My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6190 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6190 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:51:47 AM
Creation date
2/19/2025 8:19:44 AM
Metadata
Fields
Template:
Building Plans
Street #
6190
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
2999
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6'-5" <br />5' <br />5'-10"1 <br />BEDROOM <br />#4 <br />BEDROOM <br />#5 <br />0 <br />V <br />BEDROOM <br />#6 <br />6'-7" <br />OWNERS <br />BEDROOM <br />5'-11" <br />AL <br />cs EDRO <br />�._.� <br />0 #3 <br />\' tV <br />V 0O <br />1.7„ BATHROOM 0 <br />- <br />#2 / <br />� GFI <br />A <br />I AHU / \ GFI GFI <br />Cl) <br />OS./ � <br />3'-9" <br />A L — GFI LAUNDRY <br />\ LIGHT AND <br />/1SWITCH IN <br />TTIC <br />0S 7'' <br />W.I.C. <br />LO <br />LOFT <br />F <br />\ \ 11-7" <br />/ cs <br />/' --- — <br />GFI L---- ! <br />OWNERS tj <br />BATHROOM T01ST <br />rFLR ELEC <br />SECOND FLOOR ELECTRICAL PLAN (ALL ELEVATIONS' <br />1 /411 = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />MAY 0 2 ?0?1 <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />io <br />SWITCH Uj <br />° <br />DOOR JAMB DUPLEX <br />OUTLET <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />® STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />—p PUSH BUTTON FOR GARAGE DOOR OPENER <br />—o DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />-t} CLG MNT LT FIXTURE <br />{} CLG MNT PREWIRE - FIXTURE BY OWNER <br />{} SURFACE MNT FIXTURE <br />}- WALL MNT FIXTURE <br />l NOTE: <br />0 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />6 50W MR16 4" LOW VOLTAGE OWNER <br />8 50W PAR20 NFL 4" MINI ROUND RECESS <br />00 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />Cos SMOKE DETECTOR <br />V SMOKE DETECTOR <br />�U-18a UNDER CABINET 18" <br />�S-182 SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />= D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />97 24 :R 24" VANITY LIGHTING <br />F;;F 36 ;7nR 36" VANITY LIGHTING <br />Fu--48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />J� MASTER STATION <br />-MV%;] ELEC PANEL <br />® VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />EM A/C REGISTER <br />�i THERMOSTAT <br />SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />to <br />n� <br />N L <br />N E <br />` 0 <br />_W L . <br />o <br />i,} ��c 5 <br />N <br />V -0-0- 2 <br />M <br />` 2 <br />Y/ 00 <br />p <br />00 <br />.�� <br />^^`` <br />`Up°� <br />QN <br />V co M C <br />E <br />7W <br />V <br />L O c .N <br />CO70 <br />W <br />UH� <br />W OLL< <br />'0CY¢1<g- �Zz��� <br />.V <br />❑� <br />QXOG6LL�O� <br />2Cy11W)9tWOOM <br />OZCL <br />pQu�j <br />W W <br />x ¢ <br />wO� <br />DzW <br />JILzZQwQ <br />LL <br />OW �F—� <br />O� ❑ ❑ <br />2YZ <br />❑¢ <br />¢ ¢ <br />LL¢ o <br />R <br />O <br />Z N <br />OW <br />z <br />I--� cM O <br />Q � cM � <br />W LL <br />� <br />ti <br />z <br />< W < Lq <br />F-0�a.M <br />00 <br />Z V F- <br />W <br />J O <br />O <br />I <br />i <br />I <br />I <br />I <br />CD <br />o <br />Cq of <br />o <br />0 <br />0 <br />N <br />o <br />o <br />o <br />0 <br />0 <br />O <br />z <br />' <br />0 <br />N� <br />Ln <br />w <br />o <br />0 <br />0 <br />0 <br />0 <br />0 <br />c/ <br />z <br />Q w <br />O <br />W <br />Op0 <br />`. <br />O <br />V <br />VVV5 <br />Lo <br />-� <br />O <br />or< <br />QT--1 <br />Z <br />F— <br />a-[L <br />Ln <br />= <br />Uj <br />m=w <br />H <br />W <br />Zo <br />eN <br />aF-W <br />0 <br /><D <br />z <br />oo(0 <br />O <br />" <br />v <br />aZLL <br />w <br />Z <br />Z <br />�z <br />OU <br />0 <br />W <br />z <br />z <br />w <br />W <br />J <br />0 <br />V <br />LAST PLOT DATE <br />N <br />• <br />March 31, 2023 <br />O <br />2ND FLOOR <br />J <br />ELECTRICAL PLAN <br />ABKL&M <br />
The URL can be used to link to this page
Your browser does not support the video tag.