Laserfiche WebLink
v- <br />(V <br />M <br />OWNER'S BATHROOM <br />SCALE: 3/8" =1'-0" <br />MIRROR <br />�.._. <br />-_ <br />N <br />TOWEL BAR <br />F <br />M <br />_ <br />� <br />ti <br />o <br />o <br />o <br />Oo <br />� <br />- <br />IIII <br />: <br />, <br />I � <br />L <br />Lii I <br />(2) 2x8 w/ 1/2" <br />FLITCH HEADER - <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL. <br />i <br />BATHROOM 2 <br />SCALE: 3/8" = V-0" <br />FILLED CELL LEGEND <br />0 CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />® FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />182X252 <br />S.H. <br />13 <br />20 X 38 J <br />181 X 3711 <br />S.H. <br />14 <br />20 X 50 J <br />18 17X 50 <br />S.H. <br />15 <br />20X63 <br />182X622 <br />S.H. <br />16 <br />20X72 <br />182X711 <br />S.H. <br />1H2 <br />271/4X26 <br />26X252 <br />S.H. <br />1H3 <br />271/4X382 <br />26x37i <br />S.H. <br />1 H4 <br />27 4 X 50 e <br />26 x 50 <br />S.H. <br />1H5 <br />27aX63 <br />26X621/2 <br />S.H. <br />1H6 <br />27JX72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />3617 X 25 1/2 <br />S.H. <br />23 <br />37 a X 38 J <br />36 2 X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 J <br />36 2 X 50 <br />S.H. <br />25 <br />37 Jq X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37JX72 <br />362X711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 2 WIDE <br />S.H. <br />32 <br />54 X 26 <br />5221 X 25 2 <br />S.H. <br />33 <br />54 X 38 8 <br />52 2 X 37 J <br />S. H. <br />34 <br />54 X 50 a <br />522 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 2 X 62 2 <br />S.H. <br />36 <br />54 X 72 <br />52 J X 71 2 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />rj <br />Ifo <br />DRYWALL <br />OF <br />Lo 5 Lo C? co <br />C0 co <br />D <br />CU) <br />O <br />(DLn <br />LU <br />-aE�„P:o <br />1 1/2" MIN. CLEARANCE <br />i� 17 1 1/4" TO 2" DIA <br />16 <br />HANDRAIL NO <br />i 15 LESS THAN 34" <br />i� 14 NOR MORE <br />i 13 THAN 38" ABV. <br />CONT. 12 TREAD NOSING <br />HAND RAIL 11 <br />10 METAL <br />HANDRAIL <br />BRACKET <br />BLOCKING AS <br />REQUIRED <br />F. FL. 1 <br />2x4 #2 SYP. P.T. THRUST <br />BLOCK W/(2)- 1/4"x 3 1/2" <br />TAPCONS @ 16"o.c. AND <br />3" FROM EA. END. TYP. <br />STAIR DATA: <br />18 RISERS @ T153" <br />42" KNEE WALL 17 TREADS @ 10" <br />WITH 1x8 CAP & TOTAL RISE = 10'-8 3/4" <br />TOTAL RUN = 14'-2" <br />CASING (AT 2nd i <br />FLOOR ONLY) i 3/4" PLYWOOD <br />i DECKING All <br />i <br />i <br />i <br />i <br />i <br />F. FL. <br />--- - - - - - - - - - - - - - - 18 <br />6 � <br />5 Co <br />2x STRINGERS <br />14'-2" <br />STAIR SECTION <br />SCALE: 1/4" = 1'4' <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 112" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />F. HANDRAIL DETAIL <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at aright angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding % inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />D1 <br />°P TYP. <br />i0 <br />18'4' <br />T-8" 13'-4" 1-4' <br />VERIFY <br />AC PAD LOCATION OF <br />A/C PAD <br />i. <br />HB <br />an I On <br />sm <br />solo 1111, <br />a.. OUTDOOR LIVING ONE <br />■■ 1 ■■11 <br />:II :II <br />ii iCONCRETE6830 <br />iiii <br />■■It• ■■ ■ <br />2'-8" <br />T-10" <br />T-10" <br />it <br />1 <br />C <br />6068 SGD <br />5-SH <br />I <br />REF 2468 BF <br />6'-7" <br />3'-2" <br />7'-11 " <br />I <br />0 <br />O <br />I 3 <br />- <br />Q <br />KITCHEN <br />DINING <br />9'-4" FLAT CLG. <br />o <br />9'-4" FLAT CLG. <br />I <br />TILE <br />TILE <br />SINK w/ <br />DISPOSAL D/W <br />r---J <br />aal I <br />I I <br />I <br />L---J <br />FLRG. LINE <br />_ <br />o� rm <br />2x8 WALL <br />of on cv nu <br />LO L-16" CNTR. AT 42" <br />1/2 WALL A.F.F. r <br />CAPPED I` <br />1 <br />UPS <br />d i CN <br />GREAT ROOM <br />9'-4" FLAT CLG. <br />CARPET <br />- 13'-8" <br />0 <br />GG <br />S3 C9 <br />2x6 WALL <br />4'-4" 2'-8" 6'-8" <br />*NO UPLIFT* <br />00 <br />- <br />Q <br />- - <br />S4 <br />00 <br />UJ co <br />FLRG._LINE_ <br />• _ 00 <br />H1 _ _ <br />TILE C71 <br />_J <br />LL <br />LL <br />U) I <br />FOYER <br />2868 <br />9'-4" FLAT CLG <br />TILE eo <br />00 <br />EDGE OF SLAB 2--T <br />W.~ <br />H. N <br />BEYOND WALL 9'-4" <br />� T.O.M. <br />O <br />T-0" <br />2'-6" <br />BUILDER TO <br />3068 O <br />PROVIDE <br />APPLIANCE <br />PROTECTION <br />0" 1'-8" <br />WHEN <br />REQUIRED PER <br />4'-8" 2'-0" <br />FBC <br />LO ENTRY <br />1-CAR <br />GARAGE 9-4 CLG. A.F.F. <br />9'-4" <br />FLAT CLG. g - CONCRETE <br />CONCRETE <br />CS ° <br />o <br />` <br />O� <br />F- r- <br />O <br />O 00 <br />iO <br />I------- <br />---------- in in <br />LINE <br />F 2nd STRY. ABV. I E ~ T <br />- 1 <br />I * <br />NOTE** I � <br />BLK. WALLS <br />ARE 8'-8" I o <br />>04 <br />TALL FO <br />"A" UNIT 5'-8" I O0 <br />o>04 <br />FROM <br />FRONT OF00 <br />q <br />C.o <br />I GARAGE <br />I - LO <br />K <br />@ <br />I H GARAGE <br />S4 HB <br />8'x7' <br />ARAGE DOOR <br />1'-8" <br />8'-0" V-8" <br />11 -4 7 -0 <br />18'-8" 8'-8" <br />T.O.M. T.O.M. 18'-4" <br />1ST FLOOR PLAN - UNIT-B 1516 <br />D� <br />TYP. <br />SCALE: Ya'"=1'-0" <br />140C <br />REV 10.1.20 CAB <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />2x6 <br />SYP #2 <br />16" O.C. <br />* WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN <br />STUDS WILL BE DOUBLE STUDS @ <br />@ 12" O.C.* <br />THIS IS ONLY USED WITH PLASTER <br />FINISH <br />** WALL SHEATHING 15/32" EXPOSI <br />REFER TO SHEATHING SCHEDULE <br />a <br />2nd FLOOR PLAN <br />✓irks°ag W Assist, Inc. <br />Plans �>?�:t/lever ;OI .plated and approved <br />for cornoijc:,,;c, v,,A,,n the-, 2020 7FFO 't <br />Edition by Dear_ Ann, N � ' ; P%',2300 <br />- UNIT-B 1516 <br />SCALE: Y4"=1'-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE"C" <br />O <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />CD <br />+28.3 / -37.0 <br />DE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET H SEE SN SHEET <br />M140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />e From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 518" <br />Type-X Gyp. Bd. or equivalent. <br />is Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will riot allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 664 S.F. <br />2ND FLOOR 849 S.F. <br />TOTAL 1513 S.F. <br />GARAGE 246 S.F. <br />LANAI 108 S.F. <br />ENTRY 98 S.F. <br />TOTAL SQ. FT. 1965 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />OG.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />' <br />• <br />{�CV <br />�4 <br />Qom,••'•*•,..,.•••°�• <br />v <br />