My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6386 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6386 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 5:32:39 PM
Creation date
2/19/2025 8:22:23 AM
Metadata
Fields
Template:
Building Plans
Street #
6386
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
6223
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />NEMAI <br />150 AMP/ <br />200 AMP <br />3 to lights & outlets <br />2 to appliances and GFI <br />]toWH <br />to Range <br />t0 HVAC <br />0 <br />50=2/0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTE M <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from unished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed In <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />FE�b <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I'IV <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />CH <br />PB <br />DB <br />SD <br />CM <br />USB <br />a <br />0 2 <br />�O <br />FT— <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />{I <br />II <br />II <br />II <br />11 <br />K3 <br />G <br />1.5" VTR —III <br />I� <br />I <br />I <br />I <br />I I �> <br />� i I <br />I I I I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />SWITCH FOR DIS <br />KITCHGyIN <br />IGFI <br />IZE <br />DEDICATED <br />I RECEPTACLE <br />FOR MICROWAVE <br />IGFI RANGE HOOD <br />3 PER SPECS <br />37 11 <br />j I I <br />01 II <br />OPTIONAL LIGHTING <br />SCALE: %4'=1'-0" <br />r-----------i <br />I <br />ROUGH -IN FOR �/ 1 1 <br />OPT. CLG. FAN/ I I <br />'LIGHT PRE -WIRED 7 <br />I I <br />' BEDROOM 2 <br />I I <br />I I <br />I I I <br />I I <br />I I I <br />I ----------- <br />I 1 <br />I <br />I <br />I 1 <br />I 1 <br />I I <br />I 1 <br />I I <br />I <br />I 1 <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I <br />L---------------------------------------' <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET <br />r==== zi <br />Ir tl <br />II ALT II <br />I I AC PAD I I <br />Il ll <br />WP <br />GFI 4 <br />DISC. <br />�• ` PER SPECS <br />ELECTRICAL PLANS <br />SCALE: %4'=1'-0" <br />N <br />O <br />N <br />c <br />N <br />� <br />n <br />a> <br />> W <br />O � <br />C f0 C3 CV <br />m <br />C <br />t/! p tV i <br />N O f0 <br />a: N <br />L+ F <br />a> u d <br />� 3 � <br />iv 39 m t` <br />._ cj W <br />2� <br />n a <br />E <br />A � <br />a Cs <br />M <br />�O <br />�1�A1;.971lPd <br />cC.0V <br />cV <br />Cc_ <br />�` <br />&i:}eqa <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition, Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal, <br />W <br />H <br />Q <br />o <br />M o <br />� <br />2 co n <br />Q <br />J <br />V_ <br />� <br />J <br />� k LL a <br />a <br />Z13 <br />—ate �Yi <br />=ACc o <br />W <br />2 on m <br />W <br />Z <br />LL IL <br />'� N z d J <br />ZN <br />OU U <br />W <br />❑❑ <br />N <br />z <br />Z <br />a <br />N <br />N <br />Z m <br />C:) M <br />n <br />V <br />� <br />041— <br />LLJ <br />vos <br />f13 <br />now� <br />,— <br />E <br />s <br />" E <br />E <br />iO <br />o0 <br />E_ro <br />§ <br />Z® <br />Wo <br />O <br />On <br />U <br />BU <br />ro <br />E <br />°aa <br />Z <br />ro <br />� i <br />wz <br />v <br />§g� <br />3 <br />u0 <br />X <br />4 <br />Z 0 <br />[n <br />" <br />0 <br />az <br />W <br />a(CC <br />NLL <br />a� <br />F$ <br />�Q <br />zR <br />a� <br />C O <br />i <br />0 <br />it <br />0 <br />co LO <br />N <br />N <br />Qn <br />� N <br />CL <br />O <br />m <br />.° <br />N <br />f-- <br />a✓ <br />o <br />LO <br />O <br />LL <br />N <br />"fl <br />M N <br />m <br />O <br />T <br />M <br />r <br />E <br />4' <br />CO N <br />o <br />Z <br />N <br />y <br />C <br />E ., <br />Q) <br />e <br />JOB <br />NO : <br />23-04655 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.