My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39926 Harman Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39926 Harman Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 9:35:26 PM
Creation date
2/19/2025 8:18:34 AM
Metadata
Fields
Template:
Building Plans
Street #
39926
Location
Harmon Grove Ct
Contractor
Lennar Home
Building Plans - Permit #
2030
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />WEATHER RESISTIVE <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />�--' <br />°' <br />CD <br />TEMPORARILY SECURE <br />BARRIER <br />DOOR ROUGH OPENING <br />WEATHER <br />SLOPE <br />_ <br />()% <br />RESISITIVE <br />0.3 in: 12.0 in <br />R703.1 General. Exterior walls shall provide the building with a weather-exterior wall envelope. The exterior wall envelope shall <br />V <br />BARRIERresistant <br />TAPE EXTERIOR <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHING::: ;i:ii :; 3/4"-1" BEAD OF CONSTR. <br />0.6 Cm : 30.5 Cm <br />( ) <br />include flashingas described in Section R703.4. <br />O O -�-' <br />L L <br />3 <br />BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER <br />SELF -ADHERED FLASHING <br />Cl)!� O OL <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND <br />!.'Z <br />WALL BY 6 IN. RETURN UP JAMB 6". USE LIQUID <br />EXTERIOR <br />R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water <br />Co -O <br />(ASSEMBLED <br />z <br />NAIL BRAND OR EQUAL WEATHER <br />3 PROOF CAULKING <br />CEMT. FIN. <br />within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means of <br />'� V Cn <br />2 <br />draining to the exterior water that penetrates the exterior cladding. <br />� U CZ Cl) <br />WEATHER <br />' <br />SELF -ADHERED FLASHING <br />BUILDING PAPER <br />RESISITIVE <br />z <br />O _-_ _0 <br />BARRIER <br />SEAL TOPS OF JOISTS 1 <br />WIRE LATH <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />O L O <br />UNDER DECKING <br />(SEE DETAIL WP07) SU BFLOOR <br />4iiiiot <br />- <br />approved water resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied horizontally, <br />C <br />O �' <br />SELF -ADHERED FLASHING <br />with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other <br />pp Y pp Y J pp <br />0 =+-_� co <br />CCS <br />approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No. 15 asphalt <br />O <br />Cn O > <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />RIM JOIST <br />felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building <br />•- O <br />O L <br />Cl) <br />1. Cut, fold up & temporarily secure weather <br />resistive barrier above header to allow for <br />1A <br />appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />Cn O <br />THESE DETAILS ARE GENERIC AND <br />C6 -I--• <br />flashing instaation <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />2 Self adhered flashingplus head flashing under <br />g 1 <br />weather resistive barrier <br />3. Fold barrier back head <br />1 <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based <br />sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The <br />BE USED. <br />weather resistive over <br />2 <br />flashing and seal with tape <br />2 <br />C <br />individual layers shall be installed independently such that each layer provides a separate continuous lane and an flashing Installed in <br />Y � Y Y p p p Y g( <br />accordance with Section R703A) intended to drain to the water -resistive barrier is directed between the layers. <br />Scale: NTS <br />SELF -ADHERED FLASHING <br />FLANGED WINDOW <br />W P01 <br />SELF -ADHERED FLASHING <br />W P02 <br />SELF -ADHERED FLASHING <br />W P03 <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />EXTERIOR DOOR WITH DECK - SECTION A <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />substantially nonwater-absorbing layer or designed drainage space. <br />EXTERIOR SHEATHING <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />EXTERIOR SHEATHING <br />3/4%1" BEAD OF CONSTR. INSTALL SELF -ADHERED <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD <br />NEEDED IN CORNERS ADHESIVE <br />ASPHALT ADHESIVE <br />THROUGH SELF -ADHERED <br />R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be applied <br />S/8" CEMENT <br />PLASTER <br />'»•:•• <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE <br />FLANGED WINDOW <br />FLASHING SELF -ADHERED FLASHING <br />shingle -fashion or in accordance with the manufacturers instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes <br />12 MIL DRYLOK CMU -MASONRY BLOCK <br />UP JAMB 6'. USE LIQUID NAIL BRAND (SEE DETAIL WP01) <br />OR EQUAL WEATHER PROOF CAULKING <br />used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to prevent the <br />g pp g pp <br />EXTREME <br />REFER TO TECHNICAL <br />��<`x;:.;; <br />SCORED <br />entryof water into the wall cavity or penetration of water to the building structural framing components. <br />Y p g 9 p <br />WINDOW <br />LETTER ON CHEMICAL `;:;' <br />COMPATIBILITY < <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />FASTENER <br />1 SEALANT AT <br />) <br />SELF -ADHERED F I <br />FLASHING <br />FLASHING, <br />SELF -ADHERED I <br />BEFORE FOLDING SCORE <br />9 Class Grad e proper joint expansion and <br />the building wall with a sealant complyingwith AAMA 800 or ASTM C 20 ss 25 a NS or greater for o <br />g 9 p p l p <br />4 SEALANT JOINT WINDOW BUCK TO <br />EXTEND A MINIMUM 6" <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN <br />MA 812 o her approved standard as appropriate for the t e of sea ant. Fluid -applied membranes used as <br />contraction, ASTMC1281, AA or dI <br />pptype <br />OUTSIDE EDGE OF ': ! ^'- .''r .'.n:' MASONRY <br />WINDOW BUCK <br />VERTICALLY FROM <br />BOTTOM OF <br />comply w' MA 714 The flashing shall extend o he surface of he exterior wall finish. Approved flashin s <br />flashing in exterior walls shall c I with AA fl II xt t t t <br />g p Y g pp g <br />2 <br />i':. ,,. ....a. )SEALANT JOINT <br />y : (r :'.'.:'.:.:'.':-::;;;, i:i;:;z;;,.. <br />'`: :.::::::::..: <br />THRESHOLD <br />� <br />shall be installed at the followinglocations: <br />5) SEALANT FROM x INSIDE EDGE OF <br />2 rii::c.;::::.:-:......; 3 ` "° <br />WINDOW FRAME ,.. `''`' WINDOW BUCK <br />ACROSS WINDOW BUCK ' • ' ••: � <br />' <br />SECTION -A (SEE DETAIL WP02) <br />. <br />AND EXTEND TO WINDOW FRAME <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />MASONRY ATTACHED <br />PER CODE <br />SELF -ADHERED FLASHING <br />C <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />6) TOOLED SEALANT REQUIREMENTS <br />c ': <br />2 <br />BEAD BRIDGING <br />following: <br />CLADDING AND WINDOW <br />FRAME <br />.. ' <br />SELF -ADHERED FLASHING `' <br />S <br />1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />3) SEALANT WINDOW FRAME T <br />WINDOW BUCK ALL THE WAY <br />NAILING FLANGE <br />1 <br />,�° <br />i <br />4 <br />manufacturers instructions, in accordance with the flashing manufacturers instructions. Where flashing instructions or details are <br />AROUND, INCLUDING SILL. <br />DO NOT FLASH OVER 2 <br />2 <br />SEAL TOPS OF JOISTS 1 <br />6 <br />not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />BOTTOM NAILING <br />� <br />UNDER DECKING <br />DETAIL WP07) 2 <br />7 <br />drainage. Openings usin an flashing shall incorporate flashing or protection at the head and sides. <br />g g p g p g <br />FLANGE <br />(SEE <br />1.2 1.2.1n accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />WP04 <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />WPO5 <br />SELF-ADHERED FLASHING <br />INSIDE CORNER <br />WP06 <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />FENESTRATION INSTALLATION AND INTERFACE <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />SHEATHING <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />1 <br />6.6.At wall and roof intersections. <br />Water Resistant Barrier <br />7.7.At built-in gutters. <br />JAMB, SILL AND HEAD DETAIL <br />Lath <br />APPROVEAPPROVEDDSHEATHING <br />Sheathing <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />HOUSEWRAP <br />PATCHDHEREDFLASHING <br />STRUCTALATH TWIN TRACK 2.5 <br />stuCCG <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />a ° A ° o <br />3/4" CEMENT PLASTER <br />�N <br />12 MIL (min) DRYLOK EXTREME <br />_ <br />° ° ° ° ° <br />APPROVED FLASHING TAPE <br />DOUBLE <br />- 2 <br />3 <br />° • <br />°. A. d ° <br />7/8" Cement Plaster <br />"V" SEALANT SOCKET WITH <br />JOIST <br />d d <br />° ° <br />TOOLED APPROVED SEALANT <br />SINGLE WOOD BEAM <br />°` ° " " ° <br />Foundation Wall, " <br />in accordance with 7/8" Cement Plaster <br />JOIST" EBELOW <br />1 SELF -ADHERED FLASHING <br />; <br />° ° <br />ASTMC926 in accordance with <br />SELF -ADHERED FLASHING <br />a ° < , d. <br />ASTMC926 <br />a °: <br />Felt backed metal <br />=� 2 <br />.' <br />v ° °° <br />s. lathe in accordance Felt backed metal <br />SELF -ADHERED SELF -ADHERED <br />3" MIN <br />4 <br />with ASTMC1063 lathe in accordance <br />FLASHING FLASHING <br />with ASTMC1063 <br />Building Paper <br />' Building Paper <br />�•',' ' 7/16" O.S.B. <br />' sheathing O.S.B. <br />SCS 06 02 WINDOW FIN INTERFACE WITH <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />WP07 <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />WPO$ <br />FOUNDATION WEEP SCREED <br />WPOg <br />,%,�` <br />sheathing <br />, : Metal sheathing <br />= <br />EXTRUDED SHOULDER <br />.. .. .... <br />.. Flashing <br />Weep Screed <br />SELF -ADHERED FLASHING <br />2x FRAMEWALL <br />Installed As Per <br />Manufact. Specs. <br />�i <br />PRODUCTSDETAILS <br />STRIP OF SAF LEGEND <br />SELF ADHERED FLASHING (SAF)---o-- <br />Maintain Stampede or similar <br />Bottom of bottom <br />(D <br />40 <br />TILE FINISH <br />cauk <br />Q <br />DRAINAGE PLANE WRB DRAINAGE PLANE (DP) WEATHER RESISTANT - - <br />BARRIER (WRB) <br />Weep Screed joint only <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />1/2" DUROCK <br />w <br />> <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />BOND BREAK WRB SELF FURRING (SF) LATH-J\�'�/� <br />1 1/2" to 2" <br />Above Roof Weep Screed <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Cn <br />I PLASTER ACCESSORY <br />Sheathing Installed As Per <br />SF LATH SHEATHING,'OSB', PLYWOOD, DENSGLASS ® <br />Manufact. Specs. <br />1'-4" PER PLAN <br />Z <br />> <br />Detail Instructions <br />Refer to the number marked as O in each detail that corresponds to the <br />1'-0" PER PLAN <br />WRAP DP WRB ONTO <br />I THE VERTICAL <br />1/2" Cementitious <br />Cement Plaster Decorative Finish <br />0 <br />L- <br />numbered items in the list of instructions below: <br />SURFACE To TOP OF <br />FLANGE AS AN AIR <br />in accordance <br />CL <br />BARRIER <br />with ASTMC926 •'•0'"°• All inside and <br />• ' <br />1. Install self -adhered flashing in order as shown by numbers <br />SLOPE <br />8 CMU <br />I 3-1/2" INCH FLANGE <br />over wood 2nd •• '� �'° •• outside corner will <br />• <br />floor <br />4� <br />2. Install flashing and weather resistive barrier to form water shedding <br />-- � <br />° <br />.•O <br />.•°• <br />need to be miter <br />�'° <br />O <br />laps <br />4" OR 8" CMU :____ a. a ° <br />- <br />I <br />. cut and caulked all <br />V <br />flashing can be substituted for building paper <br />3. Self-adheredh g g p p <br />(PER SEAT DEPTH) --- a <br />___ <br />Z Z <br />FRAMING <br />STRUCTURAL I G <br />'"�•,•. .••• butt joints need to <br />°. •o <br />O <br />4. Split the release paper using the ripcord (Split release on aemand, <br />FILL WITH GROUT =__ ° A.Q <br />a g <br />�� I� �� STRUCTURAL SHEATHING <br />. o. •o • becaulked using <br />• '�° " • Stampede or sim. <br />embedded in the adhesive layer) -for ease of installation and to <br />O <br />minimize scoring cuts <br />-_ ` .d . ° '. <br />a <br />THIS GAP IS RESULT OF <br />PLASTER STOP NATURAL SHRINKAGE. <br />STRIP OF SAF <br />caulk for all <br />L <br />5. Remove all release paper per standard installation instructions and <br />-Lu <br />--- Q ° <br />- --:a ° <br />2 � <br />DO NOT SEAL. <br />- - DRAINAGE PLANE WRB <br />CONTINUOUS BACKER <br />n <br />�+ <br />adhere to substrate using a square piece of flashing material (6" X 6" <br />-___ ` ; <br />U <br />ROD & SEALANT DRIP SCREED PLASTIC <br />Minimum) <br />SLOPED MUD BED =__ a ° ' e <br />2 Lu <br />ACCESSORY I I BOND BREAK WRB <br />'^ <br />v, <br />6. Fold as shown by arrows <br />--- . .� ° . <br />° <br />� <br />Q <br />SF LATH <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />=__ d :° o <br />U) � <br />fit tight to corner <br />VINYL SHOWER PAN -___- ° ° <br />= <br />A III <br />Note: <br />8. Mechanically fasten as necessary---� <br />. : ° . <br />SLOPE ° <br />- - - - - - - - <br />- - - <br />The building paper and metal lath must be <br />Cement installed over the top of the weep screed. <br />w <br />° --- <br />PLASTER STOP <br />A <br />Plaster <br />Q <br />a <br />CONTINUOUS BACKER ROD <br />over block <br />z <br />G <br />a <br />d <br />a <br />& <br />1 st floor <br />z <br />4 <br />CEMENTITIOUS FINISH <br />Q <br />J <br />SHEET N0. <br />SHOWER SEAT <br />WP 11 <br />SOFFIT/CANTILEVER <br />\/�/P 10 <br />WEEP SCREED DETAIL <br />WP1 <br />Y Y <br />SCALE: NOT TO SCALE <br />■ <br />
The URL can be used to link to this page
Your browser does not support the video tag.