Laserfiche WebLink
42" KNEE WALL WITH <br />1x8 CAP & CASING OR <br />- - 36" RAILING _ <br />36" H. CONT. <br />GRASPABLE <br />RAILING <br />3/4" PLYWOOD 16 <br />DECKING <br />15 <br />r 14 _ <br />- - - 13 - <br />PRE-ENG FLOOR 12 <br />TRUSS <br />11 <br />1x TREAD (TYP.) 10 <br />/ 9p <br />2x4 THRUST 1x RISERS (TYP.) r ( 7 <br />OP BLOCK <br />STRINGERS 42" KNEE WALL WITH ,( 5 <br />1x8 CAP &CASING OR 4 75 <br />3/4" PLYWOOD 36" RAILING ` 3 <br />DECKING <br />Cl) 2x6 LANDING 2x4 THRUST 2 <br />BLOCK 1 <br />2x4 FRAMING <br />TYP. STAIR SECTION <br />SCALE: 1/4" = V-0" <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSI <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 and R302.7. <br />User height: <br />fhe riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading edges of the <br />adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Tread depth: <br />the tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the vertical planes of <br />he foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any <br />light of stairs shall not exceed the smallest by more than 3/8 inch. <br />Ninders: <br />Ninder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the foremost <br />)rojection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread depth of not less than 6 <br />riches at any point within the clear width of the stair. <br />Vosings: <br />the radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 inch and not <br />pore than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the <br />Smallest nosing projection by more than 3/8 inch between two stories, including the nosing at the level of floors and landings. <br />3eveling of nosings shall not exceed 1/2 inch. <br />iandrails: <br />iandrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. Handrail <br />ieight measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less <br />:han 34 inches and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a <br />Joint directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be <br />eturned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than <br />11/2 inches between the wall and the handrails. <br />3rip-size: <br />iandrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater than 2 inches <br />)r provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />uards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30 <br />ches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. <br />equired guards at open -sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 <br />ches in height as measured vertically above the adjacent walking surface or the line connecting the leading edges of the <br />eads. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a <br />3here 4 inches in diameter. <br />nder-stair protection: <br />nclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the enclosed side <br />ith 1/2-inch gypsum board. <br />I SEE PLAN FOR LANDING DEPTH I <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1 <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM 0 <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENI: <br />LANDING FOI <br />STRINGERS <br />CONNECT TC <br />ih <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />9'-0" MAX LANDING LENGTH <br />3/4" PLYWOOD <br />DECKING <br />-2x6 LANDING <br />• 2x4 FRAMING <br />CONT. HANDRAIL <br />RETURN TO <br />WALL DETAIL <br />B SC <br />ALE:: NTS <br />25-4- <br />24" 16-1" 6-7" <br />2x4 #2 SPF STUDS @ 16" 1 <br />O.C. TYP. @ 2nd FLOOR 6 H1 6 E) H1 D2 <br />EXTERIOR WALLS B <br />TYP. @ <br />1/2 33 SH (2) 25-SH CORNERS <br />D2 TEMP D2 EGRESS <br />I o �r4-SH in <br />I iv <br />v BP l 1 u w SPECS. <br />C7 = 4'-4" io - _ 5 -6 - 2'4" - <br />I <br />uJ ° ISO BATH 3 <br />D2 <br />I- O Y p l l g' 0" FLAT CLG _-- -_ - - R/SH G.T.(1) <br />SIM. w/ _. o _ ILLIE <br />MSTAM36 <br />48x42 <br />3 RECESS' TB N @BASE <br />D2 SH01NER i F <br />O 12'-10" <br />SIM.w/(1) T1LET I I ��� 36"x22" <br />MSTAM36 7' A.J.F. I I I ATTIC <br />@ BASE ,- -- a' Imo__ _I _ _ ACCESS OWNER'S <br />19 W <br />iv <br />" N i 8'-0" F T CLG SUITE <br />:0 <br />C RPET <br />Tp I 2468 8'-0" FLAT CLG <br />CARPET - <br />19 <br />04 <br />N <br />10 4068 <br />B.F. <br />co <br />0 <br />BEDROOM 2 r- - - - - - - - - - - - <br />R/SH <br />8'-0" FLAT CLG - <br />CARPET <br />12'-2" 4,-8" 4, 7,-6" <br />ED <br />= w <br />r <br />O 2N W x r <br />ra co <br />LO <br />5068 2668 42" H 1/2 WALL I 16 v <br />B.F. OR RAILING PER r15 <br />SPECS I <br />J ----- I 14 <br />S6 t° = 6 <br />TYP. @ 2 - R/SH U N I 13 N D2 <br />STORY. SEE 12 <br />JJ/S6 FOR o co TECH I 11 O H1 <br />ST /S6 ALLFOR :-3-1 <br />° r CENTER I <br />OPT. __ r 1 10 <br />-7" 3'-4" 5'-8" T-3" 9 S-11„ <br />ILE TO 5' - 8 1 <br />I <br />Al`H <br />A.F.F. 8'-0" FLAT ClM 7 L1 <br />TILE 2868 <br />- P 6 <br />I 3 <br />� I <br />' fD D2 <br />" N M 2 3 4 5 SIM. w/ (1) <br />6g MSTAM36 <br />@ BASE <br />02 BEDROOM 3 4-SH <br />SIM. w/ (1) 8'-0" FLAT CLG a, <br />MSTAM36 - _ - CARPET ( - G.T. - _ _ _ _ _ ' <br />@ BASE <br />11'-6" 11'-2" <br />1 G.T_ <br />SIM. w/ (1) FI - - - - - � LL o------- <br />MSTAM36 C7I a I lot m v <br />@ BASE BEDROOM 4 r3 <br />3 I I 8'-0" FLAT CLG D2 <br />D2 r G.T. i CARPET SIM. w/ (1) <br />I <br />MSTAM36 = o 8 I rn @ BASE <br />1/2 33 SH 4 m I a <br />25-SH 25-SH <br />9 EGRESS 9 EGRES <br />D2 B 22 D2 B H1 <br />M I H1 D1 O <br />I <br />I----------- <br />2'-10" Z-10" 2'-11" 13'-6" 2'-11" <br />5'-8" 19'-4" 70, <br />I25'-0" <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J <br />REVISION NOTES 12/17/2009: <br />1. ALL CLOSETS THAT ARE NOT WALK-IN CLOSETS <br />ARE TO BE FRAMED DOWN TO 8'-0" A.F.F. <br />2. ALL BLOCK WALL FURRING IS TO BE 24" O.C. <br />EXCEPT IN WET AREAS. SPACE WET AREA <br />FURRING AT 16" O.C. <br />3. NO RECESSES FOR SHOWERS. SHOWERS ARE <br />TO BE PANNED WITH A PRE-FAB. BASE, <br />4. ALL VANITY HEIGHTS ARE 36" A.F.F. <br />5. SLIDING GLASS DOORS ARE TO HAVE A 1-1/2" <br />RECESS. REFER TO MASON'S SCOPE FOR <br />RECESS WIDTH. <br />6. ALL BATHROOMS HAVE ONE MEDICINE CABINET <br />7. ALL 50' PLANS. FRAME BAR TOP AT 40-1/2" A.F.F. <br />8. ALL TUB DECKS ARE SIZED AS FOLLOWS; <br />40' PRODUCT LINE - MIN. 48" x 64" <br />50' PRODUCT LINE - MIN. 48" x 76" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 2X8 #2 SYP W/ 1/2" <br />H2 <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />rA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />O <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />�F <br />+26.6 / -33.5 <br />�G <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />182X251 <br />S.H. <br />13 <br />20X38J <br />18;X37i <br />S.H. <br />14 <br />20X505 <br />18JX50 <br />S.H. <br />15 <br />20X63 <br />18�X62 <br />S.H. <br />16 <br />20X72 <br />182X71 <br />S.H. <br />11­12 <br />271/4X26 <br />26X25' <br />S.H. <br />1H3 <br />27 1/4 X 38 J <br />26 x 37 a <br />S.H. <br />1 H4 <br />27 IX 508 <br />26 x 50 <br />S.H. <br />11­15 <br />27 J X 63 <br />26 X 62 1/2 <br />S.H. <br />11-16 <br />271X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />3612 X 25 1/2 <br />S.H. <br />23 <br />37 a X 38 J <br />361 X 37 3/4 <br />S.H. <br />24 <br />37aX5058 <br />363X50 <br />S.H. <br />25 <br />37 J X 63 <br />36 2' X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />3612 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 4 X 25 <br />S.H. <br />33 <br />54 X 38 J <br />52 2 X 37 <br />S.H. <br />34 <br />54 X 501 <br />52 2 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 2 <br />S.H. <br />36 <br />54 X 72 <br />52 ; X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA 952 S.F. <br />SECOND FLOOR LIVING AREA 1121 S.F. <br />TOTAL LIVING AREA 2073 S.F. <br />GARAGE 396 S.F. <br />LANAI 104 S.F. <br />ENTRY 32 S.F. <br />TOTAL SQ. FT. 2605 S.F. <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN - ELEV-A <br />sV <br />0 <br />spa <br />c <br />cV <br />7� <br />C W <br />c <br />G W Ll <br />A N <br />3 =' W <br />c <br />U. <br />_ 3 3 % <br />CP <br />Cu % p <br />Vl G <br />c E <br />en <br />O <br />N <br />CM <br />N <br />\ , J <br />r <br />c M , <br />� <br />✓ ^ <br />, r.' Pot �- ,;p,' <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />cE <br />0 <br />2W,�� <br />M <br />inCaM <br />Iri <br />LL a. <br />0Z <br />-vim a 4 <br />0 <br />C� <br />W�2°'°' <br />W <br />z <br />� N Z 4 -' <br />Z" <br />OU <br />Cl) <br />Z N 0 <br />z <br />U) <br />N <br />V1 <br />Cl1 <br />U' <br />r� <br />ry <br />C' <br />U <br />O <br />-� <br />Vr^) <br />OflV <br />d <br />�^ <br />_ <br />so <br />U <br />w <br />_ s <br />I <br />_ <br />d <br />o <br />co <br />J< <br />w <br />M <br />J <br />w <br />zz <br />G <br />� <br />ti C <br />ra C <br />zo <br />>N <br />Q p <br />E U <br />wz <br />z® <br />oa <br />tT rd <br />o o <br />E <br />oQ <br />Z <br />CO ro <br />a, <br />M <br />�'0 <br />wg <br />wZ <br />�W <br />CO <br />0a <br />o�Z <br />of <br />Z <br />m <br />h m <br />¢ w <br />s <br />o <br />2z <br />W <br />A� <br />m <br />�� <br />wLL <br />�� <br />ww <br />� <br />az <br />=3 <br />o <br />v <br />$tea <br />°3 <br />O <br />N <br />>M <br />O <br />co LO <br />N <br />:3 N <br />C <br />L) <br />p' U <br />0 <br />N <br />U) m <br />N <br />f'- <br />+� <br />0 <br />LO <br />O <br />LIL <br />� <br />Y <br />m o <br />N <br />Q <br />M Q <br />T <br />ui <br />M <br />� N <br />�; <br />ci <br />Z <br />Z <br />E N <br />M <br />E <br />o ai <br />a <br />U � <br />¢ p <br />_J <br />JOB <br />NO: <br />23-04654 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />