Laserfiche WebLink
RECE <br />ABBREVIATIONS GENERAL NOTES VERSION CHANGES INDEX OF DRAWINGS I EL <br />ABV -ABOVE MLDG - MOULDING VERSION DESCRIPTION OF CHANGES SHT NO: TITLE ,AUGJ 5 Z08 <br />THE FOLLOWING TECHNICAL CODES SHALL APPLY: <br />AFF -ABOVE FINISH FLOOR MNT - MOUNT OR MOUNTING 1.0 PLAN REVISIONS CS COVER SHEET N <br />AHU -AIR HANDLER UNIT MO - MASONRY OPENING Al FOUNDATION PLAN N <br />A/C -AIR CONDITIONING MUNT - MUNTINS 2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING, MECHANICAL, FUEL GAS, 2.0 TYPICAL TRUSS CONNECTOR REVISION A2 1ST FLOOR PLAN 00 <br />ALUM - ALUMINUM # -NUMBER ENERGY EFFICIENCY, ACCESSIBILITY, AND NFPA 70 NATIONAL ELECTRICAL CODES 2017 <br />3.0 ELEVATION A ENTRY PORCH ROOF UPDATE A3 2ND FLOOR PLAN <br />LO <br />AT -ALUMINUM THRESHOLD OC - ON CENTER a <br />A4 ROOF PLAN <br />AB -ANCHOR BOLT OGD - OVERHEAD GARAGE DOOR 2020 FBC PLUMBING RESIDENTIAL SECTION 604 4.0 FLORIDA BUILDING CODE 7TH EDITION 2020 UPDATE p_ '�0'Y L' <br />( ) A4.1 2ND FLOOR FRAMING & ROOF PLAN o <br />AVG -AVERAGE OPNG - OPENING 1. TANK TYPE WATER CLOSET VOLUME �, ` •�� o <br />BFE - BASE FLOOD ELEVATION OPP - OPPOSITE 1.6 GALLONS 5.0 ADDING K, L, M ELEVATIONS A5 EXTERIOR ELEVATIONS "� < �°LO <br />A6 1ST FLOOR ELECTRICAL PLAN n* BM -BEAM OPT - OPTIONAL 6.0 ADDED SHEETS WP2.0 AND WP2.1 TO SHEET INDEX A6.1 2ND FLOOR ELECTRICAL PLAN eo CIO ; Q <br />BLK -BLOCK OH -OVER HANG 2. WATER - FLOW RATE. <br />BLDG - BUILDING OH CABS- OVERHEAD CABS SNO STRUCTURAL NOTES 4 w° <br />PUBLIC FACILITIES LAV 0.5 G.P.M. .o` z <br />BIRD -BOARD PNT -PAINT FINISH SN1 STRUCTURALNOTES FACILITIES LAV 2.2 G.P.M. <br />BRG - BEARING PTD - PAINTED TAILS S3M FOUNDATION DES4 FRAME WALL DETAILS O <br />BTM -BOTTOM PED -PEDESTAL <br />SHOWER HEADS 2.5 G.P.M. �,41 <br />BUC - BUILT UP COLUMN PERF -PERFORATED ` 0 <br />CAB - CABINET PLT -PLATE 3. ALL PLUMBING WATER LINES S5 ROOF FRAMING DETAILS • w - _ _ - " � <br />S6 WALL SECTION DETAILS �` 2 <br />CD -CONSTRUCTION DOCUMENTS PLYWD -PLYWOOD TO BE CPVC � .,��� <br />CLG - CEILING PKT -POCKET SS RETRO FIT DETAILS w <br />CLG HT - CEILING HEIGHT LB -POUND VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO ST STAIR DETAILS z <br />CEMT - CEMENTITIOUS PSF - POUNDS PER SQUARE FOOT JOBSITE CONDITIONS S11 PRECAST DETAILS q <br />CL - CENTERLINE PSI - POUNDS PER SQUARE S12 PRECAST DETAILS <br />COL -COLUMN PT - PRESSURE TREATED THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC RESIDENTIAL PA1.0 PRODUCT APPROVAL <br />CONC - CONCRETE PB - PUSH BUTTON CODE PA1.1 PRODUCT APPROVAL <br />CMU - CONCRETE MASONRY UNIT REF - REFRIGERATOR cn N LO F, E <br />CONST - CONSTRUCT OR CONSTRUCTION RECP -RECEPTACLE Q PORCHES AND BALCONIES PA1.2 PRODUCT APPROVAL L p o 0 <br />CONT - CONTINUOUS OR CONTINUES REINF - REINFORCING PA1.3 PRODUCT APPROVAL <br />CHAP. 3 ' p c� N m <br />CTR -CENTER READ -REQUIRED PA1.4 PRODUCT APPROVAL i, ,� N M <br />co u <br />CJ - CONTROL JOINT R/A - RETURN AIR Q HANDRAILS - CHAP. 3 PA1.5 PRODUCT APPROVAL V -0 -0 <br />DP - DEEP OR DEPTH RO - ROUGH OPENING SH 1.0 HURRICANE SHUTTERS E '6 u o <br />DTL - DETAIL IRS - ROUGH SAWN Q GUARDRAILS - CHAP. 3 SH 1.1 HURRICANE SHUTTERS g 6 <br />DIA - DIAMETER SC - SOLID CORE SH 1.2 HURRICANE SHUTTERS <br />DIM - DIMENSION SCP -SCUPPER <br />DISCON -DISCONNECT SCRN -SCREEN Q STAIRS - CHAP. 3 SH 1.3 HURRICANE SHUTTERS tn w Q N <br />DW - DISHWASHER SIM - SIMILAR SH 1.4 HURRICANE SHUTTERS 00 E <br />DR -DOOR SHLVS -SHELVES Q CHIMNEY & FIREPLACE SH 1.5 HURRICANE SHUTTERS � 0 o u a <br />CHAP. 10 WP1.0 WATERPROOFING DETAILS <br />DBL - DOUBLE S/R - SHELF & ROD WP2.0 WATERPROOFING DETAILS <br />DWG - DRAWING SH - SINGLE HUNG WINDOW <br />EA -EACH SGD - SLIDING GLASS DOOR Q EGRESS WINDOWS WP2.1 WATERPROOFING DETAILS <br />ELEC - ELECTRICAL SPECS - SPECIFICATIONS CHAP. 3 <br />ELEV -ELEVATOR SQ FT - SQUARE FEET <br />EQ -EQUAL SQ IN - SQUARE INCH 5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS <br />EQUP - EQUIPMENT STD -STANDARD STATED BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS <br />EXP JT - EXPANSION JOINT STL -STEEL AND O.H. GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE <br />EXT - EXTERIOR STRUCT -STRUCTURAL ITEMS. THE MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR <br />FIN FLR - FINISHED FLOOR TEMP -TEMPERED SITE INSTALLATION. <br />FIN - FIN THK - THICK OR THICKNESS <br />EW - EACH WAY TB - TOWEL BAR SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA <br />FG - FIXED GLASS TOC - TOP OF CONCRETE AND INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, <br />FD - FLOOR DRAIN TOM - TOP OF MASONRY OVERHEAD GARAGE DOORS, AND ROOFING. <br />FIE - FIRE EXTINGUISHER TOP - TOP OF PLATE <br />FLR -FLOOR TP - TOILET PAPER HOLDER <br />FLOUR - FLUORESCENT TYR - TYPICAL 6. ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED ALL <br />FTG - FOOTING UNO - UNLESS NOTED OTHERWISE SHOWER ENCLOSURES TO BE TEMPERED GLASS W P w w � o_ o <br />FIR DR - FRENCH DOOR VAC -VACUUM Lu (D Lu z o 2 J Q o ¢ � < 0 U Oe zx o <br />GALV - GALVANIZED VAL - VALkNCE 7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF Q Q U < a o J z X g z ° <br />GB -GRAB BAR VFRT-VERFIYAINFIELD O _3oa>z¢w°-zwzO0w0x� <br />GA - GAUGE FLR TO BE TEMPERED GLASS. (SECTION R308) ~ U) w w o o w o m° Z <br />U <br />GFI / GFCI - GROUND FAULT CIRCUIT INTERRUPTOR VTR -VENT THROUGH ROOF (n O Z ¢ o w U <br />GLS - GLASS V - VOLT DIMENSIONING: o Q ° ~ o ° � Q < ¢ a <br />GWB - GYPSUM WALL BOARD WC - WATER CLOSET <br />LL <br />GYPBRD - GYPSUM BOARD WH - WATER HEATER A. DIMENSIONS INDICATED ARE TO: <br />HD - HEAD WL - WIND LOAD A.1. CMU WALL: OUTSIDE FACE OF WALL <br />HVAC - HEATING, VENTILATING, AIR CONDITIONING WP - WEATHERPROOF A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF <br />HT - HEIGHT WWM - WELDED WIRE MESH CORE -STUD O <br />HB - HOSE BIB W - WIDE OR WIDTH A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. O <br />HC - HANDICAP WDW - WINDOW FURRING\ N <br />INSUL - INSULATION W/ - WITH A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF STRUCTURAL CORE -STUD \ z W <br />INT - INTERIOR WD -WOOD 0 I- <br />LVL - LAMINATED VENEER LUMBER A.4. WINDOW OPENINGS: <br />LT - LAUNDRY TUB A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING <br />LGT - LIGHT A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING �_ in COO O <br />MAY. - MAXIMUM A.5. DOOR OPENINGS: Q M O <br />MATL - MATERIAL A.5.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING Q w CM <br />MFR -MANUFACTURER A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING J <br />MECH - MECHANICAL A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN MEASURED LL. ti <br />MTL - METAL FROM THE FINISH FACE OF ADJACENT WALL TO INTERIOR FACE OF DOOR <br />MC - MEDICINE CABINET FRAME Q W Q u� <br />MIN - MINIMUM A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO CENTER ~ IZ M <br />OF DOOR Q Q O <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES - AS INDICATED ON PLANS OR FINISH z (� <br />SURFACE TO FINISH SURFACE z <br />SYMBOL LEGEND; A.6.1. EXAMPLE: 3'-0" CLEAR INSIDE FINISH FOR ADA TRANSFER SHOWER <br />B. ALIGNMENT OF WALLS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE AND uj <br />J O <br />= STAIR CALL OUT HEIGHT OF SHEET NUMBER PLUMB. <br />�, � STEP DOWN C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: A <br />d. <br />1 INT ELEV NUMBER C.1. CODE MINIMUM - MAXIMUM DIMENSIONS AND CLEARANCES <br />FOOTING CALL OUT - STEP DOWN ARROW SHOWS C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS <br />O = SEE FOOTING CALLOUT DIRECTION OF VIEW C.3. FRAMED WALLS EXTERIOR <br />SCHEDULE <br />ARROW SHOWS INTERIOR ELEVATION CA. FRAMED WALLS INTERIOR <br />= KEYNOTE CALL OUT DIRECTION OF VIEW MARKER C.5. DOORS AND WINDOWS <br />1 <br />SCHEDULE D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - 2 12023 <br />ELEV NUMBER UNLESS OTHERWISE NOTED <br />PRE -CAST LINTEL CALL SHEET NUMBER DIRECTION OF CUT <br />A9 ARROW SHOWS E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE <br />OLENTEL ELEVEXTERIORATION MARKER l OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED <br />4 <br />Al SECTION NUMBER F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF THE ' <br />STRUCTURAL MATERIAL ABOVE AS SCHEDULED Vir ual evi w A sist Inc <br />1 < ELEV NUMBER SHEET NUMBER Plans Re iew corn feted an r <br />G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, <br />LEDGER CALL OUT - SEE SHEET NUMBER CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND far complia a ith t e,2 20 BC h E itio <br />LEDGER SCHEDULE 41 <br />A15 2 COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE by braAhn I(l b� P 230 <br />�---ARROW SHOWS <br />LOCATION OF CUT DRAWINGS. <br />3 DIRECTION OF VIEW <br />MULTI VIEW INTERIOR SECTION 0 N 0 <br />ELEVATION MARKER MARKER 0 0 0 ,^ N N N N N N <br />LO o - o N o <br />O O CDr CD N N <br />CD�- CD CD O i <br />Z <br />O <br />NL w o O P. o 0 0 ; <br />> N co .T Lo Cfl i <br />LO <br />I r�%� <br />`V CID Z ~ <br />ZZ <br />CD q co <br />W <br />}� Z <br />rn Q W Woo <br />N N A Raw Lr) -0V/ U VU� <br />I- O Z' <br />0�_o <br />z �a <br />l0 w < <br />LENNAR TAMPA DIVISION A �, ��o <br />W CYPRESS ST SUITE 200 `V >_ 4600 C , , w 0- 2�2 <br />TAMPA, F L 33607 NOTICE TO BUILDER &ALL SUBCONTRACTORS O Jzx <br />z <br />IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE Z <br />813.574.5700 BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING z <br />LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT U J <br />HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL o O n- <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE M <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE LJJ w <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OMISSIONS,OR Q <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE z z <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL C S J <br />CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATIONui FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THE N <br />2216 INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE LAST PLOT BATE <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK > May 8, 2023 <br />CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE z O <br />DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND <br />APPROVAL BY THE DESIGN PROFESSIONAL. o _J COVER SHEET <br />