Laserfiche WebLink
PROVIDE (2) 6" X 14 GA (2 1/2" FLANGE) 50 KSI <br />BOX COLUMNS AT CORNERS AND ENDS OF WALLS. <br />SEE 7/S2L1 FOR HOLDOWN CONNECTION <br />EXISTING STOREFRONT <br />FRAMING PLAN f 1 \ <br />SCALE: 3/32" = V-0" \ S 1.1 <br />NOTES: <br />1. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, SLOPES, <br />ELEVATIONS AND OTHER INFORMATION NOT SHOWN. <br />2. MEANS AND METHODS OF CONSTRUCTION ARE THE RESPONSIBILITY <br />OF THE CONTRACTOR. <br />1000S162-54 JOISTS (10" STUD 1 5/8" <br />FLANGE X 16GA) AT 16" ON CENTER. <br />60OS162-54 (6" STUD 1 5/8" <br />FLANGE X 16 GA) STUDS AT 16" <br />ON CENTER <br />EXISTING DECK AND <br />ROOFING <br />CONTINUOUS L3x3x1/4 CONTINUOUS <br />ANGLE. ATTACH TO STUDS WITH <br />POWDER ACTUATED FASTENER. <br />MINIMUM PUDDLE WELD DECK TO <br />ANGLE AT 12" ON CENTER <br />EXISTING JOIST <br />40OS162-68 BRACES (4' STUD 1 5/8" <br />FLANGE X 14GA) AT 48" ON CENTER. <br />PROVIDE (6) S-12 SCREWS INTO 10" JOIST <br />L3x3x1/4 x 0'-5" <br />C8x11.5 x 24' LONG. <br />ATTACH TO CMU PIER <br />S ECTIO N JOIST AT HIGH PARAPETr2 WITH 3/8" 0 HILTI KWIK <br />HUS-EZ ANCHORS <br />SCALE: 3/4" = V-0" <br />STRUCTURAL GENERAL NOTES - FBC 2017 <br />1. GENERAL <br />a.Provide construction conforming to the 2017 Florida Building Code. Reference to other standards, <br />specifications, or codes means the latest standard or code published and adopted. <br />b.Material tests and inspections are required per Chapter 17 of the 2017 International Building Code. <br />Refer to the project Statement of Special Inspections for required tests and inspections. Special <br />inspection reports and a final report in accordance with Section 1704.1.2 of the 2017 Florida Building <br />Code at the time the building is approved for occupancy. <br />c. The structural general notes apply except where indicated otherwise on the drawings or in the <br />specifications. A detail shown for one condition applies for all like or similar conditions even though not <br />specifically indicated on the drawings. <br />d. Verify all existing conditions, dimensions, and elevations before starting work. Notify the Architect and <br />Structural Engineer of Record in writing of any discrepancy. <br />e. The Contractor is solely responsible for the design, adequacy, and safety of erection bracing, shoring, <br />temporary supports, and all other means, methods, techniques, sequences, and procedures of <br />construction. <br />f. Coordinate the structural contract documents with architectural, mechanical, electrical, plumbing, civil, <br />and all other consultants. Notify the Architect and Structural Engineer of Record in writing of any conflict <br />and/or omission. <br />g.Coordinate and verify floor and roof opening sizes and locations with architectural, mechanical, plumbing, <br />and electrical drawings. For additional openings not shown on the structural drawings refer to the <br />architectural and mechanical drawings. <br />h. Review of the submittals and/or shop drawings by the Structural Engineer of Record is only for general <br />conformance with the contract documents and does not relieve the Contractor of the responsibility to <br />review and check shop drawings before submittal to the Structural Engineer of Record. The Contractor <br />must review and stamp all submittals prior to submission. The Contractor remains solely responsible for <br />errors and omissions associated with the preparation of shop drawings as they pertain to member sizes, <br />details, and dimensions specified in the contract documents. Do not begin fabrication until shop <br />drawings are completed and reviewed by the Structural Engineer of Record. <br />L Do not make shop drawings using reproductions of the contract documents or referencing the contract <br />documents. <br />2. EXISTING CONDITIONS <br />a.Renovation of existing structures requires thorough coordination of the contract documents with existing <br />conditions. The Contractor must verify all relevant existing conditions, dimensions, and details prior to <br />beginning construction. Report any deviations from conditions or dimensions shown on the contract <br />documents to the Architect and Structural Engineer of Record for review of the design and possible <br />revision of the contract documents. <br />b. The nature of structural demolition and stabilization is inherently uncertain. The exact condition and <br />TOP/PARAPET capacity of each structural element cannot be verified prior to the commencement of work. As a result, <br />OIL it is imperative to report any discrepancies between the contract documents and actual field conditions, <br />17 -10 <br />as well as any element of questionable structural integrity immediately to the Architect and Structural <br />Engineer of Record for review. <br />c. No attempt has been made to define each specific structural element that must be removed, enhanced, <br />or replaced. It is the responsibility of the Contractor to review the condition of individual elements, <br />particularly rafters, joists, and structural deck boards, to determine which elements can be salvaged, <br />which elements must be replaced, and which elements are questionable. The Contractor should consult <br />with the Architect and Structural Engineer of Record to determine the appropriate procedure for handling <br />elements in questionable condition. <br />3. MASONRY <br />7/16" APA RATED 24/16 SPAN RATING OSB, EXPOSURE 1 WITH WITH NO. <br />8, TAPPING SCREWS WITH A MINIMUM HEAD DIAMETER OF 0.285 INCH, 6" <br />3/16 ON CENTER AT PANEL EDGES, 12" ON CENTER IN FIELD. PROVIDE STEEL <br />BLOCKING BEHIND ALL HORIZONTAL JOINTS AND FASTEN BOTH PANELS <br />TO BLOCKING 6" ON CENTER. <br />3/16 <br />3/16 <br />(2) 120OS250-97 (12" STUD 2 1/2" FLANGE X 12 GA) <br />BEAM. ATTACH TO PIER AT BEARING WITH (2) 5/8" HILTI <br />HY 70 WITH 5 5/8" EMBEDMENT. PROVIDE 8" END <br />DISTANCE FROM EACH END, SEE SECTION A -A <br />EXISTING CMU PIER <br />COMPONENTS & CLADDING PRESSURE SCHEDULE (NOTE 1) <br />EFFECTIVE <br />ROOF <br />ROOF OVERHANG <br />WALL <br />PARAPET <br />WIND <br />ZONE 5 <br />ZONE 5 <br />AREA <br />ZONE 1 <br />ZONE 2 <br />ZONE 3 <br />ZONE 1 OVHG <br />ZONE 2 OVHG <br />ZONE 3 OVHG <br />ZONE 4 <br />(NOTE 2) <br />ZONE 4 <br />(NOTE 2) <br />+16.0 PSF <br />+38.3 PSF <br />+38.3 PSF <br />+16.0 PSF <br />+16.0 PSF <br />+16.0 PSF <br />+35.1 PSF <br />+35.1 PSF <br />+87.7 PSF <br />+87.7 PSF <br />10 SF <br />-38.3 PSF <br />-64.3 PSF <br />-64.3 PSF <br />-61.1 PSF <br />-61.1 PSF <br />-96.8 PSF <br />-38.0 PSF <br />-46.8 PSF <br />-61.4 PSF <br />-70.2 PSF <br />+16.0 PSF <br />+36.1 PSF <br />+36.1 PSF <br />+16.0 PSF <br />+16.0 PSF <br />+16.0 PSF <br />+33.0 PSF <br />+33.0 PSF <br />+76.6 PSF <br />+76.6 PSF <br />25 SF <br />-37.1 PSF <br />-55.3 PSF <br />-55.3 PSF <br />-59.8 PSF <br />-59.8 PSF <br />-71 A PSF <br />-36.0 PSF <br />42.7 PSF <br />-57.3 PSF <br />-64.0 PSF <br />+16.0 PSF <br />+34.3 PSF <br />+34.3 PSF <br />+16.0 PSF <br />+16.0 PSF <br />+16.0 PSF <br />+31.5 PSF <br />+31.5 PSF <br />+68.2 PSF <br />+68.2 PSF <br />50 SF <br />-36.1 PSF <br />-48.4 PSF <br />-48A PSF <br />-58.8 PSF <br />-58:8 PSF <br />-51.4 PSF <br />-34.4 PSF <br />-39.6 PSF <br />-54.2 PSF <br />-59.4 PSF <br />+16.0 PSF <br />+32.6 PSF <br />+32.6 PSF <br />+16.0 PSF <br />+16.0 PSF <br />+16.0 PSF <br />+29.9 PSF <br />+29.9 PSF <br />+59.8 PSF <br />+59.8 PSF <br />100 SF <br />-35.1 PSF <br />41.6 PSF <br />41.6 PSF <br />-57.8 PSF <br />-57.8 PSF <br />-31.8 PSF <br />-32.9 PSF <br />-36.5 PSF <br />-51.1 PSF <br />-54.7 PSF <br />+16.0 PSF <br />+28.6 PSF <br />+28.6 PSF <br />+16.0 PSF <br />+16.0 PSF <br />+16.0 PSF <br />+26.3 PSF <br />+26.3 PSF <br />+56.2 PSF <br />+56.2 PSF <br />500 SF <br />-35.1 PSF <br />41.6 PSF <br />41.6 PSF <br />41.6 PSF <br />41.6 PSF <br />-31.8 PSF <br />-29.2 PSF <br />-29.2 PSF <br />43.9 PSF <br />43.9 PSF <br />NOTES: <br />1. (+) AND (-) SIGNES INDICATE PRESSURES ACTING TOWARD AND AWAY FROM THE BUILDING SURFACE, RESPECTIVELY. <br />2. PRESSURES APPLY V-10" FROM PROMINENT BUILDING CORNER IN EACH DIRECTION. <br />a.Provide concrete masonry conforming to the following standards: <br />ACI 530-11/ASCE 5-11/TMS 402-11, Building Code Requirements for Concrete Masonry Structures <br />ACI 530.1-11/ASCE 6-11/TMS 602-11, Specifications for Concrete Masonry Structures <br />b. Load bearing masonry walls are designed in accordance with Chapters 1 and 2 of ACI 530. <br />c. Brick veneer is designed in accordance with Chapter 6 of ACI 530. <br />d.Provide light -weight, hollow, load bearing concrete masonry units conforming to ASTM C 90 with a <br />compressive strength of masonry (f'm) of 1500 PSI and a net strength of 2000 PSI on the net <br />cross -sectional area of CMU determined in accordance with ASTM C 140. <br />e.Provide mortar conforming to ASTM C 270, Type M or S. Standard mortar bed joint thickness is 3/8" and <br />must not exceed 5/8". <br />f. Unless noted otherwise, provide grout for reinforced masonry conforming to ASTM C 476 with minimum <br />compressive strength of 2500 PSI. Pea gravel concrete with a minimum compressive strength of 3000 <br />PSI may be substituted for grout only with approval of the Structural Engineer of Record. <br />g.Unless noted otherwise, lay masonry units in running bond. <br />h.Provide ladder type horizontal joint reinforcing conforming to ASTM A 82. Unless noted <br />otherwise, place 9 gage or heavier, zinc coated ladder type horizontal joint reinforcing at 16" on <br />center. Lap horizontal joint reinforcing minimum 12". Use prefabricated 'L's and 'Ts at corners and <br />intersections. <br />i. For grouted walls, the maximum height of grout lifts must not exceed T-0". The maximum ungrouted <br />height of 8" or thicker CMU walls prior to grouting must not exceed 12'-0". Refer to Table 7 of <br />ACI 530.1 for the maximum ungrouted height of CMU walls thinner than 8". Consolidate and <br />reconsolidate grout in accordance with paragraph 3.5.E of ACI 530.1. Walls higher than T-0" must have <br />inspection holes at the base of the wall. <br />j. Lap vertical masonry wall reinforcing as follows: <br />#4 Bars 25" <br />#5 Bars 31" <br />k. Provide vertical control joints in all masonry walls not retaining earth. Unless noted otherwise on the <br />architectural drawings, place vertical control joints at three times the wall height, but not closer <br />than 25'-0" on center or farther than 50'-0" on center. <br />I. Unless noted otherwise, provide minimum (1) #5 vertical bar, grouted full height, at each side of <br />openings and at all corners and ends of walls, including both sides at ends of wall panels at vertical <br />control joints. <br />m. Unless noted otherwise, anchor sides and tops of masonry wall panels to the structure by dovetail <br />anchors, metal straps, or equivalent. <br />n.Place ties for brick veneers at not more than 16" vertically or 24" horizontally. <br />4. REINFORCED CONCRETE <br />a.Provide reinforced concrete conforming to the following standards: <br />ACI 301-11, Specifications for Structural Concrete for Buildings <br />ACI 318-10, Building Code Requirements for Reinforced Concrete <br />ACI 302.1R-04, Guide for Concrete Floor and Slab Construction <br />ACI 360R-10, Design of Slabs -on -Ground <br />b.Unless noted otherwise, provide normal weight concrete with 3000 PSI compressive strength at 28 days. <br />c. Provide 4% to 6% entrained air by volume in concrete permanently exposed to weather. <br />d.Provide concrete with a maximum water-to-cementitious materials ratio of 0.50. <br />e.Fully document and submit for review the proposed materials and mix design for all concrete. The <br />Contractor is responsible for obtaining the required design strength. All concrete test data must be <br />available at the job site. <br />f. The use of calcium chloride, chloride ions, or other salts is not permitted. <br />g.Place concrete at a slump of 5" f 1". <br />h. Unless noted otherwise, provide construction or contraction joints in slabs -on -grade such that the <br />maximum area between joints does not exceed 225 square feet with the length not exceeding twice the <br />width. <br />i. Chamfer or round all exposed corners a minimum of 3/4". <br />j. Detail concrete reinforcement according to ACI SP-66 detailing manual. Submit shop drawings for <br />approval, showing all fabrication dimensions and locations for placing concrete reinforcing and <br />accessories. Do not begin fabrication until shop drawings are completed and reviewed by the Structural <br />Engineer of Record. Unless specifically approved otherwise, detail all concrete walls and beams in <br />elevation. <br />k. Unless noted otherwise, provide reinforcing steel conforming to ASTM A 615, Grade 60. <br />I. Provide welded wire fabric (mesh) in flat sheets (rolls not permitted) conforming to ASTM A 185 and <br />ASTM A 82. Lap welded wire fabric a minimum of 6" at each splice. Place welded wire fabric 1" below <br />the top of slabs -on -grade. <br />m. Fiber reinforcing may be substituted for welded wire fabric in slabs -on -grade with the approval of the <br />Structural Engineer of Record. Provide fiber reinforcing conforming to ASTM C 1116, Type III. Use only <br />100% virgin polypropylene fibrillated fibers with a minimum of 1.5 pounds per cubic yard of concrete <br />unless otherwise directed by the fiber reinforcing manufacturer. <br />n. Unless noted otherwise, #4 @ 12" o/c in 8" thick slabs on grade. Place rebar 2" below the top of the <br />slab. <br />o.Tie all reinforcing steel and embedded items securely in place prior to placing concrete. Provide <br />sufficient supports to maintain the position of the reinforcement within specified tolerances during all <br />construction activities. "Sticking" dowels, anchor rods, or other embedded items into wet concrete is not <br />permitted. <br />p.Provide corner bars at all corners and intersections of all footings, beams, and walls. <br />q.Provide basic class "B" tension laps in all reinforcing bars indicated as continuous. <br />r. The placement of all reinforcing steel must be reviewed by a professional engineer registered in the state <br />of Florida or by a representative responsible to him (Ref: ACI 318, 1.3.1). <br />s. Unless noted otherwise, provide the following concrete cover on all reinforcing steel: <br />Concrete against earth (not formed): 3" <br />t. Do not place pipes or ducts with a maximum dimension exceeding one-third the slab or wall thickness <br />within the slab or wall unless specifically shown and detailed on the structural drawings. <br />u.Do not weld or tack weld reinforcing steel unless approved or directed by the Structural Engineer of <br />Record. Provide reinforcing steel conforming to ASTM A 706, Grade 60 where welding is approved or <br />directed. <br />5. STEEL DECKING <br />e.Provide steel deck of the type and gage indicated on the design documents. <br />f. Unless noted otherwise, provide steel decking primed and painted or with a G60 galvanized coating. <br />gAnstall steel decking in accordance with the manufacturer's recommendation. Do not install steel decking <br />until supporting joists are braced, bridged, and permanently fastened. <br />h.Install decking such that it is continuous over a minimum of three spans. <br />L Unless noted otherwise, fasten steel roof deck to supporting structure according to the following options: <br />(Roof exterior zones are areas of the roof within X'-X" of the roof perimeter. All other zones are <br />interior zones.) <br />1. Fasten to supports with #12 TEK screws in a 36/7 pattern at exterior zones and in a 36/3 pattern at interior <br />zones. Fasten side laps with #10 TEK screws at 6 inches on center at roof perimeter, (3) #10 TEK screws <br />per span at exterior zones, and (3) #10 TEK screws per span at interior zones. <br />2. Fasten to supports with 5/8" puddle welds in a 36/7 pattern at exterior zones and in a 36/3 pattern at <br />interior zones. Fasten side laps with #10 TEK screws or 5/8" puddle welds at 6 inches on center at roof <br />perimeter, (3) #10 TEK screws or (3) 5/8" puddle welds per span at exterior zones, and (3) #10 TEK screws <br />or (3) 5/8" puddle welds per span at interior zones. <br />6. COLD FORMED METAL FRAMING <br />a.Provide cold -formed metal framing conforming with the following standards: <br />NAS-01, AISI North American Specification for the Design of Cold -Formed Steel Structural Members <br />b.Provide studs, runner track, and associated accessories of the type and thickness indicated on the <br />drawings or as recommended by the manufacturer for the indicated application. <br />c. Provide studs, joists, runner track, and accessories manufactured of hot dip galvanized ASTM A 1003 <br />steel with the following yield strength: <br />33,000 PSI 33-mil (20 gage) and 43-mil (18 gage) members <br />50,000 PSI 54-mil (16 gage), 68-mil (14 gage), and 97-mil (12 gage) members <br />d.Provide minimum S-12 screws (cadmium or zinc coated). <br />e.Install all cold -formed metal framing in accordance with the manufacturer's recommendations. <br />f. Provide reinforcement for any member cut for the installation of plumbing or wiring such that the <br />member is of equal strength to the member prior to cutting. <br />g.Provide lateral bridging in load bearing walls consisting of 1 1/2" cold -rolled channels at 4'-0" on center <br />vertically. Insert channels through stud web holes and screw or weld to each stud using 1 <br />1/2" x 1" x 54-mil (16 gage) clip angles. Provide clip angles 1/4" less than the stud width. <br />h.Provide joist bridging at 8'-0" on center maximum. Install joist bridging in accordance with the <br />manufacturer's recommendations. <br />L Provide unpunched material for all joists and headers. <br />j. Provide solid blocking behind all horizontal panel joints of exterior wall sheathing and interior shear wall <br />sheathing. <br />k. Design of exterior walls subject to wind pressures is based on lateral bracing of stud flanges provided by <br />sheathing. If sheathing is not applied to both faces of the wall, provide bracing in accordance with SSMA <br />Technical Note No. 2, published March 2005. <br />7. OTHER COMPONENTS <br />a. Provide shop drawings for construction of all applicable specialty items including but not limited to <br />concrete pilings, curtain wall glazing systems, light gage steel framing, ornamental guardrails, guards, <br />handrails, pre-engineered wood trusses, skylights, and signage. Shop drawings must indicate the <br />required materials, sizes, and locations for all posts and pickets including anchorage at the base of the <br />posts. Shop drawings must be sealed by a professional engineer registered in the state of Florida. <br />b. Provide curtain wall glazing system shop drawings that clearly indicate the attachment to the structure <br />on all sides of the exterior glazing system required to adequately resist the applicable wind design <br />pressures. <br />c. The glazing Contractor must provide engineering calculations to document compliance with 2012 <br />International Building Code, Sections 2403.2 through 2303.4 for butt joined glazing. <br />d.The design of special connections between steel framing components (including but not limited to braced <br />end connections, moment -resisting connections, modified beam seat connections, and member splice <br />connections) not designed by the Structural Engineer of Record must be performed by a professional <br />engineer registered in the state of Florida. <br />V <br />F�1 <br />T� <br />V <br />Z <br />H <br />w o <br />V <br />~, <br />Iv` <br />t.iJ <br />0 <br />w LO CU <br />0 p N <br />IN�� <br />�U CD <br />wr r-)��0 <br />~�Q�Iz <br />V <br />VzvCY)U)_ <br />0 <br />N LLJ <br />N � cc <br />GCE <br />• <br />coo <br />d- <br />O <br />Z <br />Lu <br />m <br />Z <br />w <br />U <br />J <br />Q <br />O <br />J <br />LL <br />w <br />J_ <br />U) <br />Q <br />Q <br />07 <br />8. DESIGN LOADS <br />a. Live Loads: <br />7�36 <br />Roof 20 <br />PSF <br />b.Dead Loads: <br />Roof 5 <br />PSF <br />c. Wind Design Data: <br />Q <br />6. Ultimate Wind Speed (3 second gust): <br />146 MPH <br />Q <br />7. Wind Risk Category: <br />Category III <br />8. Wind Exposure: <br />Exposure B <br />Q <br />9. Internal pressure Coefficient: <br />f 0.18 <br />Q <br />10.Components and Cladding Pressures: <br />See Table <br />�OWN A.M. <br />*�*�MPy ••�C E N ss�� <br />N0 76433 SO <br />STATE OF 'QJ <br />,�.A� Q..``�'� <br />,�' F• S O R , O •��,,,,� <br />;/ONV `.�. <br />Ip11[I19 <br />CONTRACT DATE: <br />BUILDING TYPE: N/A <br />PLAN VERSION: N/A <br />SITE NUMBER: <br />STORE NUMBER: N/A <br />Zephyr Plaza <br />GALL BLVD <br />ZEPHYRHILLS, FLORIDA <br />Facade <br />STRUCTURAL <br />PLAN <br />11 - I M <br />I L <br />t4 t iry Simi <br />PLOT DATE: <br />