My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6230 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6230 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:52:04 PM
Creation date
2/19/2025 8:21:23 AM
Metadata
Fields
Template:
Building Plans
Street #
6230
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
6280
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />TAPE EDGE OF HEAD <br />WALL FLASHING <br />STUCCO ON FRAME - 7/8" <br />3-COAT SAND FINISH STUCCO <br />ON SELF FURRING LATH ON 2- <br />LAYERS OF WATER RESISTIVE <br />BARRIER COMPLYING WITH <br />ASTM E2556, TYPE 1 (TYP)— <br />P�I���:l�tl:llrCH��;:7�1► <br />SHINGLE WATER <br />RESISTIVE BARRIER <br />OVER WEEP SCREED <br />WEEP SCREED <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL—` <br />18 GA HEAD WALL FLASHING <br />TO EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />SHINGLE ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING \ <br />PER PLAN <br />NOTE: <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL <br />3"= 1 '-0" <br />TAPE EDGE OF HEAD <br />WALL FLASHING <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP; <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED <br />WEEP SCREED <br />HEAD WALL TRIM FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL <br />CONT BUTYL TAPE SEALANT PER <br />MANUFACTURER INSTALLATION <br />INSTRUCTIONS <br />'Z' CLOSU <br />STANDING SEAM METAL <br />ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />=1 1-011 <br />`v <br />z <br />00 <br />HEAD WALL <br />M— 11%\m <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS 0 = WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER <br />RESISTIVE BARRIER <br />OVER WEEP SCREED <br />TAPE EDGE OF COUNTER <br />FLASHING <br />WEEP SCREED <br />COUNTER FLASHING <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL <br />SHINGLE PER SPECS <br />STEP FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />NOTE: <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP; <br />TAPE EDGE OF RAKE <br />WALL FLASHING <br />WAIL SHEATHING PER PLAN <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED ---- <br />WEEP SCREED <br />RAKE WALL STEP FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />FIELD BEND PANEL UP 1 1/2" <br />CONT BUTYL TAPE SEALANT 7PER <br />MANUFACTURER INSTALLATION <br />INSTRUCTIONS <br />'Z' CLOSURE \ <br />STANDING SEAM METAL <br />ROOF PER SPECS <br />ROOF UNDERLAYMENT TO \ <br />TURN UP WALL MIN <br />y' ROOF SHEATHING <br />NOTE: PER PLAN <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE CONT SELF ADHERED <br />OUT OF CORROSION FLASHING TURN 3" UP WALL <br />-RESISTANT MATERIAL <br />HEAD WALL <br />FLASHING REQUIREMENTS <br />R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A <br />WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE <br />TAPE EDGE OF HEAD <br />SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. <br />� > � <br />WALL FLASHING <br />O 2+� <br />FIBER CEMENT SIDING <br />R703.1 .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED <br />Q� Q O <br />FIBER CEMENT SIDING <br />PER ELEVATIONS <br />AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER <br />CD O i <br />PER ELEVATIONS <br />WITHIN THE WALL ASSEMBLY BY PROVIDING AWATER-RESISTANT BARRIER BEHIND THE <br />CU <br />WALL SHEATHING PER PLAN <br />EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO <br />.� U .� <br />WALL SHEATHING PER PLAN <br />THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. <br />co <br />SHINGLE WATE.: <br />Ocu <br />SHINGLE WATER oo <br />RESISTIVE BARRIER <br />R703.2 WATER RESISTIVE BARRIER. ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM <br />C LO — 'i CD <br />RESISTIVE BARRIER <br />OVER FLASHING <br />HOLES, COMPLY WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED <br />C CZ C O ?� <br />OVER FLASHING <br />WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL <br />O <br />TAPE EDGE OF COUNTER <br />EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE <br />O O � '0 O <br />O <br />STARTER STRIP <br />FLASHING <br />UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE <br />.� -p E O <br />\ <br />00 <br />80 <br />JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED <br />c/) N a <br />\ <br />CONT SELF ADHERED <br />STARTER STRIP <br />MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE <br />cou) 4O i.,, LZ <br />FLASHING TURN 3" UP WALL <br />COUNTER FLASHING <br />BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT <br />I— .0 <br />OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />18 GA HEAD WALL FLASHING <br />CONT SELF ADHERED <br />TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />TO EXTEND MIN 8" BEYOND <br />FLASHING TURN 3" UP WALL <br />APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />UNDERLAYMENT <br />ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />z <br />SHINGLE PER SPECS <br />SHINGLE ROOF PER SPECS <br />R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />co <br />STEP FLASHING TO <br />INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />ROOF UNDERLAYMENT TO <br />EXTEND MIN 8" BEYOND <br />SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />TURN UP WALL MIN 8" <br />UNDERLAYMENT <br />PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />z <br />z <br />INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />ROOF SHEATHING <br />ROOF UNDERLAYMENT TO <br />PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN <br />00 <br />PER PLAN <br />TURN UP WALL MIN 8" <br />00 <br />ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />`v <br />v <br />BARRIER IS DIRECTED BETWEEN THE LAYERS. <br />ROOF SHEATHING <br />PER PLAN <br />`' <br />EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />Ilk %k <br />THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />6" <br />DESIGNED DRAINAGE SPACE. <br />6 <br />R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED <br />MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S <br />RAKE WALL <br />HEAD WALL <br />RAKE <br />WALL <br />INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />ROOF T WALL <br />W P 12 <br />- <br />-SHINGLETSIDING <br />W P 13 <br />BUILDING STRUCTURAL FRAMING COMPONENTS. <br />3It 1 1-011 <br />SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />TAPE EDGE OF HEAD <br />GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />WALL FLASHING <br />ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />FIBER CEMENT SIDING <br />WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />FIBER CEMENT SIDING <br />PER ELEVATIONS <br />OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />PER ELEVATIONS <br />FOLLOWING LOCATIONS: <br />TAPE EDGE OF RAKE <br />WALL FLASHING <br />1. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW <br />WALL SHEATHING PER PLAN <br />AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />WALL SHEATHING PER PLAN <br />FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />SHINGLE WATER <br />SHINGLE WATER <br />FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />RESISTIVE BARRIER <br />RESISTIVE BARRIER <br />SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OVER FLASHING MIN 8" <br />OVER FLASHING MIN 8" <br />OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />\ <br />00 <br />00 <br />STARTER STRIP <br />STARTER STRIP <br />- <br />00 <br />1.1 THE FENESTRATION MANUFACTURERS INSTALLATION AND FLASHING <br />INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />RAKE WALL STEP FLASHING TO <br />FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />HEAD WALL TRIM FLASHING <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />TO EXTEND MIN 8" BEYOND <br />INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />UNDERLAYMENT <br />FIELD BEND PANEL UP 1 1/2" <br />INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />CONT SELF ADHERED <br />CONT BUTYL TAPE SEALANT PER <br />WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />FLASHING TURN 3" UP WALL <br />MANUFACTURE? INSTALLATION <br />RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN <br />INSTRUCTIONS <br />FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD <br />CONT BUTYL TAPE SEALANT PER <br />AND SIDES. <br />MANUFACTURER INSTALLATION <br />'Z' CLOSURE <br />INSTRUCTIONS 001.2 <br />IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />STANDING SEAM METAL <br />CO <br />REGISTERED DESIGN PROFESSIONAL. <br />'Z' CLOSURE <br />ROOF PER SPECS <br />1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />STANDING SEAM METAL <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />250, FMA/AAMA/WDMA 300 OR FMA/AAMA/WDMA 400. <br />TURN UP WALL MIN 8" <br />2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />ROOF SHEATHING <br />ROOF SHEATHING <br />COPINGS AND SILLS. <br />PER PLAN <br />PER PLAN <br />4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />CONT SELF ADHERED <br />WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. <br />FLASHING TURN 3" UP WALL <br />6.6 AT WALL AND ROOF INTERSECTIONS. <br />RAKE WALL <br />HEAD WALL <br />RAKE <br />WALL <br />7.7 AT BUILT-IN GUTTERS. <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />ROOF T WALL -STANDING SEAM ROOF TSIDING <br />W P 14 <br />_ <br />W P 15 <br />3„= 1 ,-0„ <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />C� <br />cu <br />MAY ? 1023 <br />}, <br />Q� <br />� <br />0 <br />� <br />Virtual Review Assist, Inc. <br />Plan s Review completed and approved <br />Nr compliance with the 2020 FBC <br />CIO <br />> <br />0 <br />7th Edit' <br />by Debra Anne Klahr PX2300 <br />L <br />4� <br />tL <br />O <br />0 <br />U <br />O <br />CD <br />US <br />cu <br />cu +�MM <br />W <br />W <br />Z <br />Z <br />Q <br />J <br />a <br />0 <br />SHEET N0. <br />WP 230 <br />
The URL can be used to link to this page
Your browser does not support the video tag.