My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38092-38100 Elby Ln
Zephyrhills
>
Building Department
>
Building Plans
>
38092-38100 Elby Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:23:34 PM
Creation date
2/19/2025 8:03:11 AM
Metadata
Fields
Template:
Building Plans
Street #
38092-38100
Location
Elby Ln
Contractor
Starlight Homes
Building Plans - Permit #
6712-6715
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOF VENT CALC. ELEV. 'N' <br />Name Area 11300 RATIO AT HIGH 8 LOW 1/150 RATIO AT HIGH 8 LOW <br />AREA 1 648 SF 202.96 in0 405.92 inO <br />1 /150 RATIO: <br />1 /300 RATIO: <br />GENERAL CONTRACTOR SHALLVERIFY THE <br />AS AN ALTERNATE TO THE 1/150 RATIO LISTED, THE NET <br />NET FREE VENTILATION OF THE VENT <br />FREE CROSS -VENTILATION AREA MAY BE REDUCED TO V300 <br />PRODUCT SELECTED BY OWNER. VERIFY WITH <br />WHEN A VAPOR BARRIER IS HAVING A TRANSMISSION RATE <br />MANUFACTURER OF HIGH AND LOW VENTS TO <br />NOT EXCEEDING I -PERM INSTALLED ON THE WARWIN- <br />BE USED FOR MINIMUM CALCULATED VENTS <br />WINTER SIDE OF THE CEILING. <br />REQUIRED. THE REQUIRED VENTILATION SHALL <br />BE MAINTAINED. PROVIDE INSULATION STOP <br />GENERAL CONTRACTOR SHALL VERIFY THE NET FREE <br />SUCH THAT INSULATION DOES NOT OBSTRUCT <br />VENTILATION OF THE VENT PRODUCT SELECTED BY <br />FREE AIR MOVEMENT AS REQUIRED BY THE <br />OWNER. VERIFY WITH MANUFACTURER OF HIGH AND LOW <br />BUILDING OFFICIAL <br />VENTS TO BE USED FOR MINIMUM CALCULATED VENTS <br />REQUIRED. THE REQUIRED VENTILATION SHALL BE <br />ALL OVERLAP FRAMED ROOF AREAS SHALL <br />MAINTAINED. PROVIDE INSULATION STOP SUCH THAT <br />HAVE OPENINGS BETWEEN THE ADJACENT <br />INSULATION DOES NOT OBSTRUCT FREE AIR MOVEMENT AS <br />ATTICS IN THE ROOF SHEATHING (AS ALLOWED <br />REQUIRED BY THE BUILDING OFFICIAL <br />BY THE STRUCTURAL ENGINEER) TO ALLOW <br />PASSAGE AND ATTIC VENTILATION BETWEEN <br />ALL OVERLAP FRAMED ROOF AREAS SHALL HAVE OPENINGS <br />THE TWO OR ISOLATED ATTIC SPACES SHALL <br />BETWEEN THE ADJACENT ATTICS IN THE ROOF SHEATHING <br />BE VENTED INDEPENDENTLY TO MEET 2020 <br />(AS ALLOWED BY THE STRUCTURAL ENGINEER) TO ALLOW <br />FLORIDA BUILDING CODE. <br />PASSAGE AND ATTIC VENTILATION BETWEEN THE TWO OR <br />ISOLATED ATTIC SPACES SHALL BE VENTED <br />PER DEVELOPER, AT ALL CANTILEVERED <br />INDEPENDENTLY TO MEET 2020 FLORIDA BUILDING CODE. <br />FLOORS, CANTILEVERED DECORATIVE <br />PROJECTIONS, AND ANY DOUBLE FRAMING <br />PER DEVELOPER, AT ALL CANTILEVERED FLOORS, <br />PROJECTIONS THAT ARE SEPARATED FROM <br />CANTILEVERED DECORATIVE PROJECTIONS, AND ANY <br />THE VENTING CALCULATIONS SHOWN ABOVE, <br />DOUBLE FRAMING PROJECTIONS THAT ARE SEPARATED <br />PROVIDE A CONTINUOUS 7 CORROSION <br />FROM THE VENTING CALCULATIONS SHOWN ABOVE, <br />RESISTANT SOFFIT VENT AT UNDERSIDE OF <br />PROVIDE A CONTINUOUS 2' CORROSION RESISTANT SOFFIT <br />FRAMED ELEMENT. <br />VENT AT UNDERSIDE OF FRAMED ELEMENT. <br />NOTES: <br />0 ALL ROOF DRAINAGE SHALL BE PIPED TO 0 TRUSS MANUFACTURER SHALL SUBMIT STRUCTURAL CALCS <br />STREET OR APPROVED DRAINAGE AND SHOP DRAWING TO THE BUILDER'S GENERAL <br />FACILITY. CONTRACTOR AND BUILDING DEPARTMENT FOR REVIEW <br />0 DASHED LINES INDICATE WALL BELOW. PRIOR TO FABRICATIONS. <br />0 LOCATE GUTTER AND DOWNSPOUTS PER 0 ALL PLUMBING VENTS SHALL BE COMBINED INTO A MINIMUM <br />BUILDER. AMOUNT OF ROOF PENETRATIONS. ALL ROOF PENETRATIONS <br />0 PITCHED ROOFS AS NOTED. SHALL OCCUR TO THE REAR OF THE MAIN RIDGE. <br />LOT 115 <br />,� <br />ROOF PLAN 'N' <br />1/4' = i'-0' AT 22'X34' LAYOUT 1B' = 1'-0' AT 11' X 17' LAYOUT <br />k. co <br />o <br />= ,�• o� is • <br />U o < O* <br />•' S <br />rrffir�t*r pF�O����� <br />1➢! ch <br />fV <br />O <br />!V <br />O <br />J <br />i <br />ISSUE DATE: <br />06.23.2023 FOR <br />REVIEW <br />REVISIONS: <br />These drawings are the <br />property of Starlight <br />Homes and are not to be <br />utiized for construction, or <br />copied in part or in whole <br />without permission from <br />the budder. 0 2023 <br />Starlight Homes <br />LAST REVISION <br />LAST SAVED BY: <br />W <br />r <br />Q T Z <br />X LA z <br />W a <br />J <br />j r a <br />ELcn o <br />SHEET NO: <br />FL 5.13.10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.