Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1 `" LONG (3"-1 CROWN) <br />WALL. SHEATHING <br />STAPLES is 6"" O.C. VERT BETWEEN r I r i�x t I t I 1 r 16GAx1-1/2" LONG (3/4"-1" <br />STUDS (NOTED THUS:—)- OFFSET I I I I I I 'CROWN) STAPLES qat 6" <br />STAPLES BETWEEN STUDS AS SHOWN - _.__._._.... O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />I <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />`ONLY APPLIES TO LENNAR TPAIJAX** <br />LATHING ACCESSORIES: <br />ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. <br />WOOD APPLICATION: 16 GA. x 1-1/2" LONG (3/4"-1" CROWN) STAPLES @ 6" O.C. <br />VERTICALLY/HORIZONTALLY INTO FRAMING MEMBERS. <br />MASONRY APPLICATION: CONCRETE STUB NAIL, 3/8" (10 MM) HEAD DIA. MIN. @ <br />6" O.C. VERTICALLY/HORIZONTALLY OR COMPATIBLE ADHESIVES, EXTERIOR <br />GUN -GRADE, CONSTRUCTION ADHESIVE WITH 1" DABS @ 6" O.C. OR IN A <br />SEMI -CONTINUOUS BEAD BETWEEN THE SOLID PLASTER BASE AND THE SOLID <br />PORTION OF THE KEY ATTACHMEN r FLANGE. <br />CONTROL JOINTS: INSTALL CONTROL JOINT LATHING ACCESSORIES IN <br />CONFORMANCE WITH C1063. LATH SHALL NOT BE CONTINUOUS THROUGH <br />CONTROL JOINTS, BUT SHALL BE STOPPED AND TIED AT EACH SIDE. <br />ALL ACCESSORIES SHALL BE IN ACCORDANCE WITH THE LATEST ASTM C1063 & <br />ASTM C1861. <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />STUB -OUT FOR <br />GAS METER O <br />CV <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3) 16d TOENAILS <br />2" X 12" @ 24" O.C. <br />154" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ + <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist Backer Block <br />Series <br />Thickness Filler Block Thickness <br />3/4" or 7/8" Two 3/4" wood panels or 2 x — <br />5000s 1.8/1.7 wood panels <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 wood panels 2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 wood panels 2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 wood panels 2 x — + 5/8" or 3/4" wood panel <br />902.0 2 x _ lumber Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />fi <br />1/8" gap <br />x <br />+ <br />FILL CELL — STD. 900 HOOK r— BOND BEAM <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />fi <br />1/8" gap <br />x <br />+ <br />FILL CELL — STD. 900 HOOK r— BOND BEAM <br />W <br />STD. 90° <br />CONT. #5 <br />CONT. #5 HOOK <br />BAR <br />BAR <br />........... <br />.......... <br />. .......... ............ <br />. <br />#5 CONT, <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min. ) Small gap 2" min. <br />2" <br />max. � 4 max. <br />7' __T <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2'tin. <br />4" max. <br />required when indicated or <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Ya" GAP @ TOP sides by 6", - Hangers with sides not containing WEB STIFFENER <br />t. <br />DOUBLE JOIST CONNECTION top irdsmouthcuts. <br />- Birdsmouth cuts. N.T.S. <br />--- - _ -_ --- ------------- - Under 2nd floor cNumn wi inaris <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below,* <br />local building <br />1116 <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or-20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Boise Joist Blocking <br />for each lapped joist. <br />Squash block) 10d nails SECTION @ INT. BRG. WALL <br />7'2x4 minimum <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />IF-When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />Jse 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />6�� A 1 Z' ROUND HOLE MAY 6 6�. DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />Round Hole Diameter (in) <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />8.875 <br />10 <br />11 <br />12 <br />13 <br />Rectangular Hole Side (in) <br />2 <br />3 <br />5 <br />6 <br />8 <br />9 <br />10 <br />Any 16" joist <br />Span (ft) <br />8 <br />V-0" <br />V-1 " <br />1"-2" <br />V-2" <br />V-3" <br />1 3" <br />V-7" <br />1"-1 1 " <br />2'-4 <br />2'-9" <br />3'-2" <br />3'-7- <br />12 <br />V-0" <br />V-1" <br />V-2" <br />V-2" <br />V-3" <br />1' 9" <br />2'4" <br />2'-11" <br />3' 7" <br />4'-2" <br />4'-9" <br />5'4" <br />16 <br />1'-0" <br />1'-1"' <br />V-2" <br />1'-2" <br />V-7" <br />2'-5" <br />T-2" <br />3%10" <br />4`-9"' <br />5'-7" <br />6' 4'" <br />20 <br />1'-0" <br />11'-l" <br />V-2" <br />1'-2" <br />2'-0" <br />3'-0" <br />4'-0"' <br />4' 10„ <br />5'-11'" <br />E'-11" <br />T-11" <br />8'-11" <br />24 <br />V-0" <br />1'-1" <br />1'-2" <br />11'-3" <br />2'-5" <br />3'-7" <br />4'-9" <br />5'-10 <br />r'-2" <br />8'4'" <br />9'-6" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3, REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5, THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEASTTWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7.1Yz" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9, THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Jc <br />Backer block (12" wide min.) <br />Nall with 10-10d nails. <br />\nstall tight to top flange. <br />Y \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4%2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top P required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />o depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />Web Sti cner Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />3-16d <br />" <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />5/8"0 <br />THRU <br />BOLT <br />SIMPSC <br />w/(22)' <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />LC <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />�� <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />T1 e� FINISH GRADE <br />SLEEVE THRU STEM—/ ° J <br />SEE PLAN FOR °• • ° " <br />FOUNDATION INFO ° ° <br />STEM FOUNDATION <br />�— GRADE REINF. SEE PLAN <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />•�® LOCATION OF <br />SECOND H10A <br />SIMPSON 110A (WHEN <br />w/ (18) 10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />a <br />I I •' <br />° — <br />Tr I I ° <br />1 I <br />F_ I <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE PLUMBING LINE <br />PENETRATION I <br />—r--------- <br />z • ° • 1. <br />co g <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />FF <br />---'--� . --.— -- A.I. ° <br />a <br />a <br />�,—a--a----, /4/ <br />SEE FND. PLN. <br />SIZE & REINF. <br />t <br />t S� W" PLON <br />cM <br />04 <br />OF <br />° �o <br />N <br />M <br />A <br />C\r'I J C,LO <br />e <br />00 <br />,�. <br />AR I. <br />LIJ <br />w <br />Z <br />Q <br />E <br />> C) O <br />L r— so <br />W U <br />CV) CO <br />_>1 <br />tN V 0 °Q, <br />C O O ?5 <br />O U- o Q <br />Q CN c <br />o E <br />7N �. � <br />V a a <br />LU <br />W 0 V?JQO�¢XQLLUOp�O <br />w <br />wg~ Lu J LUMOZtz <br />H H <br />�a0JZ�"°120M0 <br />0 0 �0zOM00m <br />��1L WLEL <br />a <br />Z U <br />'0 <br />0 <br />0 z <br />zuwo�Z,W: <br />��¢0w�?wz��voa <br />a <br />LL <br />00X <br />0 <br />LL¢ LL <br />O <br />Z W <br />O� <br />J <br />ID1.-7MO <br />Q M � <br />U) L <br />ti <br />LU Lf) <br />F—��M <br />a oo <br />V <br />Imo--' <br />Z <br />LU <br />W <br />J0 <br />CD <br />It <br />.01 <br />rqr <br />3 <br />Virtual <br />Ptans Review Re <br />lew,Assi <br />tic. <br />r c0m�liance with <br />thee <br />ed <br />d'To <br />P 4. <br />Y Debra Anne <br />Kt <br />hr <br />►too <br />23 <br />D <br />0) <br />I <br />a <br />o <br />o <br />0 <br />o <br />0 <br />0 <br />3 <br />rn <br />o <br />! <br />I <br />I <br />O <br />Z <br />O <br />, <br />Nj <br />UD <br />c <br />ri <br />I <br />11 <br />CrUD <br />00 U <br />>_ <br />ZZ <br />V^ <br />J <br />QZ <br />C)W <br />Wzz <br />❑00 <br />♦-+ <br />O <br />U <br />U U <br />LO <br />O <br />ova <br />�- <br />Z <br />a� <br />W <br />LU <br />' /�� <br />mrW <br />N <br />O <br />Zo?❑2 <br />W <br />Q <br />>_ <br />Q <br />0 0g�ix <br />W u_ <br />Z <br />Z <br />nZ <br />NZ <br />pU <br />_o <br />W <br />W <br />z <br />SN1 <br />z <br />Z <br />J <br />UJ <br />N <br />r <br />LAST PLOT DATE <br />. . <br />Z110-0 <br />O <br />STRUCTURAL <br />DETAILS <br />