FLOOR BOX SHALL BE LISTED 4-PLEX OUTLET. <br />SPECIFICALLY FOR "SURFACE ° a <br />MOUNTED FLOOR" INSTALLATION d SEE PLAN & 1/E2 <br />(RE: N.E.C, 314.27(C)). DOUBLE GANG °,: ° `d a FOR TYPE REQUIRED. <br />GALVANIZED STEEL SURFACE MOUNTED <br />BOX (RACO #192 OR EQUIVALENT) 4 <br />WITH QUAD OUTLETS. PROVIDE WITH ° . �' °.. °. 4. <br />GALVANIZED STEEL FACE PLATE. 4. <br />d ° <br />a° <br />' °a a.d <br />° a.. q e <br />4°. <br />° ,. e ° ° . <br />d ee a d. TOP OF <br />CONCRETE FLOOR <br />a °. '.aq <br />PVC CONDUIT STUBBED <br />a.:a ° UP FROM BELOW FLOOR <br />4 4 <br />DIMENSION LINE IS TO d _ ad ° SLAB. <br />CENTER OF BOX. SEE ° <br />FLOOR PLAN. ° <br />SURFACE MOUNTED FLOORBOX <br />N.T.S. <br />TEMPORARILY DUCT <br />TAPE TO CLOSE END <br />OF 2" CONDUIT. <br />4L CEILING STRUCTURE <br />v IN OFFICE. <br />2" CONDUIT TO�.Z PUNCH 2" K.O. IN TOP <br />6" ABOVE CEILING �01F 4" DEEP 12%12" BOX <br />4" DEEP 12"x12" <br />PULL BOX WITH <br />SCREW COVER <br />FOR DATA. <br />WIRING BY <br />OTHERS. <br />2„ 2„ FACE BOXES TOWARD <br />OFFICE, TYPICAL <br />PUNCH (1) 2" <br />K.O. & (2) 1 " <br />K.O.'S IN BOTTOM <br />OF 4" DEEP, <br />co 12"x12" BOX. OFFICE WALL <br />I 2" CONDUIT <br />1CONDUIT <br />FLOOR <br />° d e..' ..e <br />d ° 6 ° <br />d ° _ e'-° <br />e . ° ° z e ..° a. <br />e e ° <br />° e a' ° ° <br />ROUTE THIS CONDUIT TO THESE CONDUITS AND BOX ARE <br />PHONE EQUIPMENT BOARD TO BE USED ONLY BY OWNERS <br />VOICE & DATA WIRING. <br />PVC IMC <br />CONDUIT TO COUNTERS AS <br />SHOWN ON PLAN <br />CONDUIT STUB -UP AT OFFICE 4 <br />N.T.S. E2 <br />NOTE: THE ILLUSTRATED MOUNTING <br />HEIGHTS ARE TYPICAL. SPECIAL <br />HEIGHTS ARE NOTED AS FOLLOWS �CEILING , <br />ABOVE COUNTER RECEPTACLE <br />RECEPTACLES <br />SWITCH 4"x4" BOX W/ RING <br />COVER FOR SINGLE <br />GANG FACE PLATE <br />COUNTER FOR TELEPHONE OR <br />DATA OUTLET. <br />IT - TT- - -1 <br />46" MAX. II I I II <br />II I I II ®® <br />COORDINATEII I 1 11 ®®- <br />W/COUNTER11 I I 11 <br />11 11 11 16" MIN. FINISHED FLOOR <br />r7 77 7 1 F <br />FLOOR BOX, 4-PLEX RECEPTACLE �/ <br />OR PHONE DATA BOXI <br />POWER/PHONE/DATA CONDUITS <br />UNDER TYPICAL OUTLET MOUNTING HEIGHTS <br />N.T.S. <br />PHONE/DATA BOX. SEE <br />DETAIL 5/E2, SIMILAR. <br />TYPICAL. <br />EACH BOX SHALL BE <br />SECURELY ANCHORED WITH <br />A MINIMUM OF (2) 3/16" <br />x 1-1/2" "TAPCON" <br />CONCRETE SCREWS <br />6' COUNTER <br />�4_-pt <br />MPM"_sCll \ PLP-12 PLP-7 <br />5 -0II <br />FIRE ALARM NOTE: <br />IN THE EVENT A MONITORED FIRE ALARM SYSTEM IS REQUIRED BY THE AUTHORITY HAVING <br />JURISDICTION, THE ALARM SYSTEM WILL BE CONTRACTED DIRECTLY BY THE ALARM SERVICES MANAGER, <br />LEIGH SIDES, WITH THE O'REILLY AUTOMOTIVE CORPORATE OFFICE. THE GENERAL CONTRACTOR SHALL <br />NOT PROCURE ANYONE TO INSTALL OR QUOTE THESE SYSTEMS UNLESS THEY HAVE BEEN ASKED TO <br />DO SO BY LEIGH SIDES. PLEASE CONTACT LEIGH SIDES ® 417-829-5712 IF A SYSTEM IS NEEDED <br />OR IF THERE ARE ANY QUESTIONS. <br />TELEPHONE <br />AND <br />COMPUTER DATA SYSTEMS: <br />A. <br />ELECTRICAL CONTRACTOR SHALL <br />PROVIDE AND INSTALL ALL TELEPHONE AND DATA CONDUITS. <br />B. <br />ELECTRICAL CONTRACTOR SHALL <br />VACUUM <br />OUT ALL CONDUITS TO REMOVE WATER. <br />C. <br />ELECTRICAL CONTRACTOR SHALL <br />PROVIDE <br />PULL -STRING IN EACH CONDUIT. <br />D. <br />OWNER SHALL PROVIDE AND INSTALL ALL TELEPHONE AND DATA WIRING. <br />KEYNOTES: <br />0 1" CONDUIT FOR DATA WIRING BY OWNER. FIRST STUB UP OF CONDUIT MUST BE IN COUNTER <br />FURTHEST AWAY FROM STOREFRONT. <br />0 ALTERNATOR TESTER, 120V. INSTALL (1) DUPLEX OUTLET ON ONE CIRCUIT, (2) SINGLE OUTLETS EACH <br />ON THEIR OWN CIRCUIT WITH #10 WIRE, (1) QUADPLEX OUTLET ON ONE CIRCUIT & A COMPUTER DATA <br />OUTLET BOX. SEE DETAIL 6/E2. <br />03 2" CONDUIT UNDERSLAB FOR OWNER INSTALLED PHONE SERVICE TO COUNTER. STUB CONDUIT UP <br />INSIDE COUNTER FURTHEST AWAY FROM STOREFRONT. <br />04 3" CONDUIT UNDERSLAB (FOR PRINTER CABLE ONLY), FROM UNDER COUNTER TO PRINTER LOCATION <br />(MAXIMUM 12" BELOW FINISHED FLOOR). <br />O CUT 3" CONDUIT (FOR PRINTER CABLE) FLUSH WITH FLOOR. <br />O FLOORBOX 4-PLEX ISOLATED GROUND RECEPTACLE. SEE DETAIL 5/E2. <br />O7 STUB UP 1" CONDUITS (FOR PHONE/DATA) INTO PHONE/DATA BOX. TYPICAL OF ALL COUNTERS. SEE <br />DETAIL 1 /E2. <br />O FLOORBOX 4-PLEX RECEPTACLE. SEE DETAIL 5/E2. <br />O FLOORBOX DUPLEX RECEPTACLE (FOR COKE MACHINE ONLY). SEE DETAIL 5/E2 SIM. <br />10 2" CONDUIT UNDERSLAB FOR OWNER INSTALLED PHONE SERVICE & DATA WIRING TO OFFICE #102. <br />1 1 1" EMPTY CONDUIT FOR FUTURE WIRING BY OWNER. STUB CONDUIT UP INSIDE COUNTER FURTHEST <br />AWAY FROM STOREFRONT. <br />12 INSTALL JUNCTION BOXES FOR ENERGY MANAGEMENT SYSTEM DOOR POSITION SWITCHES AND WIRE TO <br />CONTROLLING HVAC IN AREA OF BACK DOOR, PER EQUIPMENT SUPPLIER REQUIREMENTS. SEE SHEET <br />vs 1. <br />13 INSTALL FLOOR BOXES 0 THIS LOCATION BESIDE EACH OTHER. <br />14 3/4" PVC. <br />15 PHONE/DATA BOX. SEE DETAIL 5/E2 SIMILAR. <br />NOTE: ALL SWITCHGEAR (PANELBOARDS, <br />TRANSFORMERS, AND DISCONNECTS) <br />(EXCEPT FOR ROOFTOP UNITS) WILL BE <br />SUPPLIED BY THE OWNER (O'REILLY). <br />SWITCHGEAR SHALL BE DIRECT <br />ORDERED AND OR RELEASED FROM <br />THE ELECTRICAL EQUIPMENT <br />DISTRIBUTOR LISTED ON SHEET E3. <br />A WIRE TO INDICATED <br />ROOF <br />DEVICES WITH 20' <br />OF WIRING "WHIP" <br />(SHALL BE FLEX OR <br />�Z-PURLIN <br />TYPE MC CABLE). COIL <br />AND "ZIP TIE" WIRING <br />"WHIP" TO PURLINS AT <br />ROOF STRUCTURE. (FOR <br />FUTURE DROP BY <br />ZIP TIE TO BE <br />OWNER DOWN TO <br />CUT BY OWNER <br />INDICATED EQUIPMENT.) <br />®® AFTER FUTURE <br />WHERE A LOCATION HAS <br />qg CABINET & <br />MULTIPLE DEVICES, <br />SHELVING HAVE <br />LOCATE ALL DEVICES <br />I BEEN INSTALLED. <br />NEXT TO EACH OTHER <br />I <br />AT ROOF STRUCTURE. <br />_ <br />1 F -j <br />OWNER TO SECURLY STRAP <br />1 FUTURE <br />FLEX OR MC CABLE AND <br />I I I SHELVING <br />BOX TO SHELVING AND <br />t-4 BY OWNER <br />CABINET AS REQUIRED. <br />FUTURE DROP <br />1 <br />BY OWNERI <br />FUTURE CABINET <br />L- <br />BY OWNERI lr <br />FLOOR I <br />I I <br />WIRING WHIP <br />FROM CEILING 2 <br />N.T.S. E2 <br />BOTTOM SHELF <br />4-PLEX OUTLET WITH <br />AFTER COUNTERS HAVE BEEN ISOLATED GROUND. SEE <br />SET, THEN CONTRACTOR DETAIL 5/E2. TYPICAL. <br />SHALL CREATE OPEN HOLES <br />ABOVE EACH OUTLET FOR EACH BOX SHALL BE <br />ACCESS TO THE OUTLETS SECURELY ANCHORED WITH <br />AND THE JUNCTION BOX. A MINIMUM OF (2) 3/16" <br />x 1-1/2" "TAPCON" <br />^^ T^^ CONCRETE SCREWS <br />PLP-32 <br />PLP-13 VIA <br />PANEL "E" <br />COMPUTER <br />14A 20A/ 1 P DATA 20A/ 1 P 20A/ 1 P <br />NETWORK SWITCHJ_ <br />X <br />PRINTER <br />(2.5A) <br />AUTO IN <br />(14A) (14, <br />BVA POSI 160 (2.0A) <br />20A/1P <br />:) <br />PLUG-IN SEQUENCE FOR "TESTER" EQUIPMENT <br />1 <br />2" PVC SCHEDULE 40 CONDUIT FOR <br />PHONE SERVICE. STUB UP CONDUIT <br />12" A.F.F. INSIDE BUILDING. <br />TELEPHONE EQUIPMENT LOCATION. <br />INSTALL 4'Wx8'Hx3/4" PLYWOOD <br />1'-0" A.F.F. SEE DETAIL 2/E2. <br />PLP-27 <br />PLP-15 VIA <br />PANEL "E" <br />POSITION E <br />DEDICATED CIRCUIT FOR FUTURE USE. (LOCATE DUPLEX <br />OUTLET 9'-6" A.F.F. TO BOTTOM WITHIN HUBBELL <br />DEEP SINGLE GANG HINGED COVER #RW57350). <br />RELIANCE OUTDOOR <br />RECEPTACLE. WIRE TO <br />PANEL "E." SEE SHEET E3. <br />INSTALL HOFFMAN #ASE12X12X4 <br />BOX 0 THIS LOCATION FOR-/ <br />STORAGE OF GENERATOR CORD. <br />BOTTOM SHELF <br />- - - - - AFTER COUNTERS HAVE BEEN <br />SET, THEN CONTRACTOR <br />SHALL CREATE OPEN HOLES <br />ABOVE EACH OUTLET FOR <br />ACCESS TO THE OUTLETS <br />AND THE JUNCTION BOX. <br />T� rICOUNTER BY <br />OWNER, TYPICALr^ <br />PLP-30 <br />PLP-1 1 _�w- PLP-26 <br />8 �/-----PHONE DATA----- - -•PHONE DATA---- ----� -PHONE/DATA- - �-----j DATA1� <br />13 6 15------------ - 6 / 6 5 15 � 6 ��6 3 15 � 6 <br />— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -------------------------- <br />FLOOR MOUNTED RECEPTACLES UNDER COUNTERS <br />FRONT DOOR N.T.S. E2 <br />x <br />CRIMPER, 120V, L <br />W/ 1 HP MOTOR. f <br />PLP-18 <br />eo0 ioi <br />too <br />DATA <br />OUTLET <br />101 <br />Rol <br />toe ioi <br />�,� <br />BOX <br />N.T.S. <br />SEE SHEET SU1 FOR <br />CONTINUATION <br />VENSTAR SURVEYOR 4 <br />SYSTEM LOCATION. E1 2 <br />LATHE, 120V, W/ 1 HP MOTOR. <br />INSTALL RECEPTACLES SHOWN & <br />CIRCUIT W/ #10 WIRE. <br />I <br />4"x4" BOXES SHALL BE HUNG <br />® 60" A.F.F. TO BOTTOM OF <br />BOX. CONDUIT SHALL EXTEND <br />MAX. OF 5' AIBOVE BOX. <br />A 4"x4" DATA <br />I- OUTLET BOX. <br />T <br />PLP-20 PLP-14 VIA <br />PANEL E <br />POSITION A 4"x4" DATA <br />/ r-- SEE DETAIL 4/E2. I OUTLET BOX. <br />LCklECK L - - I I �., ��., I �,N� RI PLP-16 � 103 <br />rHE IN L 1N_STALL1F; R Ir7 <br />` 6 " �FFICE B EAK MP-15,17 <br />AIL-----� PLP-9 ----- PLP-8 ----- 1�R�PLP-22 <br />- MP-5 rt - �Lp <br />D ° 1PLP-1 MP-41I L_ II -97- P-19- <br />1 WATER <br />PARTS AREA "C" MP-13 \ r - - - GFI BREAKER MP-1 1 COOLER, 2 <br />\ 105 \ I uPoR <br />\ I-- -- -- -- --� JMDP-6 <br />RADIATORS ABOVE _ _ <br />r B— RACK BULK RACK 2 TEST <br />x4" DATA <br />MP-1 \ A OUTLET BOX. <br />CUTOFF SAW, 120V. INSTALL- - - - �L �9- -L - 1 - - I I I I I I <br />RECEPTACLE SHOWN & PLP-5 <br />HYD T CIRCUIT W/ #10 WIRE. _ T - - - - 1 MP-21 <br />_ -MMp-3 , MP-?31 <br />GRAVI FEED.O L RACK - - --LRACI�- -1U <br />_ 6 (2) OUTLETS ON 11 I I I I I I <br />PLP-41 EACH CIRCUIT. I1 <br />RTIS I REA I B7 <br />m\ I MDP-4 11 <br />I <br />J �.---1 <br />-1 ��r✓ I- - - - I/ 1 II I I I 11 'Qj� <br />SuPo <br />UPO _ \ � I I UPO -� <br />MP-13 I It L - - J - <br />MDP-3- _ _ _ \ 6 j 7 MDP-5 <br />-4 I MP-13 <br />-- -- -- -- -- <br />I- - <br />PARTS AREA "A' I E2 i 1 I 1 <br />r — I— r — — — — — — r — — I — — <br />1 L1111 <br />III- I r- /-4 VIA <br />LF = _ _ _ _ T = h I 1 10' EMERGENCY- <br />_I 4 I - PANEL "E" - -- <br />4 - POSITION C- - - <br />7 <br />I I I 5 <br />l _ _ I <br />I L I ILI' <br />II 6, <br />- - - - _OF PRINTER - <br />1 46 F- — -- — <br />1 " <br />—�—� ——�—�— I—J 6 r--- _I$— — — — — <br />Lill I- ( 0- <br />N- - - <br />INSTALL JUNCTION BOX FOR 110 <br />VENSTAR SURVEYOR SYSTEM MP-41 6 - <br />f DOOR POSITION SWITCH, I U 7 1 <br />I PER EQUIPMENT SUPPLIER I 6" 9 <br />REQUIREMENTS. <br />I _ _ J �-10�� III I I I I I I I <br />8 VM I L L, L L I L J I J <br />DIMENSION FROM _ _ DIMENSION FROM <br />COLUMN LINE COLUMN LINE <br />MOUNT RECEPTACLE IN CEILING FOR "OPEN" SIGN. CIRCUIT RECEPTACLE TO <br />NEAREST LIGHTING CONTROL PANEL CONTROLLED LIGHTING CIRCUIT. "OPEN" <br />SIGN CAN ALSO BE OPERATED BY INTEGRAL PULL CHAIN. SEE SHEET E1. <br />POWER PLAN <br />z <br />SCALE: 1 /8" = 11-0" <br />TRUE NORTH <br />T 4 <br />:❖:❖ ws i <br />— riiy <br />o.•a <br />An <br />r♦ INSTANTANEOUS <br />HEATER, LOCATED <br />BELOW LAVATORY. <br />REFER TO DETAIL 1/P1. <br />L <br />DIMENSION FROM <br />COLUMN LINE <br />c� <br />0 <br />Norman E. Goth, FL Lic # 57809, CA Lic { 27905 <br />t, z <br />= w <br />LL <br />O <br />5 dt✓ �.�d � � r ..�� <br />��a'3E1 3 U) <br />w <br />SHEETS BEARING IS SEAL ARE Q <br />AUTHENTICATED, RESPONSIBILITY FOR w <br />ALL OTHER PLANS, SPECIFICATIONS = <br />OR INSTRUMENTS ARE DISCLAIMED. <br />LL_ <br />O <br />Z <br />w <br />V) <br />z <br />O <br />iD U <br />[•o � w <br />a o� <br />3 <br />o ID <br />W ow <br />Z U) <br />Z�� <br />N0�o=. X <br />.o W (% N W w <br />11.WNW :E <br />us <br />Wa�m o <br />•� HIWN <br />D0cm <br />00 o <br />wM <br />�► �M�0214 m <br />z <br />0 <br />I— <br />U <br />° <br />W <br />w <br />w <br />O <br />HJ <br />z <br />Z <br />0 <br />V) W <br />O <br />Q z <br />z <br />a.M <br />V) <br />0 <br />O (M 0 <br />�-�O 1: <br />W <br />J <br />J o <br />Q <br />JON w <br />m J <br />J j J a <br />J Q = w_ <br />MI— <br />.. O� w <br />w t0 <br />wa Z <br />M r W W <br />aZtON <br />> <br />D' <br />w <br />Q 0 <br />LL <br />Z In <br />o tD 0 M 0 O <br />C 0 0 (10 <br />N — I <br />4 N 0 W <br />L <br />O N N E9 <br />W m I <br />ILL <br />�m� <br />In z 0 <br />1111 Fr a 3 z <br />mrn aL 3 w <br />rrrQ <br />V) <br />z <br />0 <br />Q <br />� U <br />IL <br />U <br />w <br />I <br />V) <br />0 <br />z <br />Q <br />U) <br />0 <br />z <br />Q <br />0 <br />vi <br />z <br />c� <br />DRAWN BY: CHECKED BY: w <br />JTH NEG <br />DATE: <br />10/06/14 0 <br />0 <br />N <br />REVISION: <br />_ <br />0 <br />PROJECT NUMBER: <br />W <br />ZRH 0 <br />SHEET NUMBER UO <br />