My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6190 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6190 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:51:47 AM
Creation date
2/19/2025 8:19:44 AM
Metadata
Fields
Template:
Building Plans
Street #
6190
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
2999
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STUCCO ON FRAME - 7/3" 3-COAT SAND FLASHING REQUIREMENTS }CU' <br />FIBER CEMENT SIDING R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A <br />FINISH STUCCO ON SELF FURRING LATH ON CU <br />WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE <br />PER ELEVATIONS cn <br />2- LAYERS OF WATER RESISTIVE BARRIER }, <br />Cl)COMPLYING WITH ASTM E2556, TYPE 1 (TYP) WALL SHEATHING PER PLAN SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. > <br />WALL SHEATHING PER PLAN O <br />STUCCO ON FRAME - 7/8" 3-COAT SAND WALL SHEATHING PER PLAN R703.1 .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED �--• <br />WALL SHEATHING PER PLAN AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER O Q O <br />FINISH STUCCO ON SELF FURRING LATH ON SHINGLE WATER RESISTIVE CU <br />2- LAYERS OF WATER RESISTIVE BARRIER FIBER CEMENT SIDING WITHIN THE WALL ASSEMBLY BY PROVIDING AWATER-RESISTANT BARRIER BEHIND THE C cu IZ <br />SHINGLE WATER RESISTIVE COMPLYING WITH ASTM E2556, TYPE 1 TYP BARRIER OVER FLASHING PER ELEVATIONS +r <br />BARRIER OVER WEEP SCREED (TYP) EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO � V � <br />STARTER STRIP THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. C CU O O <br />WEEP SCREED SHINGLE WATER RESISTIVE SHINGLE WATER RESISTIVE (D U <br />BARRIER OVER WEEP SCREED BARRIER OVER FLASHING R703.2 WATER RESISTIVE BARRIER. ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM C O 'i <br />HOLD 1/4" AIR GAP HOLD 1/4" AIR GAP HOLES, COMPLY WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED O Q C O <br />BETWEEN WEEP WEEP SCREED BETWEEN SIDING AND STARTER STRIP WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL C C O Ll- <br />SCREED AND FLASHING:�: HOLD 1/4" AIR GAP FLASHING HOLD 1/4" AIR GAP EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE O > <br />UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE ._ O <br />COUNTER FLASHING BETWEEN WEEP COUNTER FLASHING BETWEEN SIDING AND O i <br />SCREED AND FLASHING FLASHING JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED cn +-• CD- <br />CONT SELF ADHERED FLASHING TO CONT SELF ADHERED FLASHING TO MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE s CQ a - <br />LAP FLASHING AND TURN 3" UP WALL CONT SELF ADHERED FLASHING TO LAP FLASHING AND TURN 3" UP WALL CONT SELF ADHERED FLASHING TO BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT � .� Cn Q <br />FLASHING— LAP FLASHING AND TURN 3" UP WALL FLASHING LAP FLASHING AND TURN 3" UP WALL OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />PT 1X10 BLOCKING PT 1X BLOCKING PT 1X10 BLOCKING PT 1X BLOCKING APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />CONT SELF ADHERED FLASHING COUNTER FLASHING CONT SELF ADHERED FLASHING COUNTER FLASHING <br />R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />TURN 3" UP BLOCKING TURN 3" UP BLOCKING <br />co PAN FLASHING 6" MIN PAN FLASHING 6" MIN INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />CEMENT MORTAR s7l <br />ROOF UNDERLAYMENT TO CEMENT MORTAR ROOF UNDERLAYMENT TO SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />TILE ROOF PER SPECS TURN UP BLOCKING MIN 6 TILE ROOF PER SPECS TURN UP BLOCKING MIN 6 INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />ROOF UNDERLAYMENT TO CONT SELF ADHERED FLASHING ROOF UNDERLAYMENT TO CONT SELF ADHERED FLASHING <br />PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING INSTALLED IN <br />TURN UP BLOCKING MIN 8" TURN 3" UP BLOCKING TURN UP BLOCKING MIN 8" TURN 3" UP BLOCKING ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />BARRIER IS DIRECTED BETWEEN THE LAYERS. <br />ROOF SHEATHING TILE ROOF PER SPECS ROOF SHEATHING TILE ROOF PER SPECS <br />PER PLAN PER PLAN EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />2X NAILER SECURELY 2X NAILER SECURELY WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />FASTENED TO DECK FASTENED TO DECK THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />ROOF SHEATHING ROOF SHEATHING DESIGNED DRAINAGE SPACE. <br />NOTE: PER PLAN PER PLAN <br />ALL LATH AND LATH R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED <br />ATTACHMENTS TO BE MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />OUT OF CORROSION SHINGLE -FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />-RESISTANT MATERIAL METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S <br />HEAD WALL RAKE WALL HEAD WALL RAKE WALL INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />ROOF TO WALL - BARREL TILE TO STUCCO _ ROOF TO WALL - BARREL TILE TO SIDING ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />BUILDING STRUCTURAL FRAMING COMPONENTS. <br />3„_ 1,_Q„ W P 16 3„ 1 �_011 W P 17 SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />SHING'-E ROOF PER SPECS GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />UNDERLAYMENT TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />TO SHINGLE OVER WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />DRIP EDGE OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />FOLLOWING LOCATIONS: <br />ROOF SHEATHING <br />PER PLAN 1. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW <br />AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />DRIP EDGE FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />2X6 SUB FASCIA FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />SELF ADHERED WRB TO OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />SHINGLE OVER WRB ON <br />FOLLOWING: <br />WALL BELOW 1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING <br />INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />ALUMINUM BRAKE METAL WRAP FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />CONT BACKER ROD INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />AND SEALANT INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />STUCCO 'J' MOULDING WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />HOLD OFF BRAKE METAL RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN 1 <br />FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD <br />1/4 MIN AND SIDES, <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />STUCCO ON FRAME - 7/8" <br />3-COAT SAND FINISH STUCCO REGISTERED DESIGN PROFESSIONAL. k <br />ON SELF FURRING LATH ON 2- 1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />LAYERS OF WATER RESISTIVE 1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />BARRIER COMPLYING WITH 250, FMA/AAMA/WDMA 300 OR FMA/AAMA/WDMA 400. <br />ASTM E2556, TYPE 1 (TYP) 2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />WALL SHEATHING PER PLAN 3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />COPINGS AND SILLS. <br />f <br />4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. <br />6.6 AT WALL AND ROOF INTERSECTIONS. <br />7.7 AT BUILT-IN GUTTERS. <br />ROOF EDGE DETAIL THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />3„_ 1 1_011 W P 18 FLASHING AND WATERPROOFING METHODS TO BE USED. <br />=W <br />ICU <br />MAY 0 2 2023 -�—� ♦._, <br />CD <br />Qa) <br />Virtual Review Assist. Inc. C6 <br />Flans Review completed and approv 0 <br />Ivr compliance with the 2020 FBC 7th Edi ion L— <br />by Debra Anne Klahr PX2300 0- <br />0 <br />O <br />o <br />^^L <br />CD <br />c V/ <br />CU <br />CU w ■ ■ ■ <br />Q <br />Z <br />Z <br />Q <br />J <br />a <br />SHEET NO. <br />WP 2A <br />
The URL can be used to link to this page
Your browser does not support the video tag.