39926 Harman Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39926 Harman Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 9:35:26 PM
Creation date
2/19/2025 8:18:34 AM
Metadata
Fields
Template:
Building Plans
Street #
39926
Location
Harmon Grove Ct
Contractor
Lennar Home
Building Plans - Permit #
2030
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br />ELECTRICAL DETAIL: <br />A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN <br />1 /411 = 1'-0" <br />F <br />SECOND FLOOR ELECTRICAL PLAN <br />1 /4" = 1'-0" <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED — <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR TH <br />INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />NFPA 72 2016 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017, <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A)BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES OR PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS FRO GARAGE MUST BE SERVED <br />BY SEPARATE BRANCH CIRCUIT THAT DOES NOT SUPPLY <br />OTHER OUTLETS. <br />5. CARBON MONOXIDE DETECTORS MUST BE AT LEAST 3 <br />FEET FROM BATHROOM DOOR. <br />NOTES: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR <br />SIDE -HINGE DOORS SHALL BE TESTED AND LABELED <br />WITH A PERMANENT LABEL PROVIDING TRACEABILITY TO <br />THE MANUFACTURER AND PRODUCT. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />DOOR <br />JAMB <br />INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />-SWITCH <br />4 1/2" <br />DUPLEX <br />OUTLET <br />TRIM ih <br />BASE u - <br />TRIM <br />NOTE: <br />ALL DIMENSIONS ARE FROM <br />ROUGH FRAMING <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />Sw STRUCTURED WIRE OUTLET <br />6- SWITCH AT 36 <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />-� PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />�B} CLG MNT PREWIRE - FIXTURE BY OWNER <br />�C} SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />NOTE: <br />3 TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />41 " USED IF 50W PAR30 NFL 6WHITE BAFFLE <br />C APPROVED BY <br />C RECESS CAN OR LED OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />�� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />C SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24- UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 - UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FFY24:�a 24" VANITY LIGHTING <br />F—= 36 � 36" VANITY LIGHTING <br />b 48 48" VANITY LIGHTING <br />0 EXHAUST FAN/LIGHT <br />EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />A CEILING RETURN AIR (W/ SIZE) <br />® A/C REGISTER <br />(T THERMOSTAT <br />® SECURITY PAD <br />IIn ELEC METER <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE <br />USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION <br />PURPOSES. <br />N L0" E <br />L -011 o <br />cYi ry <br />a7 Ua <br />c o <br />_O o <br />O S "m Q <br />U <br />co �N <br />o �M <br />000 <br />a <br />0 w0E- <br />QC'1 HQ wwYe <br />W LU w¢2 gzw Z <br />(j W of0� <br />aLLp¢w¢LE VOO <br />Q U O�ZLL°Zg°o <br />- p wOp200mZ � <br />_CLu �Woa0zpjD— Z <br />Z ¢~Wp9H75_gwp2U EL <br />< <br />oQ o 0 aQQq�¢ <br />�- <br />C <br />a <br />)zz <br />It <br />O <br />N <br />O O <br />1 CD <br />C <br />V <br />W <br />t� <br />0. 0 <br />�- m <br />z <br />LLJ p <br />> N <br />z 0 <br />J <br />w <br />J <br />O <br />N <br />oL" <br />k O <br />`M O <br />Q U M LLn <br />LL <br />F- d d <br />Q�000 <br />Z 3 ~ <br />J 00 <br />110 <br />V_ <br />(O M 00 O O O <br />O O O O O O O <br />N N N N N N N <br />O O O O 00 N M <br />N O r- O O <br />,- <br />i i O i <br />O O O N <br />0 0 0 0 0 <br />c <br />0 <br />T 0 0 0 0 0 0 <br />> (V M GU ti <br />I� <br />Z <br />Q <br />00 <br />T_1 <br />A6 <br />LAST PLOT DATE <br />Apr. 16, 21 <br />Z � <br />ZO <br />oLUW <br />Uj <br />UHF <br />�Q <br />a <br />LU�� <br />LU <br />CO 0Z <br />2 <br />O�w <br />Z <br />Z W <br />a�w <br />rn Z Z <br />y < 0 <br />U <br />1 ST & 2ND FLOOR <br />ELECTRICAL PLAN <br />A <br />I I Ii _r Ilk,1111,11AAt . - - - __-._ __.. - _.. _ -- - -ter-, - - <br />-, - 7 <br />