTALLED ON THE WARM -IN - <br />BE USED FOR MINIMUM CALCULATED VENTS <br />WINTER SIDE OF THE CEILING. <br />REQUIRED. THE REQUIRED VENTILATION SHALL <br />BE MAINTAINED. PROVIDE INSULATION STOP <br />GENERAL CONTRACTOR SHALL VERIFY THE NET FREE <br />SUCH THAT INSULATION DOES NOT OBSTRUCT <br />VENTILATION OF THE VENT PRODUCT SELECTED BY <br />FREE AIR MOVEMENT AS REQUIRED BY THE <br />OWNER. VERIFY WITH MANUFACTURER OF HIGH AND LOW <br />BUILDING OFFICIAL. <br />VENTS TO BE USED FOR MINIMUM CALCULATED VENTS <br />REQUIRED. THE REQUIRED VENTILATION SHALL BE <br />ALL OVERLAP FRAMED ROOF AREAS SHALL <br />MAINTAINED. PROVIDE INSULATION STOP SUCH THAT <br />HAVE OPENINGS BETWEEN THE ADJACENT <br />INSULATION DOES NOT OBSTRUCT FREE AIR MOVEMENT AS <br />ATTICS IN THE ROOF SHEATHING (AS ALLOWED <br />REQUIRED BY THE BUILDING OFFICIAL. <br />BY THE STRUCTURAL ENGINEER) TO ALLOW <br />PASSAGE AND ATTIC VENTILATION BETWEEN <br />ALL OVERLAP FRAMED ROOF AREAS SHALL HAVE OPENINGS <br />THE TWO OR ISOLATED ATTIC SPACES SHALL <br />BETWEEN THE ADJACENT ATTICS IN THE ROOF SHEATHING <br />BE VENTED INDEPENDENTLY TO MEET 2020 <br />(AS ALLOWED BY THE STRUCTURAL ENGINEER) TO ALLOW <br />FLORIDA BUILDING CODE. <br />PASSAGE AND ATTIC VENTILATION BETWEEN THE TWO OR <br />ISOLATED ATTIC SPACES SHALL BE VENTED <br />PER DEVELOPER. AT ALL CANTILEVERED <br />INDEPENDENTLY TO MEET 2020 FLORIDA BUILDING CODE. <br />FLOORS. CANTILEVERED DECORATIVE <br />PROJECTIONS, AND ANY DOUBLE FRAMING <br />PER DEVELOPER, AT ALL CANTILEVERED FLOORS, <br />PROJECTIONS THAT ARE SEPARATED FROM <br />CANTILEVERED DECORATIVE PROJECTIONS, AND ANY <br />THE VENTING CALCULATIONS SHOWN ABOVE, <br />DOUBLE FRAMING PROJECTIONS THAT ARE SEPARATED <br />PROVIDE A CONTINUOUS 2" CORROSION <br />FROM THE VENTING CALCULATIONS SHOWN ABOVE, <br />RESISTANT SOFFIT VENT AT UNDERSIDE OF <br />PROVIDE A CONTINUOUS 2" CORROSION RESISTANT SOFFIT <br />FRAMED ELEMENT. <br />VENT AT UNDERSIDE OF FRAMED ELEMENT. <br />NOTES: <br />0 ALL ROOF DRAINAGE SHALL BE PIPED TO 0 TRUSS MANUFACTURER SHALL SUBMIT STRUCTURAL CALLS <br />STREET OR APPROVED DRAINAGE AND SHOP DRAWING TO THE BUILDER'S GENERAL <br />FACILITY. CONTRACTOR AND BUILDING DEPARTMENT FOR REVIEW <br />0 DASHED LINES INDICATE WALL BELOW. PRIOR TO FABRICATIONS. <br />0 LOCATE GUTTER AND DOWNSPOUTS PER 0 ALL PLUMBING VENTS SHALL BE COMBINED INTO A MINIMUM <br />BUILDER. AMOUNT OF ROOF PENETRATIONS. ALL ROOF PENETRATIONS <br />0 PITCHED ROOFS AS NOTED. SHALL OCCUR TO THE REAR OF THE MAIN RIDGE. <br />LOT 119 <br />I IU'-S" 1 9'-11" . 61 <br />ROOF PLAN 'O' <br />1/4" = 1 `0' AT 22"X34" LAYOUT 1/8" = 1 "0" AT 11" X 17" LAYOUT <br />a <br />w <br />CD <br />w <br />J E <br />O <br />s <br />Q <br />ISSUE DATE: <br />06.01.2023 FOR <br />REVIEW <br />REVISIONS: <br />These drawings are the <br />property of Starlight <br />Homes and are not to be <br />utilized for construction, or <br />copied in part or in whole <br />without permission from <br />the builder. © 2023 <br />Starlight Homes <br />LAST REVISION <br />4 <br />N <br />f�I <br />Ulev*` <br />r <br />cn <br />O <br />z <br />O <br />-' <br />a <br />J <br />LIL <br />O <br />Q <br />O <br />cr <br />W <br />J <br />a <br />SHEET NO: <br />FL 5.13.11 <br />