My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6191-6207 Daerr Ridge St
Zephyrhills
>
Building Department
>
Building Plans
>
6191-6207 Daerr Ridge St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:29:56 PM
Creation date
2/19/2025 8:08:58 AM
Metadata
Fields
Template:
Building Plans
Street #
6191-6207
Location
Daerr Ridge St
Contractor
Starlight Homes
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BUILDING CODE FLORIDA BUILDING CODE, RESIDENTIAL, 7TH EDITION (=) <br />MINIMUM ROOF LOADING: <br />TOPCHORDLIVELOAD: <br />LESS THAN 4/12 PITCH 20 PSF <br />4112 PITCH OR GREATER_16 PSF <br />TOP CHORD DEAD LOAD: <br />METAL OR SHINGLE 7 PSF (REFER TO NOTE 1) <br />CONCRETE OR CLAY TILE 15 PSF (REFER TO NOTE 1) <br />1. BUILDER SHALL VERIFY WITH ROOF COVERING MANUFACTURER'S WRITTEN <br />SPECIFICATIONS, AND SHALL NOTIFY ENGINEER OF RECORD IF ADDITIONAL LOADING IS <br />REQUIRED. <br />BOTTOM CHORD LIVE LOAD: <br />UNINHABITABLE ATTIC WITHOUT STORAGE 10 PSF <br />UNINHABITABLE ATTIC WITH LIMITED STORAGE 20 PSF <br />HABITABLE ATTIC, AND ATTIC SERVED WITH FIXED STAIRS/SWANG DOOR 30 PSF <br />ATTIC LOAD CONCURRENCY AND STORAGE AREA CLASSIFICATIONS SHALL BE APPLIED AS <br />DEFINED IN THE GOVERNING BUILDING CODE SECTIONS: FBC-R301.5 OR FBC 1607.1 <br />BOTTOM CHORD DEAD LOAD 10 PSF <br />MINIMUM FLOOR LOADING <br />TOP CHORD LIVE LOAD: <br />RESIDENTIAL FLOOR 40 PSF <br />GAME OR GATHERING ROOMS_60 PSF <br />STAIRS 40 PSF <br />DECKS 40 PSF <br />BALCONIES (LESS THAN 100 SF) ___SO PSF <br />BALCONIES 100 PSF <br />TOP CHORD DEAD LOAD: <br />CARPET, VINYL, OR WOOD 10 PSF <br />CERAMIC TILE 10 PSF (REFER TO NOTE 2) <br />2. TILE FLOOR LOADING ASSUMES AN INSTALLED WEIGHT OF 7 PSF OR LESS (IN ADDITION TO <br />A 231324NCH OSS SUBSTRATE) FOR THE TILE ASSEMBLY AS DEFINED IN THE TCNA <br />HANDBOOK FOR CERAMIC, GLASS, AND STONE TILE INSTALLATION. THE CONTRACTOR <br />SHALL VERIFY THE TILE ASSEMBY WEIGHT AND SUPPORT REQUIREMENTS. IF THE <br />ASSEMBLY EXCEEDS 7 PSF, OR REQUIRES FLOOR JOIST/TRUSS SPACING LESS THAN <br />241NCHES O.C., CONTACT ENGINEER OF RECORD FOR REVIEW PRIOR TO INSTALLATION. <br />BOTTOM CHORD LIVE LOAD OPSF <br />BOTTOM CHORD DEAD LOAD 5 PSF <br />GUARDS AND HANDRAILS: <br />CONTINUOUS LOAD 50 PLF <br />MAXIMUM POINT LOAD 200 LISS <br />IN -FILL COMPONENTS 50 PLF <br />DEFLECTION CRITERIA <br />ROOF RAFTERSRRUSSES <br />LIVE LOAD L / 240 <br />TOTALLOAD L1240 <br />FLOOR JOISTS/TRUSSES <br />LIVE LOAD L 136D (REFER TO NOTE 3) <br />TOTALLOAD L / 240 (REFER TO NOTE 3) <br />3. FLOOR COVERINGS MAY REQUIRE STIFFER DEFLECTION REQUIREMENTS, REFER TO <br />FLOOR MANUFACTURER'S WRITTEN SPECIFICATIONS, FOR TILE FLOORING, REFER TO THE <br />TCRA RECOMMENDATIONS FOR DEFLECTION LIMITS FOR THE TILE ASSEMBLY. THE <br />CONTRACTOR SHALL VERIFY THE FLOOR COVERING DEFLECTION REQUIREMENTS, AND <br />CONTACT ENGINEER OF RECORD FOR REVIEW PRIOR TO INSTALLATION IF STIFFER FLOOR <br />MEMBERS ARE REQUIRED. <br />WALLS <br />WIND LOADS WITH PLASTER OR STUCCO FINISH _L 1360 <br />WIND LOADS OATH OTHER BRITTLE FINISHES L 1240 <br />WIND LOADS WITH FLEXIBLE FINISHES 1,1100 <br />DIFFERENTIAL OEFLECI10lL <br />THE ENGINEER OF RECORD RECOMMENDS LIMITING DIFFERENTIAL DEFLECTIONS BETWEEN <br />ADJACENT ROOF AND FLOOR TRUSSES OR JOISTS TO TWICE THE SPACING DIVIDED BY THE <br />DEFLECTION LIMIT. FOR TYPICAL FLOOR AND ROOF MEMBERS SPACED AT 24-O.C_ THE <br />ENGINEER OF RECORD RECOMMENDS LIMITING DIFFERENTIAL DEFLECTIONS TO THE <br />FOLLOWING VALUES: <br />ROOF RAFTERS/TRUSSES SPACED AT 24'O.C. <br />LIVE LOAD L1240: 0.20' MAX DIFFERENTIAL DEFLECTION <br />TOTALLOAD L/180: 0.27'MAX DIFFERENTIAL DEFLECTION <br />FLOOR JOISTSITRUSSES SPACED AT 24' O.C. <br />LIVE LOAD L 1360: 0.13' MAX DIFFERENTIAL DEFLECTION <br />TOTAL LOAD L1240: 0.20'MAX DIFFERENTIAL DEFLECTION <br />ABBRMATIOW <br />A.B. ANCHOR BOLT <br />A/C AIR CONDITIONER INT. INTERIOR <br />A.F.F ABOVE FINISHED FLOOR MAX MAXIMUM <br />A.H.U. AIR -HANDLER UNIT MCD MONTA CONSULTING & DESIGN <br />ALT. ALTERNATE MIN. MINIMUM <br />A.T.R. ALL THREAD ROD MONO. MONOLITHIC <br />BCOL. BOTTOM CHORD DEAD LOAD MPS' MILLION POUNDS /SQUARE INCH <br />BRG. BEARING NO. NUMBER <br />CANT. CANTILEVER N.T.S. NOT TO SCALE <br />t CENTER LINE O.C. ON CENTER <br />C.J. CONTROL JOINT OPT. OPTIONAL <br />CMU CONCRETE MASONRY UNIT PLF POUNDS PER LINEAR FOOT <br />CONT. CONTINUOUS PLT. PLATE <br />D.F. DRINKING FOUNTAIN PSF POUNDS PER SQUARE FOOT <br />DIX DIAMETER PSI POUNDS PER SQUARE INCH <br />EA EACH P.T. PRESSURE TREATED <br />ELEC ELECTRICAL READ REQUIRED <br />ELEV ELEVATION RM. ROOM <br />E.O.R. ENGINEER OF RECORD R.O. ROUGH OPENING <br />E.W EACH WAY SCL STRUCTURAL COMPOSITE LUMBER <br />EXT. EXTERIOR SGD SUDING GLASS DOOR <br />FBC FLORIDA BUILDING CODE SUM. SIMILAR <br />F.F.E. FINISHED FLOOR ELEVATION SPF SPRUCE PINE FUR <br />FUR. FLOOR SQ. FT. SQUARE FOOT/FEET <br />FND, FOUNDATION SUB SUB -CONTRACTOR <br />F.R. FIRE RATED SYP SOUTHERN YELLOW PINE <br />FT. FOOT/FEET TCDL TOP CHORD DEAD LOAD <br />FTG. FOOTING TCLL TOP CHORD LIVE LOAD <br />F.V. FIELD VERIFY T.O.M. TOP OF MASONRY <br />GALV. GALVANIZED TOW TOP OF WALL <br />G.C. GENERAL CONTRACTOR TRANS. TRANSOM <br />OT. GIRDER TRUSS TYP. TYPICAL <br />GYP. GYPSUM U.N O. UNLESS NOTED OTHERWISE <br />HDR. HEADER VERT_ VERTICAL <br />MGT. HEIGHT W/ WITH <br />HORIZ. HORIZONTAL W/VF WELDED WIRE FABRIC <br />I.L.O. IN LIEU OF <br />WIND CODE: <br />ASCE 7-16, MODIFIED PER FLORIDA BUILDING CODE, <br />RESIDENTIAL, 7M EDITION (2020) <br />WIND DESKlt4 IREOUIREMENTS: <br />RISKCATEGORY <br />BUILDING TYPE VB <br />WIND SPEED (ULTIMATE) 139 mph <br />WIND SPEED (ALLOWABLE) log mph <br />WIND EXPOSURE C <br />ENCLOSURE CLASSIFICATION ENCLOSED <br />INTERNAL PRESSURE COEFFICIENT 0.18 <br />MAXIMUM MEAN ROOF HEIGHT 30 I <br />VELOCITY PRESSURE COEFFICIENT 0.98 <br />BASIC VELOCITY PRESSURE 41.3 P%1 <br />4 k <br />4 4 <br />O ZONE 4 a = 4 FEET FROM ALL EXTERIOR <br />® ZONE 5 CORNERS PER FBC-R301 2(7) <br />ROOF SHEATHING & NAILING' <br />COMPONENT AND CLADDING DESIGN PRESSURES <br />WINDOWS AND DOORS <br />EFFECTIVE <br />WIND AREA <br />(SQUARE FEET) <br />ZONE4 <br />PRESSURES <br />(PSF) <br />ZONES <br />PRESSURES <br />(PSF) <br />0 - 19I? <br />+29.2 .31.7 <br />+29.2 -39.1 <br />20-4911' <br />+27.9 -30A <br />+27.9 -36.5 <br />50-99A? <br />+26.2 -28.7 <br />+26.2 -33.0 <br />1 o0 -199 ft +24.9 <br />-27.3 <br />+24.9 -30.4 <br />200+1? <br />+23.5 .26.0 <br />+23.5 .27.8 <br />147' x V-0" GARAGE DOOR +25.7 -29.1 <br />7'-X x 16'4Y GARAGE DGOR +24.6 -27.5 <br />SOFFIT PRESSURES +29.2 -39.1 <br />PRESSURES LISTED ABOVE ARE DESIGN PRESSURES. MULTIPLY <br />BY 1,67 TO CONVERT TO ULTIMATE WAND PRESSURES. <br />ROOF SHEATHING AND NAILING <br />SHEATHING <br />ROOF SHEATHING NAIUNG: <br />ALTERNATE ROOF SHEATHING NAILING. <br />ROOF PITCH <br />MINIMUM <br />EAVE/RIDGE <br />INTERIOR <br />ALTERNATE <br />EAVE/RIDGE <br />INTERIOR <br />2, <br />SPAN <br />MINIMUM <br />NAIL <br />SPACING <br />SPACING <br />NAIL <br />SPACING <br />SPACING <br />O <br />.0 <br />RATING <br />THICKNESS <br />TYPE <br />(EDGE/FIELD) <br />(EDGE/FIELD) <br />TYPE <br />(EDGE/FIELD) <br />(EDGE !FIELD) <br />�m <br />m <br />4/12&LESS <br />32f16 <br />15/32" <br />RSRS-01 <br />6/6 <br />6/6 <br />0.131"x3" <br />4/6 <br />6/6 <br />GREATER <br />GREATER <br />24f16 <br />7/16" <br />RSRS 01 <br />6/6 <br />//6 <br />0.131"x3" <br />4/6 <br />6/6 <br />RECOMMENDED <br />40/20 <br />19/32' <br />RSRS-03 or <br />6/6 <br />6/6 <br />0.131"x3" <br />4/fi <br />6/6 <br />w wo <br />(ALL PITCHES) <br />RSR51M <br />t-0 <br />ALTERNATIVE <br />(IF PERMITTED) <br />32/16 <br />15/32" <br />RSRS-01 <br />6/6 <br />6/6 <br />0.131"x3' <br />4/6 <br />6/6 <br />'NOTE SHEATHING THICKNESS AND ATTACHMENT IS ENGINEERED ACCORDING TO THE PROVISIONS OF FBC-R SECTION R301.1 AND DOES NOT <br />MATCH THOSE OUTLINED IN SECTION R8032. CALCULATIONS CAN BE PROVIDED UPON REQUEST <br />1_ ALL SHEATHING SMALL BE EXTERIOR EXPOSURE 1 APA RATED <br />SHEATHING. FOR SHINGLE ROOFS, OSB OR PLYWOOD <br />(MINIMUM 3PLY) CONSTRUCTION IS PERMITTED. FOR TILE & <br />METAL ROOFS, PLYWOOD CONSTRUCTION IS REQUIRED <br />UNLESS OTHERWISE NOTED IN MANUFACTURERS WRITTEN <br />SPECIFICATIONS. <br />2. BUILDER SMALL VERIFY MINIMUM ROOF SHEATHING OATH THE <br />SHINGLE MANUFACTURER'S WRITTEN SPECIFICATIONS. <br />3. SHEATHING TO BE PLACED WITH LONG DIMENSION <br />PERPENDICULAR TO SUPPORTS (TRUSSES). PROVIDE PLY <br />CLIPS AT ALL UNSUPPORTED ROOF SHEATHING JOINTS EXCEPT <br />AT PITCH CHANGE LOCATIONS. PLY CLIPS TO BE SPACED NO <br />MORE THAN 24' O.C. <br />4. IF ANY PORTION OF ROOF ON THE STRUCTURE HAS A PITCH <br />LESS THAN OR EQUAL TO 4 112, THE BUILDER SHALL USE THE <br />SHEATHING REQUIRED FOR THE 4112 PITCH FOR THE ENTIRE <br />STRUCTURE. <br />5, THE'EAVE/RIDGE'ZONE IS MEASURED 4 FEET FROM THE <br />PERIMETER OF THE EDGE OF THE ROOF, AND 4 FEET EACH SIDE <br />OF RIDGES AND HIPS_ <br />6. EDGE = NAIL SPACING ALONG PANEL EDGES. <br />7, FIELD= NAIL SPACING ALONG INTERMEDIATE SUPPORTS IN THE <br />PANEL FIELD. <br />8, RSRS-01, RSRS-03, RSRS-04 ARE RING SHANK NAILS MEETING <br />THE SPECIFICATIONS IN ASTM F1667. <br />9. 0.131' X T SMOOTH SHANK NAILS MAY BE USED IF NOTED IN <br />THE ROOF SHEATHING AND NAILING TABLE. 'N.P.' INDICATES <br />THAT ALTERNATIVE NAILS ARE NOT PERMITTED. <br />TLE ROOFS: <br />1. BUILDER SHALL UTILIZE THE RECOMMENDED ROOF SHEATHING <br />SPECIFICATIONS. BUILDER MAY USE THE ALTERNATIVE ROOF <br />SHEATHING ONLY WH N PERMITTED BY THE MANUFACTURERS <br />WRITTEN SPECIFICATIONS. 'N.P' INDICATES ALTERNATIVE <br />SHEATHING IS NOT PERMITTED FOR THIS PROJECT. <br />1. MINIMUM EXTERIOR EXPOSURE 1 APA RATED SHEATHING, <br />WITH A MINIMUM SPAN RATING OF 24116, AND A MINIMUM <br />THICKNESS OF 7/16" OSB OR PLYWOOD (MINIMUM 3 PLY) <br />CONSTRUCTION IS PERMITTED. <br />2. PANELS MAYBE LAID PERPENDICULAR OR PARALLEL TO <br />SUPPORTS. <br />3. NAIL WITH (1)-ROW0131'x2-lrr NAILS AT TO C. AT EDGES, <br />AND 6' O.C. IN THE FIELD. INSTALL MIN. 2x4 SYPI2 <br />BLOCKING AT ALL SHEATHING JOINTS. <br />EXTERIOR WALLS: <br />REFER TO DETAIL WF10 FOR MORE INFORMATION. <br />FASTENERS: <br />REFER TO SHINGLE ROOF TABLE FOR NAIL SIZES TO BE USED TO <br />FASTEN ROOF SHEATHING TO ROOF FRAMING. ALL OTHER <br />SHEATHING APPLICATIONS SHALL BE 0.131' x 2-12" OR RSRS-03 <br />NAILS. GUN DRIVEN NAILS SHALL HAVE HEAD SIZE EQUIVALENTTO <br />HAND DRIVEN NAILS. FASTENERS FOR PRESERVATIVE TREADED <br />WOOD SHALL BE HOT -DIPPED ZINCCOATED GALVANIZED STEEL. <br />THE COATING WEIGHTS SMALL BE IN ACCORDANCE WITH ASTM <br />A153. <br />APA RATED SHEATHING NOTE: <br />SPAN RATED SHEATHING REQUIRES BLOCKING AT ALL <br />UNSUPPORTED PANEL EDGES AT HIP LOCATIONS OR LOCATIONS <br />OF A PITCH CHANGE. BLOCKING TO BE 2,4 SYP 02, NAILED AT <br />EACH END WITH (3H 0.131' x 3" TOE -NAILS. <br />INTERIOR ZONE <br />EAVE/RIDGEZONE <br />a =4 FEET FROM ALL <br />EAVES AND RIDGES <br />PER FBGat301.2(/) I- I- <br />Q'/ T . c �r <br />STANDARD NAIL SCHEDULE <br />STANDARD NAIL <br />GENERAL DIAMETER/ <br />HEAD DIAMETER <br />LENGTH <br />8d <br />0.131"x2} <br />.291' <br />10d <br />0.148' x 3' <br />.312' <br />.131"x3"GUN NAIL <br />0A31'x 3' <br />.251' <br />12d&1W SINKER <br />0.148'x 3}' <br />.312' <br />red <br />0.162" x 3t <br />344' <br />(RSRS-01)RINGSHANK <br />oll-x2f- <br />(RSRS-03) RING SHANK <br />0.131'x2}' <br />.281' <br />(RSR54M) RING SHANK <br />0.120' x 3' <br />.261' <br />NAILING NOTES <br />1. CONTRACTOR MAY USE A DIFFERENT NAIL THAN INDICATED <br />AS LONG AS IT MEETS OR EXCEEDS THE DIAMETER AND <br />LENGTH INDICATED. <br />2, CONNECTORS MAY USE DIFFERENT NAIL LENGTHS. <br />MINIMUM NAIL LENGTH PER CONNECTOR IS RED, IF LONGER <br />NAIL IS USED IT IS ADEQUATE AS LONG AS IT DOES NOT <br />EXTEND THRU THE MEMBER ITS BEING ATTACHED TO. <br />3. PER CONNECTOR SPECIFICATIONS ALL NAILS TO BE <br />SPECIFIED PER CONNECTOR MANUFACTURER <br />4. ALL NAILS TO MEET ASTM F1667. <br />INDEX OF DRAWINGS <br />I SHEET I SHEET TITLE I <br />S1 <br />STRUCTURALCOVER <br />S1.1 <br />STRUCTURAL NOTES <br />S2 <br />FOUNDATION PLAN <br />S2.1 <br />FOUNDATION PLAN <br />S3 <br />FOUNDATION DETAILS <br />S4 <br />NOT USED <br />S5 <br />FIRST FLOOR FRAMING PLAN <br />S6 I MODEL SPECIFIC DETAILS <br />I SD5 I TWO STORY DETAILS I= <br />PW1 <br />U373 WALL ASSEMBLY <br />PW2 <br />U336 WALL ASSEMBLY <br />PW3 <br />NOT USED <br />PW4 <br />U347 WALL ASSEMBLY <br />PW5 <br />V344 WALL ASSEMBLY <br />SDWC <br />I SDWC DETAILS <br />SDWF SDWF DETAILS <br />WP1 WALL PANEL FRAMING DETAILS <br />ST1 GENERAL STAIR DETAILS <br />MASTER UPDATES <br />I NUMBER I DATE I DESCRIPTION I INTIALS I,' <br />1 1 1 2/24/2023 1 CREATED 5-UNIT BUILDING TYPE 'A' PER TYTH-BLDG 2 (BFS) IDP 1'. <br />W <br />H <br />I - <br />pp <br />W L d E <br />OU <br />J c�< <br />Jn f$ <br />0 it = - <br />Zzm' <br />U v g <br />ZO <br />VJ i <br />S STRUCT: DP <br />4 aCHEac: CC <br />0 <br />w JOB No. STAR-15%1 <br />t SCALE: AS INDICATED <br />w DATE: m112J <br />S1 <br />COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. <br />
The URL can be used to link to this page
Your browser does not support the video tag.