Laserfiche WebLink
CV <br />FD <br />6'-5" <br />BEDROOM <br />#4 <br />5'4' <br />\ _ =. <br />BEDROOM <br />#5 <br />V <br />CS <br />F � <br />4EDRO M <br />s #3 II <br />zo <br />OO <br />1'-7" <br />BATHROOM <br />f <br />#2 <br />GFI <br />A - o <br />iAHU /\ <br />OS <br />LIGHT AND <br />SWITCH IN <br />TTIC <br />T-9" <br />GF& LAUNDRY <br />�0 <br />/ ' in <br />F LOFT <br />SSdb -- -- <br />i 3 --- - <br />BEDROOM <br />\ #6 Vos I <br />GFI ------ <br />GFI ------ <br />/ OWNERS <br />BATHROOM To 1ST <br />GFI FLR ELEC <br />I I <br />6 -7 � I <br />OWNERS <br />BEDROOM <br />SECOND FLOOR ELECTRICAL PLAN (ALL ELEVATIONS) <br />1 /4" = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE. 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE, <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LfVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ° <br />DOORJAMB DUPLEX <br />OUTLET <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />k <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�}. TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />b— SWITCH AT 36" <br />- 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />.0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />—{] PUSH-BUTTON DOORBELL <br />-�- CLG MNT LT FIXTURE <br />{} CLG MNT PREWIRE - FIXTURE BY OWNER <br />-}- SURFACE MNT FIXTURE <br />- WALL MNT FIXTURE <br />NOTE: <br />0 TUB/SHOWER A6"ROUND OPALEX - ALTERNATE <br />CANS MAY BE <br />40 50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />0, 50W MR16 4" LOW VOLTAGE IOWNER <br />08 50W PAR20 NFL 4" MINI ROUND RECESS <br />00 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />{} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />SS SMOKE DETECTOR <br />C SMOKE DETECTOR <br />°U-182 UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />c D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />® 48"CLG MNT WRAPPED FLUOR LIGHT <br />5724:;g 24" VANITY LIGHTING <br />97-F 36 :;;R 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />119:3 ELEC PANEL <br />VACUM OUTLET AT 12" <br />F4CEILING RETURN AIR <br />EM A/C REGISTER <br />TT THERMOSTAT <br />On SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />0^` N L0 <br />W L C 0 u <br />in O �o� u a <br />M <br />O O u o <br />iu Q <br />• N w L _N <br />TN 0Ec m <br />v 0 0a �o <br />W <br />ow w0F_ <br />I-Q G= x¢~zx <br />W <br />Q QUZa0JLL <br />u0i(D <br />X:) 0 -O0Q�O <br />0 ZU--z_- <br />ggzoofoomzz�o <br />0 <br />ou) <br /><nwawin ww��0:¢'�� <br />w w O <br />U) Z <br />-J w<W<~ziWOOw0pQ <br />¢ <br />oCr o D o¢Z <br />,-¢ o <br />O <br />Z W <br />O� <br />> (n O <br />�WCMO <br />0-U)LLd' <br />QWQ� <br />F-WD..M_ <br />00 <br />Q Q <br />Z U F- <br />W <br />W <br />0 <br />O <br />UL <br />2 <br />121123 <br />Vi <br />tual <br />Rv <br />eu� <br />sdis <br />, in. <br />Plans R <br />viewco <br />plet <br />d a <br />d a <br />pro <br />for complia <br />ice <br />With <br />he 2020 <br />BC <br />th <br />�o <br />by <br />ebr <br />qn <br />a p <br />h[ <br />X23 <br />0 <br />N <br />O <br />o <br />O <br />O <br />0 <br />N <br />0 <br />M <br />0 <br />N <br />I� <br />0 <br />N <br />N <br />M <br />N <br />M <br />N <br />N <br />O <br />CD <br />— <br />CD <br />— <br />O <br />N <br />N <br />O <br />a <br />N <br />I <br />N <br />Z <br />0 <br />o <br />r- <br />o <br />0 <br />0 <br />; <br />' <br />O <br />N <br />W000000l <br />�j <br />� <br />N <br />M <br />4 <br />6 <br />6 <br />00 N <br />� z <br />¢Z <br />O <br />W <br />ZW <br />�00 <br />0 <br />c) <br />U � <br />Lo <br />O <br />oLUO <br />Q <br />z <br />a�a <br />^ <br />LW <br />I <br />= <br />W <br />m�tW <br />N <br />ot <br />zoo <br />. <br />W <br /><~� <br />(.0Q <br />O <br />ZWO <br />%. <br />_ N <br />Z <br />z <br />a- <br />Tz <br />� <br />OU <br />MM0 <br />W <br />z <br />a! <br />Z <br />w <br />W <br />J <br />N <br />0 <br />LAST PLOT DATE <br />• <br />May 8, 2023 <br />O <br />2ND FLOOR <br />J <br />ELECTRICAL PLAN <br />ABKL&M <br />